Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Lab Physicians ; 14(1): 43-46, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36186258

RESUMO

Introduction Urea secreted in the sweat is important for skin moisture. Similarly, ocular surface moisture is maintained by the conjunctiva. Based on this, the level of urea in tear film can be used as a potential diagnostic test for dry eye disease (DED). One of the standard tests for DED is Schirmer's test (ST). The aim of this study was to compare tear film urea to values of ST. Methods Fifty patients symptomatic for DED having ST ≤ 10 mm/5 min were enrolled in the study. Fifty age- and sex-matched asymptomatic subjects with ST > 10 mm/5 min were taken as controls. All patients were subjected to an estimation of tear film urea, collected using micropipettes, and analyzed by an Erba Chem 5 semi-autoanalyzer. Based on the ST reading as per the Dry Eye Workshop 2007 (DEWS) classification, dry eye was classified as dry eye (≤ 10 mm/5 min), severe dry eye (≤ 5 mm/5 min), and very severe dry eye (≤ 2 mm/5 min). Tear film urea values were compared with ST values that were considered standard. Statistical analysis was done using Medcalc version 19.7. A p -value ≤ 0.05 was considered significant. Results The mean tear film urea levels in cases were (26.78 ± 5.70 mg/dL) significantly lower compared with controls (41.72 ± 6.86 mg/dL). The area under the receiver characteristic operator curve (AUC) for tear film urea in diagnosing DED was 0.936 ( p < 0.0001) with a cutoff of ≤ 37.2 mg/dL, yielding a sensitivity of 96% and a specificity of 76%. For diagnosing severe DED, the AUC for tear film urea was 0.824 ( p < 0.0001) with a cutoff value of ≤ 23.4 mg/dL, yielding a sensitivity of 60.8% and a specificity of 92.59%. For diagnosis of very severe DED, the AUC for tear film urea was 0.972 ( p < 0.0001) with a cutoff value of ≤ 19.8 mg/dL, yielding a sensitivity of 100% and a specificity of 93.62%. On comparing ST values to tear film urea, the regression coefficient was 0.85 ( p < 0.0001), suggesting a linear relationship between ST and tear film urea. Conclusion The study demonstrates that tear film urea can be a potential diagnostic marker for DED. The study also indicates that tear film urea level is linearly related to Schirmer's test values and provides an approximate diagnostic cutoff level for the design of future large-scale studies.

2.
Cureus ; 14(1): e21692, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35237485

RESUMO

Central venous port catheters (CVPCs) are commonly employed for long-term chemotherapy. One of the rare complications associated with CVPCs is catheter fracture and further embolization of the fragmented segment into the heart. The most common site of embolization is the superior vena cava-right atrium (RA) junction. However, infrequently, the catheter may embolize further distally into the right ventricle (RV) and beyond making the fragmented tips difficult to access directly with a snare. Here, we report a case wherein both the catheter tips were lodged in the RV cavity forming a loop in the RA. This necessitated the use of a modified technique to retrieve the fragment percutaneously.

3.
Cureus ; 13(11): e19350, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34909311

RESUMO

An unroofed coronary sinus is an uncommon congenital cardiac anomaly. It leads to a left to right shunt like an atrial septal defect (ASD) and comprises <1% of all ASDs. It can also additionally create a pathway for paradoxical embolization to the brain and other attendant complications. Here, we present the case of an asymptomatic 40-year-old-male with a history of prior surgical closure of an ostium secundum ASD who was referred for preoperative evaluation for non-cardiac surgery. An unroofed coronary sinus with persistent left superior vena cava (PLSVC) was suspected on transthoracic echocardiography and confirmed by transesophageal echocardiography.

4.
Cureus ; 13(5): e15286, 2021 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-34221751

RESUMO

Takayasu's arteritis (TA) is a large-vessel chronic inflammatory vasculitis that leads to thrombotic vascular occlusion. This can lead to varied presentations including limb claudication, ischemic stroke, hypertension, and heart failure. Although contrast computed tomography angiography is the main modality for imaging of the aorta and its branches, transthoracic echocardiography can be an easy-to-access, point-of-care, initial screening tool for evaluating the aorta and other cardiac structures. We present echocardiographic images from two cases that demonstrate the important cardiac structural and vascular afflictions of TA.

5.
Cureus ; 13(4): e14450, 2021 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-34017650

RESUMO

Tricuspid atresia (TA) is a rare cyanotic congenital heart disease. A persistent left superior vena cava (LSVC) may be associated with TA. The presence of LSVC raises important considerations for eventual repair, in that it may lead to persistent arterial desaturation even after corrective surgery, if associated with an unroofed coronary sinus. Here, we present the case of a four-month-old child who was diagnosed with TA type 1B, LSVC and a dilated coronary sinus by transthoracic echocardiography.

6.
Cureus ; 13(3): e13800, 2021 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-33842172

RESUMO

Introduction The 60/60 sign in 2D transthoracic echocardiography (TTE) - a combination of pulmonary acceleration time (PAT) less than 60 milliseconds and tricuspid regurgitation (TR) jet gradient of less than 60 mmHg - has been found to be specific for the diagnosis of pulmonary embolism (PE). Materials and methods An observational prospective analysis was carried out on cases of suspected PE presenting to the emergency room (ER). TTE was performed on all cases with suspected PE prior to computed tomography pulmonary angiography (CTPA). Emphasis was placed on measurement of PAT and early systolic notching (ESN) on the pulsed wave (PW) Doppler of the pulmonary valve, TR jet gradient, right ventricle systolic excursion velocity (RV S') by tissue doppler imaging (TDI), tricuspid annular plane systolic excursion (TAPSE), and right ventricle to left ventricle end-diastolic dimension ratio (RV:LV EDD) in modified parasternal short-axis view. These signs were taken as screening tests and compared to CTPA as the standard test. Patients were followed up until hospital discharge or death. Observations Fifty-six cases of suspected PE were enrolled for the study. Of these, 24 cases of PE were confirmed by CTPA. Out of 24 cases of PE, 15 were high-risk PE, six were intermediate high-risk PE, and three were intermediate low-risk PE. The mean age was 53.07±9.79 years with a male-to-female ratio of 1.95:1. The 60/60 sign was present in 70.83% of cases of PE. RV:LV EDD in a modified short-axis view of more than 0.9 was present in 91.67% of cases of PE, and ESN on the PW Doppler of the pulmonary valve was present in 75% of cases of PE. The 60/60 sign, RV:LV EDD ratio more than 0.9, and ESN showed sensitivities of 70.83%, 91.67%, 75%, and specificities of 93.75%, 75%, and 100%, respectively for PE. For prediction of mortality, presence of the 60/60 sign (Odds Ratio=8.13, p-value=0.034) and ESN (Odds Ratio=17.50, p-value=0.02) were statistically significant. Conclusions 60/60 sign and ESN are specific for the diagnosis of PE but have poor sensitivity.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA