Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Forensic Sci Int ; 335: 111278, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35344897

RESUMO

INTRODUCTION: Excessive use of alcohol increases the risk to be involved in a road traffic accident. According to many legislations, certain maximal blood-alcohol-concentrations (BAC) have to be respected to be allowed to drive on public roads. Acute alcohol intoxication is evaluated by blood analysis or analysis of the exhaled alveolar air. In many cases, evaluation of the alcohol consumption during the past months can be useful. In this light, ethyl glucuronide (EtG), a direct alcohol biomarker which can be found in keratinized matrices (hair, nails) is valuable and can be used for the long-term follow-up of alcohol consumption. RESEARCH AIM: To compare the EtG concentration in hair and fingernails from teetotalers, and to propose a cut-off value for EtG in fingernails for alcohol abstinence. MATERIAL AND METHODS: Paired samples of hair and nails were collected from participants, with a minimum age of 18 years. They all stated alcohol abstinence for at least 6 months. Participants were asked to complete a questionnaire about age, gender and the use of hair care products and nail polish. Analysis of EtG in the nail and hair samples were conducted following a validated analytical method. RESULTS: From 126 participants a hair and nail sample were collected. Of this group, 15 participants were finally not included in the study because of insufficient amount of hair or nails collected. There were more female participants (65%) and the average age of participants was 39 years. The EtG concentration in hair was below the limit of detection of 2.1 pg/mg in all but 4 samples (2.1, 2.1, 2.9, and 3.5 pg/mg). The EtG concentration in nails was below the limit of detection in 97 of the 111 samples. The concentrations in nails ranged between 2.3 and 23 pg/mg. DISCUSSION AND CONCLUSION: In a population of 111 teetotalers, the 97.5% percentile of EtG concentrations in fingernails is 7.6 pg/mg. The highest EtG concentration observed was 23 pg/mg. These results suggest that the cut-off value for alcohol abstinence may be lower than the previous suggested 59 pg/mg and 37 pg/mg.


Assuntos
Abstinência de Álcool , Alcoolismo , Adolescente , Adulto , Consumo de Bebidas Alcoólicas , Alcoolismo/diagnóstico , Biomarcadores/análise , Correlação de Dados , Etanol , Feminino , Glucuronatos/análise , Cabelo/química , Humanos , Unhas/química , Detecção do Abuso de Substâncias/métodos
2.
Am J Forensic Med Pathol ; 42(2): 198-200, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33186130

RESUMO

ABSTRACT: Cocaine is often sold in a mixture with levamisole to increase the profit margin and potentiate the euphoric effect. Apart from an overdose, cocaine can induce a wide range of clinical symptoms. We present a case of cocaine/levamisole-induced pauci-immune glomerulonephritis. A 22-year-old patient was sent to the hospital after a laboratory result showed an unexpected acute kidney injury, with an estimated glomerular filtration rate of 34 mL/min/1.73 m2. The medical history included cocaine abuse. Renal biopsy showed a pauci-immune necrotizing glomerulonephritis. Antineutrophil cytoplasmic antibodies were positive with a perinuclear staining pattern and target specificity for leucocyte myeloperoxidase (antimyeloperoxidase). Despite treatment, the kidney function did not show significant improvement. The forensic implication of this case is that even if the toxicological values are not high enough to suggest a lethal intoxication, an idiosyncratic reaction on cocaine and/or levamisole has to be taken into account.


Assuntos
Transtornos Relacionados ao Uso de Cocaína/complicações , Glomerulonefrite/diagnóstico , Anticorpos Anticitoplasma de Neutrófilos/sangue , Cocaína/química , Contaminação de Medicamentos , Glomerulonefrite/imunologia , Humanos , Levamisol/efeitos adversos , Levamisol/análise , Masculino , Insuficiência Renal Crônica/etiologia , Adulto Jovem
3.
Am J Ophthalmol ; 185: 43-47, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29103959

RESUMO

PURPOSE: To investigate the success and failure rates of scleral lens correction in severe keratoconus. DESIGN: Retrospective case series. METHODS: Study population comprised patients with keratoconus who attended the keratoconus clinic at the Antwerp University Hospital, Belgium, between January 1, 2010, and December 31, 2014. The included eyes had maximal keratometry values ≥ 70 diopters, as measured using the sagittal curvature map that was obtained by Scheimpflug tomography. The exclusion criteria included amblyopia, mental retardation, and concomitant ocular disease that limited their visual potential. RESULTS: Scleral lens fitting was proposed for the 75 eyes included in the study. Eight eyes underwent transplant surgery because of insufficient visual acuity with the lenses, lens intolerance, and issues with handling the lenses. Twelve eyes did not have lenses fitted because of good visual acuity in the other eye or a contraindication for lens wear. Three eyes were successfully fitted with corneal or hybrid lens wear. Scleral lenses were prescribed in 51 of 75 eyes. The mean gain in visual acuity (lens vs spectacle-corrected visual acuity) was 0.54 ± 0.18 (decimal fraction, Snellen eye chart). Seven eyes were lost to follow-up, 4 eyes abandoned wearing the scleral lens because of an inability to handle the lenses, and 40 eyes wore the lenses at their last follow-up visit, with a mean follow-up interval of 30.15 ± 12.83 months. CONCLUSIONS: Forty of the 51 eyes with severe keratoconus that would otherwise have undergone transplant surgery were successfully treated with long-term scleral lens wear. In this way, the indication for keratoplasty was more than halved in our keratoconus population.


Assuntos
Lentes de Contato , Topografia da Córnea , Ceratocone/cirurgia , Ceratoplastia Penetrante/métodos , Refração Ocular/fisiologia , Acuidade Visual , Adulto , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Esclera , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...