Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 113(2): 162-7, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15657109

RESUMO

The purpose of this study was to determine the patient doses during enteroclysis and compare them with the available bibliographical data. For 14 enteroclysis examinations, the dose-area product (DAP) meter readings, fluoroscopy time, number of radiographs and exposure data were recorded. From these data, the fluoroscopy and radiography contributions to DAP, the entrance surface dose (ESD) and the effective dose (E) for each examination were estimated. The mean DAP was 81 Gy cm(2) and the mean fluoroscopy time was 19.5 min. The fluoroscopy contribution to DAP was 77% and 8.7 films were acquired in each examination on average. The mean ESD and E were estimated to be 428 mGy and 21 mSv, respectively. The mean DAP and fluoroscopy time calculated in this study are quite high when compared with those reported in the literature, suggesting that the examination technique should be reviewed and the ways to reduce patient exposure without compromising the diagnostic quality should be acquired.


Assuntos
Fluoroscopia/estatística & dados numéricos , Enteropatias/diagnóstico por imagem , Enteropatias/epidemiologia , Intestino Delgado/diagnóstico por imagem , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Medição de Risco/métodos , Adulto , Idoso , Carga Corporal (Radioterapia) , Feminino , Grécia/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Eficiência Biológica Relativa , Fatores de Risco , Raios X
2.
Abdom Imaging ; 29(4): 426-8, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15024521

RESUMO

Intussusception is a relatively common cause of intestinal obstruction in children but a rare clinical entity in adults, representing fewer than 1% of intestinal obstructions in this patient population. We present a rare case of a 44-year-old female patient with intestinal obstruction due to ileocolic and colocolonic intussusception secondary to an intramural cecal lipoma. Diagnosis was made by barium enema and abdominal computed tomography and was confirmed by colonoscopy. After failure of conservative treatment, the patient underwent surgery.


Assuntos
Neoplasias do Ceco/complicações , Doenças do Íleo/diagnóstico , Intussuscepção/diagnóstico , Lipoma/complicações , Dor Abdominal/etiologia , Adulto , Sulfato de Bário , Neoplasias do Ceco/cirurgia , Colonoscopia/métodos , Enema/métodos , Feminino , Humanos , Doenças do Íleo/etiologia , Doenças do Íleo/cirurgia , Intussuscepção/etiologia , Intussuscepção/cirurgia , Lipoma/cirurgia , Tomografia Computadorizada por Raios X/métodos
3.
Radiat Prot Dosimetry ; 106(3): 241-6, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14690325

RESUMO

The purpose of this investigation was to measure the dose-area product (DAP) and the other relevant dosimetric quantities in diagnostic and therapeutic endoscopic retrograde cholangiopancreatography (ERCP). Furthermore, the dependence of patient dose and image quality on the tube potential was investigated. A DAP meter was used for dose monitoring in seven diagnostic and 21 therapeutic ERCPs. For each ERCP the DAP meter readings, fluoroscopy time, number of radiographs and exposure data were recorded. From these data the fluoroscopy and radiography contributions to DAP, the entrance skin dose and the effective dose for each examination were estimated. For the investigation of the effect of tube potential on patient dose and image quality, a water phantom containing syringes filled with diluted contrast media was used. The average DAP was 13.7 Gy cm2 in diagnostic and 41.8 Gy cm2 in therapeutic ERCP whereas the average fluoroscopy times were 3.1 and 6.0 min respectively. DAP was strongly correlated to the fluoroscopy time. Measurements in the phantom showed that a good compromise between image quality and patient dose is obtained for tube potentials around 80 kV. Therapeutic ERCPs deliver on average higher doses to patients than diagnostic ERCPs. However, for a difficult diagnostic ERCP more patient exposure may be required than for a simple therapeutic ERCP.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Doses de Radiação , Idoso , Calibragem , Relação Dose-Resposta à Radiação , Feminino , Fluoroscopia , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...