Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Glob Epidemiol ; 6: 100126, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38023981

RESUMO

Background: The prevalence of post-COVID-19 Syndrome (PCS) is estimated to be between 10% and 20%. The main reported symptoms are fatigue, memory alterations, dyspnea, sleep disorders, arthralgia, anxiety, taste alterations, coughing and depression. This study aims to determine the prevalence of post-COVID-19 symptoms in a group of Colombian patients who were recruited during their outpatient appointments. Methodology: This cross-sectional study was conducted between December 2021 to May 2022. It included patients from outpatient facilities located in five main cities in Colombia who were positive for SARS-CoV-2 infection detected by reverse transcription-polymerase chain reaction (RT-PCR) testing and reported PCS in the following 12 weeks after their COVID-19 diagnosis. Results: A total of 1047 individuals >18 years old met the inclusion criteria and were included in the study. The median age was 46 years old. 68.2% of the participants were female, 41.5% of the patients reported having a pre-existent condition (hypertension, anxiety disorder, diabetes, hyperthyroidism, obesity and asthma). Only 22% had received at least one dose of COVID-19 vaccine prior to the COVID-19 episode registered. The more prevalent symptoms within our group are described as follows: fatigue (53.3%), dyspnea (40.3%), arthralgia and/or myalgia (43%), cephalea (40.5%), sleep disorders (35.7%) and coughing (31.3%). 72% of the patients presented four or more post-COVID 19 symptoms, 9% two symptoms, and 10% only one symptom. Conclusion: The findings of this study are consistent with international literature publicly available. The distribution and prevalence of post-COVID symptoms highlight the importance of further research to improve understanding and its potential consequences and implications in terms of quality of life and health care planning services.

3.
Galicia clin ; 83(3): 30-34, Jul.-sept. 2022. tab
Artigo em Inglês | IBECS | ID: ibc-212616

RESUMO

Palliative care is a topic that is gaining more and more relevance. This therapy benefits the patient throughout their illness, for that reason, the scientific community is becoming aware of the importance of including such treatments in basic health services. Unfortunately, only some of the developed countries manage to have decent assistance in this type of care, and that is why governments and world organizations are taking more ambitious objectives in order to improve health quality even more.The evidence presented in this article shows the future possibilities of PC, focusing its attention on pediatric patients and their families, as well as the guidelines to be followed by the professional team to guarantee a complete and satisfactory approach. (AU)


Los cuidados paliativos son un tema cada vez más de actualidad. Esta terapéutica beneficia al paciente a lo largo de toda su enfermedad, por lo que se empieza a tomar conciencia de la importancia de incluirlos en los servicios básicos de salud. Por desgracia sólo algunos de los países desarrollados consiguen tener una asistencia digna en este tipo de cuidados, y es por ello que gobiernos y organizaciones mundiales toman objetivos más ambiciosos con el fin de mejorar todavía más la calidad sanitaria.La evidencia presentada en el presente artículo muestra las posibilidades futuras de los cuidados paliativos, centrando su atención en los pacientes pediátricos y sus familias, así como las directrices a seguir por parte del equipo profesional para garantizar un abordaje completo y satisfactorio. (AU)


Assuntos
Humanos , Masculino , Feminino , Recém-Nascido , Lactente , Pré-Escolar , Criança , Adolescente , Cuidados Paliativos , Pediatria , Cuidados Paliativos na Terminalidade da Vida , Hospitais para Doentes Terminais , Família , Organização Mundial da Saúde
4.
J Fungi (Basel) ; 8(3)2022 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-35330318

RESUMO

Most cases of invasive aspergillosis are caused by Aspergillus fumigatus, whose conidia are ubiquitous in the environment. Additionally, in indoor environments, such as houses or hospitals, conidia are frequently detected too. Hospital-acquired aspergillosis is usually associated with airborne fungal contamination of the hospital air, especially after building construction events. A. fumigatus strain typing can fulfill many needs both in clinical settings and otherwise. The high incidence of aspergillosis in COVID patients from our hospital, made us wonder if they were hospital-acquired aspergillosis. The purpose of this study was to evaluate whether the hospital environment was the source of aspergillosis infection in CAPA patients, admitted to the Hospital Universitario Central de Asturias, during the first and second wave of the COVID-19 pandemic, or whether it was community-acquired aspergillosis before admission. During 2020, sixty-nine A. fumigatus strains were collected for this study: 59 were clinical isolates from 28 COVID-19 patients, and 10 strains were environmentally isolated from seven hospital rooms and intensive care units. A diagnosis of pulmonary aspergillosis was based on the ECCM/ISHAM criteria. Strains were genotyped by PCR amplification and sequencing of a panel of four hypervariable tandem repeats within exons of surface protein coding genes (TRESPERG). A total of seven genotypes among the 10 environmental strains and 28 genotypes among the 59 clinical strains were identified. Genotyping revealed that only one environmental A. fumigatus from UCI 5 (box 54) isolated in October (30 October 2020) and one A. fumigatus isolated from a COVID-19 patient admitted in Pneumology (Room 532-B) in November (24 November 2020) had the same genotype, but there was a significant difference in time and location. There was also no relationship in time and location between similar A. fumigatus genotypes of patients. The global A. fumigatus, environmental and clinical isolates, showed a wide diversity of genotypes. To our knowledge, this is the first study monitoring and genotyping A. fumigatus isolates obtained from hospital air and COVID-19 patients, admitted with aspergillosis, during one year. Our work shows that patients do not acquire A. fumigatus in the hospital. This proves that COVID-associated aspergillosis in our hospital is not a nosocomial infection, but supports the hypothesis of "community aspergillosis" acquisition outside the hospital, having the home environment (pandemic period at home) as the main suspected focus of infection.

5.
Sci Rep ; 11(1): 16859, 2021 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-34413329

RESUMO

Climate change scenarios predict increases in temperature and organic matter supply from land to water, which affect trophic transfer of nutrients and contaminants in aquatic food webs. How essential nutrients, such as polyunsaturated fatty acids (PUFA), and potentially toxic contaminants, such as methylmercury (MeHg), at the base of aquatic food webs will be affected under climate change scenarios, remains unclear. The objective of this outdoor mesocosm study was to examine how increased water temperature and terrestrially-derived dissolved organic matter supply (tDOM; i.e., lake browning), and the interaction of both, will influence MeHg and PUFA in organisms at the base of food webs (i.e. seston; the most edible plankton size for zooplankton) in subalpine lake ecosystems. The interaction of higher temperature and tDOM increased the burden of MeHg in seston (< 40 µm) and larger sized plankton (microplankton; 40-200 µm), while the MeHg content per unit biomass remained stable. However, PUFA decreased in seston, but increased in microplankton, consisting mainly of filamentous algae, which are less readily bioavailable to zooplankton. We revealed elevated dietary exposure to MeHg, yet decreased supply of dietary PUFA to aquatic consumers with increasing temperature and tDOM supply. This experimental study provides evidence that the overall food quality at the base of aquatic food webs deteriorates during ongoing climate change scenarios by increasing the supply of toxic MeHg and lowering the dietary access to essential nutrients of consumers at higher trophic levels.


Assuntos
Dieta , Ácidos Graxos Essenciais/análise , Compostos de Metilmercúrio/análise , Temperatura , Animais , Cadeia Alimentar , Lagos , Zooplâncton/fisiologia
6.
JACC Clin Electrophysiol ; 6(12): 1499-1506, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33213809

RESUMO

OBJECTIVES: This study sought to evaluate the proportion of patients with atrial fibrillation (AF) who also have undiagnosed sleep apnea and examine the impact of its diagnosis on adherence to sleep apnea therapies. BACKGROUND: Sleep apnea is a modifiable risk factor for AF. However, the proportion of patients with AF who also have undiagnosed sleep apnea and the impact of its diagnosis on therapy have not been well studied. METHODS: This prospective study included 188 consecutive patients with AF without a prior diagnosis of sleep apnea who were scheduled to undergo AF ablation. Participants underwent home sleep apnea testing, completed a sleep apnea screening questionnaire (STOP-BANG [Snoring; Tiredness, Fatigue, or Sleepiness During the Daytime; Observation of Apnea and/or Choking During Sleep; Hypertension; Body Mass Index >35 kg/m2; Age >50 Years; Neck Circumference >40 cm; and Male Sex]) and were followed for ≥2 years to evaluate the impact of diagnosis on therapy. RESULTS: Home sleep apnea testing was positive in 155 of 188 patients (82.4%); among those 155, 127 (82%) had a predominant obstructive component and 28 (18%) had mixed sleep apnea with a 15.2 ± 7.4% central component. Sleep apnea severity was mild in 43.8%, moderate in 32.9%, and severe in 23.2%. The sensitivity and specificity of a STOP-BANG questionnaire were 81.2% and 42.4%, respectively. In a multivariate analysis, STOP-BANG was not predictive for sleep apnea (odds ratio: 0.54; 95% confidence interval: 0.17 to 1.76; p = 0.31). Therapy with continuous positive airway pressure ventilators was initiated in 73 of 85 patients (85.9%) with moderate or severe sleep apnea, and 68 of the 73 patients (93.1%) remained complaint after a mean follow-up period of 21 ± 6.2 months. CONCLUSIONS: Sleep apnea is exceedingly prevalent in patients with AF who are referred for ablation, with a large proportion being undiagnosed due the limited predictive value of sleep apnea symptoms in this AF population. Screening for sleep apnea resulted in high rate of long-term continuous positive airway pressure adherence.


Assuntos
Fibrilação Atrial , Síndromes da Apneia do Sono , Apneia Obstrutiva do Sono , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Prevalência , Estudos Prospectivos , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/epidemiologia , Apneia Obstrutiva do Sono/epidemiologia
7.
Enferm Infecc Microbiol Clin (Engl Ed) ; 38 Suppl 1: 7-11, 2020 Jan.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32111369

RESUMO

Syphilis is a sexually transmitted infection caused by Treponema pallidum subsp. pallidum with an increasing incidence in Spain and in the rest of the world. Diagnosis is based mainly on serology, since direct diagnosis by dark field microscopy presents difficulties that limit its widespread use. Molecular biology techniques can be a useful tool for diagnosis in primary and secondary syphilis, although not all types of samples show the same behaviour. These techniques are also useful for the diagnosis of congenital syphilis. They are not recommended, however, for neurosyphilis, due to the low sensitivity of polymerase chain reaction in cerebrospinal fluid. These techniques have been used to study the controversial origin of syphilis, and, through the enhanced Centers for Disease Control method, to perform typing, which helps to elucidate the epidemiology of this infection. Finally, molecular techniques can detect mutations related to macrolide resistance, which are present in a very high percentage of infections.


Assuntos
Técnicas de Diagnóstico Molecular , Sífilis/diagnóstico , Antibacterianos/farmacologia , Farmacorresistência Bacteriana/efeitos dos fármacos , Humanos , Macrolídeos , Espanha , Treponema , Treponema pallidum/efeitos dos fármacos , Treponema pallidum/genética
8.
Artigo em Espanhol | IBECS | ID: ibc-201380

RESUMO

La sífilis es una infección de transmisión sexual causada por Treponema pallidum subsp. pallidum, cuya incidencia está aumentando en España y en el resto del mundo. El diagnóstico se basa fundamentalmente en la serología, puesto que el diagnóstico directo mediante microscopía de campo oscuro presenta dificultades que limitan su generalización. Las técnicas de biología molecular pueden ser una herramienta útil para el diagnóstico en sífilis primaria y secundaria, si bien no todos los tipos de muestra se comportan igual. También son útiles para el diagnóstico de la sífilis congénita, mientras que para la neurosífilis, y debido a la baja sensibilidad de la reacción en cadena de la polimerasa en el líquido cefalorraquídeo, no se recomiendan. Estás técnicas se han empleado para estudiar el controvertido origen de la sífilis, y mediante el sistema mejorado de los Centers for Disease Control and Prevention para realizar la tipificación que ayude a comprender mejor la epidemiología. Por último, las técnicas moleculares permiten determinar la presencia de mutaciones relacionadas con resistencia a los macrólidos, presentes en un porcentaje muy elevado de las infecciones


Syphilis is a sexually transmitted infection caused by Treponema pallidum subsp. pallidum with an increasing incidence in Spain and in the rest of the world. Diagnosis is based mainly on serology, since direct diagnosis by dark field microscopy presents difficulties that limit its widespread use. Molecular biology techniques can be a useful tool for diagnosis in primary and secondary syphilis, although not all types of samples show the same behaviour. These techniques are also useful for the diagnosis of congenital syphilis. They are not recommended, however, for neurosyphilis, due to the low sensitivity of polymerase chain reaction in cerebrospinal fluid. These techniques have been used to study the controversial origin of syphilis, and, through the enhanced Centers for Disease Control method, to perform typing, which helps to elucidate the epidemiology of this infection. Finally, molecular techniques can detect mutations related to macrolide resistance, which are present in a very high percentage of infections


Assuntos
Humanos , Sífilis/diagnóstico , Tipagem Molecular , Sífilis/epidemiologia , Treponema pallidum/genética , Farmacorresistência Bacteriana , Reação em Cadeia da Polimerase
10.
Circ Arrhythm Electrophysiol ; 11(8): e006536, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30354312

RESUMO

BACKGROUND: Activation mapping of scar-related atrial tachycardias (ATs) can be difficult to interpret because of inaccurate time annotation of complex electrograms and passive diastolic activity. We examined whether integration of a vector map can help to describe patterns of propagation to better explain the mechanism and location of ATs. METHODS: The investigational mapping algorithm calculates vectors and applies physiological constraints of electrical excitation in human atrial tissue to determine the arrhythmia source and circuit. Phase I consisted of retrospective evaluation in 35 patients with ATs. Phase II consisted of prospective validation in 20 patients with ATs. Macroreentry was defined as a continuous propagation in a circular path >30 mm; localized reentry was defined as a circular path ≤30 mm; a focal source had a centrifugal spread from a point source. RESULTS: In phase I, standard activation mapping identified 28 of 40 ATs (70%): 25 macroreentry and 3 focal tachycardias. In the remaining 12 ATs, the mechanism and location could not be identified by activation and required entrainment or empirical ablation for termination (radiofrequency time, 17.3±6.6 minutes). In comparison, the investigational algorithm identified 37 of 40 (92.5%) ATs, including 5 macroreentry, 3 localized reentry, and 1 focal AT not identified by standard mapping. It also predicted the successful termination site of all 37 of 40 ATs. In phase II, the investigational algorithm identified 12 macroreentry, 6 localized reentry, and 2 focal tachycardias that all terminated with limited ablation (3.2±1.7 minutes). It identified 3 macroreentry, 3 localized reentry, and 1 focal AT not well characterized by standard mapping. The diagnosis of localized reentry was supported by highly curved vectors, resetting with increasing curve and termination with limited ablation (22±6 s). CONCLUSIONS: Activation mapping integrating vectors can help determine the arrhythmia mechanism and identify its critical components. It has particular value for identifying complex macroreentrant circuits and for differentiating a focal source from a localized reentry.


Assuntos
Potenciais de Ação , Remodelamento Atrial , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração/fisiopatologia , Frequência Cardíaca , Processamento de Sinais Assistido por Computador , Taquicardia Supraventricular/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Bélgica , Ablação por Cateter , Feminino , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudo de Prova de Conceito , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
11.
JACC Clin Electrophysiol ; 4(8): 1033-1048, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30139485

RESUMO

OBJECTIVES: In this study, the scientific objective was to characterize the electrophysiological substrate of the ventricular tachycardia (VT) isthmus during sinus rhythm. BACKGROUND: The authors have recently described the electrophysiological characteristics of the VT isthmus using a novel in vivo high-resolution mapping technology. METHODS: Sixteen swine with healed infarction were studied using high-resolution mapping technology (Rhythmia, Boston Scientific, Cambridge, Massachusetts) in a closed-chest model. The left ventricle was mapped during sinus rhythm and analyzed for activation, conduction velocity, electrogram shape, and amplitude. Twenty-four VTs allowed detailed mapping of the common-channel "isthmus," including the "critical zone." This was defined as the zone of maximal conduction velocity slowing in the circuit, often occurring at entrance and exit from the isthmus caused by rapid angular change in activation vectors. RESULTS: The VT isthmus corresponded to sites displaying steep activation gradient (SAG) during sinus rhythm with conduction velocity slowing of 58.5 ± 22.4% (positive predictive value [PPV] 60%). The VT critical zone displayed SAG with greater conduction velocity slowing of 68.6 ± 18.2% (PPV 70%). Critical-zone sites were consistently localized in areas with bipolar voltage ≤0.55 mV, whereas isthmus sites were localized in areas with variable voltage amplitude (1.05 ± 0.80 mV [0.03 to 2.88 mV]). Importantly, critical zones served as common-site "anchors" for multiple VT configurations and cycle lengths. Isthmus and critical-zone sites occupied only 18.0 ± 7.0% of the low-voltage area (≤1.50 mV). Isolated late potentials were present in both isthmus and nonisthmus sites, including dead-end pathways (PPV 36%; 95% confidence interval: 34.2% to 39.6%). CONCLUSIONS: The VT critical zone corresponds to a location characterized by SAG and very low voltage amplitude during sinus rhythm. Thus, it allows identification of a re-entry anchor with high sensitivity and specificity. By contrast, voltage and electrogram characteristics during sinus rhythm have limited specificity for identifying the VT isthmus.


Assuntos
Infarto do Miocárdio , Taquicardia Ventricular , Animais , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Masculino , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/fisiopatologia , Suínos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia
12.
JACC Clin Electrophysiol ; 4(4): 467-479, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-30067486

RESUMO

OBJECTIVES: This study sought to examine the biophysical properties of high-power and short-duration (HP-SD) radiofrequency ablation for pulmonary vein isolation. BACKGROUND: Pulmonary vein isolation is the cornerstone of atrial fibrillation ablation. However, pulmonary vein reconnection is frequent and is often the result of catheter instability, tissue edema, and a reversible nontransmural injury. We postulated that HP-SD ablation increases lesion-to-lesion uniformity and transmurality. METHODS: This study included 20 swine and a novel open-irrigated ablation catheter with a thermocouple system able to record temperature at the catheter-tissue interface (QDOT Micro Catheter). Step 1 compared 3 HP-SD ablation settings: 90 W/4 s, 90 W/6 s, and 70 W/8 s in a thigh muscle preparation. Ablation at 90 W/4 s was identified as the best compromise between lesion size and safety parameters, with no steam-pop or char. In step 2, a total of 174 single ablation applications were performed in the beating heart and resulted in 3 (1.7%) steam-pops, all occurring at catheter-tissue interface temperature ≥85°C. Additional 233 applications at 90 W/4 s and temperature limit of 65°C were applied without steam-pop. Step 3 compared the presence of gaps and lesion transmurality in atrial lines and pulmonary vein isolation between HP-SD (90 W/4 s, T ≤65°C) and standard (25 W/20 s) ablation. RESULTS: HP-SD ablation resulted in 100% contiguous lines with all transmural lesions, whereas standard ablation had linear gaps in 25% and partial thickness lesions in 29%. Ablation with HP-SD produced wider lesions (6.02 ± 0.2 mm vs. 4.43 ± 1.0 mm; p = 0.003) at similar depth (3.58 ± 0.3 mm vs. 3.53 ± 0.6 mm; p = 0.81) and improved lesion-to-lesion uniformity with comparable safety end points. CONCLUSIONS: In a preclinical model, HP-SD ablation (90 W/4 s, T ≤65°C) produced an improved lesion-to-lesion uniformity, linear contiguity, and transmurality at a similar safety profile of conventional ablation.


Assuntos
Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Animais , Desenho de Equipamento , Átrios do Coração/efeitos da radiação , Humanos , Segurança do Paciente , Suínos , Temperatura
13.
J Cardiovasc Electrophysiol ; 29(9): 1287-1296, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29846987

RESUMO

INTRODUCTION: PV reconnection is often the result of catheter instability and tissue edema. High-power short-duration (HP-SD) ablation strategies have been shown to improve atrial linear continuity in acute pre-clinical models. This study compares the safety, efficacy, and long-term durability of HP-SD ablation with conventional ablation. METHODS AND RESULTS: In 6 swine, 2 ablation lines were performed anterior and posterior to the crista terminalis, in the smooth and trabeculated right atrium, respectively; and the right superior PV was isolated. In 3 swine, ablation was performed using conventional parameters (Thermocool-Smarttouch® SF; 30 W/30 seconds) and in 3 other swine using HP-SD parameters (QDOT-MICRO™, 90 W/4 seconds). After 30 days, linear integrity was examined by voltage mapping and pacing, and the heart and surrounding tissues were examined by histopathology. Acute line integrity was achieved with both ablation strategies; however, HP-SD ablation required 80% less RF time compared with conventional ablation (P ≤ 0.01 for all lines). Chronic line integrity was higher with HP-SD ablation: all 3 posterior lines were continuous and transmural compared to only 1 line created by conventional ablation. In the trabeculated tissue, HP-SD ablation lesions were wider and of similar depth with 1 of 3 lines being continuous compared to 0 of 3 using conventional ablation. Chronic PVI without stenosis was evident in both groups. There were no steam-pops. Pleural markings were present in both strategies, but parenchymal lung injury was only evident with conventional ablation. CONCLUSIONS: HP-SD ablation strategy results in improved linear continuity, shorter ablation time, and a safety profile comparable to conventional ablation.


Assuntos
Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Animais , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Sistema de Condução Cardíaco/fisiopatologia , Suínos , Fatores de Tempo , Resultado do Tratamento
14.
Med. paliat ; 24(4): 204-209, oct.-dic. 2017. tab
Artigo em Espanhol | IBECS | ID: ibc-167610

RESUMO

OBJETIVOS: Mejorar la seguridad del paciente es necesario en las unidades de cuidados paliativos donde no hay datos de incidentes y eventos adversos. Se analizaron los tipos de incidentes/eventos adversos, su frecuencia y gravedad en la Unidad de Cuidados Paliativos de un hospital de agudos geriátrico con el objetivo de introducir medidas que pudieran reducir su incidencia. MATERIAL Y MÉTODOS: Estudio retrospectivo de 6 años utilizando un sistema de notificación voluntaria, un sistema de notificación obligatoria para las caídas de los pacientes y la herramienta Global Trigger Tool. Se llevó a cabo en un hospital geriátrico universitario español de 200 camas (27 camas en la Unidad de Cuidados Paliativos). Se incluyeron todos los pacientes ingresados en la Unidad (1.854). La severidad del daño se calculó por el Index of the National Coordinating Council for Medication Error Reporting and Prevention. RESULTADOS: Se identificaron 743 incidentes/eventos adversos, de los cuales 518 (69,7%) eran incidentes (categorías A-D de la clasificación del National Coordinating Council for Medication Error Reporting and Prevention) y 201 eventos adversos (categorías E-I). Los cuidados generales (51,5%) y los errores de medicación (45,2%) fueron los más frecuentes. De estos últimos, los más comunes eran las omisiones de dosis/medicamentos (43,5%). Tanto los antihipertensivos-IECA, antibióticos, antiepilépticos y neurolépticos presentaban tasas de error por encima de la media (5,2), cuando se calcularon los cocientes de incidentes/dispensación. CONCLUSIONES: Este estudio revela un nivel de eventos adversos nada desdeñable dada la conocida falta de sensibilidad de los métodos de detección de eventos adversos, lo que implica la necesidad de desarrollar marcadores de alarma específicos de cuidados paliativos


OBJECTIVES: Improving patient safety is necessary in palliative care units where data on incidents and adverse events are lacking. An analysis was performed on the types of incidents/adverse events, their frequency and severity in the Palliative Care Unit of an Acute Geriatric Hospital with the aim of introducing measures that might lower their incidence. MATERIAL AND METHODS: A 6 year retrospective study was conducted using a voluntary reporting system, a compulsory reporting system for patient falls, and the Global Trigger Tool in a Spanish urban geriatric teaching hospital of 200 beds (27 beds in the Palliative Care Unit). All patients (1,854) admitted to the Unit were included. The Index of the National Coordinating Council for Medication Error Reporting and Prevention was used to evaluate severity. RESULTS: A total of 743 incidents/adverse events were identified, of which 518 (69.7%) were incidents (categories A-D of the National Coordinating Council for Medication Error Reporting and Prevention classification), and 201 were adverse events (categories E-I). General care (51.5%) and medication errors (45.2%) were the most frequent. Of the latter, missing doses/drugs were most common (43.5%). Antihypertensives-ACEIs, antibiotics, antiepileptics, and neuroleptics showed mistake rates above the mean (5.2) when the incident-adverse events/dispensation ratios were calculated. CONCLUSIONS: This study reveals a negligible level of adverse events, given the known low sensitivity of the detection methods of incidents/adverse events, which implies the need to develop specific alarms in Palliative Care


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Dano ao Paciente/prevenção & controle , Cuidados Paliativos na Terminalidade da Vida/organização & administração , Gestão da Segurança/organização & administração , Estudos Retrospectivos , Erros Médicos/estatística & dados numéricos , Notificação , Acidentes por Quedas/estatística & dados numéricos
15.
Artigo em Inglês | MEDLINE | ID: mdl-29133380

RESUMO

BACKGROUND: Obstructive sleep apnea (OSA) is associated with atrial remodeling, atrial fibrillation (AF), and increased incidence of arrhythmia recurrence after pulmonary vein (PV) isolation. We aimed to characterize the atrial substrate, including AF triggers in patients with paroxysmal AF and OSA. METHODS AND RESULTS: In 86 patients with paroxysmal AF (43 with ≥moderate OSA [apnea-hypopnea index ≥15] and 43 without OSA [apnea-hypopnea index <5]), right atrial and left atrial voltage distribution, conduction velocities, and electrogram characteristics were analyzed during atrial pacing. AF triggers were examined before and after PV isolation and targeted for ablation. Patients with OSA had lower atrial voltage amplitude (right atrial, P=0.0005; left atrial, P=0.0001), slower conduction velocities (right atrial, P=0.02; left atrial, P=0.0002), and higher prevalence of electrogram fractionation (P=0.0001). The areas of atrial abnormality were consistent among patients, most commonly involving the left atrial septum (32/43; 74.4%). At baseline, the PVs were the most frequent triggers for AF in both groups; however, after PV isolation patients with OSA had increased incidence of additional extra-PV triggers (41.8% versus 11.6%; P=0.003). The 1-year arrhythmia-free survival was similar between patients with and without OSA (83.7% and 81.4%, respectively; P=0.59). In comparison, control patients with paroxysmal AF and OSA who underwent PV isolation alone without ablation on extra-PV triggers had increased risk of arrhythmia recurrence (83.7% versus 64.0%; P=0.003). CONCLUSIONS: OSA is associated with structural and functional atrial remodeling and increased incidence of extra-PV triggers. Elimination of these triggers resulted in improved arrhythmia-free survival.


Assuntos
Fibrilação Atrial/etiologia , Veias Pulmonares/fisiopatologia , Apneia Obstrutiva do Sono/complicações , Potenciais de Ação , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Remodelamento Atrial , Ablação por Cateter , Intervalo Livre de Doença , Técnicas Eletrofisiológicas Cardíacas , Feminino , Frequência Cardíaca , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Fatores de Risco , Índice de Gravidade de Doença , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
16.
Heart Rhythm ; 14(8): 1234-1240, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28455271

RESUMO

BACKGROUND: An in vivo animal thigh model is the standard technique for evaluation of ablation catheter technologies, including efficacy and safety of ablation. However, the biophysics of ablation in a thigh model may not be similar to a beating heart. OBJECTIVE: The purpose of this study was to compare efficacy and safety of ablation between a thigh preparation model and a beating heart. METHODS: In 7 swine, radiofrequency ablation using a 3.5-mm open irrigated catheter (ThermoCool Smart Touch) was performed sequentially in a thigh muscle and in vivo beating ventricles. Ablation was performed at low (30 W for 40 s) and high (40 W for 60 s) energy settings and at similar contact force. Ablation lesions were scanned in high resolution and measured using electronic calipers. RESULTS: A total of 152 radiofrequency ablation lesions were measured (86 thigh and 66 heart). At low energy, lesion width was greater in the thigh model (12.19 ± 1.8 mm vs 8.99 ± 2.1 mm; P <.001), whereas lesion depth was similar between the thigh and heart (5.71 ± 0.8 mm vs 5.95 ± 1.3 mm, respectively; P = .18). The planar cross-sectional lesion area was greater in the thigh model (thigh 54.8 ± 10.8 mm2 vs heart 43.1 ± 16.1 mm2; P <.001). At the high-energy setting, lesion depth, width, and area were all greater in the thigh model (thigh 91.5 ± 16.8 mm2 vs heart 56.0 ± 15.5 mm2; P <.001). The incidence of steam pop and char formation was similar between the models. CONCLUSION: The thigh preparation model is a reasonable technique for evaluation of ablation catheter technology; however it often results in overestimation of lesion size, especially at higher energy settings.


Assuntos
Arritmias Cardíacas/cirurgia , Cateteres Cardíacos , Ablação por Cateter/métodos , Ventrículos do Coração/fisiopatologia , Músculo Esquelético/fisiopatologia , Animais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Estudos Transversais , Modelos Animais de Doenças , Impedância Elétrica , Desenho de Equipamento , Ventrículos do Coração/patologia , Teste de Materiais , Suínos , Irrigação Terapêutica/métodos
17.
Heart Rhythm ; 13(10): 2048-55, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27262767

RESUMO

BACKGROUND: Rhythmia is a new technology capable of rapid and high-resolution mapping. However, its potential advantage over existing technologies in mapping complex scar-related atrial tachycardias (ATs) has not yet been evaluated. OBJECTIVE: The purpose of this study was to examine the utility of Rhythmia for mapping scar-related ATs in patients who had failed previous ablation procedure(s). METHODS: This multicenter study included 20 patients with recurrent ATs within 2 years after a previous ablation procedure (1.8 ± 0.7 per patient). In all cases, the ATs could not be adequately mapped during the index procedure because of scar with fractionated electrograms, precluding accurate time annotation, frequent change in the tachycardia in response to pacing, and/or degeneration into atrial fibrillation. These patients underwent repeat mapping and ablation procedure with Rhythmia. RESULTS: From a total of 28 inducible ATs, 24 were successfully mapped. Eighteen ATs (75%) terminated during radiofrequency ablation and 4 (16.6%) with catheter pressure or entrainment from the site of origin or isthmus. Two ATs that were mapped to the interatrial septum slowed but did not terminate with ablation. In 21 of 24 ATs the mechanism was macroreentry, while in 3 of 24 the mechanism was focal. Interestingly, in 5 patients with previously failed ablation of an allegedly "focal" tachycardia, high-resolution mapping demonstrated macroreentrant arrhythmia. The mean mapping time was 28.6 ± 17 minutes, and the mean radiofrequency ablation time to arrhythmia termination was 3.2 ± 2.6 minutes. During a mean follow-up of 7.5 ± 3.1 months, 15 of 20 patients (75%) were free of AT recurrences. CONCLUSION: The Rhythmia mapping system may be advantageous for mapping complex scar-related ATs.


Assuntos
Ablação por Cateter , Cicatriz , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Supraventricular , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Cicatriz/complicações , Cicatriz/diagnóstico , Cicatriz/etiologia , Cicatriz/fisiopatologia , Precisão da Medição Dimensional , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Técnicas Eletrofisiológicas Cardíacas/métodos , Feminino , Sistema de Condução Cardíaco/patologia , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Cuidados Intraoperatórios/métodos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Estudos Prospectivos , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/patologia , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
19.
Europace ; 18(4): 521-30, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26311563

RESUMO

AIMS: To determine the incidence and risk factors for development of symptomatic heart failure (HF) following catheter ablation for atrial fibrillation (AF) and atrial flutter. METHODS AND RESULTS: We prospectively enrolled consecutive patients undergoing pulmonary vein isolation (PVI) or cavotricuspid isthmus (CTI) ablation between November 2013 and June 2014. Post-discharge symptoms were assessed via telephone follow-up and clinic visits. The primary outcome was symptomatic HF requiring treatment with new/increased diuretic dosing. Secondary outcomes were prolonged index hospitalization and readmission for HF ≤30 days. Univariate and multivariable logistic regressions were used to assess the relationship between patient/procedural characteristic and post-ablation HF. Among 111 PVI patients [median age 62.0 years; left ventricular ejection fraction (LVEF) 55%], 29 patients (26.1%) developed symptomatic HF, 6 patients (5.4%) required prolonged index hospitalization, and 8 patients (7.2%) were readmitted for HF. In univariate analyses, persistent AF [odds ratio (OR) 2.97, P = 0.02], AF at start of the procedure (OR 2.99, P = 0.01), additional ablation lines (OR 11.07, P < 0.0001), and final left atrial pressure (OR 1.10 per 1 mmHg increase, P = 0.02) were associated with HF development. Peri-procedural diuresis, net fluid balance, and LVEF were not correlated. In multivariable analyses, only additional ablation lines (ORadj 9.17, P = 0.007) were independently associated with post-ablation HF. Six patients (16.7%) developed HF after CTI ablation. CONCLUSION: A 26.1% of patients undergoing PVI and 16.7% of patients undergoing CTI ablation developed symptomatic HF when prospectively and uniformly assessed. 12.6% of patients experienced prolonged index hospitalizations or readmission for management of HF within 1 week after PVI. Improved understanding of risk factors for post-ablation HF may be critical in developing strategies to address during AF ablation.


Assuntos
Fibrilação Atrial/cirurgia , Flutter Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Insuficiência Cardíaca/epidemiologia , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Flutter Atrial/diagnóstico , Flutter Atrial/epidemiologia , Flutter Atrial/fisiopatologia , Boston/epidemiologia , Distribuição de Qui-Quadrado , Diuréticos/administração & dosagem , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/fisiopatologia , Humanos , Incidência , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Readmissão do Paciente , Estudos Prospectivos , Edema Pulmonar/epidemiologia , Veias Pulmonares/fisiopatologia , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
Heart Rhythm ; 12(9): 1927-34, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26001505

RESUMO

BACKGROUND: During pulmonary vein isolation (PVI), a circular lasso catheter is positioned at the junction between the left atrium (LA) and the pulmonary vein (PV) to confirm PVI. The Rhythmia mapping system uses the Orion mini-basket catheter with 64 electrodes instead of the lasso catheter. However, its feasibility to determine PVI has not been studied. OBJECTIVE: The purpose of this study was to compare signals between the mini-basket and lasso catheters at the LA-PV junction. METHODS: In 12 patients undergoing PVI using Rhythmia, the mini-basket and lasso catheters were placed simultaneously at the LA-PV junction for baseline and post-PVI signal assessment. Pacing from both catheters was performed to examine the presence of exit block. RESULTS: At baseline, recordings of LA and PV potentials were concordant in all PVs. However, after PVI, concordance between the catheters was only 68%. Discordance in all cases resulted from loss of PV potentials on the lasso catheter with persistence of PV potentials on the mini-basket catheter. In 9 of 13 PVs (69%), these potentials represented true PV potentials that were exclusively recorded with the smaller and closely spaced mini-basket electrodes. In the other 4 PVs (31%), these potentials originated from neighboring structures and resulted in underestimation of PVI. CONCLUSION: The use of the mini-basket catheter alone is sufficient to determine PVI. While it improves recording of PV potentials after incomplete ablation, it is also associated with frequent recording of "PV-like" potentials originating from neighboring structures. In these cases, pacing maneuvers are helpful to determine PVI and avoid excessive ablation.


Assuntos
Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/instrumentação , Cateterismo Cardíaco/instrumentação , Catéteres , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Fibrilação Atrial/fisiopatologia , Ablação por Cateter , Desenho de Equipamento , Feminino , Seguimentos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Miniaturização , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...