Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Electrophoresis ; 43(3): 456-463, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34661921

RESUMO

Headspace (HS) extraction is a sample pretreatment technique for volatile and semivolatile organic compounds in a complex matrix. Recently, in-tube microextraction (ITME) coupled with CE using an acceptor plug placed in the capillary inlet was developed as a simple but powerful HS extraction method. Here, we present single bubble (SB) ITME using a bubble hanging to the capillary inlet immersed in a sample donor solution as a HS of submicroliter volume (∼200 nL). The analytes evaporated to the bubble were extracted into the acceptor phase through the capillary opening, then electrophoresis of the enriched extract was carried out. Since the bubble volume was much smaller than a conventional HS volume (∼1 mL), it was filled with the evaporated analytes rapidly and the analytes could be enriched much faster compared to conventional HS-ITME. Owing to the high surface-to-volume ratio of the SB, 5 min SB-ITME yielded the enrichment factor values similar to those of 10 min HS-ITME. When 5 min SB-ITME at room temperature was applied to a tap water sample, the enrichment factors of 2,4,6-trichlorophenol (TCP), 2,3,6-TCP, and 2,6-dichlorophenol were 53, 41, and 60, respectively, and the LOQs obtained by monitoring the absorbance at 214 nm were 5.6-8.3 ppb, much lower than 200 ppb, the World Health Organization guideline for the maximum permissible concentration of 2,4,6-TCP in drinking water.


Assuntos
Clorofenóis , Água Potável , Microextração em Fase Líquida , Poluentes Químicos da Água , Clorofenóis/análise , Eletroforese Capilar/métodos , Compostos Orgânicos/análise , Poluentes Químicos da Água/análise
2.
J Chromatogr A ; 1655: 462520, 2021 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-34517164

RESUMO

A high-performance version of in-line, three-phase direct immersion-single drop microextraction (DI-SDME) coupled with capillary electrophoresis (CE) was demonstrated using a commercial CE instrument, and all the major and minor details were described to provide an easy-to-follow and user-friendly protocol. The excellent sample cleanup and enrichment power of this method was demonstrated with nonsteroidal anti-inflammatory drugs (NSAIDs) in human urine. The only preparation of urine samples was the addition of HCl to acidify the urine sample to pH 2. The acidic NSAIDs in the acidified urine sample were extracted into a basic acceptor drop covered with a thin organic layer attached to the inlet tip of a capillary immersed in the sample. A simple but powerful DI-SDME-CE method could be carried out automatically without any modification of the existing CE instrument. For improved performance, sample agitation and heating were employed by installing a microstirrer and a thermostating jacket in the sample tray. With 10 min of DI-SDME at 35°C with stirring, NSAIDs such as ketoprofen, ibuprofen, and naproxen in urine were enriched 340-970-fold with intraday and interday RSDs of 0.8-2.4% and 1.1-3.6%, respectively. The LODs obtained with in-line coupled CE/UV were 10-50 nM (2-10 µg/L). The performance of DI-SDME-CE/UV was also demonstrated by determining the naproxen level in human urine collected 24 h after taking a single oral dose of the drug. The spike recovery of naproxen from a single-point standard addition to the urine sample was 80%. Our high-performance three-phase DI-SDME-CE method is quite promising for the analysis of ionizable trace analytes in a complex sample matrix.


Assuntos
Eletroforese Capilar , Cetoprofeno , Anti-Inflamatórios não Esteroides , Humanos , Ibuprofeno , Naproxeno
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA