Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nanomedicine (Lond) ; 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38722243

RESUMO

Aim: To investigate whether medical devices coated with a synthesized nanocomposite of poly(methylmethacrylate-co-dimethyl acrylamide) (PMMDMA) and silver nanoparticles (AgNPs) could improve their antibiofilm and antimicrobial activities. We also investigated the nanocomposite's safety. Materials & methods: The nanocomposite was synthesized and characterized using analytical techniques. Medical devices coated with the nanocomposite were evaluated for bacterial adhesion and hemolytic activity in vitro. Results: The nanocomposite formation was demonstrated with the incorporation of AgNPs into the polymer matrix. The nanocomposite proved to be nonhemolytic and significantly inhibited bacterial biofilm formation. Conclusion: The PMMDMA-AgNPs nanocomposite was more effective in preventing biofilm formation than PMMDMA alone and is a promising strategy for coating medical devices and reducing mortality due to hospital-acquired infections.

2.
J Biomed Opt ; 28(12): 126007, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-38155703

RESUMO

Significance: Rapid advances in medical imaging technology, particularly the development of optical systems with non-linear imaging modalities, are boosting deep tissue imaging. The development of reliable standards and phantoms is critical for validation and optimization of these cutting-edge imaging techniques. Aim: We aim to design and fabricate flexible, multi-layered hydrogel-based optical standards and evaluate advanced optical imaging techniques at depth. Approach: Standards were made using a robust double-network hydrogel matrix consisting of agarose and polyacrylamide. The materials generated ranged from single layers to more complex constructs consisting of up to seven layers, with modality-specific markers embedded between the layers. Results: These standards proved useful in the determination of the axial scaling factor for light microscopy and allowed for depth evaluation for different imaging modalities (conventional one-photon excitation fluorescence imaging, two-photon excitation fluorescence imaging, second harmonic generation imaging, and coherent anti-Stokes Raman scattering) achieving actual depths of 1550, 1550, 1240, and 1240 µm, respectively. Once fabricated, the phantoms were found to be stable for many months. Conclusions: The ability to image at depth, the phantom's robustness and flexible layered structure, and the ready incorporation of "optical markers" make these ideal depth standards for the validation of a variety of imaging modalities.


Assuntos
Hidrogéis , Dispositivos Ópticos , Imagens de Fantasmas , Microscopia/métodos , Imagem Óptica
3.
Inflamm Regen ; 43(1): 46, 2023 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-37759310

RESUMO

BACKGROUND: Pancreatic adenocarcinoma (PAAD) is one of the most fatal human cancers, but effective therapies remain to be established. Cancer stem cells (CSCs) are highly resistant to anti-cancer drugs and a deeper understanding of their microenvironmental niche has been considered important to provide understanding and solutions to cancer eradication. However, as the CSC niche is composed of a wide variety of biological and physicochemical factors, the development of multidisciplinary tools that recapitulate their complex features is indispensable. Synthetic polymers have been studied as attractive biomaterials due to their tunable biofunctionalities, while hydrogelation technique further renders upon them a diversity of physical properties, making them an attractive tool for analysis of the CSC niche. METHODS: To develop innovative materials that recapitulate the CSC niche in pancreatic cancers, we performed polymer microarray analysis to identify niche-mimicking scaffolds that preferentially supported the growth of CSCs. The niche-mimicking activity of the identified polymers was further optimized by polyethylene glycol (PEG)-based hydrogelation. To reveal the biological mechanisms behind the activity of the optimized hydrogels towards CSCs, proteins binding onto the hydrogel were analyzed by liquid chromatography with tandem mass spectrometry (LC-MS/MS), and the potential therapeutic targets were validated by looking at gene expression and patients' outcome in the TCGA database. RESULTS: PA531, a heteropolymer composed of 2-methoxyethyl methacrylate (MEMA) and 2-(diethylamino)ethyl methacrylate (DEAEMA) (5.5:4.5) that specifically supports the growth and maintenance of CSCs was identified by polymer microarray screening using the human PAAD cell line KLM1. The polymer PA531 was converted into five hydrogels (PA531-HG1 to HG5) and developed to give an optimized scaffold with the highest CSC niche-mimicking activities. From this polymer that recapitulated CSC binding and control, the proteins fetuin-B and angiotensinogen were identified as candidate target molecules with clinical significance due to the correlation between gene expression levels and prognosis in PAAD patients and the proteins associated with the niche-mimicking polymer. CONCLUSION: This study screened for biofunctional polymers suitable for recapitulation of the pancreatic CSC niche and one hydrogel with high niche-mimicking abilities was successfully fabricated. Two soluble factors with clinical significance were identified as potential candidates for biomarkers and therapeutic targets in pancreatic cancers. Such a biomaterial-based approach could be a new platform in drug discovery and therapy development against CSCs, via targeting of their niche.

4.
Eur J Immunol ; 53(3): e2249934, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36645212

RESUMO

Thymic epithelial cells (TECs) are key effectors of the thymic stroma and are critically required for T-cell development. TECs comprise a diverse set of related but functionally distinct cell types that are scarce and difficult to isolate and handle. This has precluded TEC-based screening assays. We previously described induced thymic epithelial cells (iTECs), an artificial cell type produced in vitro by direct reprogramming, raising the possibility that iTECs might provide the basis for functional screens related to TEC biology. Here, we present an iTEC-based three-stage medium/high-throughput in vitro assay for synthetic polymer mimics of thymic extracellular matrix (ECM). Using this assay, we identified, from a complex library, four polymers that bind iTEC as well as or better than gelatin but do not bind mesenchymal cells. We show that these four polymers also bind and maintain native mouse fetal TECs and native human fetal TECs. Finally, we show that the selected polymers do not interfere with iTEC function or T-cell development. Collectively, our data establish that iTECs can be used to screen for TEC-relevant compounds in at least some medium/high-throughput assays and identify synthetic polymer ECM mimics that can replace gelatin or ECM components in TEC culture protocols.


Assuntos
Gelatina , Timo , Camundongos , Humanos , Animais , Gelatina/metabolismo , Células Epiteliais/metabolismo , Diferenciação Celular , Matriz Extracelular
5.
Stem Cell Reports ; 17(5): 1215-1228, 2022 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-35452596

RESUMO

With the aim of producing ß cells for replacement therapies to treat diabetes, several protocols have been developed to differentiate human pluripotent stem cells to ß cells via pancreatic progenitors. While in vivo pancreatic progenitors expand throughout development, the in vitro protocols have been designed to make these cells progress as fast as possible to ß cells. Here, we report on a protocol enabling a long-term expansion of human pancreatic progenitors in a defined medium on fibronectin, in the absence of feeder layers. Moreover, through a screening of a polymer library we identify a polymer that can replace fibronectin. Our experiments, comparing expanded progenitors to directly differentiated progenitors, show that the expanded progenitors differentiate more efficiently into glucose-responsive ß cells and produce fewer glucagon-expressing cells. The ability to expand progenitors under defined conditions and cryopreserve them will provide flexibility in research and therapeutic production.


Assuntos
Células Secretoras de Insulina , Células-Tronco Pluripotentes , Diferenciação Celular , Fibronectinas/farmacologia , Humanos , Pâncreas , Polímeros
6.
Anal Chim Acta ; 1134: 136-143, 2020 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-33059859

RESUMO

Technologies for measuring physiological parameters in vivo offer the possibility of the detection of disease and its progression due to the resulting changes in tissue pH, or temperature, etc.. Here, a compact hydrogel-based optical fibre pH sensor was fabricated, in which polymer microarrays were utilized for the high-throughput discovery of an optimal matrix for pH indicator immobilization. The fabricated hydrogel-based probe responded rapidly to pH changes and demonstrated a good linear correlation within the physiological pH range (from 5.5 to 8.0) with a precision of 0.10 pH units. This miniature probe was validated by measuring pH across a whole ovine lung and allowed discrimination of tumorous and normal tissue, thus offering the potential for the rapid and accurate observation of tissue pH changes.


Assuntos
Neoplasias Pulmonares , Fibras Ópticas , Animais , Hidrogéis , Concentração de Íons de Hidrogênio , Pulmão , Ovinos
7.
Cells ; 9(10)2020 09 24.
Artigo em Inglês | MEDLINE | ID: mdl-32987746

RESUMO

Tuberculosis (TB) caused by Mycobacterium tuberculosis is one of the most lethal infectious diseases with estimates of approximately 1.4 million human deaths in 2018. M. tuberculosis has a well-established ability to circumvent the host immune system to ensure its intracellular survival and persistence in the host. Mechanisms include subversion of expression of key microRNAs (miRNAs) involved in the regulation of host innate and adaptive immune response against M. tuberculosis. Several studies have reported differential expression of miRNAs during active TB and latent tuberculosis infection (LTBI), suggesting their potential use as biomarkers of disease progression and response to anti-TB therapy. This review focused on the miRNAs involved in TB pathogenesis and on the mechanism through which miRNAs induced during TB modulate cell antimicrobial responses. An attentive study of the recent literature identifies a group of miRNAs, which are differentially expressed in active TB vs. LTBI or vs. treated TB and can be proposed as candidate biomarkers.


Assuntos
Biomarcadores/metabolismo , MicroRNAs/genética , Tuberculose/genética , Animais , Autofagia/genética , Progressão da Doença , Humanos , Inflamação/genética , Inflamação/patologia , MicroRNAs/metabolismo , Tuberculose/imunologia
8.
Adv Healthc Mater ; 9(4): e1901347, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31943855

RESUMO

Substrates for neuron culture and implantation are required to be both biocompatible and display surface compositions that support cell attachment, growth, differentiation, and neural activity. Laminin, a naturally occurring extracellular matrix protein is the most widely used substrate for neuron culture and fulfills some of these requirements, however, it is expensive, unstable (compared to synthetic materials), and prone to batch-to-batch variation. This study uses a high-throughput polymer screening approach to identify synthetic polymers that supports the in vitro culture of primary mouse cerebellar neurons. This allows the identification of materials that enable primary cell attachment with high viability even under "serum-free" conditions, with materials that support both primary cells and neural progenitor cell attachment with high levels of neuronal biomarker expression, while promoting progenitor cell maturation to neurons.


Assuntos
Células-Tronco Neurais , Neurônios , Animais , Diferenciação Celular , Células Cultivadas , Laminina , Camundongos , Polímeros
9.
ACS Comb Sci ; 21(5): 417-424, 2019 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-30973701

RESUMO

Polymer microarrays were utilized for the high-throughput screening and discovery of optimal polymeric substrates capable of trapping functional ratiometric fluorescence-based pH sensors. This led to the identification of poly(methyl methacrylate- co-2-(dimethylamino) ethyl acrylate) (PA101), which allowed, via dip coating, the attachment of fluorescent pH sensors onto the tips of optical fibers, resulting in robust, rapid, and reproducible sensing of physiological pHs.


Assuntos
Fibras Ópticas , Polimetil Metacrilato/química , Complexos de Coordenação/química , Fluoresceínas/química , Corantes Fluorescentes/química , Ensaios de Triagem em Larga Escala , Análise em Microsséries , Paládio/química , Espectrometria de Fluorescência
10.
Acta Biomater ; 90: 146-156, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30910621

RESUMO

Cartilage degeneration or damage treatment is still a challenge, but, tissue engineering strategies, which combine cell therapy strategies, which combine cell therapy and scaffolds, and have emerged as a promising new approach. In this regard, polyurethanes and polyacrylates polymers have been shown to have clinical potential to treat osteochondral injuries. Here, we have used polymer microarrays technology to screen 380 different polyurethanes and polyacrylates polymers. The top polymers with potential to maintain chondrocyte viability were selected, with scale-up studies performed to evaluate their ability to support chondrocyte proliferation during long-term culture, while maintaining their characteristic phenotype. Among the selected polymers, poly (methylmethacrylate-co-methacrylic acid), showed the highest level of chondrogenic potential and was used to create a 3D hydrogel. Ultrastructural morphology, microstructure and mechanical testing of this novel hydrogel revealed robust characteristics to support chondrocyte growth. Furthermore, in vitro and in vivo biological assays demonstrated that chondrocytes cultured on the hydrogel had the capacity to produce extracellular matrix similar to hyaline cartilage, as shown by increased expression of collagen type II, aggrecan and Sox9, and the reduced expression of the fibrotic marker's collagen type I. In conclusion, hydrogels generated from poly (methylmethacrylate-co-methacrylic acid) created the appropriate niche for chondrocyte growth and phenotype maintenance and might be an optimal candidate for cartilage tissue-engineering applications. SIGNIFICANCE STATEMENT: Articular cartilage has limited self-repair ability due to its avascular nature, therefore tissue engineering strategies have emerged as a promising new approach. Synthetic polymers displaygreat potential and are widely used in the clinical setting. In our study, using the polymer microarray technique a novel type of synthetic polyacrylate was identified, that was converted into hydrogels for articular cartilage regeneration studies. The hydrogel based on poly (methylmethacrylate-co-methacrylic acid-co-PEG-diacrylate) had a controlable ultrastructural morphology, microstructure (porosity) and mechanical properties (stiffness) appropriate for cartilage engineering. Our hydrogel created the optimal niche for chondrocyte growth and phenotype maintenance for long-term culture, producing a hyaline-like cartilage extracellular matrix. We propose that this novel polyacrylate hydrogel could be an appropriate support to help in the treatment efficient cartilage regeneration.


Assuntos
Resinas Acrílicas/química , Cartilagem Articular/metabolismo , Condrócitos/metabolismo , Matriz Extracelular/química , Hidrogéis/química , Engenharia Tecidual , Alicerces Teciduais/química , Animais , Humanos , Camundongos , Camundongos Endogâmicos NOD , Camundongos SCID
11.
Biomater Sci ; 6(1): 154-167, 2017 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-29148548

RESUMO

Calcific aortic valve disease (CAVD) is the most frequent cardiac valve pathology. Its standard treatment consists of surgical replacement either with mechanical (metal made) or biological (animal tissue made) valve prostheses, both of which have glaring deficiencies. In the search for novel materials to manufacture artificial valve tissue, we have conducted a high-throughput screening with subsequent up-scaling to identify non-degradable polymer substrates that promote valve interstitial cells (VICs) adherence/growth and, at the same time, prevent their evolution toward a pro-calcific phenotype. Here, we provide evidence that one of the two identified 'hit' polymers, poly(methoxyethylmethacrylate-co-diethylaminoethylmethacrylate), provided robust VICs adhesion and maintained the healthy VICs phenotype without inducing pro-osteogenic differentiation. This ability was also maintained when the polymer was used to coat a non-woven poly-caprolactone (PCL) scaffold using a novel solvent coating procedure, followed by bioreactor-assisted VICs seeding. Since we observed that VICs had an increased secretion of the elastin-maturing component MFAP4 in addition to other valve-specific extracellular matrix components, we conclude that valve implants constructed with this polyacrylate will drive the biological response of human valve-specific cells.


Assuntos
Engenharia Tecidual/métodos , Animais , Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide , Diferenciação Celular/fisiologia , Proliferação de Células/fisiologia , Células Cultivadas , Matriz Extracelular/química , Cardiopatias Congênitas/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Humanos , Poliésteres/química
12.
Sci Rep ; 7(1): 407, 2017 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-28341826

RESUMO

Decellularized vascular scaffolds are promising materials for vessel replacements. However, despite the natural origin of decellularized vessels, issues such as biomechanical incompatibility, immunogenicity risks and the hazards of thrombus formation, still need to be addressed. In this study, we coated decellularized vessels obtained from porcine carotid arteries with poly (ethylmethacrylate-co-diethylaminoethylacrylate) (8g7) with the purpose of improving endothelial coverage and minimizing platelet attachment while enhancing the mechanical properties of the decellularized vascular scaffolds. The polymer facilitated binding of endothelial cells (ECs) with high affinity and also induced endothelial cell capillary tube formation. In addition, platelets showed reduced adhesion on the polymer under flow conditions. Moreover, the coating of the decellularized arteries improved biomechanical properties by increasing its tensile strength and load. In addition, after 5 days in culture, ECs seeded on the luminal surface of 8g7-coated decellularized arteries showed good regeneration of the endothelium. Overall, this study shows that polymer coating of decellularized vessels provides a new strategy to improve re-endothelialization of vascular grafts, maintaining or enhancing mechanical properties while reducing the risk of thrombogenesis. These results could have potential applications in improving tissue-engineered vascular grafts for cardiovascular therapies with small caliber vessels.


Assuntos
Artérias Carótidas/fisiologia , Trombose das Artérias Carótidas/prevenção & controle , Células Endoteliais/fisiologia , Metilmetacrilatos/química , Engenharia Tecidual/métodos , Alicerces Teciduais/química , Animais , Materiais Biocompatíveis/química , Biopolímeros , Plaquetas/fisiologia , Prótese Vascular , Artérias Carótidas/ultraestrutura , Endotélio Vascular/fisiologia , Células Endoteliais da Veia Umbilical Humana/fisiologia , Humanos , Suínos
13.
J Vis Exp ; (117)2016 11 05.
Artigo em Inglês | MEDLINE | ID: mdl-27842360

RESUMO

Medical devices are often associated with hospital-acquired infections, which place enormous strain on patients and the healthcare system as well as contributing to antimicrobial resistance. One possible avenue for the reduction of device-associated infections is the identification of bacteria-repellent polymer coatings for these devices, which would prevent bacterial binding at the initial attachment step. A method for the identification of such repellent polymers, based on the parallel screening of hundreds of polymers using a microarray, is described here. This high-throughput method resulted in the identification of a range of promising polymers that resisted binding of various clinically relevant bacterial species individually and also as multi-species communities. One polymer, PA13 (poly(methylmethacrylate-co-dimethylacrylamide)), demonstrated significant reduction in attachment of a number of hospital isolates when coated onto two commercially available central venous catheters. The method described could be applied to identify polymers for a wide range of applications in which modification of bacterial attachment is important.


Assuntos
Bactérias , Contaminação de Equipamentos , Equipamentos e Provisões , Polímeros , Aderência Bacteriana
14.
J Mater Chem B ; 4(32): 5405-5411, 2016 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-27746915

RESUMO

Infections arising from contaminated medical devices are a serious global issue, contributing to antibiotic resistance and imposing significant strain on healthcare systems. Since the majority of medical device-associated infections are biofilm related, efforts are being made to generate either bacteria-repellent or antibacterial coatings aimed at preventing bacterial colonisation. Here, we utilise a nanocapsule mediated slow release of a natural antimicrobial to improve the performance of a bacteria repellent polymer coating. Poly(lauryl acrylate) nanocapsules containing eugenol (4-allyl-2-methoxyphenol) were prepared and entrapped within a interpenetrating network designed to repel bacteria. When coated on a catheter and an endotracheal tube, this hemocompatible system allowed slow-release of eugenol, resulting in notable reduction in surface-bound Klebsiella pneumoniae and methicillin resistant Staphylococcus aureus.

15.
Talanta ; 161: 489-496, 2016 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-27769437

RESUMO

Over the last decade, circulating microRNAs have received attention as diagnostic and prognostic biomarkers. In particular, microRNA122 has been demonstrated to be an early and more sensitive indicator of drug-induced liver injury than the widely used biomarkers such as alanine aminotransferase and aspartate aminotransferase. Recently, microRNA122 has been used in vitro to assess the cellular toxicity of new drugs and as a biomarker for the development of a rapid test for drug overdose/liver damage. In this proof-of-concept study, we report a PCR-free and label-free detection method that has a limit of detection (3 standard deviations) of 15 fmoles of microRNA122, by integrating a dynamic chemical approach for "Single Nucleobase Labelling" with a bead-based platform (Luminex®) thereby, in principle, demonstrating the exciting prospect of rapid and accurate profiling of any microRNAs related to diseases and toxicology.


Assuntos
MicroRNAs/análise , Biomarcadores , Limite de Detecção , Microesferas , Sondas de Ácido Nucleico , Ácidos Nucleicos Peptídicos
16.
J Mater Chem B ; 2(39): 6723-6729, 2014 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-25580245

RESUMO

Nosocomial infections due to bacteria have serious implications on the health and recovery of patients in a variety of medical scenarios. Since bacterial contamination on medical devices contributes to the majority of nosocomical infections, there is a need for redesigning the surfaces of medical devices, such as catheters and tracheal tubes, to resist the binding of bacteria. In this work, polyurethanes and polyacrylates/acrylamides, which resist binding by the major bacterial pathogens underpinning implant-associated infections, were identified using high-throughput polymer microarrays. Subsequently, two 'hit' polymers, PA13 (poly(methylmethacrylate-co-dimethylacrylamide)) and PA515 (poly(methoxyethylmethacrylate-co-diethylaminoethylacrylate-co-methylmethacrylate)), were used to coat catheters and substantially shown to decrease binding of a variety of bacteria (including isolates from infected endotracheal tubes and heart valves from intensive care unit patients). Catheters coated with polymer PA13 showed up to 96% reduction in bacteria binding in comparison to uncoated catheters.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...