Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 85(11): 11E108, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430287

RESUMO

A matrix of Silicon Photo Multipliers has been developed for light readout from a large area 1 in. × 1 in. LaBr3 crystal. The system has been characterized in the laboratory and its performance compared to that of a conventional photo multiplier tube. A pulse duration of 100 ns was achieved, which opens up to spectroscopy applications at high counting rates. The energy resolution measured using radioactive sources extrapolates to 3%-4% in the energy range Eγ = 3-5 MeV, enabling gamma-ray spectroscopy measurements at good energy resolution. The results reported here are of relevance in view of the development of compact gamma-ray detectors with spectroscopy capabilities, such as an enhanced gamma-ray camera for high power fusion plasmas, where the use of photomultiplier is impeded by space limitation and sensitivity to magnetic fields.

2.
Rev Sci Instrum ; 85(6): 065102, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24985847

RESUMO

LUPIN-II is an upgraded version of LUPIN, a novel rem counter first developed in 2010 specifically conceived to work in pulsed neutron fields (PNFs). The new version introduces some modifications that improve the performance of the detector, in particular extending its upper detection limit in PNFs. This paper discusses the characteristics and the performance of the instrument. Measurements have been carried out in radiation fields characterized by very different conditions: the detector has first been exposed in PNFs with intensity up to 5 µSv per burst, where it could keep the H*(10) underestimation below 20% up to 500 nSv per burst. It has then been tested in operational conditions around particle accelerators, where it has shown performances similar to that of ionization chambers. Its proper functioning has also been verified in high energy mixed fields, where the experimental results matched the Monte Carlo predictions. Its neutron/photon discrimination capability has been tested in a steady-state photon field where, via an innovative technique based on a threshold set on the derivative of the current signal, it was capable of rejecting a photon H*(10) rate of about 25 mSv/h, and in a mixed neutron/photon field, where a time-based discrimination method was employed.


Assuntos
Modelos Teóricos , Nêutrons , Espalhamento de Radiação
3.
Radiat Prot Dosimetry ; 143(2-4): 432-5, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21147791

RESUMO

A silicon device based on the monolithic silicon telescope technology coupled to a tissue-equivalent converter was proposed and investigated for solid state microdosimetry. The detector is constituted by a ΔE stage about 2 µm in thickness geometrically segmented in a matrix of micrometric diodes and a residual-energy measurement stage E about 500 µm in thickness. Each thin diode has a cylindrical sensitive volume 9 µm in nominal diameter, similar to that of a cylindrical tissue-equivalent proportional counter (TEPC). The silicon device and a cylindrical TEPC were irradiated in the same experimental conditions with quasi-monoenergetic neutrons of energy between 0.64 and 2.3 MeV at the INFN-Legnaro National Laboratories (LNL-INFN, Legnaro, Italy). The aim was to study the capability of the silicon-based system of reproducing microdosimetric spectra similar to those measured by a reference microdosemeter. The TEPC was set in order to simulate a tissue site about 2 µm in diameter. The spectra of the energy imparted to the ▵E stage of the silicon telescope were corrected for tissue-equivalence through an optimized procedure that exploits the information from the residual energy measurement stage E. A geometrical correction based on parametric criteria for shape-equivalence was also applied. The agreement between the dose distributions of lineal energy and the corresponding mean values is satisfactory at each neutron energy considered.


Assuntos
Astronomia/instrumentação , Desenho Assistido por Computador , Monitoramento de Radiação/instrumentação , Silício/efeitos da radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Radiat Prot Dosimetry ; 114(4): 469-74, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15829553

RESUMO

The availability of low cost personal dosemeters is very important for routine worker monitoring. The aim of this work is to evaluate the performance of commercial silicon diodes, commonly used for infrared communication, as a personal radiation monitor. The instrument prototype was characterised both as an area monitor and a personal monitor. Instrument response was measured in the energy range form 37 keV to (60)Co energy. The angular response was also evaluated too.


Assuntos
Monitoramento de Radiação/instrumentação , Silício/efeitos da radiação , Transdutores , Relação Dose-Resposta à Radiação , Eletrônica , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Doses de Radiação , Monitoramento de Radiação/métodos
5.
Phys Med Biol ; 44(5): N69-75, 1999 May.
Artigo em Inglês | MEDLINE | ID: mdl-10368029

RESUMO

A novel coupling method that optimizes the axial RF distribution of low-frequency EPR loop-gap resonators is presented. It consists of a resonant coupling loop positioned at the centre of a two-section loop-gap resonator. This arrangement ensures a symmetrical distribution of the radio frequency field along the axis of the resonator. The design of a central coupling system suitable for EPR resonators operating at about 220 MHz is described. Experimental results show that with the central coupling system the RF field is symmetrical and has a very good axial homogeneity (100% of the resonator length).


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/métodos , Ondas de Rádio , Fenômenos Biofísicos , Biofísica , Espectroscopia de Ressonância de Spin Eletrônica/instrumentação , Espectroscopia de Ressonância de Spin Eletrônica/estatística & dados numéricos , Eletrônica Médica/instrumentação , Desenho de Equipamento , Estudos de Avaliação como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...