Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Contemp Clin Dent ; 12(4): 419-425, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35068843

RESUMO

AIM AND OBJECTIVES: The objective of the study was to clinically and radiographically compare and evaluate the regenerative potential of recombinant human bone morphogenetic protein-2 (RhBMP-2) impregnated with absorbable collagen sponge and platelet-rich fibrin (PRF) in the treatment of Grade II furcation defects. PATIENTS AND METHODS: Thirty-two subjects were randomly assigned to each of the following groups: bone morphogenetic protein (BMP) group and PRF group, with one defect/subject. Sixteen Grade II furcation defects were treated with RhBMP-2 impregnated with absorbable collagen sponge in the BMP group and the remaining 16 defects were treated with PRF in the PRF group. Clinical and radiographic parameters which were evaluated at baseline, postoperative 1 week, 3 months, and 6 months were probing pocket depth, clinical attachment level, scoring of plaque index, and gingival index, and the bone fill was evaluated using Digital Subtraction technique and morphometric area analysis with ImageJ® software. RESULTS: RhBMP-2 in absorbable collagen sponge was effective in increasing the bone fill in Grade II furcation defects when compared to PRF alone (P = 0.05). In relation to clinical parameters, both the groups showed no statistical significance between them. CONCLUSION: The unique regenerative potential of RhBMP-2 impregnated with absorbable collagen sponge makes it a potential agent to be used as a graft material for the treatment of Grade II furcation defects.

2.
J Indian Soc Periodontol ; 24(5): 461-466, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33144775

RESUMO

BACKGROUND: Implant therapy, in India, has flourished in recent years and is being practiced widely by many dental practitioners today. Along with the increasing number of implants being placed today, there has also been a constant rise in the number of complications associated with it. OBJECTIVES: The aim of this study is to evaluate the knowledge and awareness of implant placement and management of peri-implant diseases among dental professionals. MATERIALS AND METHODS: A total of 568 dental practitioners were approached with a questionnaire for collecting data related to demographic details, experience, and knowledge about implant placement and management of its complications. Of these, only 262 were included as part of the statistical analysis. This data collected were compiled and analyzed using descriptive statistics. RESULTS: Results showed that most dentists who participated in this study have adequate knowledge about etiological factors and its management. Those who acquired implant skills through sources that are not in accordance with accepted standards had unsatisfactory knowledge and practice behavior. CONCLUSION: The awareness and knowledge regarding the implant procedures and their complications such as peri-implant mucositis and peri-implantitis were higher in self-trained dentists and by dentists who are practicing for >10 years and calls for updating of knowledge.

3.
Contemp Clin Dent ; 10(3): 433-439, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32308316

RESUMO

CONTEXT: To compare optical density (OD) and fibrinogen content of leukocyte-rich and platelet-rich fibrin (L-PRF) generated by standard protocol (2700 rotations per minute [RPM] for 12 min) versus relative centrifugal force (RCF)-adjusted protocol across two widely used laboratory centrifuges with swing-out rotors. AIMS: Centrifuges for PRF production generate forces in excess of 800 g. The study aimed to evaluate OD, fibrinogen content and effectiveness in bone-added osteotome sinus floor elevation (BAOSFE) of leukocyte-rich and platelet-rich fibrin (L-PRF) generated by the standard protocol (2700 RPM for 12 min) versus a RCF-adjusted protocol to generate precisely 400 g of force across two centrifuges with swing-out rotors. The outcomes were compared to a standard centrifuge configured to generate L-PRF as per the original Choukroun guidelines. SETTINGS AND DESIGN: Sample size for the present study was calculated using proportional power calculation. A minimum sample size of 8 per group was needed to detect a bone height difference of 2 mm when the power of the test is 0.80 at a significance level of 0.05. SUBJECTS AND METHODS: Based on the centrifuge and protocol used to generate L-PRF, 10 participants were assigned to each of the following groups are as follows: D group, fixed angle centrifuge (DUO Quattro®) at default setting. R-O group: Swing-out centrifuge (Remi 8C®) + standard protocol. R-A group: Remi 8C® centrifuge + RCF-adjusted protocol. C-O group: Swing-out centrifuge (Remi C854®) + standard protocol. and C-A group: Remi C854® + RCF-adjusted protocol. OD, fibrinogen content, and gain in bone fill and bone height after BAOSFE were the evaluated outcomes. STATISTICAL ANALYSIS USED: Data were analyzed using GraphPad Prism® Software version 6.0 (GraphPad Software Inc., La Jolla, USA) and SAS Software® version 9.3 versions (SAS, New Delhi, India). Data were summarized by mean ± standard deviation for continuous data and median ± inter-quartile range for the score data. The comparison between different time points was done by analysis of one-way repeated measures test, followed by post hoc test for score data. The comparison between two groups for repeated data was made by analysis of two-way repeated measures test and followed by post hoc test. Spearman's Rho correlation test was used to test the correlation between prognosis and the other variables. RESULTS: L-PRF from the Remi C854® centrifuge with RCF-adjusted protocol showed OD (P = 0.152) and fibrinogen content (P = 0.232) identical to those from the DUO Quattro® centrifuge. L-PRF from Remi 8C® centrifuge with the RCF-adjusted protocol resulted in maximum postoperative bone height gain (7.01 ± 1.44 mm) and bone fill (13.50 ± 4.51 mm2) which was higher than that of the outcomes from the DUO Quattro® centrifuge (6.82 ± 2.92 mm and 12.32 ± 5.31 mm2). CONCLUSIONS: A reduction in RCF resulted in a less dense clot and had a positive influence on the regenerative potential of L-PRF in BAOSFE procedure.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...