Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Curr Heart Fail Rep ; 20(1): 12-23, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36701019

RESUMO

PURPOSE OF REVIEW: This review offers an overview of the evidence in diagnostic and therapeutic applications of remote monitoring implantable devices. RECENT FINDINGS: Remote monitoring of cardiac implantable devices has become more and more popular in recent years as healthcare is moving towards a more patient centralized system. For heart failure patients with an ICD or pacemaker, there is controversial evidence regarding improvements in the clinical outcome, e.g., reduction of hospitalization rates or overall mortality. New developments as hemodynamic remote monitoring via measurement of the pulmonary artery pressure are promising technical achievements showing encouraging results. In cardiac remote monitoring of syncope and arrhythmias, implantable loop recorder plays an important role in diagnostic algorithms. Although there is controversial evidence according to remote monitoring of implantable devices, its use is rapidly expanding, giving healthcare providers the opportunity to react promptly to worsening of their patients. Adequate evaluation of the data created by remote monitoring systems remains an unsolved challenge of contemporary healthcare services.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Marca-Passo Artificial , Humanos , Insuficiência Cardíaca/terapia , Arritmias Cardíacas/terapia , Eletrocardiografia/métodos
2.
J Electrocardiol ; 53: 100-108, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30739055

RESUMO

AIMS: Remote monitoring by implantable devices substantially improves management of heart failure (HF) patients by providing diagnostic day-to-day data. The use of thoracic impedance (TI) as a surrogate measure of fluid accumulation is still strongly debated. The multicenter HomeCARE-II study evaluated clinically apparent HF events in the context of remote device diagnostics, focusing on the controversial role of TI. METHODS AND RESULTS: We followed 497 patients (66.6 ±â€¯10.1 years, 77% male, QRS 139.8 ±â€¯36.0 ms, ejection fraction 26.8 ±â€¯7.0%) implanted with a CRT-D (67%) or an ICD (33%) for 21.4 ±â€¯8.1 months. An independent event committee confirmed 171 HF events of which 82 were used to develop a TI-based algorithm for the prediction of imminent cardiac decompensation. Highly inter-individual variations in patterns of TI trends were observed. The algorithm resulted in a sensitivity of 41.5% (50.0%) with 0.95 (1.34) false alerts per patient year, and a positive predictive value of 7.9% overall and 27.9% in the HF event group of patients. Averaged ratio statistics showed a significant pre-hospital decrease and a highly significant in-hospital increase in TI after intensified diuresis. Recurrent decompensations turned out to be preceded by a significantly stronger decrease of TI compared to first events with a higher chance for detection (63.6% sensitivity, p < 0.05). CONCLUSIONS: Overall performance in predicting imminent decompensation by monitoring TI alone is limited due to its high inter-patient variability. TI stand-alone applications should be redirected towards a target population with more advanced symptoms where post-hospital observation aimed to maintain the patient's discharge status might be the most valuable approach. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier NCT00711360 (HomeCARE-II) and NCT01221649 (J-HomeCARE-II).


Assuntos
Cardiografia de Impedância/instrumentação , Insuficiência Cardíaca/fisiopatologia , Idoso , Algoritmos , Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Impedância Elétrica , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Humanos , Masculino , Estudos Prospectivos , Sensibilidade e Especificidade , Volume Sistólico
3.
Europace ; 21(6): 961-969, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30809649

RESUMO

AIMS: Non-compaction cardiomyopathy (NCCM) is associated with high rates of mortality and morbidity. Knowledge regarding risk stratification, arrhythmogenesis, therapy, and prognosis is limited. The aim of this study was to analyse the outcome of patients suffering from NCCM and ventricular arrhythmias (VAs) focusing on a treatment with implantable cardioverter-defibrillator (ICD) therapy and catheter ablation. METHODS AND RESULTS: We conducted a multicentre observational study on 18 patients with NCCM, who underwent ICD implantation for secondary (n = 12) and primary (n = 6) prevention. In patients with multiple symptomatic episodes of VAs catheter ablation was performed. During a follow-up of 62 ± 42 months, 12 patients (67%) presented with appropriate ICD therapies [ventricular tachycardia (VT): n = 8; ventricular fibrillation (VF): n = 4; VT/VF: n = 3]. Ten patients underwent catheter ablation for VT/VF. Solely endocardial ablation was conducted in eight patients, and in two patients endo- and epicardial ablation was performed within the same procedure. Acute procedural success was achieved in 9/10 patients. Ventricular tachycardia recurrence was observed in two patients and the median arrhythmia free interval was 9.5 months (interquartile range 5.3-21 months). One patient underwent reablation, four patients died due to the underlying NCCM, and one patient received a left ventricular assist device. CONCLUSION: Ventricular arrhythmias are common in patients suffering from NCCM and ICD therapy may be effective for primary and secondary prevention. In our cohort, consisting of patients with multiple VA episodes and recurrent ICD therapy, catheter ablation offered a safe and effective therapeutically option.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Cardiopatias Congênitas/complicações , Taquicardia Ventricular/prevenção & controle , Adulto , Idoso , Mapeamento Epicárdico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
4.
JACC Clin Electrophysiol ; 4(6): 733-743, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29929666

RESUMO

OBJECTIVES: This study aimed to evaluate the impact, safety, and success of atrial fibrillation (AF) ablation in adults with congenital heart disease (ACHD) transferring ablation strategies established in normal hearts. BACKGROUND: AF is an emerging arrhythmia in ACHD. METHODS: Fifty-seven consecutive ACHD (median age 51.1 ± 14.8 years) with drug-refractory AF were analyzed who underwent catheter ablation between 2004 and 2017. CHD was classified according to its complexity into mild (61.4%), moderate (17.5%), and severe (21.1%) lesions. AF ablation was performed in 104 procedures following a sequential ablation approach. RESULTS: Of the 57 patients, 30 underwent corrective surgery, 6 underwent palliative surgery, 5 had catheter interventions, and 16 were natural survivors. Follow-up was available for all patients (median 41 ± 36 months). The median duration of cyanosis was 9.2 ± 19.7 years, and the time of volume or pressure overload prior to corrective surgery or intervention was 26.1 ± 21.2 years and 18.1 ± 15.8 years, respectively. The Kaplan-Meier estimate for arrhythmia-free survival following the index ablation procedure was 63% for 1 year and 22% for 5 years. Performing subsequent ablation procedures (2.0 ± 0.5), the Kaplan-Meier estimate significantly improved, with 99% for 1 year and 83% for 5 years (p < 0.01). Five patients died during follow-up due to their underlying CHD condition or underwent transplantation. CONCLUSIONS: AF ablation strategies established in normal hearts can be transferred to ACHD. The treatment is safe and effective with acceptable long-term results. Varying anatomical pre-conditions and the heterogeneous population itself are challenging and contribute toward a higher reablation rate. Therefore, AF ablation in ACHD should be reserved for dedicated and highly specialized teams.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Cardiopatias Congênitas/complicações , Adulto , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Ablação por Cateter/mortalidade , Intervalo Livre de Doença , Seguimentos , Humanos , Pessoa de Meia-Idade
5.
Herzschrittmacherther Elektrophysiol ; 29(3): 246-253, 2018 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-29946890

RESUMO

With the rapid development of new mapping and imaging technologies as well as catheter ablation technologies, it is increasingly important to understand the basic concepts of conventional mapping and ablation of cardiac arrhythmias. Prerequisite for successful ablation is the exact identification of the tachycardia mechanism and subsequent localization of the origin or tachycardic substrate. Only intracardiac electrograms provide decisive information regarding activation time and signal morphology. In some arrhythmias, it is necessary to supplement conventional mapping with so-called pace and/or entrainment mapping. This article aims to discuss and demonstrate the fundamentals of intracardiac mapping as it relates to the mapping and ablation of supraventricular and ventricular arrhythmias based on representative clinical cases. Modern three-dimensional mapping methods make it possible to individually optimize established ablation strategies with significantly better spatial resolution. The authors aimed to demonstrate that intracardiac uni- and bipolar electrograms provide essential information about timing and morphology guiding successful catheter ablation. Furthermore, our article provides useful information about conventional cardiac mapping techniques including activation mapping, pace mapping, and individual substrate mapping.


Assuntos
Arritmias Cardíacas , Mapeamento Potencial de Superfície Corporal , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Humanos , Taquicardia Ventricular
6.
Artigo em Inglês | MEDLINE | ID: mdl-28292751

RESUMO

BACKGROUND: The implantable cardioverter-defibrillator (ICD) is the standard therapy to prevent sudden cardiac death in patients with coronary artery disease and unstable ventricular tachyarrhythmias. The prospective multinational SMS (Substrate Modification Study) was designed to assess whether prophylactic ablation of the arrhythmogenic substrate reduces or prevents the recurrence of ventricular tachycardia/ventricular fibrillation in such patients. METHODS AND RESULTS: Of 111 patients included in an intention-to-treat analysis, 54 were randomly assigned catheter ablation plus ICD implantation (ablation group: 68±8 years; 47 men), whereas 57 were assigned ICD implantation without catheter ablation (ICD-only group: 66±8 years; 46 men). Primary study end point was the time to first recurrence of ventricular tachycardia/ventricular fibrillation. ICD episodes were assessed and verified by an independent board. Patients were followed up for 2.3±1.1 years. The primary end point was reached by 25 ablation patients and 26 ICD-only patients. Two-year event-free survival was estimated at 49.0% (95% confidence interval, 33.3%-62.9%) in the former and 52.4% (36.7%-65.9%) in the latter groups. Comparison of episode incidence revealed no significant difference in the primary end point (P=0.84). In an Andersen-Gill regression model with multiple end point recurrences, the difference between the study arms significantly favored catheter ablation for both the primary end point and all but one of the predefined subgroups of detected arrhythmia events. CONCLUSIONS: SMS failed to meet the primary end point of time to first ventricular tachycardia/ventricular fibrillation recurrence. However, catheter ablation did reduce the total number of ICD interventions during the duration of follow-up. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov. Unique identifier: NCT00170287.


Assuntos
Ablação por Cateter/métodos , Doença da Artéria Coronariana/cirurgia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Taquicardia Ventricular/cirurgia , Fibrilação Ventricular/cirurgia , Adulto , Idoso , Mapeamento Potencial de Superfície Corporal , Ablação por Cateter/mortalidade , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Prognóstico , Modelos de Riscos Proporcionais , Medição de Risco , Índice de Gravidade de Doença , Estatísticas não Paramétricas , Análise de Sobrevida , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidade , Resultado do Tratamento , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/mortalidade
7.
Pesqui. vet. bras ; 32(11): 1169-1173, Nov. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-658088

RESUMO

Foi realizado um estudo retrospectivo dos resultados dos exames citológicos provenientes dos arquivos do Serviço de Citopatologia do Laboratório de Patologia Animal, Faculdade de Medicina Veterinária e Zootecnia, Universidade Estadual Paulista, Botucatu, São Paulo, entre janeiro de 1994 e dezembro de 2008. Do total de 139.986 animais atendidos no Hospital Veterinário da instituição, 11.468 (8,2%) foram encaminhados para exame citológico. Desses diagnósticos, 57,28% corresponderam a lesões neoplásicas, 19,28% a lesões inflamatórias e 14,79% a processos não neoplásicos (imunológicos, degenerativos, hiperplásicos ou displásicos). Não foi possível concluir o diagnóstico por meio do exame citológico em 7,28% dos casos e não haviam informações diagnósticas registradas em 1,37% dos casos. Dentre os animais que mais receberam indicação para exame citológico destacaram-se os caninos (92,06%), seguidos pelos felinos (4,08%), bovinos (1,77%) e equinos (1,30%). Lesoes neoplásicas foram as mais comumente observadas e foram mais prevalentes nos cães (59,18%), afetando principalmente animais com idade média de 119,60 meses e principalmente fêmeas (61,61%). O incremento anual observado ao longo dos 15 anos de aplicação da citologia demonstra que o exame citológico é um método de suma importância para confirmar, sugerir ou afastar o diagnóstico de diversas afecções, inclusive neoplasia, em todas as espécies animais.


A retrospective study was conducted over the results of cytological examination in the files of the Department of Cytopathology, Laboratory of Animal Pathology, School of Veterinary Medicine and Animal Science, São Paulo State University, Botucatu, SP, Brazil, from January 1994 to December 2008. Out of 139,986 animals referred to the teaching Veterinary Hospital, 11,468 (8.2%) were submitted to cytological examination. From these animals, 57.28% had a neoplastic lesion, 19.28% had inflammatory lesions, and 14.79% had non-neoplastic processes (immune-mediated, degenerative, hyperplastic, or dysplastic condition). By means of cytology, 7.28% of the cases were unable to be diagnosed, and there was no recorded diagnostic information in 1.37% of cases. The species that more commonly had samples submitted to cytology was the dog (92.06%), followed by cats (4.08%), cattle (1.77%), and horses (1.30%). As to the predominance of the observed processes, greater importance was given to neoplastic lesions. These were prevalent in dogs (59.18%), with a mean age of 119.60 months, and affecting mainly females (61.61%). The annual increase observed over the 15 years of application of cytology demonstrates that the cytological examination is a method of great importance to confirm, suggest, or exclude the diagnosis of various diseases, including cancer, in all animal species.


Assuntos
Animais , Biologia Celular/estatística & dados numéricos , Biologia Celular/tendências , Técnicas e Procedimentos Diagnósticos/veterinária , Neoplasias/diagnóstico , Neoplasias/veterinária
8.
Europace ; 14(3): 410-5, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22048993

RESUMO

AIMS: The aim of this study was to assess the role of a non-pharmacological approach on the frequency of traumatic injuries and syncope recurrence in patients with vasovagal syncope and normal hearts. We report the experience in our syncope centre with a standardized education and teaching protocol for patients with vasovagal syncope. The treatment of vasovagal syncope is often complex and discouraging. Besides medical options, behaviour modification is a main component of therapy but has no statistical evidence to support its use. METHODS AND RESULTS: Between January 1999 and September 2006, we prospectively enrolled all patients with vasovagal syncope. The patients were counselled about the benign nature of their disease. Specific recommendations were made according to a standardized education protocol established at our syncope centre. A pre-/post-study was conducted to investigate the effectiveness of our approach on syncope recurrence and frequency of injury as the study endpoints. Complete follow-up data were available from 85% of the study population (316 of 371) after a mean time of 710 ± 286 days (mean age 50 years; standard deviation ± 18 years, 160 female). Eighty-seven patients (27.5%) had a syncope recurrence with 22 suffering an injury during syncope. During the follow-up period, the syncope burden per month was significantly reduced from 0.35 ± 0.03 at initial presentation to 0.08 ± 0.02 (P< 0.001). The frequency of traumatic syncope was significantly lower at the time of recurrence compared with the initial presentation (25 vs. 42%; McNemar's test P= 0.02). CONCLUSION: A standardized education protocol significantly reduces traumatic injuries and syncope recurrence in patients with vasovagal syncope.


Assuntos
Conhecimentos, Atitudes e Prática em Saúde , Síncope Vasovagal/prevenção & controle , Ferimentos e Lesões/prevenção & controle , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Síncope Vasovagal/complicações , Resultado do Tratamento , Ferimentos e Lesões/etiologia
9.
Europace ; 13(2): 262-9, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21097478

RESUMO

AIMS: To collect information on the use of the Reveal implantable loop recorder (ILR) in the patient care pathway and to investigate its effectiveness in the diagnosis of unexplained recurrent syncope in everyday clinical practice. METHODS AND RESULTS: Prospective, multicentre, observational study conducted in 2006-2009 in 10 European countries and Israel. Eligible patients had recurrent unexplained syncope or pre-syncope. Subjects received a Reveal Plus, DX or XT. Follow up was until the first recurrence of a syncopal event leading to a diagnosis or for ≥1 year. In the course of the study, patients were evaluated by an average of three different specialists for management of their syncope and underwent a median of 13 tests (range 9-20). Significant physical trauma had been experienced in association with a syncopal episode by 36% of patients. Average follow-up time after ILR implant was 10±6 months. Follow-up visit data were available for 570 subjects. The percentages of patients with recurrence of syncope were 19, 26, and 36% after 3, 6, and 12 months, respectively. Of 218 events within the study, ILR-guided diagnosis was obtained in 170 cases (78%), of which 128 (75%) were cardiac. CONCLUSION: A large number of diagnostic tests were undertaken in patients with unexplained syncope without providing conclusive data. In contrast, the ILR revealed or contributed to establishing the mechanism of syncope in the vast majority of patients. The findings support the recommendation in current guidelines that an ILR should be implanted early rather than late in the evaluation of unexplained syncope.


Assuntos
Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Eletrocardiografia Ambulatorial/estatística & dados numéricos , Eletrodos Implantados , Monitorização Fisiológica/estatística & dados numéricos , Síncope/etiologia , Adulto , Idoso , Arritmias Cardíacas/fisiopatologia , Testes Diagnósticos de Rotina , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/métodos , Europa (Continente) , Feminino , Seguimentos , Humanos , Israel , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Guias de Prática Clínica como Assunto , Estudos Prospectivos , Recidiva , Sistema de Registros , Estudos Retrospectivos , Síncope/epidemiologia
10.
Cardiology ; 117(1): 14-20, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20881389

RESUMO

OBJECTIVES: The effect of angiotensin-converting enzyme inhibitors (ACE-I) and angiotensin II receptor blockers (ARBs) on the long-term outcome after pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) is unknown. METHODS: This matched-pair study included 102 patients with PAF treated with ACE-I or ARBs (group 1) and 102 control subjects (group 2) after standardized PVI. Tele-ECG recorders were used to detect the end point of the first PAF recurrence after a 3-month blanking period. RESULTS: Median follow-up was 2.1 years (range 0.3-6.3). In group 1, 51 (50%) patients suffered recurrences, with a mean time to recurrence of 3.2 years (95% CI 2.6-3.8). In group 2, 67 (65.7%) patients presented PAF after a mean period of 2.2 years (95% CI 1.7-2.8; p = 0.009). A second ablation was performed in 31 (50%) patients from the treatment group and in 48 (66.7%) patients from the control group (p = 0.02). Multivariate Cox analysis showed treatment with ACE-I and ARBs to be the only significant predictor of a reduced recurrence rate (HR 0.49, 95% CI 0.32-0.75). CONCLUSION: ACE-I and ARBs were effective for the preservation of sinus rhythm after PAF ablation, and they reduced the reablation rate.


Assuntos
Bloqueadores do Receptor Tipo 1 de Angiotensina II/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Fibrilação Atrial , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Terapia Combinada , Bases de Dados Factuais , Eletrocardiografia Ambulatorial , Feminino , Seguimentos , Sistema de Condução Cardíaco/efeitos dos fármacos , Sistema de Condução Cardíaco/fisiologia , Humanos , Masculino , Análise por Pareamento , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Fatores de Risco , Prevenção Secundária , Resultado do Tratamento
11.
Europace ; 12(11): 1608-15, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20823041

RESUMO

AIMS: Although Eustachian valves and recesses have been related to resistance to block, the effect of convective cooling by the right coronary artery (RCA) has not been evaluated in the clinical setting. METHODS AND RESULTS: The distance and course of the RCA in relation to the cavotricuspid isthmus (CTI) in addition to variants of CTI anatomy and the presence of Eustachian valves were analysed from computed tomography scans of 54 patients. Ablation power was titrated using a step-up protocol. Invasive follow-up was available for 34 patients. The RCA came closest to the CTI inferiorly separated by a mean of 5.3 ± 2.5 mm compared with 7.3 ± 3.3 mm septally and 5.7 ± 2.3 mm anteriorly (P < 0.01). The maximum power required for CTI block correlated inversely with the distance of the RCA to the CTI, whereas the cumulative energy was highest in the presence of recesses. Neither failure of acute block nor a higher rate of conduction recurrence could be attributed to variants of CTI anatomy or the presence of a Eustachian valve. Using multivariate analysis, a position of the RCA underneath the central part of the CTI was the only significant predictor for late conduction recurrence. These patients showed a 2.7 mm larger distance of the RCA to the tricuspid valve plane (P = 0.05). CONCLUSION: The RCA affects CTI ablation as higher power settings are required at closer distances to the ablation site. Late conduction recurrences were observed in patients with a variation of the RCA, leaving the atrioventricular groove towards the atrial aspect.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter , Vasos Coronários/anatomia & histologia , Sistema de Condução Cardíaco/cirurgia , Valva Tricúspide/cirurgia , Veia Cava Inferior/cirurgia , Idoso , Antiarrítmicos/uso terapêutico , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/tratamento farmacológico , Flutter Atrial/fisiopatologia , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/fisiopatologia
12.
J Interv Card Electrophysiol ; 29(2): 83-91, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20803061

RESUMO

BACKGROUND: Discrimination of local and far field potentials during sinus rhythm and atrial fibrillation (AF) is essential for successful pulmonary vein (PV) isolation. We sought to introduce an expert system for the classification of electrophysiologic PV signals. METHODS: For the expert system database, we analyzed ablation procedures of 50 patients with paroxysmal and persistent AF. Standard circumferential catheters and bipolar recordings were required. In a prospective trial, the expert system was compared with the performing electrophysiologists' classifications of potentials during 15 procedures. A total of 1,343 recordings of local PV and far field signals were validated by the sudden disappearance of local potentials during ablation, the presence of dissociated PV activity, and pacing maneuvers. A fast Fourier transform was applied to the individual potentials. Analysis continued in the amplitude and phase representation. RESULTS: Four parameters significant (p < 0.001) for classification were identified and entered a logistic regression model. Overall sensitivity and specificity of the model was 87% with minor, nonsignificant variations for individual PVs and different underlying rhythms. Concordance with ad hoc electrophysiologists' classification of local potentials was 70%, which increased during post hoc analysis to 86% since classification of 14% of the potentials had to be revised. For these potentials, the expert system correctly predicted their local origin in 86%. CONCLUSION: An expert system for the evaluation of electrophysiologic signals based on morphology analysis using the Fourier transform is feasible. The ease of use and online availability facilitate a widespread use for AF ablation procedures.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Sistemas Inteligentes , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Veias Pulmonares/fisiopatologia , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Feminino , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Cirurgia Assistida por Computador/métodos
13.
Int J Cardiol ; 145(2): 368-370, 2010 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-20303606

RESUMO

A pilot study was performed to determine the efficacy of low energy biphasic external cardioversion in common type atrial flutter. In the majority of patients (70%) successful cardioversion was achieved with low energy levels of 20 or 30 J; however a considerable number of patients (15%) were initially cardioverted to atrial fibrillation, needing an additional cardioversion with an even higher energy level.


Assuntos
Flutter Atrial/metabolismo , Flutter Atrial/terapia , Cardioversão Elétrica , Metabolismo Energético/fisiologia , Idoso , Flutter Atrial/fisiopatologia , Cardioversão Elétrica/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos
14.
Lancet ; 375(9708): 31-40, 2010 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-20109864

RESUMO

BACKGROUND: In patients with ventricular tachycardia (VT) and a history of myocardial infarction, intervention with an implantable cardioverter defibrillator (ICD) can prevent sudden cardiac death and thereby reduce total mortality. However, ICD shocks are painful and do not provide complete protection against sudden cardiac death. We assessed the potential benefit of catheter ablation before implantation of a cardioverter defibrillator. METHODS: The Ventricular Tachycardia Ablation in Coronary Heart Disease (VTACH) study was a prospective, open, randomised controlled trial, undertaken in 16 centres in four European countries. Patients aged 18-80 years were eligible for enrolment if they had stable VT, previous myocardial infarction, and reduced left-ventricular ejection fraction (LVEF; 30%). Patients were followed up for at least 1 year. The primary endpoint was the time to first recurrence of VT or ventricular fibrillation (VF). Analysis was by intention to treat (ITT). This study is registered with ClinicalTrials.gov, number NCT00919373. FINDINGS: 107 patients were included in the ITT population (ablation group, n=52; control group, n=55). Two patients (one in each group) withdrew consent immediately after randomisation without any follow-up data and one patient (ablation group) was excluded because of a protocol violaton. Mean follow-up was 22.5 months (SD 9.0). Time to recurrence of VT or VF was longer in the ablation group (median 18.6 months [lower quartile 2.4, upper quartile not determinable]) than in the control group (5.9 months [IQR 0.8-26.7]). At 2 years, estimates for survival free from VT or VF were 47% in the ablation group and 29% in the control group (hazard ratio 0.61; 95% CI 0.37-0.99; p=0.045). Complications related to the ablation procedure occurred in two patients; no deaths occurred within 30 days after ablation. 15 device-related complications requiring surgical intervention occurred in 13 patients (ablation group, four; control group, nine). Nine patients died during the study (ablation group, five; control group, four). INTERPRETATION: Prophylactic VT ablation before defibrillator implantation seemed to prolong time to recurrence of VT in patients with stable VT, previous myocardial infarction, and reduced LVEF. Prophylactic catheter ablation should therefore be considered before implantation of a cardioverter defibrillator in such patients. FUNDING: St Jude Medical.


Assuntos
Ablação por Cateter , Doença das Coronárias/complicações , Desfibriladores Implantáveis , Taquicardia Ventricular/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/terapia , Resultado do Tratamento
15.
J Cardiovasc Electrophysiol ; 21(1): 70-7, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19732235

RESUMO

INTRODUCTION: The mechanism of mechanical dyssynchrony in postinfarction patients with a narrow QRS complex is not defined but essential for cardiac resynchronization therapy (CRT). METHODS AND RESULTS: Left ventricular electrical activation and subsequent wall motion were recorded for 16 patients with ischemic cardiomyopathy during intrinsic rhythm using a modified NOGA electromechanical mapping system. Ten patients presented mechanical dyssynchrony on tissue Doppler imaging, while 6 patients served as control subjects. The local activation time (LAT) was set by the maximum downslope of the unipolar electrogram. Local wall motion time (LMT) was defined as the time needed for the catheter tip to traverse half of its maximum inward deflection during systole. LAT and LMT were measured relative to the onset of the QRS complex. Electrical activation showed a septal-to-lateral pattern in all patients with a mean endocardial activation time of 65 +/- 13 ms. Control subjects exhibited 97.5% of all LMTs <290 +/- 17 ms. Delayed motion areas (cut-off LMT > 300 ms) showed no slowing of conduction. Wall motion time corrected for differences in electrical activation (LMT-LAT) was significantly longer in delayed (289 +/- 34 ms) than in regular (204 +/- 24 ms) motion areas (P = 0.002). Delayed motion segments were hypokinetic on echocardiography and presented a lower maximum inward motion (9.9 +/- 1.1 mm) compared to regular segments (10.9 +/- 1.2 mm) on electromechanical maps (P = 0.004). Viability, however, was preserved with unipolar and bipolar voltage amplitude >7 mV and >1.5 mV for 79% of all delayed motion areas. CONCLUSION: Dyssynchronous segments of an ischemic myocardium show unimpaired local activation but slow wall motion, thereby limiting the benefit of ventricular preexcitation via CRT.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Eletrocardiografia/métodos , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/etiologia , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
16.
Heart Rhythm ; 6(12): 1699-705, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19959115

RESUMO

BACKGROUND: Recent studies have shown that cryoablation and radiofrequency (RF) ablation are comparable with regard to success rates and safety in the treatment of common atrial flutter (AFL). Long-term success requires persistence of bidirectional conduction block (BCB) in the inferior cavotricuspid isthmus (CTI). OBJECTIVE: The purpose of this study was to determine the persistence of BCB in a prospective randomized multicenter trial of the two ablation techniques. METHODS: A total of 191 patients were randomized to RF ablation or cryoablation of the CTI using an 8-mm-tip catheter. In all patients, BCB was defined as the ablation end-point. Primary end-point of the study was nonpersistence of achieved BCB and/or ECG-documented relapse of common AFL within 3-month follow-up. RESULTS: Acute success rates were 91% (83/91) in the RF group and 89% (80/90) in the cryoablation group (P = NS). Invasive follow-up after 3 months with repeated electrophysiologic study was available for 60 patients in the RF group and 64 patients in the cryoablation group. Persistent BCB could be confirmed in 85% of the RF group versus 65.6% of the cryoablation group. The primary end-point was achieved in 15% of the RF group and 34.4% of the cryoablation group (P = .014). As a secondary end-point, pain perception during ablation was significant lower in the cryoablation group (P <.001). CONCLUSION: Persistence of BCB in patients treated with cryoablation reinvestigated after 3 months is inferior to that patients treated with RF ablation, as evidenced by the higher recurrence rate of common AFL seen in this study.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Sistema de Condução Cardíaco/cirurgia , Valva Tricúspide/cirurgia , Veia Cava Inferior/cirurgia , Idoso , Eletrofisiologia Cardíaca , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento
17.
Am J Cardiol ; 104(11): 1547-50, 2009 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-19932790

RESUMO

External cardioversion is an established and very important tool to terminate symptomatic atrial flutter. The superiority of the biphasic waveform has been demonstrated for atrial flutter, but whether electrode position affects the efficacy of cardioversion in this population is not known. The aim of this trial was to evaluate whether anterior-lateral (A-L) compared with anterior-posterior (A-P) electrode position improves cardioversion results. Of 130 screened patients, 96 (72 men, mean age 62 +/- 12 years) were included and randomly assigned to a cardioversion protocol with either A-L or A-P electrode position. In each group, 48 patients received sequential biphasic waveform shocks using a step-up protocol consisting of 50, 75, 100, 150, or 200 J. The mean energy (65 +/- 13 J for A-L vs 77 +/- 13 J for A-P, p = 0.001) and mean number of shocks (1.48 +/- 1.01 for A-L vs 1.96 +/- 1.00 for A-P, p = 0.001) required for successful cardioversion were significantly lower in the A-L group. The efficacy of the first shock with 50 J in the A-L electrode position (35 of 48 patients [73%]) was also highly significantly greater than the first shock with 50 J in the A-P electrode position (18 of 48 patients [36%]) (p = 0.001). In conclusion, the A-L electrode position increases efficacy and requires fewer energy and shocks in external electrical cardioversion of common atrial flutter. Therefore, A-L electrode positioning should be recommended for the external cardioversion of common atrial flutter.


Assuntos
Flutter Atrial/terapia , Cardioversão Elétrica/métodos , Idoso , Algoritmos , Cardioversão Elétrica/instrumentação , Eletrodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
18.
Radiology ; 253(2): 364-71, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19703849

RESUMO

PURPOSE: To evaluate the performance of velocity-encoded (VENC) magnetic resonance (MR) imaging, as compared with pulsed-wave echocardiography (PW-ECHO), in the quantification of interventricular mechanical dyssynchrony (IVMD) as a predictor of response to cardiac resynchronization therapy (CRT). MATERIALS AND METHODS: The study was approved by the local ethics committee, and all patients provided written informed consent. The study involved the examination of 45 patients (nine women, 36 men; median age, 60 years; interquartile age range, 47-69 years) with New York Heart Association class 2.0-3.0 heart failure and a reduced left ventricular ejection fraction (median, 25%; interquartile range, 21%-32%), with (n = 25) or without (n = 20) left bundle branch block. Aortic and pulmonary flow curves were constructed by using VENC MR imaging and PW-ECHO. IVMD was defined as the difference between the onset of aortic flow and the onset of pulmonary flow. Intraclass correlation coefficient, Spearman correlation coefficient, Bland-Altman, and Cohen kappa analyses were used to assess agreement between observers and methods. RESULTS: Inter- and intraobserver agreement regarding VENC MR imaging IVMD measurements was very good (intraclass r = 0.96, P < .001; mean bias, -3 msec +/- 11 [standard deviation] and 0 msec +/- 10, respectively). A strong correlation (Spearman r = 0.92, P < .001) and strong agreement (mean difference, -6 msec +/- 16) were found between VENC MR imaging and PW-ECHO in the quantification of IVMD. Agreement between VENC MR imaging and PW-ECHO in the identification of potential responders to CRT was excellent (Cohen kappa = 0.94). CONCLUSION: VENC MR measurements of IVMD are equivalent to PW-ECHO measurements and can be used to identify potential responders to CRT.


Assuntos
Imageamento por Ressonância Magnética , Disfunção Ventricular Esquerda/diagnóstico , Idoso , Valva Aórtica , Velocidade do Fluxo Sanguíneo , Estimulação Cardíaca Artificial , Ecocardiografia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valva Pulmonar , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/terapia
19.
Am J Hypertens ; 22(9): 971-9, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19574960

RESUMO

BACKGROUND: Noninvasive applanation tonometry (APT) is useful to assess aortic stiffness and pulse wave reflection. Moreover, APT can predict outcome in many conditions such as arterial hypertension. In this study, we test whether APT measurements relate to progression of aortic disease in Marfan syndrome (MFS). METHODS: We performed APT in 50 consecutive, medically treated adults with MFS (19 men and 31 women aged 32 +/- 13 years), who had not undergone previous cardiovascular surgery. During 22 +/- 16 months of follow-up, 26 of these patients developed progression of aortic disease, which we defined as progression of aortic root diameters >or=5 mm/annum (18 individuals), aortic surgery >or=3 months after APT (seven individuals), or onset of acute aortic dissection any time after APT (one individual). RESULTS: Univariate Cox regression analysis suggested an association of aortic disease progression with age (P = 0.001), total cholesterol levels (P = 0.04), aortic root diameter (P = 0.007), descending aorta diameter (P = 0.01), aortic root ratio (P = 0.02), and augmentation index (AIx@HR75; P < 0.006). Multivariate Cox regression analysis confirmed an independent impact on aortic disease progression exclusively for baseline aortic root diameters (hazard ratio = 1.347; 95% confidence interval (CI) 1.104-1.643; P = 0.003) and AIx@HR75 (hazard ratio = 1.246; 95% CI 1.029-1.508; P = 0.02). In addition, Kaplan-Meier survival curve analysis illustrated significantly lower rates of aortic root disease progression both with lower AIx@HR75 (P = 0.025) and with lower pulse wave velocity (PWV) values (P = 0.027). CONCLUSIONS: We provide evidence that APT parameters relate to aortic disease progression in medically treated patients with MFS. We believe that APT has a potential to improve risk stratification in the clinical management of MFS patients.


Assuntos
Doenças da Aorta/fisiopatologia , Síndrome de Marfan/fisiopatologia , Adulto , Progressão da Doença , Elasticidade , Feminino , Hemodinâmica , Humanos , Masculino , Manometria/métodos , Síndrome de Marfan/diagnóstico , Análise de Regressão
20.
J Cardiovasc Electrophysiol ; 20(4): 416-21, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19017338

RESUMO

BACKGROUND: Predictors for recurrence of syncope are lacking in patients with vasovagal syncope. The aim of this study was to identify risk factors for recurrence of syncope and develop a simple prognostic risk score of clinical value. METHODS: Two hundred seventy-six patients with a history of vasovagal syncope were prospectively followed for 2 years. Diagnosis of vasovagal syncope was based on clinical history and negative standard work-up. Inclusion in the study was independent from the result of the head-up tilt test, which was performed in all cases. Risk factors for syncope recurrence were evaluated by the Cox proportional hazards regression model and implemented in a risk score, which was validated with the log-rank test and an internal cross-validation. RESULTS: The Cox-regression analysis identified the number of previous syncopal events, history of bronchial asthma, and female gender as predictors for syncope recurrence (all P < 0.05). In contrast, head-up tilt test response had no predictive value (P = 0.881). Developing a risk score, study patients were identified as having high (recurrence rate during 2 years of follow-up: 37.2%), intermediate (24.8%), and low (6.5%) risk for syncope recurrence (receiver operating characteristic [ROC] of score 0.83, P < 0.01; Log-rank test for event-free survival, P < 0.005). CONCLUSIONS: In patients with vasovagal syncope, risk of recurrence can be stratified and is predictable based on a simple risk score.


Assuntos
Síncope Vasovagal/diagnóstico , Adulto , Idoso , Asma/complicações , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Prospectivos , Curva ROC , Recidiva , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Fatores Sexuais , Síncope Vasovagal/etiologia , Síncope Vasovagal/terapia , Teste da Mesa Inclinada , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...