Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 13(9)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38731192

RESUMO

Background: Tinnitus-the perception of sound despite the absence of an external source-can be a debilitating condition for which there are currently no pharmacological remedies. Our proof of concept study focused on the immediate effects of non-invasive electrical stimulation through the ear canal on loudness and tinnitus-induced distress. In addition, we aimed to identify variables that may affect the simulation outcomes. Methods: Sixty-six patients (29 women and 37 men, mean age 54.4 ± 10.4) with chronic tinnitus were recruited to the tertiary referral hospital between December 2019 and December 2021. They underwent 10 min of electrical stimulation through the ear canal for three consecutive days. Visual analog scales measured loudness and tinnitus-induced distress immediately before and after stimulation. Results: After three days of electrical stimulation, tinnitus loudness decreased in 47% of patients, 45.5% reported no change, and 7.6% reported worsening. Tinnitus severity decreased in 36.4% of cases, 59.1% of patients reported no change, and 4.5% reported worsening. Women responded positively to therapy earlier than men. In addition, tinnitus distress decreased in patients with compensated tinnitus but not in those with uncompensated tinnitus. Finally, patients with bilateral tinnitus improved earlier than those with unilateral tinnitus, and the age of the patients did not influence the stimulation results. Conclusions: Our proof of concept study confirms the potential of non-invasive electrical stimulation of the ear as a promising screening approach to identifying patients for more advanced electrostimulation treatment, such as an extracochlear anti-tinnitus implant. These findings have practical implications for tinnitus management, offering hope for improved patient care.

2.
HNO ; 71(11): 693-701, 2023 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-37815555

RESUMO

Cochlear implant (CI) treatment is now established as a successful standard of care for auditory rehabilitation of profoundly deaf or severe hearing loss patients. CI candidates with tinnitus also benefit from improved health-related quality of life (HRQoL) and tinnitus burden. Current CI indications include bilateral (double-sided) profound hearing loss and deafness (DSD), unilateral (single-sided) deafness (SSD), and asymmetric hearing loss (AHL). The new and expanded indications for cochlear implants result in different healthcare situations, which may also be associated with differences in tinnitus burden before and after CI treatment. In this article, we discuss the prevalence of tinnitus in different patient groups and the influence of CI on tinnitus prevalence and severity in these groups. In addition, further therapeutic options for tinnitus suppression based on the CI principle are presented, including the development of an anti-tinnitus implant (proof of concept).


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Perda Auditiva Unilateral , Perda Auditiva , Percepção da Fala , Zumbido , Humanos , Zumbido/diagnóstico , Zumbido/reabilitação , Qualidade de Vida , Perda Auditiva Unilateral/reabilitação , Resultado do Tratamento , Perda Auditiva/diagnóstico , Surdez/reabilitação
3.
HNO ; 71(8): 494-503, 2023 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-37436479

RESUMO

BACKGROUND: Patients with single-sided deafness (SSD) and asymmetric hearing loss (AHL) are increasingly being treated with cochlear implants (CI) due to the demonstrated improvements in auditory abilities and quality of life. To date, there are few published studies in which these two groups are comparatively studied. The aim of the current study was to examine which factors differ between those two patient groups, especially preoperatively. METHODS: A secondary analysis of the previously published raw data of 66 prospectively recruited CI patients (21 SSD/45 AHL) was performed. In addition to the hearing outcome, tinnitus distress (tinnitus questionnaire), health-related quality of life (Nijmegen Cochlear Implant Questionnaire, NCIQ), stress (Perceived Stress Questionnaire, PSQ), and psychological comorbidities (General Depression Scale, ADS­L and Generalized Anxiety Disorder scale, GAD-7) were assessed in SSD and AHL patients pre- and postoperatively. RESULTS: Preoperatively, SSD patients showed significantly higher scores in the NCIQ subdomains "elementary" and "advanced sound perception" than the AHL group. Stress (PSQ) and anxiety symptoms (GAD-7) were significantly higher preoperatively in SSD patients than in AHL patients. After CI, these differences were strongly reduced, with minimal differences being detectable between the groups in the investigated domains postoperatively. CONCLUSION: SSD and AHL patients differ significantly preoperatively in terms of their subjective hearing assessment and psychosocial parameters. In SSD patients, psychological stress factors may have a stronger impact on the quality of life than in AHL patients. These aspects should be taken into account in the preoperative counseling and postoperative rehabilitation.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Perda Auditiva Unilateral , Perda Auditiva , Percepção da Fala , Zumbido , Humanos , Zumbido/diagnóstico , Zumbido/cirurgia , Zumbido/psicologia , Qualidade de Vida , Estudos Prospectivos , Perda Auditiva Unilateral/diagnóstico , Perda Auditiva Unilateral/cirurgia , Perda Auditiva Unilateral/reabilitação , Resultado do Tratamento , Surdez/diagnóstico , Surdez/epidemiologia , Surdez/cirurgia
4.
Insights Imaging ; 12(1): 20, 2021 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-33587198

RESUMO

Open injuries bear the risk of foreign body contamination. Commonly encountered materials include gravel debris, glass fragments, wooden splinters or metal particles. While foreign body incorporation is obvious in some injury patterns, other injuries may not display hints of being contaminated with foreign body materials. Foreign objects that have not been detected and removed bear the risk of leading to severe wound infections and chronic wound healing disorders. Besides these severe health issues, medicolegal consequences should be considered. While an accurate clinical examination is the first step for the detection of foreign body materials, choosing the appropriate radiological imaging is decisive for the detection or non-detection of the foreign material. Especially in cases of impaired wound healing over time, the existence of an undetected foreign object needs to be considered.Here, we would like to give a practical radiological guide for the assessment of foreign objects in head and neck injuries by a special selection of patients with different injury patterns and various foreign body materials with regard to the present literature.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...