Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Radiol ; 81(9): 2161-8, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21665395

RESUMO

PURPOSE: The objective is to study mammography practice from an optimisation point of view by assessing the impact of simple and immediately implementable corrective actions on image quality. MATERIALS AND METHODS: This prospective multinational study included 54 mammography units in 17 countries. More than 21,000 mammography images were evaluated using a three-level image quality scoring system. Following initial assessment, appropriate corrective actions were implemented and image quality was re-assessed in 24 units. RESULTS: The fraction of images that were considered acceptable without any remark in the first phase (before the implementation of corrective actions) was 70% and 75% for cranio-caudal and medio-lateral oblique projections, respectively. The main causes for poor image quality before corrective actions were related to film processing, damaged or scratched image receptors, or film-screen combinations that are not spectrally matched, inappropriate radiographic techniques and lack of training. Average glandular dose to a standard breast was 1.5 mGy (mean and range 0.59-3.2 mGy). After optimisation the frequency of poor quality images decreased, but the relative contributions of the various causes remained similar. Image quality improvements following appropriate corrective actions were up to 50 percentage points in some facilities. CONCLUSIONS: Poor image quality is a major source of unnecessary radiation dose to the breast. An increased awareness of good quality mammograms is of particular importance for countries that are moving towards introduction of population-based screening programmes. The study demonstrated how simple and low-cost measures can be a valuable tool in improving of image quality in mammography.


Assuntos
Interpretação de Imagem Assistida por Computador/normas , Mamografia/estatística & dados numéricos , Mamografia/normas , Guias de Prática Clínica como Assunto , Garantia da Qualidade dos Cuidados de Saúde/estatística & dados numéricos , Radiometria/estatística & dados numéricos , Radiometria/normas , África , Ásia , Europa Oriental , Humanos , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
AJR Am J Roentgenol ; 193(2): 559-69, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19620457

RESUMO

OBJECTIVE: The purpose of our study was to investigate the level of radiation protection of patients and staff during interventional procedures in 20 countries of Africa, Asia, and Europe. SUBJECTS AND METHODS: In a multinational prospective study, information on radiation protection tools, peak skin dose (PSD), and kerma-area product (KAP) was provided by 55 hospitals in 20 mainly developing countries (nine mostly in Eastern Europe, five in Africa, and six in Asia). RESULTS: Nearly 40% of the interventional rooms had an annual workload of more than 2,000 patients. It is remarkable that the workload of pediatric interventional procedures can reach the levels of adult procedures even in developing countries. About 30% of participating countries have shown a 100% increase in workload in 3 years. Lead aprons are used in all participating rooms. Even though KAP was available in almost half of the facilities, none had experience in its use. One hundred of 505 patients monitored for PSD (20%) were above the 2-Gy threshold for deterministic effects. CONCLUSION: Interventional procedures are increasing in developing countries, not only for adults but also for pediatric patients. The situation with respect to staff protection is considered generally acceptable, but this is not the case for patient protection. Many patients exceeded the dose threshold for erythema. A substantial number (62%) of percutaneous transluminal coronary angioplasty procedures performed in developing countries in this study are above the currently known dose reference level and thus could be optimized. Therefore, this study has significance in introducing the concept of patient dose estimation and dose management.


Assuntos
Exposição Ambiental/estatística & dados numéricos , Doses de Radiação , Monitoramento de Radiação/estatística & dados numéricos , Proteção Radiológica/estatística & dados numéricos , Radiografia Intervencionista/estatística & dados numéricos , Adulto , África , Poluentes Radioativos do Ar/análise , Ásia , Calibragem , Criança , Europa (Continente) , Feminino , Humanos , Masculino , Exposição Ocupacional/análise , Exposição Ocupacional/estatística & dados numéricos , Projetos Piloto , Estudos Prospectivos , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Espalhamento de Radiação , Carga de Trabalho/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...