1.
IEEE Trans Inf Technol Biomed ; 12(4): 470-9, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18632327

RESUMO

Biomedical engineering research efforts have accomplished another level of a "technological solution" for diabetes: an artificial pancreas to be used by patients and supervised by healthcare professionals at any time and place. Reliability of continuous glucose monitoring, availability of real-time programmable insulin pumps, and validation of safe and efficient control algorithms are critical components for achieving that goal. Nevertheless, the development and integration of these new technologies within a telemedicine system can be the basis of a future artificial pancreas. This paper introduces the concept, design, and evaluation of the "intelligent control assistant for diabetes, INCA" system. INCA is a personal digital assistant (PDA)-based personal smart assistant to provide patients with closed-loop control strategies (personal and remote loop), based on a real-time continuous glucose sensor (Guardian RT, Medtronic), an insulin pump (D-TRON, Disetronic Medical Systems), and a mobile general packet radio service (GPRS)-based telemedicine communication system. Patient therapeutic decision making is supervised by doctors through a multiaccess telemedicine central server that provides to diabetics and doctors a Web-based access to continuous glucose monitoring and insulin infusion data. The INCA system has been technically and clinically evaluated in two randomized and crossover clinical trials showing an improvement on glycaemic control of diabetic patients.


Assuntos
Automonitorização da Glicemia/instrumentação , Computadores de Mão , Diabetes Mellitus/tratamento farmacológico , Autoadministração/instrumentação , Telemedicina/instrumentação , Terapia Assistida por Computador/instrumentação , Órgãos Bioartificiais , Sistemas Computacionais , Desenho de Equipamento , Análise de Falha de Equipamento , Sistemas de Infusão de Insulina , Pâncreas , Autoadministração/métodos , Terapia Assistida por Computador/métodos
2.
IEEE Trans Inf Technol Biomed ; 10(2): 395-402, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16617628

RESUMO

For a diabetes mellitus patient, tight control of glucose level is essential. Results are reported of an investigation of the suitability of existing wearable continuous insulin infusors controlled and adjusted by a control algorithm using continuous glucose measurements as input to perform the functionality of an artificial pancreas. Special attention was given to the development of a continuous glucose monitor and to evaluate which quality of input data is necessary for the control algorithm. In clinical trials, it was found that for patients in a controlled environment an autonomously regulating control algorithm leads to an improved adjustment of patient glucose values and less overall insulin infusion as compared with the best fixed preprogrammed insulin infusion profiles of standard pump therapy. For the limited number of cases studied here, functionality of the control algorithm could tolerate some delay between the actual glucose values in the patient interstitial fluid and the algorithm input of up to 30 min. A quasicontinuous glucose measurement delivering actual glucose values every 5-10 min seems to be suited to control an artificial pancreas.


Assuntos
Assistência Ambulatorial/métodos , Automonitorização da Glicemia/instrumentação , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/tratamento farmacológico , Quimioterapia Assistida por Computador/instrumentação , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Algoritmos , Inteligência Artificial , Glicemia/análise , Automonitorização da Glicemia/métodos , Quimioterapia Assistida por Computador/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Retroalimentação , Humanos
3.
Physiol Meas ; 25(4): 905-20, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15382830

RESUMO

A nonlinear model predictive controller has been developed to maintain normoglycemia in subjects with type 1 diabetes during fasting conditions such as during overnight fast. The controller employs a compartment model, which represents the glucoregulatory system and includes submodels representing absorption of subcutaneously administered short-acting insulin Lispro and gut absorption. The controller uses Bayesian parameter estimation to determine time-varying model parameters. Moving target trajectory facilitates slow, controlled normalization of elevated glucose levels and faster normalization of low glucose values. The predictive capabilities of the model have been evaluated using data from 15 clinical experiments in subjects with type 1 diabetes. The experiments employed intravenous glucose sampling (every 15 min) and subcutaneous infusion of insulin Lispro by insulin pump (modified also every 15 min). The model gave glucose predictions with a mean square error proportionally related to the prediction horizon with the value of 0.2 mmol L(-1) per 15 min. The assessment of clinical utility of model-based glucose predictions using Clarke error grid analysis gave 95% of values in zone A and the remaining 5% of values in zone B for glucose predictions up to 60 min (n = 1674). In conclusion, adaptive nonlinear model predictive control is promising for the control of glucose concentration during fasting conditions in subjects with type 1 diabetes.


Assuntos
Glicemia/fisiologia , Diabetes Mellitus Tipo 1/fisiopatologia , Hipoglicemiantes/uso terapêutico , Insulina/análogos & derivados , Insulina/uso terapêutico , Modelos Teóricos , Previsões , Humanos , Hipoglicemiantes/farmacocinética , Hipoglicemiantes/farmacologia , Insulina/farmacocinética , Insulina/farmacologia , Insulina Lispro
4.
Diabetes Technol Ther ; 6(3): 307-18, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15198833

RESUMO

The objective of the project Advanced Insulin Infusion using a Control Loop (ADICOL) was to develop a treatment system that continuously measures and controls the glucose concentration in subjects with type 1 diabetes. The modular concept of the ADICOL's extracorporeal artificial pancreas consisted of a minimally invasive subcutaneous glucose system, a handheld PocketPC computer, and an insulin pump (D-Tron, Disetronic, Burgdorf, Switzerland) delivering subcutaneously insulin lispro. The present paper describes a subset of ADICOL activities focusing on the development of a glucose controller for semi-closed-loop control, an in silico testing environment, clinical testing, and system integration. An incremental approach was adopted to evaluate experimentally a model predictive glucose controller. A feasibility study was followed by efficacy studies of increasing complexity. The ADICOL project demonstrated feasibility of a semi-closed-loop glucose control during fasting and fed conditions with a wearable, modular extracorporeal artificial pancreas.


Assuntos
Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Sistemas de Infusão de Insulina , Glicemia/análise , Desenho de Equipamento , Humanos , Monitorização Ambulatorial/instrumentação , Monitorização Ambulatorial/métodos