Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Circulation ; 145(25): 1811-1824, 2022 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35621277

RESUMO

BACKGROUND: Endomyocardial biopsy (EMB) is the gold standard method for surveillance of acute cardiac allograft rejection (ACAR) despite its invasive nature. Cardiovascular magnetic resonance (CMR)-based myocardial tissue characterization allows detection of myocarditis. The feasibility of CMR-based surveillance for ACAR-induced myocarditis in the first year after heart transplantation is currently undescribed. METHODS: CMR-based multiparametric mapping was initially assessed in a prospective cross-sectional fashion to establish agreement between CMR- and EMB-based ACAR and to determine CMR cutoff values between rejection grades. A prospective randomized noninferiority pilot study was then undertaken in adult orthotopic heart transplant recipients who were randomized at 4 weeks after orthotopic heart transplantation to either CMR- or EMB-based rejection surveillance. Clinical end points were assessed at 52 weeks. RESULTS: Four hundred one CMR studies and 354 EMB procedures were performed in 106 participants. Forty heart transplant recipients were randomized. CMR-based multiparametric assessment was highly reproducible and reliable at detecting ACAR (area under the curve, 0.92; sensitivity, 93%; specificity, 92%; negative predictive value, 99%) with greater specificity and negative predictive value than either T1 or T2 parametric CMR mapping alone. High-grade rejection occurred in similar numbers of patients in each randomized group (CMR, n=7; EMB, n=8; P=0.74). Despite similarities in immunosuppression requirements, kidney function, and mortality between groups, the rates of hospitalization (9 of 20 [45%] versus 18 of 20 [90%]; odds ratio, 0.091; P=0.006) and infection (7 of 20 [35%] versus 14 of 20 [70%]; odds ratio, 0.192; P=0,019) were lower in the CMR group. On 15 occasions (6%), patients who were randomized to the CMR arm underwent EMB for clarification or logistic reasons, representing a 94% reduction in the requirement for EMB-based surveillance. CONCLUSIONS: A noninvasive CMR-based surveillance strategy for ACAR in the first year after orthotopic heart transplantation is feasible compared with EMB-based surveillance. REGISTRATION: HREC/13/SVH/66 and HREC/17/SVH/80. AUSTRALIAN NEW ZEALAND CLINICAL TRIALS REGISTRY: ACTRN12618000672257.


Assuntos
Transplante de Coração , Miocardite , Adulto , Austrália/epidemiologia , Biópsia/métodos , Estudos Transversais , Rejeição de Enxerto/diagnóstico , Transplante de Coração/efeitos adversos , Humanos , Espectroscopia de Ressonância Magnética , Miocardite/diagnóstico , Miocárdio/patologia , Projetos Piloto , Estudos Prospectivos
2.
BMC Res Notes ; 15(1): 181, 2022 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-35570318

RESUMO

OBJECTIVES: Mitral regurgitation (MR) and microvascular obstruction (MVO) are common complications of myocardial infarction (MI). This study aimed to investigate the association between MR in ST-elevation MI (STEMI) subjects with MVO post-reperfusion. STEMI subjects undergoing primary percutaneous intervention were enrolled. Cardiovascular magnetic resonance (CMR) imaging was performed within 48-hours of initial presentation. 4D flow images of CMR were analysed using a retrospective valve tracking technique to quantify MR volume, and late gadolinium enhancement images of CMR to assess MVO. RESULTS: Among 69 patients in the study cohort, 41 had MVO (59%). Patients with MVO had lower left ventricular (LV) ejection fraction (EF) (42 ± 10% vs. 52 ± 8%, P < 0.01), higher end-systolic volume (98 ± 49 ml vs. 73 ± 28 ml, P < 0.001) and larger scar volume (26 ± 19% vs. 11 ± 9%, P < 0.001). Extent of MVO was associated with the degree of MR quantified by 4D flow (R = 0.54, P = 0.0003). In uni-variate regression analysis, investigating the association of CMR variables to the degree of acute MR, only the extent of MVO was associated (coefficient = 0.27, P = 0.001). The area under the curve for the presence of MVO was 0.66 (P = 0.01) for MR > 2.5 ml. We conclude that in patients with reperfused STEMI, the degree of acute MR is associated with the degree of MVO.


Assuntos
Insuficiência da Valva Mitral , Infarto do Miocárdio , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Meios de Contraste , Circulação Coronária , Gadolínio , Humanos , Microcirculação , Insuficiência da Valva Mitral/diagnóstico por imagem , Infarto do Miocárdio/complicações , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Retrospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia
3.
Eur J Prev Cardiol ; 29(1): 251-274, 2022 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-33791783

RESUMO

Preventive cardiology encompasses the whole spectrum of cardiovascular disease (CVD) prevention, at individual and population level, through all stages of life. This includes promotion of cardiovascular (CV) health, management of individuals at risk of developing CVD, and management of patients with established CVD, through interdisciplinary care in different settings. Preventive cardiology addresses all aspects of CV health in the context of the social determinants of health, including physical activity, exercise, sports, nutrition, weight management, smoking cessation, psychosocial factors and behavioural change, environmental, genetic and biological risk factors, and CV protective medications. This is the first European Core Curriculum for Preventive Cardiology, which will help to standardize, structure, deliver, and evaluate training in preventive cardiology across Europe. It will be the basis for dedicated fellowship programmes and a European Society of Preventive Cardiology (EAPC) subspecialty certification for cardiologists, with the intention to improve quality and outcome in CVD prevention.


Assuntos
Cardiologia , Doenças Cardiovasculares , Esportes , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/prevenção & controle , Certificação , Currículo , Exercício Físico , Humanos
5.
Wellcome Open Res ; 6: 73, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34095509

RESUMO

Background: Four-dimensional (4D) flow cardiovascular magnetic resonance imaging (MRI) is an emerging technique used for intra-cardiac blood flow assessment. The role of 4D flow cardiovascular MRI in the assessment of trans-valvular flow in patients with atrial fibrillation (AF) has not previously been assessed. The purpose of this study was to assess the feasibility, image quality, and internal validity of 4D flow cardiovascular MRI in the quantification of trans-valvular flow in patients with AF. Methods: Patients with AF and healthy controls in sinus rhythm underwent cardiovascular MRI, including 4D flow studies. Quality assurance checks were done on the raw data and streamlines. Consistency was investigated by trans-valvular flow assessment between the mitral valve (MV) and the aortic valve (AV). Results: Eight patients with AF (88% male, mean age 62±13 years, mean heart rate (HR) 83±16 beats per minute (bpm)) were included and compared with ten healthy controls (70% male, mean age 41±20 years, mean HR 68.5±9 bpm). All scans were of either good quality with minimal blurring artefacts, or excellent quality with no artefacts. No significant bias was observed between the AV and MV stroke volumes in either healthy controls (-4.8, 95% CI -15.64 to 6.04; P=0.34) or in patients with AF (1.64, 95% CI -4.7 to 7.94; P=0.56). A significant correlation was demonstrated between MV and AV stroke volumes in both healthy controls (r=0.87, 95% CI 0.52 to 0.97; P=0.001) and in AF patients (r=0.82, 95% CI 0.26 to 0.97; P=0.01). Conclusions: In patients with AF, 4D flow cardiovascular MRI is feasible with good image quality, allowing for quantification of trans-valvular flow.

6.
J Cardiovasc Magn Reson ; 18(1): 93, 2016 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-27964736

RESUMO

BACKGROUND: Wave intensity analysis (WIA) of the coronary arteries allows description of the predominant mechanisms influencing coronary flow over the cardiac cycle. The data are traditionally derived from pressure and velocity changes measured invasively in the coronary artery. Cardiovascular magnetic resonance (CMR) allows measurement of coronary velocities using phase velocity mapping and derivation of central aortic pressure from aortic distension. We assessed the feasibility of WIA of the coronary arteries using CMR and compared this to invasive data. METHODS: CMR scans were undertaken in a serial cohort of patients who had undergone invasive WIA. Velocity maps were acquired in the proximal left anterior descending and proximal right coronary artery using a retrospectively-gated breath-hold spiral phase velocity mapping sequence with high temporal resolution (19 ms). A breath-hold segmented gradient echo sequence was used to acquire through-plane cross sectional area changes in the proximal ascending aorta which were used as a surrogate of an aortic pressure waveform after calibration with brachial blood pressure measured with a sphygmomanometer. CMR-derived aortic pressures and CMR-measured velocities were used to derive wave intensity. The CMR-derived wave intensities were compared to invasive data in 12 coronary arteries (8 left, 4 right). Waves were presented as absolute values and as a % of total wave intensity. Intra-study reproducibility of invasive and non-invasive WIA was assessed using Bland-Altman analysis and the intraclass correlation coefficient (ICC). RESULTS: The combination of the CMR-derived pressure and velocity data produced the expected pattern of forward and backward compression and expansion waves. The intra-study reproducibility of the CMR derived wave intensities as a % of the total wave intensity (mean ± standard deviation of differences) was 0.0 ± 6.8%, ICC = 0.91. Intra-study reproducibility for the corresponding invasive data was 0.0 ± 4.4%, ICC = 0.96. The invasive and CMR studies showed reasonable correlation (r = 0.73) with a mean difference of 0.0 ± 11.5%. CONCLUSION: This proof of concept study demonstrated that CMR may be used to perform coronary WIA non-invasively with reasonable reproducibility compared to invasive WIA. The technique potentially allows WIA to be performed in a wider range of patients and pathologies than those who can be studied invasively.


Assuntos
Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Cardiopatias/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Adulto , Aorta/diagnóstico por imagem , Aorta/fisiopatologia , Pressão Arterial , Velocidade do Fluxo Sanguíneo , Suspensão da Respiração , Calibragem , Vasos Coronários/fisiopatologia , Inglaterra , Estudos de Viabilidade , Feminino , Cardiopatias/fisiopatologia , Humanos , Imagem Cinética por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...