Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Cardiol ; 86(1): 41-5, 2000 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-10867090

RESUMO

"Ad hoc" percutaneous coronary interventions (PCIs)-those performed immediately after diagnostic catheterization-have been reported in earlier studies to be safe with a suggestion of higher risk in certain subgroups. Despite increasing use of this strategy, no data are available in recent years with new device technology. We studied use of an ad hoc strategy in a large regional population to determine its use and outcomes compared with staged procedures. A database from the 6 centers performing PCIs in northern New England and 1 center in Massachusetts was analyzed. During 1997, excluding only patients requiring emergency procedures or those with a prior PCI, 4,136 PCIs were performed, 1,748 (42.3%) of these being ad hoc procedures. Patients having ad hoc procedures were less likely to have peripheral vascular disease, renal failure, prior myocardial infarction, or coronary artery bypass surgery, congestive heart failure, or poor left ventricular function, and more likely to have received preprocedural intravenous heparin or nitroglycerin or to have required an urgent procedure. Narrowings treated during ad hoc procedures were less frequently types B and C or in saphenous vein grafts. Adjusted rates of clinical success were not different between ad hoc and non-ad hoc procedures (93.7% vs 93.6%); there was no difference in the incidence of death (0.6% vs 0.5%), emergency (0. 9% vs 0.8%) or any (1.4% vs 0.8%) coronary artery bypass surgery, or myocardial infarction (2.6% vs 2.0%). As currently practiced in our region, ad hoc intervention is used selectively with outcomes similar for ad hoc and non-ad hoc procedures.


Assuntos
Angina Pectoris/diagnóstico , Angina Pectoris/terapia , Angioplastia Coronária com Balão/normas , Aterectomia Coronária/normas , Cateterismo Cardíaco , Angina Pectoris/mortalidade , Angioplastia Coronária com Balão/estatística & dados numéricos , Aterectomia Coronária/estatística & dados numéricos , Ponte de Artéria Coronária/estatística & dados numéricos , Feminino , Mortalidade Hospitalar , Humanos , Incidência , Masculino , Massachusetts/epidemiologia , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/cirurgia , New England/epidemiologia , Fatores de Risco , Segurança , Stents , Taxa de Sobrevida , Resultado do Tratamento
2.
J Am Coll Cardiol ; 34(5): 1471-80, 1999 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-10551694

RESUMO

OBJECTIVES: The purpose of this study was to examine the relationship between annual operator volume and outcomes of percutaneous coronary interventions (PCIs) using contemporaneous data. BACKGROUND: The 1997 American College of Cardiology (ACC)/American Heart Association task force based their recommendation that interventionists perform > or = 75 procedures per year to maintain competency in PCI on data collected largely in the early 1990s. The practice of interventional cardiology has since changed with the availability of new devices and drugs. METHODS: Data were collected from 1994 through 1996 on 15,080 PCIs performed during 14,498 hospitalizations by 47 interventional cardiologists practicing at the five high volume (>600 procedures per hospital per year) hospitals in northern New England and one Massachusetts-based institution that support these procedures. Operators were categorized into terciles based on their annualized volume of procedures. Multivariate regression analysis was used to control for case-mix. In-hospital outcomes included death, emergency coronary artery bypass graft surgery (eCABG), non-emergency CABG (non-eCABG), myocardial infarction (MI), death and clinical success (> or = 1 attempted lesion dilated to < 50% residual stenosis and no death, CABG or MI). RESULTS: Average annual procedure rates varied across terciles from low = 68, middle = 115 and high = 209. After adjusting for case-mix, clinical success rates were comparable across terciles (low, middle and high terciles: 90.9%, 88.8% and 90.7%, Ptrend = 0.237), as were all the adverse outcomes including death (low-risk patients = 0.45%, 0.41%, 0.71%, Ptrend = 0.086; high-risk patients = 5.68%, 5.99%, 7.23%, Ptrend = 0.324), eCABG (1.74%, 2.05%, 1.75%, Ptrend = 0.733) and MI (2.57%, 1.90%, 1.86%, Ptrend = 0.065). CONCLUSIONS: Using current data, there is no significant relationship between operator volumes averaging > or = 68 per year and outcomes at high volume hospitals. Future efforts should be directed at determining the generalizability of these results.


Assuntos
Angioplastia Coronária com Balão/estatística & dados numéricos , Competência Clínica , Doença das Coronárias/terapia , Ponte de Artéria Coronária/estatística & dados numéricos , Humanos , Modelos Logísticos , New England , Qualidade da Assistência à Saúde , Stents/estatística & dados numéricos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...