1.
Gynecol Oncol ; 187: 113-119, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38759517

RESUMO

OBJECTIVE: The majority of high-grade serous carcinomas (HGSC) of the ovary, fallopian tube, and peritoneum arise from the precursor lesion called serous tubal intraepithelial carcinoma (STIC). It has been postulated that cells from STICs exfoliate into the peritoneal cavity and give rise to peritoneal HGSC several years later. While co-existent STICs and HGSCs have been reported to share similarities in their mutational profiles, clonal relationship between temporally distant STICs and HGSCs have been infrequently studied and the natural history of STICs remains poorly understood. METHODS: We performed focused searches in two national databases from the Netherlands and identified a series of BRCA1/2 germline pathogenic variant (GPV) carriers (n = 7) who had STIC, and no detectable invasive carcinoma, at the time of their risk-reducing salpingo-oophorectomy (RRSO), and later developed peritoneal HGSC. The clonal relationship between these STICs and HGSCs was investigated by comparing their genetic mutational profile by performing next-generation targeted sequencing. RESULTS: Identical pathogenic mutations and loss of heterozygosity of TP53 were identified in the STICs and HGSCs of five of the seven patients (71%), confirming the clonal relationship of the lesions. Median interval for developing HGSC after RRSO was 59 months (range: 24-118 months). CONCLUSION: Our results indicate that cells from STIC can shed into the peritoneal cavity and give rise to HGSC after long lag periods in BRCA1/2 GPV carriers, and argues in favor of the hypothesis that STIC lesions may metastasize.

2.
Tijdschr Psychiatr ; 66(2): 70-75, 2024.
Artigo em Holandês | MEDLINE | ID: mdl-38512144

RESUMO

Background The prevalence of smoking among patients with psychiatric disorders is 3-4 times higher than the general population. However, smoking is still permitted in many psychiatric clinics. The National Prevention Agreement (2018) mandates that all psychiatric wards be smoke-free by 2025. The UMC Utrecht clinics have been smoke-free since November 2020. Aim To examine healthcare workers’ attitudes before and after implementing the smoke-free policy. Method In an observational study with quantitative data analysis, data were collected in one center from healthcare workers in psychiatry departments with surveys. We collected demographic information, smoking status, attitudes towards the smoke-free policy, and its impact on patients and care. Incidents of aggression were prospectively recorded and reported in the MAP (aggression incidents in patient care). Results Out of 172 healthcare workers invited to participate, 30% (n = 52) completed the pre-implementation survey, and 20% (n = 34) completed the post-implementation survey. Prior to implementation, 62% (n = 32/52) of healthcare workers had a positive attitude towards the smoke-free policy, which increased to 77% (n = 26/34) post-implementation. Expectations of increased aggression incidents were reported by 62% (n = 32/52) during the pre-implementation phase. The number of aggression incidents was 46 in the one-year period before implementation (November 2019 – February 2020) and 45 incidents after implementation (November 2020 – February 2021). Conclusion This study supports the implementation of a smoke-free policy in psychiatric clinics due to the lack of a significant increase in aggression incidents. Healthcare workers perceived this outcome and observed quicker granting of ‘green’ freedoms.


Assuntos
Psiquiatria , Política Antifumo , Humanos , Agressão , Atitude do Pessoal de Saúde , Pessoal de Saúde
3.
Bone Rep ; 20: 101738, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38292932

RESUMO

Background: Abnormalities of the hyoid bone are associated with impairment of oropharyngeal functions including feeding, swallowing, and breathing. Few studies have characterized anatomic abnormalities of the hyoid in patients with Robin sequence (RS), e.g. a less mineralized and voluminous hyoid. The purpose of this study was to compare normal hyoid bone morphology and hyoid bone morphology in children with isolated RS. Methods: Three-dimensional (3D) reconstructions of the hyoid bone were obtained from CT-imaging of children with RS and unaffected controls. A 3D morphable model was constructed using Principal Component Analysis (PCA). Partial least squares - Discriminant Analysis (PLS-DA) and multivariate analysis of variance (MANOVA) were used to characterize and compare hyoid shape differences between patients with RS and an age-matched control group. Results: The study included 23 subjects with RS (mean age 9.8 ± 10.3 months) and 46 age-matched control samples. A less voluminous hyoid was observed for the RS group with a larger lateral divergence of the greater horns compared to controls (MANOVA, p-value<0.001). The first shape variable from the PLS-DA model showed a significant correlation for the observed variance between the two groups (Spearman R = -0.56, p-value<0.001). The control samples and 151 CT-scans of subjects up to age 4 years were used to create a 3D morphable model of normal hyoid shape variation (n = 197, mean age 22.1 ± 13.1 months). For the normal 3D morphable model, a high degree of allometric shape variation was observed along the first principal component. Conclusions: The 3D morphable models provide a comprehensive and quantitative description of variation in normal hyoid bone morphology, and allow detection of distinct differences between patients with isolated RS and controls.

4.
Magn Reson Med ; 91(3): 1190-1199, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37876351

RESUMO

PURPOSE: Several reconstruction methods for MR-based electrical properties tomography (EPT) have been developed. However, the lack of common data makes it difficult to objectively compare their performances. This is, however, a necessary precursor for standardizing and introducing this technique in the clinical setting. To enable objective comparison of the performances of reconstruction methods and provide common data for their training and testing, we created ADEPT, a database of simulated data for brain MR-EPT reconstructions. METHODS: ADEPT is a database containing in silico data for brain EPT reconstructions. This database was created from 25 different brain models, with and without tumors. Rigid geometric augmentations were applied, and different electrical properties were assigned to white matter, gray matter, CSF, and tumors to generate 120 different brain models. These models were used as input for finite-difference time-domain simulations in Sim4Life, used to compute the electromagnetic fields needed for MR-EPT reconstructions. RESULTS: Electromagnetic fields from 84 healthy and 36 tumor brain models were simulated. The simulated fields relevant for MR-EPT reconstructions (transmit and receive RF fields and transceive phase) and their ground-truth electrical properties are made publicly available through ADEPT. Additionally, nonattainable fields such as the total magnetic field and the electric field are available upon request. CONCLUSION: ADEPT will serve as reference database for objective comparisons of reconstruction methods and will be a first step toward standardization of MR-EPT reconstructions. Furthermore, it provides a large amount of data that can be exploited to train data-driven methods. It can be accessed from  https://doi.org/10.34894/V0HBJ8.


Assuntos
Processamento de Imagem Assistida por Computador , Neoplasias , Humanos , Condutividade Elétrica , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Tomografia/métodos , Imagens de Fantasmas , Algoritmos
5.
Microsc Res Tech ; 87(3): 495-505, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37929605

RESUMO

Pluripotent stem cell-derived kidney organoids hold great promise as a potential auxiliary transplant tissue for individuals with end-stage renal disease and as a platform for studying kidney diseases and drug discovery. To establish accurate models, it is crucial to thoroughly characterize the morphological features and maturation stages of the cellular components within these organoids. Nephrons, the functional units of the kidney, possess distinct morphological structures that directly correlate with their specific functions. High spatial resolution imaging emerges as a powerful technique for capturing ultrastructural details that may go unnoticed with other methods such as immunofluorescent imaging and scRNA sequencing. In our study, we have applied software capable of seamlessly stitching virtual slides generated from electron microscopy, resulting in high-definition overviews of tissue slides. With this technology, we can comprehensively characterize the development and maturation of kidney organoids when transplanted under the renal capsule of mice. These organoids exhibit advanced ultrastructural developments upon transplantation, including the formation of the filtration barrier in the renal corpuscle, the presence of microvilli in the proximal tubule, and various types of cell sub-segmentation in the connecting tubule similarly to those seen in the adult kidney. Such ultrastructural characterization provides invaluable insights into the structural development and functional morphology of nephron segments within kidney organoids and how to advance them by interventions such as a transplantation. Research Highlights High-resolution imaging is crucial to determine morphological maturation of hiPSC-derived kidney organoids. Upon transplantation, refined ultrastructural development of nephron segments was observed, such as the development of the glomerular filtration barrier.


Assuntos
Células-Tronco Pluripotentes Induzidas , Células-Tronco Pluripotentes , Animais , Camundongos , Diferenciação Celular , Néfrons/metabolismo , Rim/ultraestrutura
7.
Front Pharmacol ; 13: 900551, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35837288

RESUMO

Introduction: Protein binding can diminish the pharmacological effect of beta-lactam antibiotics. Only the free fraction has an antibacterial effect. The aim of this systematic literature review was to give an overview of the current knowledge of protein binding of cephalosporins in human body fluids as well as to describe patient characteristics influencing the level of protein binding. Method: A systematic literature search was performed in Embase, Medline ALL, Web of Science Core Collection and the Cochrane Central Register of Controlled Trials with the following search terms: "protein binding," "beta-lactam antibiotic," and "body fluid." Only studies were included where protein binding was measured in humans in vivo. Results: The majority of studies reporting protein binding were performed in serum or plasma. Other fluids included pericardial fluid, blister fluid, bronchial secretion, pleural exudate, wound exudate, cerebrospinal fluid, dialysate, and peritoneal fluid. Protein binding differs between diverse cephalosporins and between different patient categories. For cefazolin, ceftriaxone, cefpiramide, and cefonicid a non-linear pattern in protein binding in serum or plasma was described. Several patient characteristics were associated with low serum albumin concentrations and were found to have lower protein binding compared to healthy volunteers. This was for critically ill patients, dialysis patients, and patients undergoing cardiopulmonary bypass during surgery. While mean/median percentages of protein binding are lower in these patient groups, individual values may vary considerably. Age is not likely to influence protein binding by itself, however limited data suggest that lower protein binding in newborns. Obesity was not correlated with altered protein binding. Discussion/Conclusion: Conclusions on protein binding in other body fluids than blood cannot be drawn due to the scarcity of data. In serum and plasma, there is a large variability in protein binding per cephalosporin and between different categories of patients. Several characteristics were identified which lead to a lower protein binding. The finding that some of the cephalosporins display a non-linear pattern of protein binding makes it even more difficult to predict the unbound concentrations in individual patients. Taken all these factors, it is recommended to measure unbound concentrations to optimize antibiotic exposure in individual patients. Systematic Review Registration: PROSPERO, identifier (CRD42021252776).

8.
Tijdschr Psychiatr ; 63(11): 775-781, 2021.
Artigo em Holandês | MEDLINE | ID: mdl-34851516

RESUMO

BACKGROUND: Conspiracy theories are popular during the COVID-19 pandemic. Conspiratorial thinking is characterised by the strong conviction that a certain situation that one sees as unjust is the result of a deliberate conspiracy of a group of people with bad intentions. Conspiratorial thinking appears to have many similarities with paranoid delusions. AIM: To explore the nature, consequences, and social-psychological dimensions of conspiratorial thinking, and describe similarities and differences with paranoid delusions. METHOD: Critically assessing relevant literature about conspiratorial thinking and paranoid delusions. RESULTS: Conspiratorial thinking meets epistemic, existential, and social needs. It provides clarity in uncertain times and connection with an in-group of like-minded people. Both conspiratorial thinking and paranoid delusions involve an unjust, persistent, and sometimes bizarre conviction. Unlike conspiracy theorists, people with a paranoid delusion are almost always the only target of the presumed conspiracy, and they usually stand alone in their conviction. Furthermore, conspiracy theories are not based as much on unusual experiences of their inner self, reality, or interpersonal contacts. CONCLUSIONS Conspirational thinking is common in uncertain circumstances. It gives grip, certainty, moral superiority and social support. Extreme conspirational thinking seems to fit current psychiatric definitions of paranoid delusions, but there are also important differences. To make a distinction with regard to conspiratorial thinking, deepening of conventional definitions of delusions is required. Instead of the strong focus on the erroneous content of delusions, more attention should be given to the underlying idiosyncratic, changed way of experiencing reality.


Assuntos
COVID-19 , Transtornos Mentais , Delusões , Humanos , Pandemias , SARS-CoV-2
9.
Ned Tijdschr Tandheelkd ; 128(11): 539-541, 2021 Nov.
Artigo em Holandês | MEDLINE | ID: mdl-34747163

RESUMO

Green tooth discoloration can have several causes. From the patient history of the two-year-old with green tooth discoloration clear causal relationships can be identified. The pathological cause is an increase in bilirubin levels for an extended period of time. Determining the extent of tooth development in combination with the increase in bilirubin levels makes it possible to estimate the degree and pattern of green tooth discoloration. If the increase in bilirubin levels is short-lived, it is possible the permanent dentition will not be affected.


Assuntos
Descoloração de Dente , Pré-Escolar , Dentição Permanente , Humanos , Masculino , Odontogênese , Descoloração de Dente/diagnóstico , Descoloração de Dente/etiologia
10.
J Psychiatr Res ; 143: 183-188, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34500347

RESUMO

BACKGROUND: Results of research regarding a possible causal relation between autism spectrum disorders (ASDs) and violence are mixed. Several explanations have been proposed. AIMS: To assess prevalence rates of comorbid disorders in a large sample of mentally ill offenders diagnosed with ASD. Offenders with and without comorbid mental disorders were compared on several characteristics. To better understand the relationship between ASD and violent criminal behavior, the predictive value of several proposed risk factors (comorbidity, negative social network/influenceability, and childhood trauma/victimization) on violent offending was investigated. METHOD: Data of 394 male offenders with a diagnosis of ASD were included. Prevalence rates of comorbid mental disorders next to ASD were calculated, and characteristics were compared using chi-square or t-tests. The predictive value of the risk factors was assessed using a binary logistic regression (n = 357). RESULTS: High rates of comorbidity were found (78.9%), specifically for substance use disorders (39.8%), schizophrenia spectrum disorders (31.7%), and neurodevelopmental disorder other than ASD (24.1%). Offenders with and without comorbidity differed significantly in their criminal and mental health care history. Both comorbidity (OR = 1.68; 95% CI 1.27-2.18) and a negative social network/influenceability (OR = 1.49; 95% CI 1.11-1.99) showed to be significant predictors of violent offending within this sample. CONCLUSIONS: The highest rates of comorbid disorders found were disorders that have been previously linked to violent offending, and the risk of violent offending could be unrelated to ASD. However, the role of social functioning indicates a risk specific to the symptoms of ASD.


Assuntos
Transtorno do Espectro Autista , Transtornos Mentais , Pessoas Mentalmente Doentes , Prisioneiros , Transtornos Relacionados ao Uso de Substâncias , Transtorno do Espectro Autista/epidemiologia , Humanos , Masculino , Transtornos Mentais/epidemiologia , Fatores de Risco , Violência
11.
Phys Med Biol ; 65(22): 22NT01, 2020 11 12.
Artigo em Inglês | MEDLINE | ID: mdl-32977318

RESUMO

Hybrid MRI-linac (MRL) systems enable daily multiparametric quantitative MRI to assess tumor response to radiotherapy. Magnetic resonance fingerprinting (MRF) may provide time efficient means of rapid multiparametric quantitative MRI. The accuracy of MRF, however, relies on adequate control over system imperfections, such as eddy currents and [Formula: see text], which are different and not as well established on MRL systems compared to diagnostic systems. In this study we investigate the technical feasibility of gradient spoiled 2D MRF on a 1.5T MRL. We show with phantom experiments that the MRL generates reliable MRF signals that are temporally stable during the day and have good agreement with spin-echo reference measurements. Subsequent in-vivo MRF scans in healthy volunteers and a patient with a colorectal liver metastasis showed good image quality, where the quantitative values of selected organs corresponded with the values reported in literature. Therefore we conclude that gradient spoiled 2D MRF is feasible on a 1.5T MRL with similar performance as on a diagnostic system. The precision and accuracy of the parametric maps are sufficient for further investigation of the clinical utility of MRF for online quantitatively MRI-guided radiotherapy.


Assuntos
Encéfalo/anatomia & histologia , Neoplasias Colorretais/patologia , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/secundário , Imageamento por Ressonância Magnética Multiparamétrica/métodos , Imagens de Fantasmas , Estudos de Viabilidade , Voluntários Saudáveis , Humanos , Reprodutibilidade dos Testes
12.
Phys Med Biol ; 65(12): 12NT01, 2020 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-32330921

RESUMO

Motion is problematic during radiotherapy as it could lead to potential underdosage of the tumor, and/or overdosage in organs-at-risk. A solution is adaptive radiotherapy guided by magnetic resonance imaging (MRI). MRI allows for imaging of target volumes and organs-at-risk before and during treatment delivery with superb soft tissue contrast in any desired orientation, enabling motion management by means of (real-time) adaptive radiotherapy. The noise navigator, which is independent of the MR signal, could serve as a secondary motion detection method in synergy with MR imaging. The feasibility of respiratory motion detection by means of the noise navigator was demonstrated previously. Furthermore, from electromagnetic simulations we know that the noise navigator is sensitive to tissue displacement and thus could in principle be used for the detection of various types of motion. In this study we demonstrate the detection of various types of motion for three anatomical use cases of MRI-guided radiotherapy, i.e. torso (bulk movement and variable breathing), head-and-neck (swallowing) and cardiac. Furthermore, it is shown that the noise navigator can detect bulk movement, variable breathing and swallowing on a hybrid 1.5 T MRI-linac system. Cardiac activity detection through the noise navigator seems feasible in an MRI-guided radiotherapy setting, but needs further optimization. The noise navigator is a versatile and fast (millisecond temporal resolution) motion detection method independent of MR signal that could serve as an independent verification method to detect the occurrence of motion in synergy with real-time MRI-guided radiotherapy.


Assuntos
Imageamento por Ressonância Magnética , Movimentos dos Órgãos , Radioterapia Guiada por Imagem/métodos , Humanos , Órgãos em Risco/efeitos da radiação , Aceleradores de Partículas , Radioterapia Guiada por Imagem/efeitos adversos , Razão Sinal-Ruído
13.
Pregnancy Hypertens ; 19: 150-158, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32007784

RESUMO

OBJECTIVES: In a previous mass spectrometry study of our research group, 25 proteins were found to be differentially expressed in cerebrospinal fluid of patients with preeclampsia compared to controls. The objective of the current study was to investigate DNA methylation of the genes encoding for the former mentioned proteins in an independent dataset. STUDY DESIGN: In a nested case-control study of the Rotterdam Periconceptional Cohort, placental tissue, umbilical cord white blood cells and human umbilical vein endothelial cells (HUVEC) were obtained of 13 patients with early-onset preeclampsia, 16 patients with late-onset preeclampsia and 83 normotensive controls (27 patients with fetal growth restriction, 20 patients with spontaneous preterm birth and 36 uncomplicated pregnancies). DNA methylation of 783 CpGs in regions of 25 genes was measured. MAIN OUTCOME MEASURES: DNA methylation of selected candidate genes in early- and late-onset preeclampsia compared to fetal growth restriction, spontaneous preterm birth and uncomplicated controls. RESULTS: From the 783 CpGs of the 25 selected genes, 15 CpGs were differentially methylated between early-onset preeclampsia and spontaneous preterm birth (3.80 E-5 ≤ p ≤ 0.036). Four CpGs were differentially methylated between early-onset preeclampsia and fetal growth restriction (0.0002 ≤ p ≤ 0.037) and 13 CpGs were differentially methylated between early onset preeclampsia and uncomplicated controls (0.0001 ≤ p ≤ 0.04). CONCLUSION: Differences in DNA methylation were found in placental tissue, umbilical cord white blood cells and HUVEC of patients with early onset preeclampsia compared to (un)complicated controls, but not in patients with late-onset preeclampsia. The genes showing the largest differential methylation encode insulin-like growth factor 2 binding protein and receptor and cadherin 13.


Assuntos
Caderinas/genética , Metilação de DNA , Fator de Crescimento Insulin-Like II/genética , Pré-Eclâmpsia/genética , Adulto , Estudos de Casos e Controles , Ilhas de CpG , Células Endoteliais/metabolismo , Feminino , Sangue Fetal/citologia , Retardo do Crescimento Fetal/genética , Humanos , Leucócitos/metabolismo , Placenta/metabolismo , Gravidez , Nascimento Prematuro/genética , Veias Umbilicais/citologia
14.
Magn Reson Med ; 83(2): 695-711, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31483521

RESUMO

PURPOSE: Local specific absorption rate (SAR) cannot be measured and is usually evaluated by offline numerical simulations using generic body models that of course will differ from the patient's anatomy. An additional safety margin is needed to include this intersubject variability. In this work, we present a deep learning-based method for image-based subject-specific local SAR assessment. We propose to train a convolutional neural network to learn a "surrogate SAR model" to map the relation between subject-specific B1+ maps and the corresponding local SAR. METHOD: Our database of 23 subject-specific models with an 8-transmit channel body array for prostate imaging at 7 T was used to build 5750 training samples. These synthetic complex B1+ maps and local SAR distributions were used to train a conditional generative adversarial network. Extra penalization for local SAR underestimation errors was included in the loss function. In silico and in vivo validation were performed. RESULTS: In silico cross-validation shows a good qualitative and quantitative match between predicted and ground-truth local SAR distributions. The peak local SAR estimation error distribution shows a mean overestimation error of 15% with 13% probability of underestimation. The higher accuracy of the proposed method allows the use of less conservative safety factors compared with standard procedures. In vivo validation shows that the method is applicable with realistic measurement data with impressively good qualitative and quantitative agreement to simulations. CONCLUSION: The proposed deep learning method allows online image-based subject-specific local SAR assessment. It greatly reduces the uncertainty in current state-of-the-art SAR assessment methods, reducing the time in the examination protocol by almost 25%.


Assuntos
Aprendizado Profundo , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Algoritmos , Simulação por Computador , Bases de Dados Factuais , Voluntários Saudáveis , Humanos , Masculino , Modelos Estatísticos , Redes Neurais de Computação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Razão Sinal-Ruído
15.
Phys Med Biol ; 65(1): 01NT02, 2020 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-31775130

RESUMO

Respiratory-correlated 4D-MRI can characterize respiratory-induced motion of tumors and organs-at-risk for radiotherapy treatment planning and is a necessity for image guidance of moving tumors treated on an MRI-linac. Essential for 4D-MRI generation is a robust respiratory surrogate signal. We investigated the feasibility of the noise navigator as respiratory surrogate signal for 4D-MRI generation. The noise navigator is based on the respiratory-induced modulation of the thermal noise variance measured by the receive coils during MR acquisition and thus is inherently present and synchronized with MRI data acquisition. Additionally, the noise navigator can be combined with any rectilinear readout strategy (e.g. radial and cartesian) and is independent of MR image contrast and imaging orientation. For radiotherapy applications, the noise navigator provides a robust respiratory signal for patients scanned with an elevated coil setup. This is particularly attractive for widely used cartesian sequences where currently a non-interfering self-navigation means is lacking for MRI-based simulation and MRI-guided radiotherapy. The feasibility of 4D-MRI generation with the noise navigator as respiratory surrogate signal was demonstrated for both cartesian and radial readout strategies in radiotherapy setup on four healthy volunteers and two radiotherapy patients on a dedicated 1.5 T MRI scanner and two radiotherapy patients on a 1.5 T MRI-linac system. Moreover, the respiratory-correlated 4D-MR images showed liver motion comparable to a reference 2D cine MRI series for the volunteers. For 2D cartesian cine MRI acquisitions, both the noise navigator and respiratory bellows were benchmarked against an image navigator. Respiratory phase detection based on the noise navigator agreed 1.4 times better with the image navigator than the respiratory bellows did. For a 3D Stack-of-Stars acquisitions, the noise navigator was compared to radial self-navigation and a 1.7 times higher respiratory phase detection agreement was observed than for the respiratory bellows compared to radial self-navigation.


Assuntos
Fígado/efeitos da radiação , Neoplasias Pulmonares/patologia , Imageamento por Ressonância Magnética/métodos , Órgãos em Risco/efeitos da radiação , Neoplasias Pancreáticas/patologia , Respiração , Técnicas de Imagem de Sincronização Respiratória/métodos , Razão Sinal-Ruído , Voluntários Saudáveis , Humanos , Imageamento Tridimensional/métodos , Neoplasias Pulmonares/radioterapia , Movimento , Neoplasias Pancreáticas/radioterapia , Aceleradores de Partículas
16.
Med Phys ; 47(3): 1238-1248, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31876300

RESUMO

PURPOSE: To quickly and automatically propagate organ contours from pretreatment to fraction images in magnetic resonance (MR)-guided prostate external-beam radiotherapy. METHODS: Five prostate cancer patients underwent 20 fractions of image-guided external-beam radiotherapy on a 1.5 T MR-Linac system. For each patient, a pretreatment T2-weighted three-dimensional (3D) MR imaging (MRI) scan was used to delineate the clinical target volume (CTV) contours. The same scan was repeated during each fraction, with the CTV contour being manually adapted if necessary. A convolutional neural network (CNN) was trained for combined image registration and contour propagation. The network estimated the propagated contour and a deformation field between the two input images. The training set consisted of a synthetically generated ground truth of randomly deformed images and prostate segmentations. We performed a leave-one-out cross-validation on the five patients and propagated the prostate segmentations from the pretreatment to the fraction scans. Three variants of the CNN, aimed at investigating supervision based on optimizing segmentation overlap, optimizing the registration, and a combination of the two were compared to results of the open-source deformable registration software package Elastix. RESULTS: The neural networks trained on segmentation overlap or the combined objective achieved significantly better Hausdorff distances between predicted and ground truth contours than Elastix, at the much faster registration speed of 0.5 s. The CNN variant trained to optimize both the prostate overlap and deformation field, and the variant trained to only maximize the prostate overlap, produced the best propagation results. CONCLUSIONS: A CNN trained on maximizing prostate overlap and minimizing registration errors provides a fast and accurate method for deformable contour propagation for prostate MR-guided radiotherapy.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Redes Neurais de Computação , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radioterapia Guiada por Imagem , Fracionamento da Dose de Radiação , Humanos , Masculino , Fatores de Tempo
17.
Phys Med Biol ; 65(2): 025012, 2020 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-31842008

RESUMO

To investigate the dosimetric impact of intrafraction translation and rotation motion of the prostate, as extracted from daily acquired post-treatment 3D cine-MR based on soft-tissue contrast, in extremely hypofractionated (SBRT) prostate patients. Accurate dose reconstruction is performed by using a prostate intrafraction motion trace which is obtained with a soft-tissue based rigid registration method on 3D cine-MR dynamics with a temporal resolution of 11 s. The recorded motion of each time-point was applied to the planning CT, resulting in the respective dynamic volume used for dose calculation. For each treatment fraction, the treatment delivery record was generated by proportionally splitting the plan into 11 s intervals based on the delivered monitor units. For each fraction the doses of all partial plan/dynamic volume combinations were calculated and were summed to lead to the motion-affected fraction dose. Finally, for each patient the five fraction doses were summed, yielding the total treatment dose. Both daily and total doses were compared to the original reference dose of the respective patient to assess the impact of the intrafraction motion. Depending on the underlying motion of the prostate, different types of motion-affected dose distributions were observed. The planning target volumes (PTVs) ensured CTV_30 (seminal vesicles) D99% coverage for all patients, CTV_35 (prostate corpus) coverage for 97% of the patients and GTV_50 (local boost) for 83% of the patients when compared against the strict planning target D99% value. The dosimetric impact due to prostate intrafraction motion in extremely hypofractionated treatments was determined. The presented study is an essential step towards establishing the actual delivered dose to the patient during radiotherapy fractions.


Assuntos
Fracionamento da Dose de Radiação , Imageamento Tridimensional , Movimento , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radiocirurgia/métodos , Algoritmos , Humanos , Masculino , Radiometria , Planejamento da Radioterapia Assistida por Computador , Rotação
18.
Phys Med Biol ; 64(23): 235008, 2019 12 05.
Artigo em Inglês | MEDLINE | ID: mdl-31698351

RESUMO

To develop a method to automatically determine intrafraction motion of the prostate based on soft tissue contrast on 3D cine-magnetic resonance (MR) images with high spatial and temporal resolution. Twenty-nine patients who underwent prostate stereotactic body radiotherapy (SBRT), with four implanted cylindrical gold fiducial markers (FMs), had cine-MR imaging sessions after each of five weekly fractions. Each cine-MR session consisted of 55 sequentially obtained 3D data sets ('dynamics') and was acquired over an 11 s period, covering a total of 10 min. The prostate was delineated on the first dynamic of every dataset and this delineation was used as the starting position for the soft tissue tracking (SST). Each subsequent dynamic was rigidly aligned to the first dynamic, based on the contrast of the prostate. The obtained translation and rotation describes the intrafraction motion of the prostate. The algorithm was applied to 6270 dynamics over 114 scans of 29 patients and the results were validated by comparing to previously obtained fiducial marker tracking data of the same dataset. Our proposed tracking method was also retro-perspectively applied to cine-MR images acquired during MR-guided radiotherapy of our first prostate patient treated on the MR-Linac. The difference in the 3D translation results between the soft tissue and marker tracking was below 1 mm for 98.2% of the time. The mean translation at 10 min were X: 0.0 [Formula: see text] 0.8 mm, Y: 1.0 [Formula: see text] 1.8 mm and Z: [Formula: see text] mm. The mean rotation results at 10 min were X: [Formula: see text], Y: 0.1 [Formula: see text] 0.6° and Z: 0.0 [Formula: see text] 0.7°. A fast, robust and accurate SST algorithm was developed which obviates the need for FMs during MR-guided prostate radiotherapy. To our knowledge, this is the first data using full 3D cine-MR images for real-time soft tissue prostate tracking, which is validated against previously obtained marker tracking data.


Assuntos
Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Neoplasias da Próstata/radioterapia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Algoritmos , Marcadores Fiduciais , Humanos , Imageamento Tridimensional/normas , Imagem Cinética por Ressonância Magnética/normas , Masculino , Movimento , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Radiocirurgia/normas , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia Guiada por Imagem/normas , Rotação
19.
Magn Reson Med ; 82(6): 2236-2247, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31317566

RESUMO

PURPOSE: The noise navigator is a passive way to detect physiological motion occurring in a patient through thermal noise modulations measured by standard clinical radiofrequency receive coils. The aim is to gain a deeper understanding of the potential and applications of physiologically induced thermal noise modulations. METHODS: Numerical electromagnetic simulations and MR measurements were performed to investigate the relative contribution of tissue displacement versus modulation of the dielectric lung properties over the respiratory cycle, the impact of coil diameter and position with respect to the body. Furthermore, the spatial motion sensitivity of specific noise covariance matrix elements of a receive array was investigated. RESULTS: The influence of dielectric lung property variations on the noise variance is negligible compared to tissue displacement. Coil size affected the thermal noise variance modulation, but the location of the coil with respect to the body had a larger impact. The modulation depth of a 15 cm diameter stationary coil approximately 3 cm away from the chest (i.e. radiotherapy setup) was 39.7% compared to 4.2% for a coil of the same size on the chest, moving along with respiratory motion. A combination of particular noise covariance matrix elements creates a specific spatial sensitivity for motion. CONCLUSIONS: The insight gained on the physical relations governing the noise navigator will allow for optimized use and development of new applications. An optimized combination of elements from the noise covariance matrix offer new ways of performing, e.g. motion tracking.


Assuntos
Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Movimento (Física) , Simulação por Computador , Radiação Eletromagnética , Voluntários Saudáveis , Humanos , Masculino , Músculos/diagnóstico por imagem , Imagens de Fantasmas , Ondas de Rádio , Radioterapia , Razão Sinal-Ruído , Pele/diagnóstico por imagem
20.
Phys Med Biol ; 64(7): 07NT02, 2019 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-30794995

RESUMO

We have developed a method to determine intrafraction motion of the prostate through automatic fiducial marker (FM) tracking on 3D cine-magnetic resonance (MR) images with high spatial and temporal resolution. Twenty-nine patients undergoing prostate stereotactic body radiotherapy (SBRT), with four implanted cylindrical gold FMs, had cine-MR imaging sessions after each of five weekly fractions. Each cine-MR examination consisted of 55 sequentially obtained 3D datasets ('dynamics'), acquired over a 11 s period, covering a total of 10 min. FM locations in the first dynamic were manually identified by a clinician, FM centers in subsequent dynamics were automatically determined. Center of mass (COM) translations and rotations were determined by calculating the rigid transformations between the FM template of the first and subsequent dynamics. The algorithm was applied to 7315 dynamics over 133 scans of 29 patients and the obtained results were validated by comparing the COM locations recorded by the clinician at the halfway-dynamic (after 5 min) and end dynamic (after 10 min). The mean COM translations at 10 min were X: 0.0 [Formula: see text] 0.8 mm, Y: 1.0 [Formula: see text] 1.9 mm and Z: 0.9 [Formula: see text] 2.0 mm. The mean rotation results at 10 min were X: 0.1 [Formula: see text] 3.9°, Y: 0.0 [Formula: see text] 1.3° and Z: 0.1 [Formula: see text] 1.2°. The tracking success rate was 97.7% with a mean 3D COM error of 1.1 mm. We have developed a robust, fast and accurate FM tracking algorithm for cine-MR data, which allows for continuous monitoring of prostate motion during MR-guided radiotherapy (MRgRT). These results will be used to validate automatic prostate tracking based on soft-tissue contrast.


Assuntos
Marcadores Fiduciais , Imagem Cinética por Ressonância Magnética/métodos , Movimento , Neoplasias da Próstata/cirurgia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Algoritmos , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...