Clin Chem Lab Med ; 60(10): 1617-1626, 2022 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-35790193

RESUMO

OBJECTIVES: Rheumatoid factor (RF) is a well-established marker for the diagnosis and classification of rheumatoid arthritis (RA). Most studies evaluated IgM RF or isotype-nonspecific total RF assays. We evaluated the added value of IgA RF in this context. METHODS: An international sample cohort consisting of samples from 398 RA patients and 1073 controls was tested for IgA RF with 3 commercial assays. For all RA patients and 100 controls essential clinical and serological data for ACR/EULAR classification were available. RESULTS: The sensitivity of IgA RF for diagnosing RA was lower than the sensitivity of IgM RF. Differences in numerical values between IgA RF assays were observed. With all assays, the highest IgA RF values were found in patients with primary Sjögren's syndrome. Double positivity for IgM RF and IgA RF had a higher specificity for RA than either IgM RF or IgA RF. The sensitivity of double positivity was lower than the sensitivity of either IgA RF or IgM RF. Single positivity for IgA RF was at least as prevalent in controls than in RA patients. Adding IgA RF to IgM RF and anti-citrullinated protein antibodies (ACPA) did not affect RA classification. However, combined positivity for IgA RF, IgM RF and IgG ACPA had a higher specificity and lower sensitivity for RA classification than positivity for either of the antibodies. CONCLUSIONS: IgA RF showed a lower sensitivity than IgM RF. Combining IgA RF with IgM RF and ACPA did not improve sensitivity of RA classification. Combined positivity (IgA-RF/IgM-RF/ACPA) increased specificity.


Assuntos
Artrite Reumatoide , Imunoglobulina A , Imunoglobulina M , Fator Reumatoide , Artrite Reumatoide/diagnóstico , Humanos , Imunoglobulina A/química , Imunoglobulina M/química , Peptídeos Cíclicos , Fator Reumatoide/metabolismo , Sensibilidade e Especificidade
3.
Ann Rheum Dis ; 2022 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-35697487

RESUMO

INTRODUCTION: Commercial assays measuring antibodies to citrullinated protein/peptide (ACPA) show poor quantitative agreement. The diagnostic industry has never adopted the International Union of Immunological Societies-Centers for Disease Control and Prevention (IUIS-CDC) ACPA reference standard. Recently, the National Institute for Biological Standards and Control (NIBSC) prepared a new candidate ACPA standard (18/204). We evaluated both reference materials using different commercially available ACPA assays. MATERIALS AND METHODS: This is an international study in which the NIBSC candidate ACPA standard and the IUIS-CDC ACPA reference material were analysed together with 398 diagnostic samples from individuals with rheumatoid arthritis (RA) and in 1073 individuals who did not have RA using nine commercial ACPA assays. RESULTS: For both reference materials and samples from individuals with RA and individuals who did not have RA, there were large differences in quantitative ACPA results between assays. For most assays, values for the IUIS-CDC standard were lower than values for NIBSC 18/204 and the IUIS-CDC/NIBSC ratio was comparable for several, but not all assays. When NIBSC 18/204 was used as a calibrator, an improvement in alignment of ACPA results across several of the evaluated assays was obtained. Moreover, NIBSC 18/204 could align clinical interpretation for some but not all assays. CONCLUSION: Adoption of an international standard for ACPA determination is highly desirable. The candidate NIBSC 18/204 standard improved the standardisation and alignment of most ACPA assays and might therefore be recommended to be used as reference in commercial assays.

4.
RMD Open ; 8(1)2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35321875

RESUMO

BACKGROUND: Rheumatoid factor (RF) and anti-citrullinated protein/peptide antibodies (ACPA) are important biomarkers for diagnosis of rheumatoid arthritis (RA). However, there is poor harmonisation of RF and ACPA assays. The aim of this study was to refine RF and ACPA interpretation across commercial assays. MATERIALS AND METHODS: Six total RF isotype-non-specific assays, 3 RF IgM isotype-specific assays and 9 ACPA immunoglobulin G assays of 13 different companies were evaluated using 398 diagnostic samples from patients with RA and 1073 disease controls. RESULTS: Using cut-offs proposed by the manufacturer, there was a large variability in diagnostic sensitivity and specificity between assays. Thresholds of antibody levels were determined based on predefined specificities and used to define test result intervals. Test result interval-specific likelihood ratios (LRs) were concordant across the different RF and ACPA assays. For all assays, the LR for RA increased with increasing antibody level. Higher LRs were found for ACPA than for RF. ACPA levels associated with LRs >80 were found in a substantial fraction (>22%) of patients with RA. CONCLUSION: Defining thresholds for antibody levels and assigning test result interval-specific LRs allows alignment of clinical interpretation for all RF and ACPA assays.


Assuntos
Artrite Reumatoide , Fator Reumatoide , Anticorpos Antiproteína Citrulinada , Artrite Reumatoide/diagnóstico , Humanos , Peptídeos , Sensibilidade e Especificidade
6.
J Immunol Methods ; 493: 113043, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33773989

RESUMO

OBJECTIVE: Analytical validation of newly released SARS-CoV-2 antibody assays in the clinical laboratory is crucial to ensure sufficient performance in respect to its intended use. We aimed to assess analytical and diagnostic performance of 8 (semi-)quantitative assays detecting anti-nucleocapsid IgG (Euroimmun, Id-Vet) or total Ig (Roche), anti-spike protein IgG (Euroimmun, Theradiag, DiaSorin, Thermo Fisher) or both (Theradiag) and 2 rapid lateral flow assays (LFA) (AAZ-LMB and Theradiag). METHODS: Specificity was evaluated using a cross-reactivity panel of 85 pre-pandemic serum samples. Sensitivity was determined at both the manufacturer's and a 95% specificity cut-off level, using 81 serum samples of patients with a positive rRT-PCR. Sensitivity was determined in function of time post symptoms onset. RESULTS: Specificity for all assays ranged from 92.9% to 100% (Roche and Thermo Fisher) with the exception of the Theradiag IgM LFA (82.4%). Sensitivity in asymptomatic patients ranged between 41.7% and 58.3%. Sensitivity on samples taken <10 days since symptom onset was low (23.3%-66.7%) and increased on samples taken between 10 and 20 days and > 20 days since symptom onset (80%-96% and 92.9%-100%, respectively). From 20 days after symptom onset, the Roche, Id-vet and Thermo Fisher assays all met the sensitivity (>95%) and specificity (>97%) targets determined by the WHO. Antibody signal response was significantly higher in the critically ill patient group. CONCLUSION: Antibody detection can complement rRT-PCR for the diagnosis of COVID-19, especially in the later stage, or in asymptomatic patients for epidemiological purposes. Addition of IgM in LFAs did not improve sensitivity.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19 , COVID-19/diagnóstico , Imunidade Humoral , Imunoglobulina G/sangue , Kit de Reagentes para Diagnóstico , SARS-CoV-2/imunologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , COVID-19/sangue , COVID-19/imunologia , COVID-19/virologia , Feminino , Interações Hospedeiro-Patógeno , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
7.
Clin Chim Acta ; 517: 149-155, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33689693

RESUMO

BACKGROUND: Calprotectin (CLP) is a promising biomarker for the evaluation of neutrophil-related inflammation. Our aim was to establish reference values for circulating CLP in different sample types and to study the effect of pre-analytical variables. METHODS: Reference values were determined in 100 healthy individuals. Pre-analytical variables were evaluated in 10 healthy controls and four rheumatoid arthritis patients with active disease and covered sample type (serum with/without gel separator, heparin, EDTA and citrate plasma), pre-centrifugation time (<2 h, 6 h, 24 h), storage condition (2-8 °C, 18-25 °C, 30 °C) and storage time (24 h, 72 h, 7 days). CLP measurements were performed with the EliA™Calprotectin 2 assay on Phadia™200 (Thermo Fisher Scientific). RESULTS: In healthy controls, baseline CLP concentrations in serum were more than double the concentration in EDTA and citrate plasma (0.909 µg/mL versus 0.259 µg/mL and 0.261 µg/mL respectively). Heparin, EDTA and citrate stabilized CLP concentrations for up to 6 h before centrifugation, whereas significant increases in CLP levels were observed when serum was left untreated during that time period. CONCLUSION: Clinical studies on circulating CLP need to apply sample type-specific reference values and decision limits. To obtain reproducible CLP results in serum, more stringent pre-analytical sample handling instructions are needed.


Assuntos
Complexo Antígeno L1 Leucocitário , Neutrófilos , Biomarcadores , Coleta de Amostras Sanguíneas , Humanos , Inflamação/diagnóstico , Valores de Referência
8.
Clin Chem Lab Med ; 59(7): 1247-1255, 2021 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-33594844

RESUMO

OBJECTIVES: Currently available computer-aided diagnosis (CAD) systems for the detection of anti-nuclear antibodies (ANA) by indirect immunofluorescence (IIF) assay enable a standardized measurement of system-specific fluorescent intensity (FI) measures. We aimed to evaluate an internal quality control (iQC) program that controls the total ANA IIF process in routine practice. METHODS: In addition to the kit iQC materials, supplemental quality indicators were integrated in a total quality assurance (QA) program: patient-derived iQC's samples (negative, 1/160 fine speckled and 1/160 homogeneous), median sample FI per run and percentage of ANA IIF positive samples per run. Analytical rejection criteria were based on the imprecision of the positivity index (PI) measure of the Zenit PRO system (Menarini). Clinical rejection criteria were based on changes in FI that correspond to a change in ANA IIF titer of ≥2. To evaluate the QA program, different artificial errors were introduced during the ANA IIF process. After every run, quality indicators were evaluated and compared to the pre-set target values. RESULTS: Rescanning the ANA IIF slides five times, using an old conjugate and a needle obstruction resulted in analytically and even clinically relevant errors in ANA IIF results. All errors were correctly detected by the different defined quality indicators. Traditional Westgard rules, including analytically (and clinically) defined rejection limits were useful in monitoring quality indicators. CONCLUSIONS: The integration of a total process iQC program in CAD systems, based on the specific FI measurands and performance criteria of the system, adds value to QA.


Assuntos
Anticorpos Antinucleares , Autoimunidade , Testes Diagnósticos de Rotina , Técnica Indireta de Fluorescência para Anticorpo , Humanos , Controle de Qualidade
9.
Clin Chem Lab Med ; 58(1): 40-49, 2019 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-31665107

RESUMO

Background There is a need for additional biomarkers to assist in the diagnosis and prognosis of rheumatoid arthritis (RA). The aim of our study was to evaluate the (pre-analytical, analytical and clinical) performance of serum calprotectin as a marker of inflammation in RA. Methods The study population included 463 rheumatologic patients (including 111 RA patients and 352 controls) who for the first time consulted a rheumatologist, 20 healthy controls and 27 patients with an infectious disease. Calprotectin was measured (using four different assays) in serum or in serum and EDTA plasma (healthy controls and infectious disease group). For rheumatologic patients, results for C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), rheumatoid factor (RF) and anti-cyclic citrullinated peptide antibody (ACPA) were available. Results Results for blood calprotectin were assay- and matrix-dependent, with higher values found in serum than in plasma. Serum calprotectin was higher in RA patients than in rheumatologic diseased controls and in healthy controls. Serum calprotectin was lower in RA patients than in patients with an infectious disease. Serum calprotectin was associated with disease activity (DAS score). The area under the curve (AUC) to discriminate RA from controls was 0.756 for CRP, 0.714 for ESR and 0.726-0.783 for calprotectin. Conclusions Our data document that calprotectin measurement is assay- and matrix-dependent. Serum calprotectin is associated with disease activity. Additional (prospective) studies are warranted to further evaluate the prognostic and diagnostic value of blood calprotectin measurements.


Assuntos
Artrite Reumatoide/sangue , Análise Química do Sangue/métodos , Complexo Antígeno L1 Leucocitário/sangue , Adulto , Artefatos , Biomarcadores/sangue , Estudos de Casos e Controles , Estudos de Coortes , Feminino , Humanos , Masculino
10.
Clin Chem Lab Med ; 57(7): 990-998, 2019 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-30838836

RESUMO

Background The introduction of automated anti-nuclear antibody (ANA) indirect immunofluorescence (IIF) analysis may allow for more harmonized ANA IIF reporting, provided that a thorough quality assurance program controls this process. The aim of this study was to evaluate various quality indicators used for ANA IIF analysis with the final goal of optimizing the iQC program. Methods In an experimental setup, we introduced artificial errors, mimicking plausible problems during routine practice on a QUANTA-Lyser-NOVA View® system (Inova Diagnostics, San Diego, CA, USA). Predetermined quality indicators were evaluated against predefined acceptance criteria. In addition, we retrospectively investigated the applicability of the selected quality indicators in the daily routine practice during three pre-defined periods. Results Both the experimental as the retrospective study revealed that pre-analytical, analytical and post-analytical errors were not highlighted by company internal quality control (iQC) materials. The use of patient derived iQC samples, median fluorescence intensity results per run and the percentage of positive ANA IIF results as additional quality indicators ensured a more adequate ANA IIF quality assurance. Furthermore, negative and moderate positive sample iQC materials merit clinical validation, as titer changes of >1 correspond to clinically important shifts. Traditional Westgard rules, including a clinically defined stop limit, revealed to be useful in monitoring of the supplemental quality indicators. Conclusions A thorough ANA IIF quality assurance for daily routine practice necessitates the addition of supplemental quality indicators in combination with well-defined acceptance criteria.


Assuntos
Anticorpos Antinucleares/análise , Técnica Indireta de Fluorescência para Anticorpo/métodos , Automação , Erros de Diagnóstico , Técnica Indireta de Fluorescência para Anticorpo/normas , Humanos , Controle de Qualidade , Estudos Retrospectivos
14.
Ann Rheum Dis ; 77(5): 667-677, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29363510

RESUMO

OBJECTIVES: Rheumatoid factor (RF) and anti-cyclic citrullinated protein/peptide antibodies (ACPA) are integrated in the 2010 American College of Rheumatology/European League Against Rheumatism (ACR/EULAR) classification criteria for rheumatoid arthritis (RA). The objectives of this study were to evaluate the technical and diagnostic performance of different RF and ACPA assays and to evaluate whether differences in performance impact RA classification. METHODS: Samples from 594 consecutive patients who for the first time consulted a rheumatologist (44 of whom were diagnosed with RA) and 26 extra newly diagnosed patients with RA were analysed with six different RF assays (Menarini, Thermo Fisher, Inova, Roche, Abbott, Euroimmun) and seven different ACPA assays (Menarini, Thermo Fisher, Inova, Roche, Abbott, Euro Diagnostica, Euroimmun). RESULTS: We found differences in analytical performance between assays. There was poor numerical agreement between the different RF and ACPA assays. For all assays, the likelihood ratio for RA increased with increasing antibody levels. The areas under the curve of receiver operating characteristic analysis of the RF (range 0.676-0.709) and ACPA assays (range 0.672-0.769) only differed between some ACPA assays. Nevertheless, using the cut-off proposed by the manufacturer, there was a large variation in sensitivity and specificity between assays (mainly for RF). Consequently, depending on the assay used, a subgroup of patients (13% for RF, 1% for ACPA and 9% for RF/ACPA) might or might not be classified as RA according to the 2010 ACR/EULAR criteria. CONCLUSION: Due to poor harmonisation of RF and ACPA assays and of test result interpretation, RA classification according to 2010 ACR/EULAR criteria may vary when different assays are used.


Assuntos
Anticorpos Antiproteína Citrulinada/sangue , Artrite Reumatoide/diagnóstico , Imunoensaio/métodos , Fator Reumatoide/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Feminino , Humanos , Funções Verossimilhança , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
J Immunol Res ; 2017: 6038137, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28321418

RESUMO

Background. Our study aimed to investigate whether the introduction of automated anti-nuclear antibody (ANA) indirect immunofluorescence (IIF) analysis decreases the interlaboratory variability of ANA titer results. Method. Three serum samples were sent to 10 laboratories using the QUANTA-Lyser® in combination with the NOVA View®. Each laboratory performed the ANA IIF analysis 10x in 1 run and 1x in 10 different runs and determined the endpoint titer by dilution. One of the three samples had been sent in 2012, before the era of ANA IIF automation, by the Belgian National External Quality Assessment (EQA) Scheme. Harmonization was evaluated in terms of variability in fluorescence intensity (LIU) and ANA IIF titer. Results. The evaluation of the intra- and interrun LIU variability revealed a larger variability for 2 laboratories, due to preanalytical and analytical problems. Reanalysis of the EQA sample resulted in a lower titer variability. Diluted endpoint titers were similar to the estimated single well titer and the overall median titer as reported by the EQA in 2012. Conclusion. The introduction of automated microscopic analysis allows more harmonized ANA IIF reporting, provided that this totally automated process is controlled by a thorough quality assurance program, covering the total ANA IIF process.


Assuntos
Anticorpos Antinucleares/sangue , Automação Laboratorial , Doença de Crohn/diagnóstico , Técnica Indireta de Fluorescência para Anticorpo , Síndrome de Sjogren/diagnóstico , Bélgica , Doença de Crohn/epidemiologia , Técnica Indireta de Fluorescência para Anticorpo/instrumentação , Técnica Indireta de Fluorescência para Anticorpo/métodos , Humanos , Microscopia de Fluorescência , Variações Dependentes do Observador , Garantia da Qualidade dos Cuidados de Saúde , Reprodutibilidade dos Testes , Síndrome de Sjogren/epidemiologia , Avaliação da Tecnologia Biomédica
17.
Clin Chem Lab Med ; 55(10): 1564-1573, 2017 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-28222018

RESUMO

BACKGROUND: We evaluated the analytical performance of six different faecal calprotectin immunoassays together with their diagnostic accuracy in the discrimination between functional and organic bowel disorders. METHODS: The faecal samples were obtained from inflammatory bowel disease patients (n=27) at the time of diagnosis [Crohn's disease (n=15), colitis ulcerosa (n=12)], gastroenterologic disease control patients (n=52) and rheumatologic disease control patients (n=26). All individuals included in the study underwent a concurrent ileocolonoscopy. Analytical performance (imprecision, accuracy, carry-over, correlation and agreement) and diagnostic accuracy (sensitivity, specificity, likelihood ratios) of the different assays were evaluated. RESULTS: All methods demonstrated good analytical performance, but within-run and total imprecision varied depending on the assay methodology used. Using Passing Bablok and Bland-Altman analyses, low quantitative agreement was observed between the assays. All assays showed excellent diagnostic accuracy, with areas under the receiver operating characteristic curves (ROC) ranging from 0.974 to 0.998. The AUCs were not significantly different between assays (p>0.05). Diagnostic sensitivity at the cut-off at a fixed specificity of 75% ranged from 95.2% to 100%. Introduction of multiple result intervals increased the clinical interpretation of all the assays. CONCLUSIONS: Analytical and diagnostic performance of the evaluated faecal calprotectin assays is good, but numerical values differ substantially between the assays necessitating the use of different clinical cut-offs. Introduction of multiple result intervals aids in clinical decision-making.


Assuntos
Fezes/química , Imunoensaio , Doenças Inflamatórias Intestinais/diagnóstico , Complexo Antígeno L1 Leucocitário/análise , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Colonoscopia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , Adulto Jovem
18.
Biotechnol Biofuels ; 8: 32, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25759747

RESUMO

BACKGROUND: During the final phases of bioethanol fermentation, yeast cells face high ethanol concentrations. This stress results in slower or arrested fermentations and limits ethanol production. Novel Saccharomyces cerevisiae strains with superior ethanol tolerance may therefore allow increased yield and efficiency. Genome shuffling has emerged as a powerful approach to rapidly enhance complex traits including ethanol tolerance, yet previous efforts have mostly relied on a mutagenized pool of a single strain, which can potentially limit the effectiveness. Here, we explore novel robot-assisted strategies that allow to shuffle the genomes of multiple parental yeasts on an unprecedented scale. RESULTS: Screening of 318 different yeasts for ethanol accumulation, sporulation efficiency, and genetic relatedness yielded eight heterothallic strains that served as parents for genome shuffling. In a first approach, the parental strains were subjected to multiple consecutive rounds of random genome shuffling with different selection methods, yielding several hybrids that showed increased ethanol tolerance. Interestingly, on average, hybrids from the first generation (F1) showed higher ethanol production than hybrids from the third generation (F3). In a second approach, we applied several successive rounds of robot-assisted targeted genome shuffling, yielding more than 3,000 targeted crosses. Hybrids selected for ethanol tolerance showed increased ethanol tolerance and production as compared to unselected hybrids, and F1 hybrids were on average superior to F3 hybrids. In total, 135 individual F1 and F3 hybrids were tested in small-scale very high gravity fermentations. Eight hybrids demonstrated superior fermentation performance over the commercial biofuel strain Ethanol Red, showing a 2 to 7% increase in maximal ethanol accumulation. In an 8-l pilot-scale test, the best-performing hybrid fermented medium containing 32% (w/v) glucose to dryness, yielding 18.7% (v/v) ethanol with a productivity of 0.90 g ethanol/l/h and a yield of 0.45 g ethanol/g glucose. CONCLUSIONS: We report the use of several different large-scale genome shuffling strategies to obtain novel hybrids with increased ethanol tolerance and fermentation capacity. Several of the novel hybrids show best-parent heterosis and outperform the commonly used bioethanol strain Ethanol Red, making them interesting candidate strains for industrial production.