1.
J Neuroimaging ; 25(4): 600-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25316522

RESUMO

BACKGROUND: To determine if extracranial venous structural and flow abnormalities exist in patients with multiple sclerosis (MS). METHODS: Magnetic resonance imaging was used to assess the anatomy and function of major veins in the neck in 138 MS patients and 67 healthy controls (HC). Time-of-flight MR angiography (MRA) was used to assess stenosis while 2-dimensional phase-contrast flow quantification was used to assess flow at the C2/C3 and C5/C6 levels. Venous flow was normalized to the total arterial flow. The MS patients were divided into stenotic (ST) and nonstenotic (NST) groups based on MRA assessment, and each group was compared to the HC group in anatomy and flow. RESULTS: The MS group showed lower normalized internal jugular vein (IJV) blood flow (tIJV/tA) than the HC group (P < .001). In the MS group, 72 (52%) were classified as ST while 66 (48%) were NST. In the HC group, 11 (23%) were ST while 37 (77%) were NST. The ST-MS group had lower IJV flow than both HC and NST-MS groups. CONCLUSION: After categorizing the MS population into two groups based upon anatomical stenosis, as determined from an absolute quantification of IJV cross section, clear differences in IJV flow between the ST-MS and HC samples became evident. Despite the unknown etiology of MS, abnormal venous flow was noted in a distinct group of MS patients compared to HC.


Assuntos
Veias Jugulares/fisiopatologia , Angiografia por Ressonância Magnética/métodos , Esclerose Múltipla/complicações , Esclerose Múltipla/fisiopatologia , Doenças Vasculares/etiologia , Doenças Vasculares/fisiopatologia , Adolescente , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
2.
Magn Reson Imaging ; 31(10): 1668-76, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23850076

RESUMO

BACKGROUND AND PURPOSE: The use of magnetic resonance imaging (MRI) to assess the vascular nature of diseases such as multiple sclerosis (MS) is a growing field of research. This work reports on the application of MR angiographic (MRA) and venographic (MRV) techniques in assessing the extracranial vasculature in MS patients. MATERIALS AND METHODS: A standardized MRI protocol containing 2D TOF-MRV and dynamic 3D contrast-enhanced (CE) MRAV was run for 170 MS patients and 40 healthy controls (HC). The cross-sectional area (CSA) of the internal jugular veins (IJVs) was measured at three neck levels in all subjects for both MRV techniques to determine the presence of venous stenoses. All data were analyzed retrospectively. RESULTS: For the values where both methods showed signal, the 3D method showed larger CSA measurement values compared to 2D methods in both IJVs, in both MS and HC subjects which was confirmed with student paired t-tests. Of the 170 MS patients, 93 (55%) in CE-MRAV and 103 (61%) in TOF-MRV showed stenosis in at least one IJV. The corresponding numbers for the 40 HC subjects were 2 (5%) and 4 (10%), respectively. Carotid ectasias with IJV stenosis were seen in 26 cases (15%) with 3D CE-MRAV and were not observable with 2D TOF-MRV. Carotid ectasias were not seen in the HC group. In the 2D TOF-MRV data, banding of the IJVs related to slow flow was seen in 58 (34%) MS cases and in no HC cases. MS patients showed lower average CSAs than the HC subjects. CONCLUSION: The 3D CE MRAV depicted the vascular anatomy more completely than the 2D TOF-MRV. However, the 3D CE MRAV does not provide any information about the flow characteristics which are indirectly available in the 2D TOF-MRV in those cases where there is slow flow.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Veias Jugulares/patologia , Angiografia por Ressonância Magnética/métodos , Esclerose Múltipla/patologia , Insuficiência Venosa/patologia , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/complicações , Flebografia/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Insuficiência Venosa/complicações