Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Plant Sci ; 14: 1265458, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37854113

RESUMO

Gravity directs the polarization of Ceratopteris fern spores. This process begins with the uptake of calcium through channels at the bottom of the spore, a step necessary for the gravity response. Data showing that extracellular ATP (eATP) regulates calcium channels led to the hypothesis that extracellular nucleotides could play a role in the gravity-directed polarization of Ceratopteris spores. In animal and plant cells ATP can be released from mechanosensitive channels. This report tests the hypothesis that the polarized release of ATP from spores could be activated by gravity, preferentially along the bottom of the spore, leading to an asymmetrical accumulation of eATP. In order to carry out this test, an ATP biosensor was used to measure the [eATP] at the bottom and top of germinating spores during gravity-directed polarization. The [eATP] along the bottom of the spore averaged 7-fold higher than the concentration at the top. All treatments that disrupted eATP signaling resulted in a statistically significant decrease in the gravity response. In order to investigate the source of ATP release, spores were treated with Brefeldin A (BFA) and gadolinium trichloride (GdCl3). These treatments resulted in a significant decrease in gravity-directed polarization. An ATP biosensor was also used to measure ATP release after treatment with both BFA and GdCl3. Both of these treatments caused a significant decrease in [ATP] measured around spores. These results support the hypothesis that ATP could be released from mechanosensitive channels and secretory vesicles during the gravity-directed polarization of Ceratopteris spores.

2.
RSC Adv ; 13(25): 17244-17252, 2023 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-37304770

RESUMO

Iron (Fe) is a required micronutrient in plants for the production of chlorophyll and transport of oxygen. A commonly used surrogate for measuring nutrient levels is the measurement of electrical conductivity or total dissolved solids, but this technique is not selective towards any particular dissolved ion. In this study, using a conventional microwave, fluorescent carbon dots (CDs) are produced from glucose and a household cleaning product and applied towards monitoring dissolved ferric iron levels in hydroponic systems through fluorescent quenching. The produced particles have an average size of 3.19 ± 0.76 nm with a relatively high degree of oxygen surface groups. When using an excitation of 405 nm, a broad emission peak is centered at approximately 500 nm. A limit-of-detection of 0.196 ± 0.067 ppm (3.51 ± 1.21 µM) with minimal interference from common heavy metal quenchers and ions found in hydroponic systems was determined. Butterhead lettuce was grown while discretely monitoring iron levels via the CDs for three separate weeks of growth. The CDs displayed a non-significant difference (p > 0.05) in performance when compared to a standard method. These results along with a simple and relatively low-cost production method make the CDs in this study a promising tool for monitoring iron levels in hydroponic systems.

3.
Biosensors (Basel) ; 12(12)2022 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-36551049

RESUMO

Biosensors often combine biological recognition elements with nanomaterials of varying compositions and dimensions to facilitate or enhance the operating mechanism of the device. While incorporating nanomaterials is beneficial to developing high-performance biosensors, at the stages of scale-up and disposal, it may lead to the unmanaged release of toxic nanomaterials. Here we attempt to foster connections between the domains of biosensors development and human and environmental toxicology to encourage a holistic approach to the development and scale-up of biosensors. We begin by exploring the toxicity of nanomaterials commonly used in biosensor design. From our analysis, we introduce five factors with a role in nanotoxicity that should be considered at the biosensor development stages to better manage toxicity. Finally, we contextualize the discussion by presenting the relevant stages and routes of exposure in the biosensor life cycle. Our review found little consensus on how the factors presented govern nanomaterial toxicity, especially in composite and alloyed nanomaterials. To bridge the current gap in understanding and mitigate the risks of uncontrolled nanomaterial release, we advocate for greater collaboration through a precautionary One Health approach to future development and a movement towards a circular approach to biosensor use and disposal.


Assuntos
Técnicas Biossensoriais , Nanoestruturas , Humanos , Técnicas Biossensoriais/métodos
4.
Biosensors (Basel) ; 12(2)2022 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-35200361

RESUMO

Rapid detection of proteins is critical in a vast array of diagnostic or monitoring applications [...].


Assuntos
Proteínas/análise , Humanos , Modelos Estatísticos , Proteínas/química , Sensibilidade e Especificidade
5.
Environ Eng Sci ; 38(5): 340-354, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34079207

RESUMO

El Tiple is one of many marginalized Afrodescendant communities confined within a green desert located in the southwest region of Colombia. This green desert is most widely known as the second-largest sugarcane monoculture field in the Americas. Herein, we describe a transdisciplinary and participatory effort to understand agroindustrial expansion in the region through the lens of the El Tiple community. Using qualitative and quantitative methodologies, we characterized the socioenvironmental context of El Tiple in terms of ethnography, autoethnography, social cartography, and ethnobotany. We implemented a participatory approach to codevelop a technology-assisted strategy for strengthening the community's small-scale farming activities. Our contextual analysis results show systemic food dispossession, which arises from several factors, including dramatic land transformation, rapid depletion and contamination of natural assets, and biodiversity loss. All these factors are associated with the presence of bordering sugarcane plantations. In collaboration with community members, we designed, constructed, and analyzed a greenhouse hydroponic cultivation system as an actionable means to gradually restore local production of food and medicinal plants for the community. Our transdisciplinary and participatory approach demonstrates how academics can partner with vulnerable communities in the coproduction of knowledge and solutions to pressing social needs.

6.
Front Chem ; 8: 782, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33110911

RESUMO

For the past few decades, a plethora of nanoparticles have been produced through various methods and utilized to advance technologies for environmental applications, including water treatment, detection of persistent pollutants, and soil/water remediation, amongst many others. The field of materials science and engineering is increasingly interested in increasing the sustainability of the processes involved in the production of nanoparticles, which motivates the exploration of alternative inputs for nanoparticle production as well as the implementation of green synthesis techniques. Herein, we start by overviewing the general aspects of nanoparticle synthesis from industrial, electric/electronic, and plastic waste. We expand on critical aspects of waste identification as a viable input for the treatment and recovery of metal- and carbon-based nanoparticles. We follow-up by discussing different governing mechanisms involved in the production of nanoparticles, and point to potential inferences throughout the synthesis processes. Next, we provide some examples of waste-derived nanoparticles utilized in a proof-of-concept demonstration of technologies for applications in water quality and safety. We conclude by discussing current challenges from the toxicological and life-cycle perspectives that must be taken into consideration before scale-up manufacturing and implementation of waste-derived nanoparticles.

7.
Diagnostics (Basel) ; 10(1)2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-31906350

RESUMO

In this manuscript, we discuss relevant socioeconomic factors for developing and implementing sensor analytic point solutions (SNAPS) as point-of-care tools to serve impoverished communities. The distinct economic, environmental, cultural, and ethical paradigms that affect economically disadvantaged users add complexity to the process of technology development and deployment beyond the science and engineering issues. We begin by contextualizing the environmental burden of disease in select low-income regions around the world, including environmental hazards at work, home, and the broader community environment, where SNAPS may be helpful in the prevention and mitigation of human exposure to harmful biological vectors and chemical agents. We offer examples of SNAPS designed for economically disadvantaged users, specifically for supporting decision-making in cases of tuberculosis (TB) infection and mercury exposure. We follow-up by discussing the economic challenges that are involved in the phased implementation of diagnostic tools in low-income markets and describe a micropayment-based systems-as-a-service approach (pay-a-penny-per-use-PAPPU), which may be catalytic for the adoption of low-end, low-margin, low-research, and the development SNAPS. Finally, we provide some insights into the social and ethical considerations for the assimilation of SNAPS to improve health outcomes in marginalized communities.

8.
Biosensors (Basel) ; 8(2)2018 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-29695046

RESUMO

In foods, high levels of biogenic amines (BA) are the result of microbial metabolism that could be affected by temperatures and storage conditions. Thus, the level of BA is commonly used as an indicator of food safety and quality. This manuscript outlines the development of laser scribed graphene electrodes, with locally sourced materials, for reagent-free food safety biosensing. To fabricate the biosensors, the graphene surface was functionalized with copper microparticles and diamine oxidase, purchased from a local supermarket; and then compared to biosensors fabricated with analytical grade materials. The amperometric biosensor exhibits good electrochemical performance, with an average histamine sensitivity of 23.3 µA/mM, a lower detection limit of 11.6 µM, and a response time of 7.3 s, showing similar performance to biosensors constructed from analytical grade materials. We demonstrated the application of the biosensor by testing total BA concentration in fish paste samples subjected to fermentation with lactic acid bacteria. Biogenic amines concentrations prior to lactic acid fermentation were below the detection limit of the biosensor, while concentration after fermentation was 19.24 ± 8.21 mg histamine/kg, confirming that the sensor was selective in a complex food matrix. The low-cost, rapid, and accurate device is a promising tool for biogenic amine estimation in food samples, particularly in situations where standard laboratory techniques are unavailable, or are cost prohibitive. This biosensor can be used for screening food samples, potentially limiting food waste, while reducing chances of foodborne outbreaks.


Assuntos
Amina Oxidase (contendo Cobre)/metabolismo , Aminas Biogênicas/metabolismo , Técnicas Biossensoriais/métodos , Análise de Alimentos/métodos , Grafite/metabolismo , Humanos
9.
Compr Rev Food Sci Food Saf ; 16(6): 1188-1205, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33371585

RESUMO

The presence of unsafe levels of microorganisms in food constitutes a growing economic and public health problem that necessitates new technology for their rapid detection along the food continuum from production to consumption. While traditional techniques are reliable, there is a need for more sensitive, selective, rapid, and cost-effective approaches for food safety evaluation. Methods such as microbiological counts are sufficiently accurate and inexpensive, and are capable of determining presence and viability for most pathogens. However, these techniques are time consuming, involve destructive sampling, and require trained personnel and biosafety-certified facilities for analysis. Molecular techniques such as the polymerase chain reaction have greatly improved analytical capability over the last decade, achieving shorter analysis time with quantitative data and strain specificity, and in some cases the ability to discriminate cell viability. The emerging field of nanosensors/biosensors has demonstrated a variety of devices that hold promise to bridge the gap between traditional plate counting and molecular techniques. Many nanosensors/biosensors are rapid, portable, accurate devices that can be used as an additional screening tool for identifying unsafe levels of microorganisms in food products with no need for pre-enrichment. In this review, we provide a brief overview of available biorecognition-transduction techniques for detecting bacteria in food. We then discuss the advantages and disadvantages of each technique, and describe some recent biosensor or nanosensor technologies that are under development. We conclude by summarizing the opportunities and challenges in the field of pathogen monitoring in food systems and we focus the discussion on the strengths/weaknesses of the most popular biorecognition agents and transducer nanomaterials for biosensing.

10.
Biosens Bioelectron ; 74: 37-44, 2015 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-26094038

RESUMO

The objective of this study was to develop a self-referencing electrochemical biosensor for the direct measurement of ATP flux into the extracellular matrix by living cells/organisms. The working mechanism of the developed biosensor is based on the activity of glycerol kinase and glycerol-3-phosphate oxidase. A stratified bi-enzyme nanocomposite was created using a protein-templated silica sol gel encapsulation technique on top of graphene-modified platinum electrodes. The biosensor exhibited excellent electrochemical performance with a sensitivity of 2.4±1.8 nA/µM, a response time of 20±13 s and a lower detection limit of 1.3±0.7 nM. The self-referencing biosensor was used to measure exogenous ATP efflux by (i) germinating Ceratopteris spores and (ii) growing Zea mays L. roots. This manuscript demonstrates the first development of a non-invasive ATP micro-biosensor for the direct measurement of eATP transport in living tissues. Before this work, assays of eATP have not been able to record the temporally transient movement of ATP at physiological levels (nM and sub-nM). The method demonstrated here accurately measured [eATP] flux in the immediate vicinity of plant cells. Although these proof of concept experiments focus on plant tissues, the technique developed herein is applicable to any living tissue, where nanomolar concentrations of ATP play a critical role in signaling and development. This tool will be invaluable for conducting hypothesis-driven life science research aimed at understanding the role of ATP in the extracellular environment.


Assuntos
Trifosfato de Adenosina/metabolismo , Técnicas Biossensoriais/métodos , Traqueófitas/fisiologia , Zea mays/fisiologia , Trifosfato de Adenosina/análise , Transporte Biológico , Técnicas Biossensoriais/instrumentação , Enzimas Imobilizadas/metabolismo , Desenho de Equipamento , Glicerol Quinase/metabolismo , Glicerolfosfato Desidrogenase/metabolismo , Modelos Moleculares , Raízes de Plantas/fisiologia
11.
AMB Express ; 5: 28, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26020015

RESUMO

Protected by extracellular polymers, microbes within biofilms are significantly more resistant to disinfectants. Current research has been instrumental in identifying nitric oxide donors and hydrogels as potential disinfectant additives. Nitric oxide (NO) donors are considered a very promising molecule as biofilm dispersal agents and hydrogels have recently attracted a lot of interest due to their biocompatible properties and ability to form stable thin films. When the NO donor MAHMA NONOate was dissolved in phosphate saline buffer, it was able to reduce the biomass of well-established biofilms up to 15% for at least 24 h of contact time. Encapsulation of MAHMA NONOate and molsidomine within a hydrogel composed of cellulose nanocrystals (CNC) has shown a synergistic effect in dispersing well-established biofilms: after 2 h of exposure, moderate but significant dispersion was measured. After 6 h of exposure, the number of cells transitioning from the biofilm to the planktonic state was up to 0.6 log higher when compared with non-treated biofilms. To further explore the transport processes of NO donors within hydrogels, we measured the nitric oxide flux from gels, at 25°C for a composite of 0.1 µM MAHMA NONOate-CNC. Nitric oxide diffuses up to 500 µm from the hydrogel surface, with flux decreasing according to Fick's law. 60% of NO was released from the hydrogel composite during the first 23 min. These data suggest that the combined treatments with nitric oxide donor and hydrogels may allow for new sustainable cleaning strategies.

12.
Analyst ; 139(3): 660-7, 2014 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-24336219

RESUMO

Carbon and noble metal nanomaterials exhibit unique properties that have been explored over the last few decades for developing electrochemical sensors and biosensors. Hybridization of nanometals to carbon nanomaterials such as graphene or carbon nanotubes produces a synergistic effect on the electrocatalytic activity when compared to either material alone. However, to date there are no comparative studies that directly investigate the effects of nanocarbon concentration and nanocomposite arrangement on electron transport. This comparative study investigated the efficacy of various platinum-carbon hybrid nanostructures for amperometric biosensing. Electroactive surface area, sensitivity towards hydrogen peroxide, response time, limit of detection, and surface roughness were measured for various hybrid nanomaterial arrangements. Both design factors (nanocarbon concentration and network arrangement) influenced the performance of the reduced graphene oxide-based platforms; whereas only nanomaterial arrangement affected the performance of the carbon nanotube-composites. The highest sensitivity towards hydrogen peroxide for reduced graphene oxide nanocomposites (45 ± 3.2 µA mM(-1)) was measured for a graphene concentration of 2 mg mL(-1) in a "sandwich" structure; nanoplatinum layers enveloping the reduced graphene oxide. Likewise, the best carbon nanotube performance toward H2O2 (49 ± 1.4 µA mM(-1)) was measured for a sandwich-type structure with nanoplatinum. The enhanced electrocatalytic activity of this "sandwich" structure was due to a combined effect of electrical junctions formed amongst nanocarbon, and nanocomposite soldering to the electrode surface. The top-down carbon-platinum hybrid nanocomposites in this paper represent a simple, low-cost, approach for formation of high fidelity amperometric sensors with remarkable performance characteristics that are similar to bottom-up fabrication approaches.


Assuntos
Técnicas Biossensoriais/métodos , Grafite/química , Nanoestruturas/química , Platina/química , Técnicas Biossensoriais/instrumentação , Eletroquímica , Peróxido de Hidrogênio/análise , Peróxido de Hidrogênio/química , Óxidos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...