1.
Acta Radiol ; 62(4): 462-473, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32611196

RESUMO

BACKGROUND: Localized pleural adhesion (LPA) evaluation in the apical region is difficult even with four-dimensional ultra-low-dose computed tomography (4D-ULDCT) in the supine position due to smaller pleural movements. PURPOSE: To assess usability of 4D-ULDCT in the lateral decubitus (LD) position for LPA detection in the apical region. MATERIAL AND METHODS: Forty-seven patients underwent 4D-ULDCT of a single respiration cycle with 16-cm coverage of body axis in supine and LD positions with the affected lung uppermost. Intraoperative thoracoscopic findings confirmed LPA presence. A pleural point and a corresponding point on costal outer edge were placed in identical axial planes at end-inspiration. Pleuro-chest wall distance between two points (PCD) was calculated at each respiratory phase. In the affected lung, average change in amount of PCD (PCDACA) was compared between patients with and without LPA in total and two sub-groups (non-COPD and COPD, non-emphysematous and emphysematous patients) in supine and non-dependent (ND) LD positions. Receiver operating characteristic (ROC) curve analysis was performed to determine optimal thresholds in PCDACA for differentiating patients with LPA from those without. RESULTS: In COPD/emphysematous patients and total population, PCDACA with LPA was smaller than in those without in the supine and NDLD positions for overall, lateral, and dorsal regions. For the lateral region in COPD patients, area under ROC curve (AUC) increased from supine (0.64) to NDLD position (0.81). For the dorsal region in emphysematous patients, AUC increased from supine (0.76) to NDLD position (0.96). CONCLUSION: 4D-ULDCT in LD position may be useful for LPA detection in apical regions for COPD and/or emphysematous patients.


Assuntos
Tomografia Computadorizada Quadridimensional , Posicionamento do Paciente , Doenças Pleurais/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Aderências Teciduais
2.
Eur J Radiol ; 128: 109033, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32416552

RESUMO

PURPOSE: To determine whether a 1024-matrix provides superior image quality for the evaluation of pulmonary nodules. MATERIALS AND METHODS: Prospective evaluation conducted between December 2017 and April 2018, during which CT images showing lung nodules of more than 6 mm and less than 30 mmm were reconstructed with 2 different protocols: 0.5-mm thickness, 512 × 512 matrix, 34.5-cm field of view (FOV) (0.5-512 protocol); and 2-mm thickness, 1024 × 1024 matrix, 34.5-cm FOV (2-1024 protocol). Lung nodule characteristics such as margin, lobulation, pleural indentation, spiculation as well as peripheral vessels and bronchioles visibility and overall image quality were evaluated by three chest radiologists, using a 5-point scale. Image noise was evaluated by measuring the standard deviation in the region of interest for each image. RESULTS: A total of 89 nodules were evaluated. The 2-1024 protocol performed significantly better for the subjective evaluation of pulmonary nodules (p = 0.006 ∼ p < 0.0001). However, image noise was significantly higher both subjectively and objectively (p = 0.036, p < 0.0001). CONCLUSION: The use of a 2-1024 protocol does not increase the amount of images and allows better assessment of pulmonary nodules, despite noise increase.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Pulmão/diagnóstico por imagem , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
3.
Acta Radiol ; 61(12): 1608-1617, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32212830

RESUMO

BACKGROUND: It is still unclear which image reconstruction algorithm is appropriate for peripheral bronchial luminal conspicuity (PBLC) on dynamic-ventilation computed tomography (DVCT). PURPOSE: To assess the influence of radiation doses and temporal resolution (TR) on the association between movement velocity (MV) and PBLC on DVCT. MATERIAL AND METHODS: An ex vivo porcine lung phantom with simulated respiratory movement was scanned by 320-row CT at 240 mA and 10 mA. Peak and dip CT density and luminal area adjusted by values at end-inspiration (CTDpeak and CTDdip, luminal area ratio [LAR]) for PBLC and MVs were measured and visual scores (VS) were obtained at 12 measurement points on 13 frame images obtained at half and full reconstructions (TR 340 and 190 ms) during expiration. Size-specific dose estimate (SSDE) was applied to presume radiation dose. VS, CTDpeak, CTDdip, LAR, and their cross-correlation coefficients with MV (CCC) were compared among four methods with combinations of two reconstruction algorithms and two doses. RESULTS: The dose at 10 mA was presumed as 26 mA by SSDE for standard proportion adults. VS, CTDdip, CTDpeak, and LAR with half reconstruction at 10 mA (2.52 ± 0.59, 1.016 ± 0.221, 0.948 ± 0.103, and 0.990 ± 0.527) were similar to those at 240 mA except for VS, and different from those with full reconstruction at both doses (2.24 ± 0.85, 0.830 ± 0.209, 0.986 ± 0.065, and 1.012 ± 0.438 at 240 mA) (P < 0.05). CCC for CTDdip with half reconstruction (-0.024 ± 0.552) at 10 mA was higher compared with full reconstruction (-0.503 ± 0.291) (P < 0.05). CONCLUSION: PBLC with half reconstruction at 10 mA was comparable to that at 240 mA and better than those with full reconstruction on DVCT.


Assuntos
Brônquios/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Animais , Técnicas In Vitro , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Respiração , Estudos Retrospectivos , Suínos
4.
Eur Radiol ; 30(6): 3324-3333, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32072253

RESUMO

OBJECTIVES: This study was conducted in order to compare the effect of field of view (FOV) size on image quality between ultra-high-resolution CT (U-HRCT) and conventional high-resolution CT (HRCT). METHODS: Eleven cadaveric lungs were scanned with U-HRCT and conventional HRCT and reconstructed with five FOVs (40, 80, 160, 240, and 320 mm). Three radiologists evaluated and scored the images. Three image evaluations were performed, comparing the image quality with the five FOVs with respect to the 160-mm FOV. The first evaluation was performed on conventional HRCT images, and the second evaluation on U-HRCT images. Images were scored on normal structure, abnormal findings, and overall image quality. The third evaluation was a comparison of the images obtained with conventional HRCT and U-HRCT, with scoring performed on overall image quality. Quantitative evaluation of noise was performed by setting ROIs. RESULTS: In conventional HRCT, image quality was improved when the FOV was reduced to 160 mm. In U-HRCT, image quality, except for noise, improved when the FOV was reduced to 80 mm. In the third evaluation, overall image quality was improved in U-HRCT over conventional HRCT at all FOVs. Noise of U-HRCT increased with respect to conventional HRCT when the FOV was reduced from 160 to 40 mm. However, at 240- and 320-mm FOVs, the noise of U-HRCT and conventional HRCT showed no differences. CONCLUSIONS: In conventional HRCT, image quality did not improve when the FOV was reduced below 160 mm. However, in U-HRCT, image quality improved even when the FOV was reduced to 80 mm. KEY POINTS: • Reducing the size of the field of view to 160 mm improves diagnostic imaging quality in high-resolution CT. • In ultra-high-resolution CT, improvements in image quality can be obtained by reducing the size of the field of view to 80 mm. • Ultra-high-resolution CT produces images of higher quality compared with conventional HRCT irrespective of the size of the field of view.


Assuntos
Pneumopatias/diagnóstico , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Cadáver , Humanos , Reprodutibilidade dos Testes
5.
Radiology ; 289(1): 255-260, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29944085

RESUMO

Purpose To examine the diagnostic performance of high-spatial-resolution (HSR) CT with 0.25-mm section thickness for evaluating renal artery in-stent restenosis. Materials and Methods A 0.05-mm wire phantom and vessel phantoms with renal stents with in-stent stenotic sections of varying diameters were scanned with both an HSR CT scanner equipped with 160-section multi-detector rows (0.25-mm section thickness) and a conventional CT scanner. The wire phantom was used to analyze modulation transfer function (MTF). With the vessel phantoms, the error rates were calculated as the absolute difference between the measured diameters and true diameters divided by the true diameters at the narrowing sections. For qualitative evaluation, overall image quality and diagnostic accuracy for evaluating stenosis in three stages were assessed by two radiologists. Statistical analyses included the paired t test, Wilcoxon signed-rank test, and McNemar test. Results HSR CT achieved 24.3 line pairs per centimeter ± 0.5 (standard deviation) and 29.1 line pairs per centimeter ± 0.4 at 10% and 2% MTF, respectively; and conventional CT was 12.5 line pairs per centimeter ± 0.1 and 14.3 line pairs per centimeter ± 0.1 at 10% and 2% MTF, respectively. The mean error rate of the measured diameter at HSR CT (8.0% ± 5.8) was significantly lower than that at at conventional CT (16.9% ± 9.3; P < .001). Image quality at HSR CT was significantly better than that at conventional CT (P < .001), but HSR CT was not significantly superior to conventional CT in terms of diagnostic accuracy. Conclusion Compared with conventional CT, high-spatial-resolution CT achieved spatial resolutions of up to 29 line pairs per centimeter at 2% modulation transfer function and yielded improved measurement accuracy for the evaluation of in-stent restenosis in a phantom study of renal artery stents. Published under a CC BY 4.0 license.


Assuntos
Oclusão de Enxerto Vascular/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Stents , Tomografia Computadorizada por Raios X/métodos , Desenho de Equipamento , Humanos , Modelos Biológicos , Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/instrumentação
6.
Eur Radiol ; 28(12): 5060-5068, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29845337

RESUMO

OBJECTIVES: To compare the image quality of the lungs between ultra-high-resolution CT (U-HRCT) and conventional area detector CT (AD-CT) images. METHODS: Image data of slit phantoms (0.35, 0.30, and 0.15 mm) and 11 cadaveric human lungs were acquired by both U-HRCT and AD-CT devices. U-HRCT images were obtained with three acquisition modes: normal mode (U-HRCTN: 896 channels, 0.5 mm × 80 rows; 512 matrix), super-high-resolution mode (U-HRCTSHR: 1792 channels, 0.25 mm × 160 rows; 1024 matrix), and volume mode (U-HRCTSHR-VOL: non-helical acquisition with U-HRCTSHR). AD-CT images were obtained with the same conditions as U-HRCTN. Three independent observers scored normal anatomical structures (vessels and bronchi), abnormal CT findings (faint nodules, solid nodules, ground-glass opacity, consolidation, emphysema, interlobular septal thickening, intralobular reticular opacities, bronchovascular bundle thickening, bronchiectasis, and honeycombing), noise, artifacts, and overall image quality on a 3-point scale (1 = worst, 2 = equal, 3 = best) compared with U-HRCTN. Noise values were calculated quantitatively. RESULTS: U-HRCT could depict a 0.15-mm slit. Both U-HRCTSHR and U-HRCTSHR-VOL significantly improved visualization of normal anatomical structures and abnormal CT findings, except for intralobular reticular opacities and reduced artifacts, compared with AD-CT (p < 0.014). Visually, U-HRCTSHR-VOL has less noise than U-HRCTSHR and AD-CT (p < 0.00001). Quantitative noise values were significantly higher in the following order: U-HRCTSHR (mean, 30.41), U-HRCTSHR-VOL (26.84), AD-CT (16.03), and U-HRCTN (15.14) (p < 0.0001). U-HRCTSHR and U-HRCTSHR-VOL resulted in significantly higher overall image quality than AD-CT and were almost equal to U-HRCTN (p < 0.0001). CONCLUSIONS: Both U-HRCTSHR and U-HRCTSHR-VOL can provide higher image quality than AD-CT, while U-HRCTSHR-VOL was less noisy than U-HRCTSHR. KEY POINTS: • Ultra-high-resolution CT (U-HRCT) can improve spatial resolution. • U-HRCT can reduce streak and dark band artifacts. • U-HRCT can provide higher image quality than conventional area detector CT. • In U-HRCT, the volume mode is less noisy than the super-high-resolution mode. • U-HRCT may provide more detailed information about the lung anatomy and pathology.


Assuntos
Pneumopatias/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Artefatos , Bronquiectasia/diagnóstico por imagem , Cadáver , Humanos , Imagens de Fantasmas , Enfisema Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/instrumentação
7.
Eur J Radiol ; 103: 71-75, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29803389

RESUMO

OBJECTIVES: To investigate the image quality of helical scan (HS) mode and non-helical scan (non-HS) mode on ultra-high-resolution CT in different gantry rotation time. METHODS: non-HS with 0.35 s/rot (non-HS200 mA/0.35 s). Three observers compared each non-HS image with HS image, and scored non-HS images by using 3-point scale, paying attention to normal findings, abnormal findings, noise, streak artifact, and overall image quality. Statistical analysis was performed with Steel-Dwass test. RESULTS: Overall image quality (score: 2.45) and noise (score: 2.42) of non-HS 200 mA/1.5s was statistically best (p < 0.0005). Overall Image quality and noise of non-HS200 mA/0.75 s (score: 2.0) was comparable to that of HS200 mA/1.5 s. CTDIvol of HS200 mA/1.5 s is 23.2 mGy. CTDIvol of non-HS200 mA/1.5 s, non-HS200 mA/0.75 s, non-HS200 mA/0.35 s is 19.2 mGy, 9.8 mGy, 4.7 mGy. CONCLUSION: Overall image quality and noise of non-helical scan is better than that of helical scan in the same rotation time. Overall Image quality of non-HS200 mA/0.75 s is comparable to that of HS200 mA/1.5 s, though the radiation dose of non-HS200 mA/0.75 s is lower than that of HS200 mA/1.5 s.


Assuntos
Pulmão/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Artefatos , Cadáver , Humanos , Rotação
8.
Acad Radiol ; 25(7): 869-876, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29373211

RESUMO

RATIONALE AND OBJECTIVES: This study aimed to assess the effect of matrix size on the spatial resolution and image quality of ultra-high-resolution computed tomography (U-HRCT). MATERIALS AND METHODS: Slit phantoms and 11 cadaveric lungs were scanned on U-HRCT. Slit phantom scans were reconstructed using a 20-mm field of view (FOV) with 1024 matrix size and a 320-mm FOV with 512, 1024, and 2048 matrix sizes. Cadaveric lung scans were reconstructed using 512, 1024, and 2048 matrix sizes. Three observers subjectively scored the images on a three-point scale (1 = worst, 3 = best), in terms of overall image quality, noise, streak artifact, vessel, bronchi, and image findings. The median score of the three observers was evaluated by Wilcoxon signed-rank test with Bonferroni correction. Noise was measured quantitatively and evaluated with the Tukey test. A P value of <.05 was considered significant. RESULTS: The maximum spatial resolution was 0.14 mm; among the 320-mm FOV images, the 2048 matrix had the highest resolution and was significantly better than the 1024 matrix in terms of overall quality, solid nodule, ground-glass opacity, emphysema, intralobular reticulation, honeycombing, and clarity of vessels (P < .05). Both the 2048 and 1024 matrices performed significantly better than the 512 matrix (P < .001), except for noise and streak artifact. The visual and quantitative noise decreased significantly in the order of 512, 1024, and 2048 (P < .001). CONCLUSION: In U-HRCT scans, a large matrix size maintained the spatial resolution and improved the image quality and assessment of lung diseases, despite an increase in image noise, when compared to a 512 matrix size.


Assuntos
Pneumopatias/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas , Artefatos , Cadáver , Humanos , Imagens de Fantasmas , Enfisema Pulmonar/diagnóstico por imagem , Razão Sinal-Ruído , Nódulo Pulmonar Solitário/diagnóstico por imagem
9.
J Comput Assist Tomogr ; 39(4): 629-34, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26125298

RESUMO

OBJECTIVE: To evaluate the image quality and radiation dose reduction in pelvic computed tomography (CT) achieved with an adaptive iterative dose reduction 3-dimensional (AIDR 3D) algorithm using a phantom model. METHODS: Two phantoms were scanned using a 320-detector row CT scanner with 8 tube current levels, and the images were reconstructed with a standard filtered back projection (FBP) algorithm and with an AIDR 3D algorithm. RESULTS: Compared with FBP, AIDR 3D reduced image noise and improved contrast-to-noise ratios. The diagnostic performance for detection of low-contrast targets of AIDR 3D images obtained with 100 mA at 120 kVp was almost as good as that of the FBP images obtained with 200 mA. CONCLUSIONS: The AIDR 3D algorithm substantially reduced image noise and improved the image quality of pelvic CT images compared with those obtained with the FBP algorithm and can thus be considered a promising technique for low-dose pelvic CT examinations.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Pelve/diagnóstico por imagem , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Doses de Radiação , Razão Sinal-Ruído
10.
JACC Cardiovasc Imaging ; 2(11): 1253-61, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19909928

RESUMO

OBJECTIVES: We sought to investigate the time course of post-systolic thickening (PST) and systolic abnormality after recovery from brief myocardial ischemia. BACKGROUND: Myocardial ischemic memory imaging, denoting the visualization of abnormalities provoked by ischemia and sustained even after restoration of perfusion, is desirable and allows after-the-fact recognition of ischemic insult. PST offers a sensitive marker of myocardial ischemia, but whether this abnormal thickening remains after relief from brief ischemia is unclear. METHODS: Tissue strain echocardiographic data were acquired from 27 dogs under 2 different conditions of myocardial ischemia induced by either brief coronary occlusion (15 or 5 min) followed by reperfusion (Protocol 1) or by dobutamine stress during nonflow-limiting stenosis (Protocol 2). Peak systolic strain and post-systolic strain index (PSI), a parameter of PST, were analyzed. RESULTS: In Protocol 1, peak systolic strain was significantly decreased in the risk area during occlusion. This decrease in peak systolic strain in the 15-min group did not completely recover to baseline levels even 120 min after reperfusion, whereas the decrease in the 5-min group recovered immediately after reperfusion. We found that PSI was significantly increased during occlusion, but increased PSI in the 5-min group remained until 30 min after reperfusion (-0.19 +/- 0.18 [baseline] vs. 0.19 +/- 0.14 [30 min], p < 0.05) despite the rapid recovery of peak systolic strain. In Protocol 2, increased PSI was sustained until 20 min after the end of dobutamine infusion (-0.26 +/- 0.11 [baseline] vs. -0.16 +/- 0.10 [20 min], p < 0.05), although peak systolic strain recovered by 5 min after the end of dobutamine infusion. CONCLUSIONS: PST remained longer than abnormal peak systolic strain after recovery from ischemia. Assessment of PST may be valuable for detecting myocardial ischemic memory.


Assuntos
Contração Miocárdica , Isquemia Miocárdica/fisiopatologia , Animais , Pressão Sanguínea , Modelos Animais de Doenças , Cães , Ecocardiografia Doppler em Cores , Frequência Cardíaca , Isquemia Miocárdica/diagnóstico por imagem , Miocárdio/patologia , Necrose , Variações Dependentes do Observador , Recuperação de Função Fisiológica , Reprodutibilidade dos Testes , Sístole , Fatores de Tempo
11.
JACC Cardiovasc Imaging ; 1(2): 210-20, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19356430

RESUMO

OBJECTIVES: The purpose of this study was to investigate the diagnostic value of velocity vector imaging (VVI) for detecting acute myocardial ischemia and whether VVI can accurately demonstrate the spatial extent of ischemic risk area. BACKGROUND: Using a tracking algorithm, VVI can display velocity vectors of regional wall motion overlaid onto the B-mode image and allows the quantitative assessment of myocardial mechanics. However, its efficacy for diagnosing myocardial ischemia has not been evaluated. METHODS: In 18 dogs with flow-limiting stenosis and/or total occlusion of the coronary artery, peak systolic radial velocity (V(SYS)), radial velocity at mitral valve opening (V(MVO)), peak systolic radial strain, and the percent change in wall thickening (%WT) were measured in the normal and risk areas and compared to those at baseline. Sensitivity and specificity for detecting the stenosis and occlusion were analyzed in each parameter. The area of inward velocity vectors at mitral valve opening (MVO) detected by VVI was compared to the risk area derived from real-time myocardial contrast echocardiography (MCE). Twelve image clips were randomly selected from the baseline, stenosis, and occlusions to determine the intra- and inter-observer agreement for the VVI parameters. RESULTS: The left circumflex coronary flow was reduced by 44.3 +/- 9.0% during stenosis and completely interrupted during occlusion. During coronary artery occlusion, inward motion at MVO was observed in the risk area. Percent WT, peak systolic radial strain, V(SYS), and V(MVO) changed significantly from values at baseline. During stenosis, %WT, peak systolic radial strain, and V(SYS) did not differ from those at baseline; however, V(MVO) was significantly increased (-0.12 +/- 0.60 cm/s vs. -0.96 +/- 0.55 cm/s, p = 0.015). Sensitivity and specificity of V(MVO) for detecting ischemia were superior to those of other parameters. The spatial extent of inward velocity vectors at MVO correlated well with that of the risk area derived from MCE (r = 0.74, p < 0.001 with a linear regression). CONCLUSIONS: The assessment of VVI at MVO permits easy detection of dyssynchronous wall motion during acute myocardial ischemia that cannot be diagnosed by conventional measurement of systolic wall thickness. The spatial extent of inward motion at MVO suggests the size of the risk area.


Assuntos
Oclusão Coronária/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Ecocardiografia Doppler , Contração Miocárdica , Isquemia Miocárdica/diagnóstico por imagem , Algoritmos , Animais , Circulação Coronária , Oclusão Coronária/fisiopatologia , Estenose Coronária/fisiopatologia , Cães , Interpretação de Imagem Assistida por Computador , Isquemia Miocárdica/fisiopatologia , Variações Dependentes do Observador , Valor Preditivo dos Testes , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
J Cardiol ; 50(3): 183-91, 2007 Sep.
Artigo em Japonês | MEDLINE | ID: mdl-17941194

RESUMO

BACKGROUND AND OBJECTIVES: False positive findings of coronary stenosis are frequently detected by exercise stress myocardial scintigraphy in patients with left bundle branch block (LBBB). We investigated the relationship between regional wall motion abnormality and myocardial perfusion abnormality at high right ventricular (RV) pacing rate in the region of the RV pacing (the ventricular septum) and the control region (the lateral wall) assuming exercise stress in patients with LBBB. METHODS: RV pacing was performed in 7 open chest canines. Real time myocardial contrast echocardiography of the left right ventricular short-axis view was examined by Toshiba Aplio during infusion of the ultrasound contrast agent (Definity). The examination was performed at baseline without pacing and at high RV pacing. Replenishment curve of the myocardial opacification was obtained and fit to the equation of y = A (1 - e (-betat)) in the regions of the ventricular septum and the lateral wall. Wall thickening ratio (%WT) was calculated in both regions. RESULTS: Dyssynchronous motion was observed during high RV pacing, but no wall motion abnormality was seen in control conditions. Although %WT, A-value and beta-value were almost identical between both regions at baseline, %WT and beta decreased in the ventricular septum at high RV pacing. The value did not differ between two regions. CONCLUSIONS: We concluded that perfusion abnormality occurs with regional wall motion abnormality at high RV pacing based on real time myocardial contrast echocardiography.


Assuntos
Bloqueio de Ramo/fisiopatologia , Estimulação Cardíaca Artificial , Circulação Coronária/fisiologia , Ecocardiografia , Animais , Estenose Coronária/fisiopatologia , Cães , Ecocardiografia sob Estresse , Ventrículos do Coração/fisiopatologia
13.
J Med Ultrason (2001) ; 33(2): 77-83, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27277725

RESUMO

PURPOSE: In high mechanical index (MI) contrast ultrasonography it has been shown that the power of contrast signal intensity (CI) has a strong linear correlation with the concentration of the ultrasound contrast agent under conditions of constant applied acoustic pressure. However, it is unclear whether the linearity is preserved in low-MI contrast ultrasonography. Thus, we investigated the relationship between ultrasound contrast concentration and CI in vitro. METHODS: Solutions of the ultrasound contrast agents Definity and Imagent were prepared at concentrations of 0.5, 2, 8, 32, and 128 µl/l. Placing a jelly block between the transducer and the solution, the solutions were transmitted using pulse subtraction imaging with an MI of 0.05, 0.1, and 0.5. CI was measured in dB in a region of interest 3 mm in height placed just below the border between the jelly and the solution. Data were plotted using double logarithm scales, where the concentration was expressed in dB as 10 × log (concentration). RESULTS: CI in dB had a strong linear correlation with concentration in dB for both agents with any MI. Best fitted slopes were close to 1, indicating that the power of CI is proportional to the concentration. CONCLUSIONS: In low-MI contrast ultrasonography, the power of CI is proportional to contrast concentration, and CI in dB is logarithmic to the concentration. Thus, the microbubble concentration can be quantitatively measured even in low-MI contrast ultrasonography.