1.
Nanotechnology ; 30(24): 245203, 2019 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-30780135

RESUMO

In this work we propose multilayer graphene (MLG) nanobelts for high current interconnections with single wall carbon nanotubes (SWCNT) and compare these with metal contacts. MLG contacts were directly printed on the SWCNT, without any additional metal parts, demonstrating the possibility to use these materials as interconnections in microelectronics. Different work function metals Al, Ti and Pd were probed for the lowest contact resistance with the SWCNT. Ti contacts demonstrated the best results among the metals owing to its work function being closest to the SWCNT and therefore giving the lowest Schottky barrier. Even though Ti contacts show the lowest contact resistance, the current density for MLG contacts was higher, giving the best results for high current interconnection applications. Moreover, MLG contacts show a stable and repeatable resistance decrease under high current conditions. Heat treatment of the MLG and metal contacts was completed in vacuum, in order to further reduce the contact resistance and optimal heat treatment conditions were found at 600 °C.

2.
ACS Appl Mater Interfaces ; 9(10): 8880-8890, 2017 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-28225588

RESUMO

In the present work, we have synthesized three-dimensional (3D) reduced graphene oxide nanosheets (rGO NSs) containing iron oxide nanoparticles (Fe3O4 NPs) hybrids (3D Fe3O4/rGO) by one-pot microwave approach. Structural and morphological studies reveal that the as-synthesized Fe3O4/rGO hybrids were composed of faceted Fe3O4 NPs induced into the interconnected network of rGO NSs. The morphologies and structures of the 3D hybrids have been characterized using scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction (XRD), Raman spectroscopy and X-ray photoelectron spectrometer (XPS). The electrochemical studies were analyzed by cyclic voltammetry, galvanostatic charge/discharge measurements, and electrochemical impedance spectroscopy, which demonstrate superior electrochemical performance as supercapacitors electrode application. The specific capacitances of 3D hybrid materials was 455 F g-1 at the scan rate of 8 mV s-1, which is superior to that of bare Fe3O4 NPs. Additionally, the 3D hybrid shows good cycling stability with a retention ratio of 91.4 after starting from ∼190 cycles up to 9600 cycles. These attractive results suggest that this 3D Fe3O4/rGO hybrid shows better performance as an electrode material for high-performance supercapacitors.

4.
Beilstein J Nanotechnol ; 6: 1508-17, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26425404

RESUMO

In this paper we study in detail the post-growth annealing of a copper-containing material deposited with focused electron beam induced deposition (FEBID). The organometallic precursor Cu(II)(hfac)2 was used for deposition and the results were compared to that of compared to earlier experiments with (hfac)Cu(I)(VTMS) and (hfac)Cu(I)(DMB). Transmission electron microscopy revealed the deposition of amorphous material from Cu(II)(hfac)2. In contrast, as-deposited material from (hfac)Cu(I)(VTMS) and (hfac)Cu(I)(DMB) was nano-composite with Cu nanocrystals dispersed in a carbonaceous matrix. After annealing at around 150-200 °C all deposits showed the formation of pure Cu nanocrystals at the outer surface of the initial deposit due to the migration of Cu atoms from the carbonaceous matrix containing the elements carbon, oxygen, and fluorine. Post-irradiation of deposits with 200 keV electrons in a transmission electron microscope favored the formation of Cu nanocrystals within the carbonaceous matrix of freestanding rods and suppressed the formation on their surface. Electrical four-point measurements on FEBID lines from Cu(hfac)2 showed five orders of magnitude improvement in conductivity when being annealed conventionally and by laser-induced heating in the scanning electron microscope chamber.

5.
Sci Rep ; 5: 11546, 2015 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-26100466

RESUMO

Graphene, in single layer or multi-layer forms, holds great promise for future electronics and high-temperature applications. Resistance to oxidation, an important property for high-temperature applications, has not yet been extensively investigated. Controlled thinning of multi-layer graphene (MLG), e.g., by plasma or laser processing is another challenge, since the existing methods produce non-uniform thinning or introduce undesirable defects in the basal plane. We report here that heating to extremely high temperatures (exceeding 2000 K) and controllable layer-by-layer burning (thinning) can be achieved by low-power laser processing of suspended high-quality MLG in air in "cold-wall" reactor configuration. In contrast, localized laser heating of supported samples results in non-uniform graphene burning at much higher rates. Fully atomistic molecular dynamics simulations were also performed to reveal details of oxidation mechanisms leading to uniform layer-by-layer graphene gasification. The extraordinary resistance of MLG to oxidation paves the way to novel high-temperature applications as continuum light source or scaffolding material.

6.
Rev Bras Cir Cardiovasc ; 28(3): 331-7, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24343682

RESUMO

OBJECTIVE: To investigate the influence of the reprocessing technique of enzymatic bath with ultrasonic cleaning and ethylene oxide sterilization on the chemical properties and morphological structure of polymeric coatings of guide wire for regular guiding catheter. METHODS: These techniques simulated the routine of guide wire reprocessing in many hemodynamic services in Brazil and other countries. Samples from three different manufacturers were verified by scanning electron microscopy and X-ray photoelectron spectroscopy. RESULTS: A single or double sterilization of the catheters with ethylene oxide was not associated with morphological or chemical changes. However, scanning electron microscopy images showed that the washing method was associated with rough morphological changes, including superficial holes and bubbles, in addition to chemical changes of external atomic layers of polymeric coating surfaces, as detected by the X-ray photoelectron spectroscopy method, which is compatible with extended chemical changes on catheter surfaces. CONCLUSION: The reprocessing of the catheters with ethylene oxide was not associated with morphological or chemical changes, and it seemed appropriate to maintain guide wire coating integrity. However, the method combining chemical cleaning with mechanical vibration resulted in rough anatomical and chemical surface deterioration, suggesting that this reprocessing method should be discouraged.


Assuntos
Angioplastia/instrumentação , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Esterilização/métodos , Desinfetantes/química , Reutilização de Equipamento , Óxido de Etileno/química , Humanos , Microscopia Eletrônica de Varredura , Polímeros/química , Propriedades de Superfície/efeitos dos fármacos , Propriedades de Superfície/efeitos da radiação , Vibração
7.
Rev. bras. cir. cardiovasc ; 28(3): 331-337, jul.-set. 2013. ilus
Artigo em Inglês | LILACS | ID: lil-697218

RESUMO

OBJECTIVE: To investigate the influence of the reprocessing technique of enzymatic bath with ultrasonic cleaning and ethylene oxide sterilization on the chemical properties and morphological structure of polymeric coatings of guide wire for regular guiding catheter. METHODS: These techniques simulated the routine of guide wire reprocessing in many hemodynamic services in Brazil and other countries. Samples from three different manufacturers were verified by scanning electron microscopy and X-ray photoelectron spectroscopy. RESULTS: A single or double sterilization of the catheters with ethylene oxide was not associated with morphological or chemical changes. However, scanning electron microscopy images showed that the washing method was associated with rough morphological changes, including superficial holes and bubbles, in addition to chemical changes of external atomic layers of polymeric coating surfaces, as detected by the X-ray photoelectron spectroscopy method, which is compatible with extended chemical changes on catheter surfaces. CONCLUSION: The reprocessing of the catheters with ethylene oxide was not associated with morphological or chemical changes, and it seemed appropriate to maintain guide wire coating integrity. However, the method combining chemical cleaning with mechanical vibration resulted in rough anatomical and chemical surface deterioration, suggesting that this reprocessing method should be discouraged.


OBJETIVO: Investigar a influência das técnicas de reprocessamento de banho enzimático com limpeza ultrassônica e a esterilização com óxido de etileno nas propriedades químicas e estruturas morfológicas de revestimentos poliméricos de fios-guia usados como guias em cateteres regulares. MÉTODOS: Estas técnicas simulam a rotina de processamento de fios-guia em muitos serviços de hemodinâmica do Brasil e de outros países. Amostras de três diferentes fabricantes foram verificadas por microscopia eletrônica de varredura e espectroscopia de fotoelétrons de raios-X. RESULTADOS: Uma única ou dupla esterilização dos cateteres com óxido de etileno não foi associada a mudanças químicas ou morfológicas. Contudo, imagens de microscopia eletrônica de varredura mostraram que o método de lavagem foi associado a intensas modificações morfológicas, incluindo bolhas e buracos superficiais, assim como mudanças nas ligações químicas das camadas atômicas externas do revestimento polimérico, conforme demonstrado por resultados de espectroscopia de fotoelétrons de raios-X, compatível com extensas modificações químicas induzidas por esse processo de lavagem. CONCLUSÃO: O reprocessamento dos fios-guia de cateteres com óxido de etileno não está associado a mudanças químicas e morfológicas dos mesmos e pode ser considerado adequado para manter a integridade destes materiais. Entretanto, o método que combina lavagem química com vibração mecânica resulta em intensas deteriorações anatômicas e químicas, sugerindo que esse método de processamento deve ser desencorajado.


Assuntos
Humanos , Angioplastia/instrumentação , Cateteres Cardíacos , Cateterismo Cardíaco/instrumentação , Esterilização/métodos , Desinfetantes/química , Reutilização de Equipamento , Óxido de Etileno/química , Microscopia Eletrônica de Varredura , Polímeros/química , Propriedades de Superfície/efeitos dos fármacos , Propriedades de Superfície/efeitos da radiação , Vibração
8.
Nanotechnology ; 24(15): 155301, 2013 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-23519310

RESUMO

The accuracy of thermal conductivity measurements by the micro-Raman technique for suspended multi-layer graphene flakes has been shown to depend critically on the quality of the thermal contacts between the flakes and the metal electrodes used as the heat sink. The quality of the contacts can be improved by nonlocal laser annealing at increased power. The improvement of the thermal contacts to initially rough metal electrodes is attributed to local melting of the metal surface under laser heating, and increased area of real metal-graphene contact. Improvement of the thermal contacts between multi-layer graphene and a silicon oxide surface was also observed, with more efficient heat transfer from graphene as compared with the graphene-metal case.