1.
Heart Rhythm ; 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38797305

RESUMO

BACKGROUND: Despite the implantable cardioverter defibrillator's (ICD) effectiveness in saving patients with life-threatening ventricular arrhythmias (VAs), the temporal occurrence of VA following ICD implantation is unpredictable. OBJECTIVE: Apply machine learning (ML) to intracardiac electrograms (IEGMs) recorded by ICDs as a unique biomarker for predicting impending VAs. METHODS: The study included 13,516 patients who received BIOTRONIK ICDs and enrolled in the CERTITUDE registry between 01/01/2010 to 12/31/2020. Database extraction included IEGMs from standard quarterly transmissions and VA event episodes. The processed IEGM data were pulled from device transmissions stored in a centralized Home Monitoring Service Center and reformatted into an analyzable format. Long- (baseline or first scheduled remote recording), mid-(scheduled remote recording every 90 days), or short-range predictions (IEGM within 5 seconds before the VA onset) were used to determine whether ML-processed IEGMs predicted impending VA events. Convolutional neural network classifiers using ResNet architecture were employed. RESULTS: Of 13,516 patients (male 72%, age 67.5 ± 11.9 years), 301,647 IEGM recordings were collected; 27,845 episodes of sustained VT/VF were observed in 4,467 patients (33.0%). Neural networks based on CNN using ResNet-like architectures on far-field IEGMs yielded an AUC of 0.83 with a 95% confidence interval of [0.79, 0.87] in the short-term, while the long- and mid-range analyses had minimal predictive value for VA events. CONCLUSION: In this study, applying ML to ICD-acquired IEGMs predicted impending VT/VF events seconds before they occurred, whereas mid- to long-term predictions were not successful. This could have important implications for future device therapies.

2.
Europace ; 2024 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-38703372

RESUMO

OBJECTIVES: To characterize the diagnosis, frequency, and procedural implications of septal venous channel perforation during left bundle branch area pacing (LBBAP). METHODS: All consecutive patients undergoing LBBAP over an 8-month period were prospectively studied. During lead placement, obligatory septal contrast injection was performed twice, at initiation (implant entry zone) and completion (fixation zone). An intuitive fluoroscopic schema using orthogonal views (LAO/RAO) and familiar landmarks is described. Using this, we resolved zonal distribution (I-VI) of lead position on the ventricular septum and its angulation (post-fixation angle θ). Subjects with/without septal venous channel perforation were compared. RESULTS: Sixty-one-patients [Male 57.3%, Median Age (IQR) 69.5(62.5-74.5) years] were enrolled. Septal venous channel perforation was observed in 8 (13.1%) patients [Male 28.5%, Median Age (IQR) 64(50-75) years]. They had higher frequency of, i) right-sided-implant (25% vs. 1.9%, p = 0.04), ii) fixation in zone III at the mid-superior septum (75% vs 28.3%, p = 0.04), iii) steeper angle of fixation- median θ (IQR) [19(10-30)° vs. 5(4-19)°, p = 0.01), and iv) longer median penetrated-lead-length (IQR) [13(10-14.8) vs. 10(8.5-12.5)mm, p = 0.03]. Coronary sinus drainage of contrast was noted in 5 (62.5%) patients. Abnormal impedance drops during implantation (12.5% vs. 5.7%, p = NS) were not significantly different. CONCLUSION: When evaluated systematically, septal venous channel perforation may be encountered commonly after LBBAP. The fiducial reference framework described using fluoroscopic imaging identified salient associated findings. This may be addressed with lead repositioning to a more inferior location and are not associated with adverse consequence acutely or in early follow-up.

3.
Proc Natl Acad Sci U S A ; 121(19): e2313590121, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38683978

RESUMO

Myokines and exosomes, originating from skeletal muscle, are shown to play a significant role in maintaining brain homeostasis. While exercise has been reported to promote muscle secretion, little is known about the effects of neuronal innervation and activity on the yield and molecular composition of biologically active molecules from muscle. As neuromuscular diseases and disabilities associated with denervation impact muscle metabolism, we hypothesize that neuronal innervation and firing may play a pivotal role in regulating secretion activities of skeletal muscles. We examined this hypothesis using an engineered neuromuscular tissue model consisting of skeletal muscles innervated by motor neurons. The innervated muscles displayed elevated expression of mRNAs encoding neurotrophic myokines, such as interleukin-6, brain-derived neurotrophic factor, and FDNC5, as well as the mRNA of peroxisome-proliferator-activated receptor γ coactivator 1α, a key regulator of muscle metabolism. Upon glutamate stimulation, the innervated muscles secreted higher levels of irisin and exosomes containing more diverse neurotrophic microRNAs than neuron-free muscles. Consequently, biological factors secreted by innervated muscles enhanced branching, axonal transport, and, ultimately, spontaneous network activities of primary hippocampal neurons in vitro. Overall, these results reveal the importance of neuronal innervation in modulating muscle-derived factors that promote neuronal function and suggest that the engineered neuromuscular tissue model holds significant promise as a platform for producing neurotrophic molecules.


Assuntos
Fator Neurotrófico Derivado do Encéfalo , Exossomos , Músculo Esquelético , Exossomos/metabolismo , Animais , Músculo Esquelético/metabolismo , Músculo Esquelético/inervação , Fator Neurotrófico Derivado do Encéfalo/metabolismo , Camundongos , Fibronectinas/metabolismo , Neurônios Motores/metabolismo , Interleucina-6/metabolismo , MicroRNAs/metabolismo , MicroRNAs/genética , Coativador 1-alfa do Receptor gama Ativado por Proliferador de Peroxissomo/metabolismo , Coativador 1-alfa do Receptor gama Ativado por Proliferador de Peroxissomo/genética , Neurônios/metabolismo , Fatores de Crescimento Neural/metabolismo , Miocinas
4.
Eur Heart J Case Rep ; 8(3): ytae106, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38500489

RESUMO

Background: There has been recent growing interest in the use of conduction system pacing (CSP) for both bradycardia and heart failure indications. There remains a paucity of data, however, regarding complications related to the intraventricular septum associated with CSP implant and the management of these events. Case summary: We present a case of a patient with non-ischemic dilated cardiomyopathy presenting for cardiac resynchronization therapy in whom left bundle branch area pacing was complicated with interventricular septal perforation and managed intra-procedurally with repositioning of the lead to provide His bundle pacing (HBP) for QRS correction of underlying left bundle branch block. Post-procedure echocardiography did not show persistent ventricular septal defect. Left ventricular ejection fraction improved from 13% four months before implant to 30% at 32 months post-implant. Corrective HBP pacing thresholds showed a rise at 3-year follow-up. Discussion: Interventricular septal perforation during CSP is a possible complication during lead fixation. Pre-operative septal assessment with imaging can be helpful to provide important septal anatomical features. Septal perforation can be managed appropriately with lead repositioning intra-procedurally and close follow-up.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38499825

RESUMO

BACKGROUND: Cardioneuroablation has been emerging as a potential treatment alternative in appropriately selected patients with cardioinhibitory vasovagal syncope (VVS) and functional AV block (AVB). However the majority of available evidence has been derived from retrospective cohort studies performed by experienced operators. METHODS: The Cardioneuroablation for the Management of Patients with Recurrent Vasovagal Syncope and Symptomatic Bradyarrhythmias (CNA-FWRD) Registry is a multicenter prospective registry with cross-over design evaluating acute and long-term outcomes of VVS and AVB patients treated by conservative therapy and CNA. RESULTS: The study is a prospective observational registry with cross-over design for analysis of outcomes between a control group (i.e., behavioral and medical therapy only) and intervention group (Cardioneuroablation). Primary and secondary outcomes will only be assessed after enrollment in the registry. The follow-up period will be 3 years after enrollment. CONCLUSIONS: There remains a lack of prospective multicentered data for long-term outcomes comparing conservative therapy to radiofrequency CNA procedures particularly for key outcomes including recurrence of syncope, AV block, durable impact of disruption of the autonomic nervous system, and long-term complications after CNA. The CNA-FWRD registry has the potential to help fill this information gap.

6.
JAMA Cardiol ; 9(5): 449-456, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38536171

RESUMO

Importance: Current left bundle branch block (LBBB) criteria are based on animal experiments or mathematical models of cardiac tissue conduction and may misclassify patients. Improved criteria would impact referral decisions and device type for cardiac resynchronization therapy. Objective: To develop a simple new criterion for LBBB based on electrophysiological studies of human patients, and then to validate this criterion in an independent population. Design, Setting, and Participants: In this diagnostic study, the derivation cohort was from a single-center, prospective study of patients undergoing electrophysiological study from March 2016 through November 2019. The validation cohort was assembled by retrospectively reviewing medical records for patients from the same center who underwent transcatheter aortic valve replacement (TAVR) from October 2015 through May 2022. Exposures: Patients were classified as having LBBB or intraventricular conduction delay (IVCD) as assessed by intracardiac recording. Main Outcomes and Measures: Sensitivity and specificity of the electrocardiography (ECG) criteria assessed in patients with LBBB or IVCD. Results: A total of 75 patients (median [IQR] age, 63 [53-70.5] years; 21 [28.0%] female) with baseline LBBB on 12-lead ECG underwent intracardiac recording of the left ventricular septum: 48 demonstrated complete conduction block (CCB) and 27 demonstrated intact Purkinje activation (IPA). Analysis of surface ECGs revealed that late notches in the QRS complexes of lateral leads were associated with CCB (40 of 48 patients [83.3%] with CCB vs 13 of 27 patients [48.1%] with IPA had a notch or slur in lead I; P = .003). Receiver operating characteristic curves for all septal and lateral leads were constructed, and lead I displayed the best performance with a time to notch longer than 75 milliseconds. Used in conjunction with the criteria for LBBB from the American College of Cardiology/American Heart Association/Heart Rhythm Society, this criterion had a sensitivity of 71% (95% CI, 56%-83%) and specificity of 74% (95% CI, 54%-89%) in the derivation population, contrasting with a sensitivity of 96% (95% CI, 86%-99%) and specificity of 33% (95% CI, 17%-54%) for the Strauss criteria. In an independent validation cohort of 46 patients (median [IQR] age, 78.5 [70-84] years; 21 [45.7%] female) undergoing TAVR with interval development of new LBBB, the time-to-notch criterion demonstrated a sensitivity of 87% (95% CI, 74%-95%). In the subset of 10 patients with preprocedural IVCD, the criterion correctly distinguished IVCD from LBBB in all cases. Application of the Strauss criteria performed similarly in the validation cohort. Conclusions and Relevance: The findings suggest that time to notch longer than 75 milliseconds in lead I is a simple ECG criterion that, when used in conjunction with standard LBBB criteria, may improve specificity for identifying patients with LBBB from conduction block. This may help inform patient selection for cardiac resynchronization or conduction system pacing.


Assuntos
Bloqueio de Ramo , Eletrocardiografia , Humanos , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos
7.
Front Cardiovasc Med ; 11: 1343424, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38322767

RESUMO

Introduction: Implantable cardiac monitors (ICMs) provide long-term arrhythmia monitoring, but high rates of false detections increase the review burden. The new "SmartECG" algorithm filters false detections. Using large real-world data sets, we aimed to quantify the reduction in workload and any loss in sensitivity from this new algorithm. Methods: Patients with a BioMonitor IIIm and any device indication were included from three clinical projects. All subcutaneous ECGs (sECGs) transmitted via remote monitoring were classified by the algorithm as "true" or "false." We quantified the relative reduction in workload assuming "false" sECGs were ignored. The remote monitoring workload from five hospitals with established remote monitoring routines was evaluated. Loss in sensitivity was estimated by testing a sample of 2000 sECGs against a clinical board of three physicians. Results: Of our population of 368 patients, 42% had an indication for syncope or pre-syncope and 31% for cryptogenic stroke. Within 418.5 patient-years of follow-up, 143,096 remote monitoring transmissions contained 61,517 sECGs. SmartECG filtered 42.8% of all sECGs as "false," reducing the number per patient-year from 147 to 84. In five hospitals, nine trained reviewers inspected on average 105 sECGs per working hour. This results in an annual working time per patient of 83 min without SmartECG, and 48 min with SmartECG. The loss of sensitivity is estimated as 2.6%. In the majority of cases where true arrhythmias were rejected, SmartECG classified the same type of arrhythmia as "true" before or within 3 days of the falsely rejected sECG. Conclusion: SmartECG increases efficiency in long-term arrhythmia monitoring using ICMs. The reduction of workload by SmartECG is meaningful and the risk of missing a relevant arrhythmia due to incorrect filtering by the algorithm is limited.

8.
Adv Sci (Weinh) ; 11(11): e2306826, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38161217

RESUMO

Motivated by the unexplored potential of in vitro neural systems for computing and by the corresponding need of versatile, scalable interfaces for multimodal interaction, an accurate, modular, fully customizable, and portable recording/stimulation solution that can be easily fabricated, robustly operated, and broadly disseminated is presented. This approach entails a reconfigurable platform that works across multiple industry standards and that enables a complete signal chain, from neural substrates sampled through micro-electrode arrays (MEAs) to data acquisition, downstream analysis, and cloud storage. Built-in modularity supports the seamless integration of electrical/optical stimulation and fluidic interfaces. Custom MEA fabrication leverages maskless photolithography, favoring the rapid prototyping of a variety of configurations, spatial topologies, and constitutive materials. Through a dedicated analysis and management software suite, the utility and robustness of this system are demonstrated across neural cultures and applications, including embryonic stem cell-derived and primary neurons, organotypic brain slices, 3D engineered tissue mimics, concurrent calcium imaging, and long-term recording. Overall, this technology, termed "mind in vitro" to underscore the computing inspiration, provides an end-to-end solution that can be widely deployed due to its affordable (>10× cost reduction) and open-source nature, catering to the expanding needs of both conventional and unconventional electrophysiology.


Assuntos
Encéfalo , Neurônios , Eletrodos , Encéfalo/fisiologia , Neurônios/fisiologia , Estimulação Elétrica , Fenômenos Eletrofisiológicos/fisiologia
9.
Langmuir ; 39(51): 18768-18783, 2023 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-38095945

RESUMO

We experimentally study the droplet impact on a flexible, hydrophilic cantilever beam. Droplets of water, water-glycerol (1:1 v/v), and glycerol were considered on a copper beam. Side visualization of the droplet impact on the cantilever was carried out by using a high-speed camera. We systematically vary cantilever stiffness to obtain a characteristic time scale of the beam dynamics, that is, shorter on the same order and longer than the characteristic time scale of droplet dynamics. Water droplet spreading reduces with an increase in the beam's flexibility, due to the "springboard effect". Results reveal that a threshold cantilever length exists beyond which the droplet vibration mode "locks-in" to the cantilever vibration mode. During lock-in, the bending energy of the beam increases with an increasing length or decreasing stiffness. The time-varying cantilever deflection exhibits an oscillatory, exponentially decaying response. However, in the case where both time scales are almost the same, we found a two-stage damping in the measurements: a fast, initial damping followed by a slower, damped response. We explain this damped response by the interplay of droplet and cantilever early dynamics. As expected, increasing the droplet viscosity dampens the magnitude of droplet spreading and displacement of the cantilever's tip due to a larger dissipation of kinetic energy in the bulk of the droplet. The decay is exponential in all cases, and the time taken to reduce the spreading and displacement is shorter with a larger viscosity. The damping coefficient is found to inversely scale with the cantilever length or mass. We corroborated the measurements with available analytical models, confirming the hypotheses used to explain the results. Overall, the present study provides fundamental insights into controlling the coupled dynamics of droplet and flexible substrates, with potential applications such as the design of efficient agricultural sprays and wings of microaerial vehicles.

10.
JACC Clin Electrophysiol ; 9(12): 2558-2570, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37737773

RESUMO

BACKGROUND: Active esophageal cooling reduces the incidence of endoscopically identified severe esophageal lesions during radiofrequency (RF) catheter ablation of the left atrium for the treatment of atrial fibrillation. A formal analysis of the atrioesophageal fistula (AEF) rate with active esophageal cooling has not previously been performed. OBJECTIVES: The authors aimed to compare AEF rates before and after the adoption of active esophageal cooling. METHODS: This institutional review board (IRB)-approved study was a prospective analysis of retrospective data, designed before collecting and analyzing the real-world data. The number of AEFs occurring in equivalent time frames before and after adoption of cooling using a dedicated esophageal cooling device (ensoETM, Attune Medical) were quantified across 25 prespecified hospital systems. AEF rates were then compared using generalized estimating equations robust to cluster correlation. RESULTS: A total of 14,224 patients received active esophageal cooling during RF ablation across the 25 hospital systems, which included a total of 30 separate hospitals. In the time frames before adoption of active cooling, a total of 10,962 patients received primarily luminal esophageal temperature (LET) monitoring during their RF ablations. In the preadoption cohort, a total of 16 AEFs occurred, for an AEF rate of 0.146%, in line with other published estimates for procedures using LET monitoring. In the postadoption cohort, no AEFs were found in the prespecified sites, yielding an AEF rate of 0% (P < 0.0001). CONCLUSIONS: Adoption of active esophageal cooling during RF ablation of the left atrium for the treatment of atrial fibrillation was associated with a significant reduction in AEF rate.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fístula Esofágica , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Estudos Retrospectivos , Fístula Esofágica/epidemiologia , Fístula Esofágica/etiologia , Ablação por Cateter/métodos
12.
J Am Coll Cardiol ; 82(11): 1096-1105, 2023 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-37673510

RESUMO

BACKGROUND: Factors determining hemodynamic stability during human ventricular tachycardia (VT) are incompletely understood. OBJECTIVES: The purposes of this study were to characterize sinus rate (SR) responses during monomorphic VT in association with hemodynamic stability and to prospectively assess the effects of vagolytic therapy on VT tolerance. METHODS: This is a retrospective analysis of patients undergoing scar-related VT ablation. Vasovagal responses were evaluated by analyzing sinus cycle length before VT induction and during VT. SR responses were classified into 3 groups: increasing (≥5 beats/min, sympathetic), decreasing (≥5 beats/min, vagal), and unchanged, with the latter 2 categorized as inappropriate SR. In a prospective cohort (n = 30) that exhibited a failure to increase SR, atropine was administered to improve hemodynamic tolerance to VT. RESULTS: In 150 patients, 261 VT episodes were analyzed (29% untolerated, 71% tolerated) with median VT duration 1.6 minutes. A total of 52% of VT episodes were associated with a sympathetic response, 31% had unchanged SR, and 17% of VTs exhibited a vagal response. A significantly higher prevalence of inappropriate SR responses was observed during untolerated VT (sustained VT requiring cardioversion within 150 seconds) compared with tolerated VT (84% vs 34%; P < 0.001). Untolerated VT was significantly different between groups: 9% (sympathetic), 82% (vagal), and 32% (unchanged) (P < 0.001). Atropine administration improved hemodynamic tolerance to VT in 70%. CONCLUSIONS: Nearly one-half of VT episodes are associated with failure to augment SR, indicative of an under-recognized pathophysiological vasovagal response to VT. Inappropriate SR responses were more predictive of hemodynamic instability than VT rate and ejection fraction. Vagolytic therapy may be a novel method to augment blood pressure during VT.


Assuntos
Taquicardia Ventricular , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Taquicardia Ventricular/terapia , Hemodinâmica , Atropina/farmacologia , Ubiquitina-Proteína Ligases
13.
JACC Clin Electrophysiol ; 9(11): 2358-2387, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37589646

RESUMO

The field of cardiac pacing has changed rapidly in the last several years. Since the initial description of His bundle pacing targeting the conduction system, recent advances in pacing the left bundle branch and its fascicles have evolved. The field and investigators' knowledge of conduction system pacing including relevant anatomy and physiology has advanced significantly. The aim of this review is to provide a comprehensive update on recent advances in conduction system pacing.


Assuntos
Fascículo Atrioventricular , Terapia de Ressincronização Cardíaca , Humanos , Bloqueio de Ramo/terapia , Eletrocardiografia , Sistema de Condução Cardíaco , Doença do Sistema de Condução Cardíaco/terapia
14.
Circulation ; 148(18): 1354-1367, 2023 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-37638389

RESUMO

BACKGROUND: The circuit boundaries for reentrant ventricular tachycardia (VT) have been historically conceptualized within a 2-dimensional (2D) construct, with their fixed or functional nature unresolved. This study aimed to examine the correlation between localized lines of conduction block (LOB) evident during baseline rhythm with lateral isthmus boundaries that 3-dimensionally constrain the VT isthmus as a hyperboloid structure. METHODS: A total of 175 VT activation maps were correlated with isochronal late activation maps during baseline rhythm in 106 patients who underwent catheter ablation for scar-related VT from 3 centers (42% nonischemic cardiomyopathy). An overt LOB was defined by a deceleration zone with split potentials (≥20 ms isoelectric segment) during baseline rhythm. A novel application of pacing within deceleration zone (≥600 ms) was implemented to unmask a concealed LOB not evident during baseline rhythm. LOB identified during baseline rhythm or pacing were correlated with isthmus boundaries during VT. RESULTS: Among 202 deceleration zones analyzed during baseline rhythm, an overt LOB was evident in 47%. When differential pacing was performed in 38 deceleration zones without overt LOB, an underlying concealed LOB was exposed in 84%. In 152 VT activation maps (2D=53, 3-dimensional [3D]=99), 69% of lateral boundaries colocalized with an LOB in 2D activation patterns, and the depth boundary during 3D VT colocalized with an LOB in 79%. In VT circuits with isthmus regions that colocalized with a U-shaped LOB (n=28), the boundary invariably served as both lateral boundaries in 2D and 3D. Overall, 74% of isthmus boundaries were identifiable as fixed LOB during baseline rhythm or differential pacing. CONCLUSIONS: The majority of VT circuit boundaries can be identified as fixed LOB from intrinsic or paced activation during sinus rhythm. Analysis of activation while pacing within the scar substrate is a novel technique that may unmask concealed LOB, previously interpreted to be functional in nature. An LOB from the perspective of a myocardial surface is frequently associated with intramural conduction, supporting the existence of a 3D hyperboloid VT circuit structure. Catheter ablation may be simplified to targeting both sides around an identified LOB during sinus rhythm.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Cicatriz , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas , Frequência Cardíaca/fisiologia , Bloqueio Cardíaco
16.
J Am Coll Cardiol ; 82(5): 383-397, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37495274

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to avoid complications related to transvenous implantable cardioverter-defibrillator (TV-ICD) leads. Device safety and efficacy were demonstrated previously with atypical clinical patients or limited follow-up. OBJECTIVES: The S-ICD PAS (Subcutaneous Implantable Cardioverter-Defibrillator System Post Approval Study) is a real-world, multicenter, registry of U.S. centers that was designed to assess long-term S-ICD safety and efficacy in a diverse group of patients and implantation centers. METHODS: Patients were enrolled in 86 U.S. centers with standard S-ICD indications and were observed for up to 5 years. Efficacy endpoints were first and final shock efficacy. Safety endpoints were complications directly related to the S-ICD system or implantation procedure. Endpoints were assessed using prespecified performance goals. RESULTS: A total of 1,643 patients were prospectively enrolled, with a median follow-up of 4.2 years. All prespecified safety and efficacy endpoint goals were met. Shock efficacy rates for discrete episodes of ventricular tachycardia or ventricular fibrillation were 98.4%, and they did not differ significantly across follow-up years (P = 0.68). S-ICD-related and electrode-related complication-free rates were 93.4% and 99.3%, respectively. Only 1.6% of patients had their devices replaced by a TV-ICD for a pacing need. Cumulative all-cause mortality was 21.7%. CONCLUSIONS: In the largest prospective study of the S-ICD to date, all study endpoints were met, despite a cohort with more comorbidities than in most previous trials. Complication rates were low and shock efficacy was high. These results demonstrate the 5-year S-ICD safety and efficacy for a large, diverse cohort of S-ICD recipients. (Subcutaneous Implantable Cardioverter-Defibrillator [S-ICD] System Post Approval Study [PAS]; NCT01736618).


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Resultado do Tratamento , Estudos Prospectivos , Arritmias Cardíacas/terapia , Taquicardia Ventricular/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle
17.
Cardiol Clin ; 41(3): 379-391, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37321688

RESUMO

Left bundle branch block (LBBB) is not just a simple electrocardiogram alteration. The intricacies of this general terminology go beyond simple conduction block. This review puts together current knowledge on the historical concept of LBBB, clinical significance, and recent insights into the pathophysiology of human LBBB. LBBB is an entity that affects patient diagnosis (primary conduction disease, secondary to underlying pathology or iatrogenic), treatment (cardiac resynchronization therapy or conduction system pacing for heart failure), and prognosis. Recruiting the left bundle branch with conduction system pacing depends on the complex interaction between anatomy, site of pathophysiology, and delivery tools.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Sistema de Condução Cardíaco , Eletrocardiografia , Prognóstico , Resultado do Tratamento , Função Ventricular Esquerda
18.
J Am Coll Cardiol ; 81(10): 949-961, 2023 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-36889873

RESUMO

BACKGROUND: Although implantable cardioverter-defibrillator (ICD) therapies are associated with increased morbidity and mortality, the prediction of malignant ventricular arrhythmias has remained elusive. OBJECTIVES: The purpose of this study was to evaluate whether daily remote-monitoring data may predict appropriate ICD therapies for ventricular tachycardia or ventricular fibrillation. METHODS: This was a post hoc analysis of IMPACT (Randomized trial of atrial arrhythmia monitoring to guide anticoagulation in patients with implanted defibrillator and cardiac resynchronization devices), a multicenter, randomized, controlled trial of 2,718 patients evaluating atrial tachyarrhythmias and anticoagulation for patients with heart failure and ICD or cardiac resynchronization therapy with defibrillator devices. All device therapies were adjudicated as either appropriate (to treat ventricular tachycardia or ventricular fibrillation) or inappropriate (all others). Remote monitoring data in the 30 days before device therapy were utilized to develop separate multivariable logistic regression and neural network models to predict appropriate device therapies. RESULTS: A total of 59,807 device transmissions were available for 2,413 patients (age 64 ± 11 years, 26% women, 64% ICD). Appropriate device therapies (141 shocks, 10 antitachycardia pacing) were delivered to 151 patients. Logistic regression identified shock lead impedance and ventricular ectopy as significantly associated with increased risk of appropriate device therapy (sensitivity 39%, specificity 91%, AUC: 0.72). Neural network modeling yielded significantly better (P < 0.01 for comparison) predictive performance (sensitivity 54%, specificity 96%, AUC: 0.90), and also identified patterns of change in atrial lead impedance, mean heart rate, and patient activity as predictors of appropriate therapies. CONCLUSIONS: Daily remote monitoring data may be utilized to predict malignant ventricular arrhythmias in the 30 days before device therapies. Neural networks complement and enhance conventional approaches to risk stratification.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/terapia , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/terapia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/etiologia , Desfibriladores Implantáveis/efeitos adversos , Anticoagulantes , Resultado do Tratamento
19.
Heart Rhythm O2 ; 4(3): 215-222, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36993915

RESUMO

Background: Whether racial disparities in outcomes are present after catheter ablation for scar-related ventricular tachycardia (VT) is not known. Objective: The purpose of this study was to examine whether racial differences exist in outcomes for patients undergoing VT ablation. Methods: From March 2016 through April 2021, consecutive patients undergoing catheter ablation for scar-related VT at the University of Chicago were prospectively enrolled. The primary outcome was VT recurrence, with secondary outcome of mortality alone and composite endpoint of left ventricular assist device placement, heart transplant, or mortality. Results: A total of 258 patients were analyzed: 58 (22%) self-identified as Black, and 113 (44%) had ischemic cardiomyopathy. Black patients had significantly higher rates of hypertension (HTN), chronic kidney disease (CKD), and VT storm at presentation. At 7 months, Black patients experienced higher rates of VT recurrence (P = .009). However, after multivariable adjustment, there were no observed differences in VT recurrence (adjusted hazard ratio [aHR] 1.65; 95% confidence interval [CI] 0.91-2.97; P = .10), all-cause mortality (aHR 0.49; 95% CI 0.21-1.17; P = .11), or composite events (aHR 0.76; 95% CI 0.37-1.54; P = .44) between Black and non-Black patients. Conclusion: In this diverse prospective registry of patients undergoing catheter ablation for scar-related VT, Black patients experienced higher rates of VT recurrence compared to non-Black patients. When adjusted for highly prevalent HTN, CKD, and VT storm, Black patients had comparable outcomes as non-Black patients.