Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pharm Biomed Anal ; 40(2): 360-8, 2006 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-16112830

RESUMO

A simple, sensitive and rapid liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of gabapentin, a new antiepileptic drug, in human plasma using its structural analogue, 1,1-cyclohexane diacetic acid monoamide (CAM) as internal standard. The method involved a simple protein precipitation by means of acetonitrile followed by a rapid isocratic elution with 10mM ammonium formate buffer/acetonitrile (20/80, v/v, pH 3.0) on Waters Symmetry C(18 reversed phase chromatographic column and analyzed by mass spectrometry in the multiple reaction monitoring mode. The precursor to product ion transitions of m/z 172-->154 and m/z 200-->182 were used to measure the analyte and the IS, respectively. The assay exhibited a linear dynamic range of 40-10000 ng/mL for gabapentin in human plasma. The limit of detection and lower limit of quantification in human plasma were 10 and 40 ng/mL, respectively. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 2 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.


Assuntos
Aminas/sangue , Anticonvulsivantes/sangue , Cromatografia Líquida/métodos , Ácidos Cicloexanocarboxílicos/sangue , Ácido gama-Aminobutírico/sangue , Aminas/administração & dosagem , Ácidos Cicloexanocarboxílicos/administração & dosagem , Estabilidade de Medicamentos , Gabapentina , Humanos , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray , Temperatura , Fatores de Tempo , Ácido gama-Aminobutírico/administração & dosagem
2.
J Pharm Biomed Anal ; 39(5): 1006-13, 2005 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-16006083

RESUMO

A simple, sensitive and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric method was developed and validated for the quantitation of nebivolol in human plasma. The method involved a simple single-step liquid-liquid extraction with diethyl ether/dichloromethane (70/30). The analyte was chromatographed on Waters symmetry C18 reversed-phase chromatographic column by isocratic elution with water:acetonitrile:formic acid (30:70:0.03, v/v) and analyzed by mass spectrometry in the multiple reaction monitoring mode. The precursor to product ion transitions of m/z 406.4-151.5 and m/z 409.1-228.1 were used to measure the analyte and the internal standard (I.S.), respectively. The chromatographic runtime was 2 min and the weighted (1/x2) calibration curves were linear over the range 50-10,000 pg/mL. The method was validated in terms of accuracy, precision, absolute recovery, freeze-thaw stability, bench-top stability and re-injection reproducibility. The limit of detection and lower limit of quantification in human plasma were 10 and 50 pg/mL, respectively. The within- and between-batch accuracy and precision were found to be well within acceptable limits (<10%). The analyte was stable after three freeze-thaw cycles (deviation <10%). The average absolute recoveries of nebivolol and tamsulosin, used as an internal standard, from spiked plasma samples were 73.4+/-3.7 and 72.1+/-2.0%, respectively. The assay method described here was applied to study the pharmacokinetics of nebivolol.


Assuntos
Antagonistas Adrenérgicos beta/sangue , Benzopiranos/sangue , Etanolaminas/sangue , Antagonistas Adrenérgicos beta/farmacocinética , Benzopiranos/farmacocinética , Calibragem , Cromatografia Líquida de Alta Pressão , Etanolaminas/farmacocinética , Humanos , Nebivolol , Controle de Qualidade , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray
3.
Biomed Chromatogr ; 19(10): 709-19, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15828055

RESUMO

A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of tamsulosin (I), a highly selective alpha1-adrenoceptor antagonist used for the treatment of patients with symptomatic benign prostatic hyperplasia. The analyte and internal standard, mosapride (II) were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on a reverse phase Waters symmetry C18 column with a mobile phase of 0.03% formic acid-acetonitrile (30:70, v/v). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 409.1 solidus in circle 228.1 and m/z 422.3 solidus in circle 198.3 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.1-50.0 ng/mL for tamsulosin in human plasma. The lower limit of quantitation was 100 pg/mL with a relative standard deviation of less than 10%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 2.0 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.


Assuntos
Antagonistas Adrenérgicos alfa/sangue , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Sulfonamidas/sangue , Antagonistas Adrenérgicos alfa/farmacocinética , Estabilidade de Medicamentos , Humanos , Sensibilidade e Especificidade , Sulfonamidas/farmacocinética , Tansulosina
4.
Biomed Chromatogr ; 19(10): 751-60, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15856489

RESUMO

A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of hydrochlorothiazide (I), a common diuretic and anti-hypertensive agent. The analyte and internal standard, tamsulosin (II) were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on a reversed-phase column (Waters symmetry C18) with a mobile phase of 10 mm ammonium acetate-methanol (15:85, v/v). The protonated analyte was quantitated in negative ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 296.1 solidus in circle 205.0 and m/z 407.2 solidus in circle 184.9 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.5-200 ng/mL for hydrochlorothiazide in human plasma. The lower limit of quantitation was 500 pg/mL, with a relative standard deviation of less than 9%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 2.5 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.


Assuntos
Antidiuréticos/sangue , Anti-Hipertensivos/sangue , Cromatografia Líquida de Alta Pressão/métodos , Hidroclorotiazida/sangue , Espectrometria de Massas/métodos , Estabilidade de Medicamentos , Humanos , Hidroclorotiazida/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Biomed Chromatogr ; 19(7): 539-48, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15654725

RESUMO

A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of mosapride (I), a novel and potent gastroprokinetic agent that enhances the upper gastrointestinal motility by stimulating 5-HT(4) receptor. The analyte and internal standard, tamsulosin (II), were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on a reversed-phase Waters symmetry C(18) column with a mobile phase of 0.03% formic acid-acetonitrile (10:90, v/v). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 422.3 -->198.3 and m/z 409.1 -->228.1 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.5-100.0 ng/mL for mosapride in human plasma. The lower limit of quantitation was 500 pg/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 2.0 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.


Assuntos
Benzamidas/sangue , Cromatografia Líquida de Alta Pressão/métodos , Morfolinas/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Estabilidade de Medicamentos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...