Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Medicine (Baltimore) ; 102(20): e33817, 2023 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-37335725

RESUMO

The diagnosis of cardiac transthyretin amyloidosis can involve early or delayed 99mTc-pyrophosphate planar, single photon emission computed tomography (SPECT), and/or SPECT/CT imaging. We investigated whether image interpretations differed among modalities and time points. In this observational study, data were reviewed for 173 patients with suspected transthyretin amyloidosis who underwent planar and SPECT/CT 1 and 3 hours after radiopharmaceutical injection. Planar heart-to-contralateral lung ratios were calculated. Myocardial-to-rib uptake was independently scored on SPECT and SPECT/CT as follows: 0 (negative), 1 < rib (equivocal), 2 = rib (positive), or 3 > rib (positive), and the image quality was as follows:1 (poor), 2 (adequate), and 3 (good). Three-hour SPECT/CT readings were used as the reference standard against which the other readings were compared. Twenty-five percent of patients were positive (3-hour SPECT/CT score ≥ 2). Compared to 3-hour SPECT/CT readings, there was "fair agreement" (κ = .27 - .33) with SPECT, and "fair agreement" (κ = .23 - .31) with planar imaging at 1 and 3 hours. More patients had abnormal SPECT and SPECT/CT than planar imaging (24-25% vs 16-17%, P < .007). There were more equivocal cases for 1 and 3 hours planar imaging than for 1 and 3 hours SPECT (71-73% vs 23-26%, P < .001) and 1 and 3 hours SPECT/CT (3-5%, P < .001). SPECT/CT image quality was higher at 3 hours than at 1 hour and higher than that on SPECT (P = .001). Three-hour SPECT/CT readings provided the highest number of definitive readings, had the highest image quality, and constituted the preferred protocol for evaluating unselected populations of patients that have a clinical suspicion of possible cardiac amyloidosis.


Assuntos
Neuropatias Amiloides Familiares , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Neuropatias Amiloides Familiares/diagnóstico por imagem , Coração , Cintilografia , Compostos Radiofarmacêuticos
4.
Int J Cardiovasc Imaging ; 39(3): 631-639, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36543909

RESUMO

Coronary flow capacity (CFC) categorizes severity of left ventricular (LV) ischemia by PET myocardial blood flow (MBF). Our objective was to correlate abnormal CFC with other indicators of regional ischemia. Data were examined retrospectively for 231 patients evaluated for known/suspected CAD who underwent rest and regadenoson-stress 82Rb PET/CT. MBF and myocardial flow reserve (MFR) were quantified, from which CFC was categorized as Normal CFC (1), Minimally reduced (2), Mildly reduced (3), Moderately reduced (4), and Severely reduced (5) for the three main arterial territories as well as globally. Relative perfusion summed stress score (SSS) and systolic phase contraction bandwidth (BW) were assessed. Accuracy to detect arteries with CFC ≥ 4 was highest for a Regional Index combining SSS and BW (88 ± 3%). A Global Index formed from stress ejection fraction, SSS and BW was the most accurate means of identifying patients with global CFC ≥ 4 (84 ± 3%). Arteries with abnormal CFC derived from absolute myocardial blood flow measurements are accurately identified by composite parameters combining regionally aberrant relative perfusion patterns and asynchrony.


Assuntos
Doença da Artéria Coronariana , Isquemia Miocárdica , Imagem de Perfusão do Miocárdio , Humanos , Estudos Retrospectivos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Valor Preditivo dos Testes , Circulação Coronária
5.
J Nucl Cardiol ; 30(3): 1235-1245, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36352087

RESUMO

BACKGROUND: We investigated quantitative 99mTc-pyrophosphate (PYP) SPECT/CT reproducibility and accuracy for diagnosing cardiac transthyretin amyloidosis (ATTR), and whether SPECT/CT improved visual and quantitative results compared to SPECT-only. METHODS: Data were reviewed for 318 patients with suspected ATTR who underwent PYP SPECT/CT. Myocardial-to-blood pool count (MBP) ratios were computed and repeated independently > 1 month later. A physician independently scored LV myocardial-to-rib uptake on SPECT/CT as: 0 (negative), 1 < rib (equivocal), 2 = rib (positive) or 3 > rib (positive), and the image quality as: 1 (poor), 2 (adequate), and 3 (good). SPECT-only MBP ratios and visual scores were assessed separately for a subgroup of the first sequential 191 patients. RESULTS: 25% of patients had positive myocardial uptake (myocardial-to-rib uptake score of ≥ 2). SPECT/CT MBP ratios were reproducible (1.35 ± .68 vs 1.33 ± .74, p = .09) and corresponded with visual scores ≥ 2 (ROC AUC = 99 ± 1%) more accurately than SPECT-only MBPs (93 ± 3%, p = .02). SPECT/CT image quality was better than that of SPECT-only (2.7 ± .5 vs 2.1 ± .5, p < .0001) with fewer equivocal results (2.6% vs 22.5%, p < .0001). CONCLUSION: SPECT/CT produces MBP ratios that are reproducible and accurately identify a positive scan, with better image quality and fewer equivocal cases than SPECT-only.


Assuntos
Neuropatias Amiloides Familiares , Cardiomiopatias , Humanos , Difosfatos , Pirofosfato de Tecnécio Tc 99m , Reprodutibilidade dos Testes , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único
6.
J Nucl Cardiol ; 29(5): 2583-2594, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34417670

RESUMO

BACKGROUND: We wished to document the prevalence and quantitative effects of compromised 82Rb PET data acquisitions on myocardial flow reserve (MFR). METHODS AND RESULTS: Data were analyzed retrospectively for 246 rest and regadenoson-stress studies of 123 patients evaluated for known or suspected CAD. An automated injector delivered pre-determined activities of 82Rb. Automated quality assurance algorithms identified technical problems for 7% (9/123) of patients. Stress data exhibited 2 instances of scanner saturation, 1 blood peak detection, 1 blood peak width, 1 gradual patient motion, and 2 abrupt patient motion problems. Rest data showed 1 instance of blood peak width and 2 abrupt patient motion problems. MFR was lower for patients with technical problems flagged by the quality assurance algorithms than those without technical problems (1.5 ± 0.5 versus 2.1 ± 0.7, P = 0.01), even though rest and stress ejection fraction, asynchrony and relative myocardial perfusion measures were similar for these two groups (P > 0.05), suggesting that MFR accuracy was adversely affected by technical errors. CONCLUSION: It is important to verify integrity of 82Rb data to ensure MFR computation quality.


Assuntos
Confiabilidade dos Dados , Reserva Fracionada de Fluxo Miocárdico , Tomografia por Emissão de Pósitrons , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Tomografia por Emissão de Pósitrons/métodos , Estudos Retrospectivos , Radioisótopos de Rubídio
12.
J Nucl Cardiol ; 28(3): 1040-1050, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-32705624

RESUMO

BACKGROUND: Asynchrony has been reported to be a marker of ischemic-induced left ventricular dysfunction, the magnitude of which correlates with extent of epicardial coronary disease. We wished to determine whether normal-appearing arterial territories with mild degrees of asynchrony have lower 82Rb PET absolute myocardial blood flow (MBF) and/or lower myocardial flow reserve (MFR). METHODS AND RESULTS: Data were examined retrospectively for 105 patients evaluated for known/suspected CAD who underwent rest/regadenoson-stress 82Rb PET/CT and quantitative coronary angiography. Rest and stress absolute MBF and MFR were quantified from first-pass 82Rb PET curves. Regional relative myocardial perfusion summed stress score (SSS), summed rest score (SRS), regional phase bandwidth (BW), and regional semi-quantitative asynchrony visual scores of (Asynch) were assessed. We found that in apparently normal arteries (SSS < 4, SRS < 4 and stenosis < 70%), those with abnormally low MFR < 2.0 compared to those with MFR ≥ 2.0 had larger phase BW (186 ± 79° vs 158 ± 67°, P = .02), and more visually apparent Asynch (5.7 ± 4.2 vs 3.9 ± 3.6, P = .02), which was associated with increasing stenosis values (ρ = 0.44, P < .0001). CONCLUSION: A subgroup of coronary territories with normal relative perfusion and normal or non-obstructive coronary disease may have reduced MFR, which is signaled physiologically by a mild degree of left ventricular asynchrony.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/complicações , Circulação Coronária/fisiologia , Feminino , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
13.
Ann Nucl Cardiol ; 6(1): 11-14, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-37123493

RESUMO

The COVID-19 pandemic has altered all aspects of performing medical procedures throughout the world. It is important to stratify patients into categories according to the likelihood that a requested exam will result in a change in acute management. Health care staff should maintain adequate distancing and engage in frequent hand washing, and personnel who are patient-facing should put on PPE at all times. All patient-touching apparatus should be disinfected between patients according to the Infection Control protocols of the institutions. Most labs have chosen to have patients wear surgical masks to afford some level of protection for them. Efforts should be implemented to enable remote reading and remote reporting of study results. The guidelines presented in this paper are based on the currently available information regarding SARS-CoV-2 (COVID-19) viral infections, but it is essential that all laboratories comply with evolving recommendations of their institutions and public health authorities.

14.
J Nucl Cardiol ; 27(2): 575-588, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-29946825

RESUMO

OBJECTIVE: 82Rb PET/CT rest/regadenoson-stress data enable quantification of left ventricular rest and stress function, perfusion, and asynchrony. Our study was conducted to determine which parameters best identify patients with multi-vessel disease (MVD) and individual stenosed arteries. METHODS: PET/CT data were reviewed retrospectively for 105 patients referred for evaluation of CAD, who also underwent angiography. % arterial stenosis was determined quantitatively at a core laboratory. Severe stenosis was defined as ≥ 70%, and MVD as 2 or more stenosed arteries. Segmental MBF was calculated from first-pass data for arterial territories. Regional rest and stress systolic and diastolic asynchrony (Asynch) scores were determined from visual examination of phase polar maps. RESULTS: 65 vessels had stenoses ≥ 70%. 15 patients had MVD. ROC area under curve (ROC AUC) for identifying patients with MVD was 83% for Asynch and 73% for MFR. ROC AUC for identifying individual arterial territories with stenoses ≥ 70% was 81% and 72% for Asynch and MFR. CONCLUSION: 82Rb PET/CT accurately identified patients with MVD and individual stenosed territories, with regional asynchrony measurements contributing significantly to identify patients with CAD.


Assuntos
Angiografia/métodos , Constrição Patológica/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Coração/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Miocárdio/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Purinas/química , Pirazóis/química , Radioisótopos de Rubídio , Idoso , Algoritmos , Área Sob a Curva , Angiografia Coronária , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária , Feminino , Ventrículos do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
18.
J Nucl Cardiol ; 24(1): 43-52, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-26403144

RESUMO

OBJECTIVE: 82Rb PET protocols enable determination of left ventricular asynchrony (LVAS) at rest and stress, along with myocardial blood flow (MBF). We hypothesized that in patients with resting LVAS, MBF differs between those with stress-induced LVAS improvement and those with stress-induced LVAS deterioration. METHODS: We retrospectively analyzed 82Rb rest/regadenoson stress PET studies of 195 patients evaluated for known or suspected coronary artery disease. MBF was computed from first-pass data; function and relative perfusion were computed from myocardial equilibrium data. LVAS was defined as phase contraction bandwidth (BW) above 82Rb gender-specific normal limits, with changes defined as BW moving into or out of normal ranges. RESULTS: Among the 195 patients, 64 had LVAS at rest, of whom 13 reverted to normal and 51 continued to have LVAS with stress. Patients who did not improve had lower stress MBF (1.04 ± 0.69 vs 1.58 ± 0.67, p = .02) and coronary flow reserve (1.94 ± 1.16 vs 3.04 ± 1.22, p = .01) than those who did improve. ROC analysis indicated that the parameter most strongly associated with improvement in asynchrony for patients with resting LVAS was reduction in MBF heterogeneity (ROC area (accuracy) = 84%, sensitivity = 92%, and specificity = 67%). CONCLUSION: LVAS is highly correlated with MBF and CVR, with stress-induced improvement in synchronicity most strongly associated with improved MBF homogeneity.


Assuntos
Velocidade do Fluxo Sanguíneo , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária , Contração Miocárdica , Imagem de Perfusão do Miocárdio/métodos , Disfunção Ventricular Esquerda/fisiopatologia , Idoso , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/etiologia , Teste de Esforço , Feminino , Humanos , Masculino , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Rubídio , Sensibilidade e Especificidade , Volume Sistólico , Resistência Vascular , Disfunção Ventricular Esquerda/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...