1.
J Neurovirol ; 27(6): 810-819, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33528826

RESUMO

The association between high proviral load (PVL) in peripheral blood mononuclear cells (PBMC), cognitive disturbance and white matter brain lesions in HTLV-1-infected individuals is still undefined. A cross-sectional study included 62 participants: 22 asymptomatic carriers (mean age 43.4 ± 13.1 years old), 22 patients with HTLV-1-associated myelopathy (HAM/TSP) (mean age 51.5 ± 8.7 years old), and 18 uninfected controls (mean age 52.3 ± 11.1 years old). All individuals fulfilled the following criteria: between 18 and 65 years of age, more than 4 years of formal education, and completed neuropsychological evaluation and HTLV-1 serology. Infected individuals underwent brain conventional magnetic resonance imaging and PVL quantitative PCR (qPCR). Statistical analysis was adjusted in the models by age and education. Cognitive deficit was observed in all groups. Patients with HAM/TSP showed higher neurocognitive deviation in attention and motor skills, higher frequency (84%) of brain white matter lesions, and higher PVL median (range) 8.45 (0.5-71.4) copies/100 PBMC. Brain white matter lesion was associated with verbal memory deficit in HTLV-1-infected individuals (HAM/TSP and asymptomatic carriers) (p = 0.026). In addition, there was a correlation between higher PVL and neurocognitive dysfunction score (processing speed of visuomotor information and visuoconstructive praxis) in HTLV-1-infected patients. The study demonstrates an association between HTLV-1 infection, neurocognitive disorder, and white matter brain lesions on MRI as well as a correlation with higher HTLV-1 PVL, suggesting that the central nervous system involvement by HTLV-1 is not restricted to the spinal cord but involves the whole neuro-axis. HTLV-1-infected individuals should be tested for cognitive impairment.


Assuntos
Disfunção Cognitiva , Vírus Linfotrópico T Tipo 1 Humano , Substância Branca , Adulto , Encéfalo/diagnóstico por imagem , Pré-Escolar , Disfunção Cognitiva/diagnóstico por imagem , Estudos Transversais , Vírus Linfotrópico T Tipo 1 Humano/fisiologia , Humanos , Leucócitos Mononucleares , Pessoa de Meia-Idade , Provírus/genética , Carga Viral , Substância Branca/diagnóstico por imagem
2.
Braz. j. infect. dis ; 24(1): 30-33, Feb. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1089321

RESUMO

ABSTRACT A new point-of-care HIV viral load, mPIMA HIV-1/2 VL, Abbott, USA, has been recently developed. This point-of-care viral load requires no skilled person to run and uses a small plasma volume (50 µL). However, obtaining 50 µL of plasma can be a challenge in limited resource settings. We validated a simple and easy method to obtain enough amount of plasma to run a point-of-care viral load. The study utilized 149 specimens from patients failing antiretroviral therapy. At least 250 µL of whole blood was collected in a microtube/EDTA from fingerstick (fs-plasma) and immediately centrifuged. Parallel collection of venous blood to obtain plasma (vp-plasma) was used to compare performance in a point-of-care viral load assay and in methodology used in centralized laboratories Abbott M2000, Abbott, USA. The procedure for plasma collection takes less than 10 min and in 94% of the cases only one fingerstick was sufficient to collect at least 250 µL of blood. The Pearson correlation coefficient value for vp-plasma versus fs-plasma ran on mPIMA was 0.990. The Bland-Altman mean difference (md) for this comparison were virtually zero (md = −0.001) with limits of agreement between −0.225 and 0.223. In addition, the Pearson correlation coefficient value for fs-plasma in mPIMA versus vp-plasma in Abbott M2000 was 0.948 for values above the mPIMA limit of quantification (LoQ; from 800 to 1,000,000 copies/mL). These results validate this simple plasma isolation method capable to be implemented in low resource countries where point-of-care decentralization is deeply needed.


Assuntos
Humanos , Plasma/virologia , HIV/isolamento & purificação , Sistemas Automatizados de Assistência Junto ao Leito , Carga Viral/métodos , Infecções por HIV/sangue , Infecções por HIV/virologia , Modelos Lineares , Estudos de Viabilidade , Reprodutibilidade dos Testes
3.
J Clin Virol ; 122: 104212, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31765957

RESUMO

BACKGROUND: A new point-of-care (POC) HIV virus load technology has been recently developed and designed to be utilized in decentralized settings. Alere Technologies GmbH*, Germany, developed the mPIMA HIV-1/2 VL plasma test which uses real time PCR technology with 50 µl and a turnaround time of one hour. OBJECTIVE: Analyze the performance of mPIMA to detect and quantify HIV-1 and HIV-2 and compare with Abbott M2000 assay fooling patients HIV-1 failing ARV therapy. STUDY DESIGN: In this study we evaluate the mPIMA HIV-1/2 VL plasma test using 413 specimens from 270 patients failing ARV therapy, and compared its performance with Abbott RealTime HIV-1 Viral Load assay on the m2000 system. In addition, were determined VL in plasma specimens obtained from HIV-2 infected patients. RESULTS: The results strongly indicate that mPIMA HIV-1/2 VL plasma test can determine HIV-1 with concordance of 88.9 % (95 % CI 85.4-91.7) the reference test when 1000 HIV-1 VL threshold was used as WHO cutoff to identify therapy failure. The overall correlation between HIV-1 VL was 0928 (Pearson correlation coefficient of Linear regression) and the Bland-Altman showed a mean difference of -0.20 Log cp/mL between the two technology. mPIMA HIV-1/2 VL plasma test was also able to measure HIV-2 viral load in 16 specimens from Guinea-Bissau HIV-1/HIV-2 positive samples. CONCLUSIONS: These data support the use of mPIMA HIV-1/2 VL plasma test to follow up patients and select patients failing ART, guiding immediate clinical decisions such as adherence counseling or ART regimen switch during the patient consultation.


Assuntos
Infecções por HIV/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito/normas , RNA Viral/sangue , Carga Viral/instrumentação , Carga Viral/métodos , Fármacos Anti-HIV/uso terapêutico , Alemanha , Infecções por HIV/sangue , Infecções por HIV/tratamento farmacológico , HIV-1/isolamento & purificação , HIV-2/isolamento & purificação , Humanos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Sensibilidade e Especificidade
4.
Braz J Infect Dis ; 24(1): 30-33, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31760036

RESUMO

A new point-of-care HIV viral load, mPIMA HIV-1/2 VL, Abbott, USA, has been recently developed. This point-of-care viral load requires no skilled person to run and uses a small plasma volume (50µL). However, obtaining 50µL of plasma can be a challenge in limited resource settings. We validated a simple and easy method to obtain enough amount of plasma to run a point-of-care viral load. The study utilized 149 specimens from patients failing antiretroviral therapy. At least 250µL of whole blood was collected in a microtube/EDTA from fingerstick (fs-plasma) and immediately centrifuged. Parallel collection of venous blood to obtain plasma (vp-plasma) was used to compare performance in a point-of-care viral load assay and in methodology used in centralized laboratories Abbott M2000, Abbott, USA. The procedure for plasma collection takes less than 10min and in 94% of the cases only one fingerstick was sufficient to collect at least 250µL of blood. The Pearson correlation coefficient value for vp-plasma versus fs-plasma ran on mPIMA was 0.990. The Bland-Altman mean difference (md) for this comparison were virtually zero (md=-0.001) with limits of agreement between -0.225 and 0.223. In addition, the Pearson correlation coefficient value for fs-plasma in mPIMA versus vp-plasma in Abbott M2000 was 0.948 for values above the mPIMA limit of quantification (LoQ; from 800 to 1,000,000copies/mL). These results validate this simple plasma isolation method capable to be implemented in low resource countries where point-of-care decentralization is deeply needed.


Assuntos
HIV/isolamento & purificação , Plasma/virologia , Sistemas Automatizados de Assistência Junto ao Leito , Carga Viral/métodos , Estudos de Viabilidade , Infecções por HIV/sangue , Infecções por HIV/virologia , Humanos , Modelos Lineares , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...