Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Radiol Open ; 12: 100558, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38482518

RESUMO

Objectives: Computed tomography pulmonary angiography (CTPA) is the gold standard diagnostic method for patients with suspected pulmonary embolism (PE), but it has its drawbacks, including exposure to ionizing radiation and iodinated contrast agent. The present study aims to evaluate the diagnostic performance of our in-house developed non-contrast MRI protocol for PE diagnosis in reference to CTPA. Methods: 107 patients were included, all of whom underwent MRI immediately before or within 36 hours after CTPA. Additional cases examined only with MRI and a negative result were added to reach a PE prevalence of approximately 20%. The protocol was a non-contrast 2D steady-state free precession (SSFP) sequence under free-breathing, without respiratory or cardiac gating, and repeated five times to capture the vessels at different breathing/cardiac phases. The MRIs were blinded and read by two radiologists and the results were compared to CTPA. Results: Of the 243 patients included, 47 were positive for PE. Readers 1 and 2 demonstrated 89% and 87% sensitivity, 100% specificity, 98% accuracy and Cohen's kappa of 0.88 on patient level. In the per embolus comparison, readers 1 and 2 detected, 60 and 59/61 (98, 97%) proximal, 101 and 94/113 (89, 83%) segmental, and 5 and 2/32 (16, 6%) subsegmental emboli, resulting in 81 and 75% sensitivity respectively. Conclusion: The repeated 2D SSFP can reliably be used for the diagnosis of acute PE at the proximal and segmental artery levels.

2.
Nat Commun ; 12(1): 2417, 2021 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-33893295

RESUMO

SARS-CoV-2 uses ACE2, an inhibitor of the Renin-Angiotensin-Aldosterone System (RAAS), for cellular entry. Studies indicate that RAAS imbalance worsens the prognosis in COVID-19. We present a consecutive retrospective COVID-19 cohort with findings of frequent pulmonary thromboembolism (17%), high pulmonary artery pressure (60%) and lung MRI perfusion disturbances. We demonstrate, in swine, that infusing angiotensin II or blocking ACE2 induces increased pulmonary artery pressure, reduces blood oxygenation, increases coagulation, disturbs lung perfusion, induces diffuse alveolar damage, and acute tubular necrosis compared to control animals. We further demonstrate that this imbalanced state can be ameliorated by infusion of an angiotensin receptor blocker and low-molecular-weight heparin. In this work, we show that a pathophysiological state in swine induced by RAAS imbalance shares several features with the clinical COVID-19 presentation. Therefore, we propose that severe COVID-19 could partially be driven by a RAAS imbalance.


Assuntos
COVID-19/fisiopatologia , Pulmão/fisiopatologia , Sistema Renina-Angiotensina/fisiologia , SARS-CoV-2/isolamento & purificação , Angiotensina II/administração & dosagem , Angiotensina II/metabolismo , Antagonistas de Receptores de Angiotensina/administração & dosagem , Enzima de Conversão de Angiotensina 2/antagonistas & inibidores , Enzima de Conversão de Angiotensina 2/metabolismo , Animais , COVID-19/metabolismo , COVID-19/virologia , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pulmão/virologia , Imageamento por Ressonância Magnética/métodos , Ligação Proteica/efeitos dos fármacos , Estudos Retrospectivos , SARS-CoV-2/metabolismo , SARS-CoV-2/fisiologia , Glicoproteína da Espícula de Coronavírus/metabolismo , Suínos , Internalização do Vírus/efeitos dos fármacos
3.
Eur J Radiol Open ; 6: 315-319, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31692624

RESUMO

PURPOSE: To follow up the clinical outcome of patients with suspected pulmonary embolism (PE), in those only imaged using unenhanced, free-breathing magnetic resonance imaging (MRI). METHODS AND MATERIALS: Fifty-seven patients aged 29-99 years (mean 70, SD 18) that could not undergo Computed Tomography Pulmonary Angiography (CTPA) were offered alternative imaging diagnostics in parallel with ongoing methodological studies validating MRI vs CTPA. Contraindications included renal failure (n = 44), severe iodine contrast allergy (n = 10), pregnancy (n = 2) and radioactive iodine therapy (n = 1). The unenhanced MRI protocol was based on free-breathing, steady-state free precession with no cardiac or respiratory gating. Retrospective review of the electronic medical record (EMR) was made of 0-12 months post-imaging and was collected during 2012-2018. RESULTS: All 57 MRIs were of diagnostic quality and 12 pulmonary embolisms were diagnosed. Of the 57 patients, 44 were already on, or had started anticoagulation therapy due to clinical suspicion of PE. Four of the patients were put on anticoagulation after the positive MRI and 13 were taken off anticoagulation after a negative MRI report. Other diagnoses reported (considering dyspnea) were pleural effusion (n = 24), consolidation (n = 12) and pericardial effusion (n = 2). One patient had a deep vein thrombosis (DVT) within three months of our negative MRI result and then had a stroke within one year. Another patient suffered a stroke within three months of being diagnosed (by MRI) with PE and given anticoagulation as treatment. CONCLUSIONS: Our method supported or altered clinical decision-making and treatment in this cohort. A diagnostic tool for PE without intravenous contrast agent or radiation is of great benefit for certain patients.

4.
Acta Radiol Open ; 7(6): 2058460118783013, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30013795

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) can be an alternative method to computed tomography angiography (CTA) for pulmonary embolism. PURPOSE: To evaluate the feasibility of diffusion-weighted imaging (DWI) detecting acute pulmonary embolism (PE) in free-breathing humans. MATERIAL AND METHODS: Twenty patients with PE verified by CTA and 20 controls were investigated with MRI (1.5 Aera, Siemens Healthcare). All sequences were performed in the transversal plane using free-breathing without gating. The protocol consisted of a two-dimensional steady-state free precession (SSFP) and a single-shot DWI echo-planar imaging sequence with a voxel resolution of 2 × 2 × 5 mm. Three b values were used: 50, 400, and 800 s/mm2. Images were analyzed in two orders: an open source analysis (OSA); and a blinded only DWI analysis (BDA) simulating clinical work. RESULTS: OSA of corresponding images showed 370 findings on CTA (i.e. one elongated emboli could be represented in multiple images). SSFP identified 237 of those (64%). DWI with b values of 50, 400, and 800 identified 327 (88%), 245 (66%), and 138 (37%), respectively. In BDA we found 160 true emboli (according to CTA) on b50, 78 on b400, and 54 on b800. Fifty-two of these findings at the subsegmental level could be correlated to PE on CTA but were not visible on SSFP. CONCLUSIONS: DWI has a high sensitivity for detecting PE but suffers from poor specificity. It could potentially be used as an eye catcher, i.e. where to look for PE in other MRI sequences.

5.
Magn Reson Med ; 80(5): 1847-1856, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29542200

RESUMO

PURPOSE: To evaluate the feasibility of an improved motion and flow robust methodology for imaging the pulmonary vasculature using non-contrast-enhanced, free-breathing, golden-angle radial MRI. METHODS: Healthy volunteers (n = 10, age 46 ± 11 years, 50% female) and patients (n = 2, ages 27 and 84, both female) were imaged at 1.5 T using a Cartesian and golden-angle radial 2D balanced SSFP pulse sequence. The acquisitions were made under free breathing without contrast agent enhancement. The radial acquisitions were reconstructed at 3 temporal footprints. All series were scored from 1 to 5 for perceived diagnostic quality, artifact level, and vessel sharpness in multiple anatomical locations. In addition, vessel sharpness and blood-to-blood clot contrast were measured. RESULTS: Quantitative measurements showed higher vessel sharpness for golden-angle radial (n = 76, 0.79 ± 0.11 versus 0.71 ± 0.16, p < .05). Blood-to-blood clot contrast was found to be 23% higher in golden-angle radial in the 2 patients. At comparable temporal footprints, golden-angle radial was scored higher for diagnostic quality (mean ± SD, 2.3 ± 0.7 versus 2.2 ± 0.6, p < .01) and vessel sharpness (2.2 ± 0.8 versus 2.1 ± 0.5, p < .01), whereas the artifact level did not differ (3.0 ± 0.9 versus 3.0 ± 1.0, p = .80). The ability to retrospectively choose a temporal resolution and perform sliding-window reconstructions was demonstrated in patients. CONCLUSION: In pulmonary artery imaging, the motion and flow robustness of a radial trajectory does both improve image quality over Cartesian trajectory in healthy volunteers, and allows for flexible selection of temporal footprints and the ability to perform real-time sliding window reconstructions, which could potentially provide further diagnostic insight.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Artéria Pulmonar/diagnóstico por imagem , Adulto , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas
6.
Acta Radiol ; 58(3): 272-278, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27273375

RESUMO

Background Pulmonary embolism (PE) is a severe medical condition with non-specific clinical findings. Computed tomography angiography (CTA) using iodinated contrast agents is the golden standard for diagnosis, but many patients have contraindications for CTA. Purpose To investigate the diagnostic accuracy of repeated acquisitions of magnetic resonance imaging (MRI), without respiratory gating or breath holding, in diagnosing PE using CTA as the reference standard. Material and Methods Thirty-three patients with clinically suspected PE underwent MRI within 48 h after diagnostic CTA. A control group of 37 healthy participants underwent MRI and was matched with an equal number of negative CTA exams. The MRI protocol was based on free-breathing steady-state free precession producing 4.5 mm slices in axial, sagittal, and coronal planes. Instead of respiratory or cardiac gating five repetitive slices were obtained in each anatomical position to compensate for movement and artifacts. Clinical assessment including d-dimer and Well's score was performed prior to imaging. One radiologist reviewed the CTA exams and two radiologists reviewed the MRI scans. Results All 70 MRI exams were of diagnostic quality and the total acquisition time for each MRI scan was 9 min 34 s. On CTA, 29 patients were diagnosed with PE and the MRI readers detected 26 and 27 of those, respectively. Specificity was 100% for both readers. Sensitivity was 90% and 93%, respectively. Inter-reader agreement using Cohen's kappa was 0.97. Conclusion Our unenhanced MRI protocol shows a high sensitivity and specificity for PE, but further studies are required before considering it as a safe diagnostic test.


Assuntos
Imageamento por Ressonância Magnética/métodos , Embolia Pulmonar/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar/diagnóstico por imagem , Reprodutibilidade dos Testes , Respiração , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...