Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Mikrochim Acta ; 191(9): 558, 2024 08 23.
Artigo em Inglês | MEDLINE | ID: mdl-39177820

RESUMO

An innovative supramolecular architecture is reported for bienzymatic glucose biosensing based on the use of a nanohybrid made of multi-walled carbon nanotubes (MWCNTs) non-covalently functionalized with a Schiff base modified with two phenylboronic acid residues (SB-dBA) as platform for the site-specific immobilization of the glycoproteins glucose oxidase (GOx) and horseradish peroxidase (HRP). The analytical signal was obtained from amperometric experiments at - 0.050 V in the presence of 5.0 × 10-4 M hydroquinone as redox mediator. The concentration of GOx and HRP and the interaction time between the enzymes and the nanohybrid MWCNT-SB-dBA deposited at glassy carbon electrodes (GCEs) were optimized through a central composite design (CCD)/response surface methodology (RSM). The optimal concentrations of GOx and HRP were 3.0 mg mL-1 and 1.50 mg mL-1, respectively, while the optimum interaction time was 3.0 min. The bienzymatic biosensor presented a sensitivity of (24 ± 2) × 102 µA dL mg-1 ((44 ± 4) × 102 µA M-1), a linear range between 0.06 mg dL-1 and 21.6 mg dL-1 (3.1 µM-1.2 mM) (R2 = 0.9991), and detection and quantification limits of 0.02 mg dL-1 (1.0 µM) and 0.06 mg dL-1 (3.1 µM), respectively. The reproducibility for five sensors prepared with the same MWCNT-SB-dBA nanohybrid was 6.3%, while the reproducibility for sensors prepared with five different nanohybrids and five electrodes each was 7.9%. The GCE/MWCNT-SB-dBA/GOx-HRP was successfully used for the quantification of glucose in artificial human urine and commercial human serum samples.


Assuntos
Técnicas Biossensoriais , Ácidos Borônicos , Enzimas Imobilizadas , Glucose Oxidase , Peroxidase do Rábano Silvestre , Nanotubos de Carbono , Bases de Schiff , Nanotubos de Carbono/química , Bases de Schiff/química , Técnicas Biossensoriais/métodos , Ácidos Borônicos/química , Glucose Oxidase/química , Glucose Oxidase/metabolismo , Peroxidase do Rábano Silvestre/química , Peroxidase do Rábano Silvestre/metabolismo , Humanos , Enzimas Imobilizadas/química , Enzimas Imobilizadas/metabolismo , Glucose/análise , Eletrodos , Limite de Detecção , Técnicas Eletroquímicas/métodos , Glicemia/análise
2.
J Pharm Biomed Anal ; 232: 115370, 2023 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-37163830

RESUMO

The COVID-19 pandemic had devastating effects throughout the world, producing a severe crisis in the health systems and in the economy of a long list of countries, even developed ones. Therefore, highly sensitive and selective analytical bioplatforms that allow the descentralized and fast detection of the severe acute respiratory síndrome coronavirus 2 (SARS-CoV-2), are extremely necessary. Since 2020, several reviews have been published, most of them focused on the different strategies to detect the SARS-CoV-2, either from RNA, viral proteins or host antibodies produced due to the presence of the virus. In this review, the most relevant biosensors for the detection of SARS-CoV-2 RNA are particularly addressed, with special emphasis on the discussion of the biorecognition layers and the different schemes for transducing the hybridization event.


Assuntos
Técnicas Biossensoriais , COVID-19 , Ácidos Nucleicos , Humanos , SARS-CoV-2 , COVID-19/diagnóstico , RNA Viral/genética , Pandemias
3.
Mikrochim Acta ; 190(2): 73, 2023 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-36695940

RESUMO

An innovative strategy is proposed to simultaneously exfoliate multi-walled carbon nanotubes (MWCNTs) and generate MWCNTs with immunoaffinity properties. This strategy was based on the non-covalent functionalization of MWCNTs with human immunoglobulin G (IgG) by sonicating 2.5 mg mL-1 MWCNTs in 2.0 mg mL-1 IgG for 15 min with sonicator bath. Impedimetric experiments performed at glassy carbon electrodes (GCE) modified with the resulting MWCNT-IgG nanohybrid in the presence of anti-human immunoglobulin G antibody (Anti-IgG) demonstrated that the immunoglobulin retains their biorecognition properties even after the treatment during the MWCNT functionalization. We proposed, as proof-of-concept, two model electrochemical sensors, a voltammetric one for uric acid quantification by taking advantages of the exfoliated MWCNTs electroactivity (linear range, 5.0 × 10-7 M - 5.0 × 10-6 M; detection limit, 165 nM) and an impedimetric immunosensor for the detection of Anti-IgG through the use of the bioaffinity properties of the IgG present in the nanohybrid (linear range, 5-50 µg mL-1; detection limit, 2 µg mL-1).


Assuntos
Técnicas Biossensoriais , Nanotubos de Carbono , Humanos , Técnicas Biossensoriais/métodos , Nanotubos de Carbono/química , Imunoensaio , Imunoglobulina G , Eletrodos
4.
Analyst ; 147(10): 2130-2140, 2022 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-35421882

RESUMO

This work presents for the first time the systematic preparation of a novel carbon nanotube-MCM-41 hybrid employing the mesoporous material MCM-41 as a successful dispersant for multiwall carbon nanotubes (MWCNTs). Relevant dispersion variables such as the amount of MWCNTs, MCM-41 concentration, and sonication time were optimized through a central composite design (CDD)/response surface methodology (RSM). Several solvents were evaluated and N,N-dimethylformamide (DMF) was selected because it allowed reaching stable dispersions with very good electrochemical response. The electrochemical performance of glassy carbon electrodes (GCE) modified with different hybrids was evaluated by cyclic voltammetry (CV) using ascorbic acid (AA) as redox marker, while their surface morphology was characterized by SEM microscopy. The optimal MWCNT-MCM-41 dispersion condition was 0.75 mg mL-1 MWCNTs, 0.25 mg mL-1 MCM-41, and 30 min sonication. Both, electrochemical results and SEM images correlate with a percolation behavior from MWCNT-MCM-41 hybrid. Electrooxidation of AA at GCE modified with the optimal hybrid occurred under diffusion control and exhibited an enhanced current response (65 µA) and a lower overvoltage (-0.005 V) compared to bare GCE (ip = 22 µA, Ep = 0.255 V). The amperometric response of AA at GCE/MWCNT-MCM-41 exhibited remarkable figures of merit, including an ultralow detection limit (1.5 nM), high sensitivity (45.4 × 103 µA M-1), excellent short- and long-term stability, and very good anti-interference ability for AA detection. The analytical applicability of the developed electrochemical sensor was evaluated by sensing AA in several real samples, showing excellent correlation with the values reported by manufacturers in both pharmaceutical and food samples.


Assuntos
Nanotubos de Carbono , Ácido Ascórbico/química , Técnicas Eletroquímicas/métodos , Eletrodos , Nanotubos de Carbono/química , Dióxido de Silício
5.
J Pharm Biomed Anal ; 189: 113478, 2020 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-32768875

RESUMO

MicroRNAs (miRNAs) are non-coding regulatory RNAs that play an important role in RNA silencing and post-transcriptional gene expression regulation. Since their dysregulation has been associated with Alzheimer disease, cardiovascular diseases and different types of cancer, among others, miRNAs can be used as biomarkers for early diagnosis and prognosis of these diseases. The methods commonly used to quantify miRNAs are, in general, complex, costly, with limited application for point-of-care devices or resource-limited facilities. Electrochemical biosensors, mainly those based on nanomaterials, have emerged as a promising alternative to the conventional miRNA detection methods and have paved the way to the development of sensitive, fast, and low-cost detection systems. This review is focused on the most relevant contributions performed in the field of electrochemical miRNAs biosensors between 2017 and the beginning of 2020. The main contribution of this article is the critical discussion of the different amplification strategies and the comparative analysis between amplified and non-amplified miRNA electrochemical biosensing and between the different amplification schemes. Particular emphasis was given to the importance of the nanostructures, enzymes, labelling molecules, and special sequences of nucleic acids or analogues on the organization of the different bioanalytical platforms, the transduction of the hybridization event and the generation the analytical signal.


Assuntos
Técnicas Biossensoriais , MicroRNAs , Nanoestruturas , Técnicas Eletroquímicas , MicroRNAs/genética , Hibridização de Ácido Nucleico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA