Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38716761

RESUMO

The multimodal analgesia strategy for acute pain involves using 2 or more analgesic medications with distinct mechanisms of action. This study assessed the bioavailability and tolerability of 2 tramadol hydrochloride (50 mg)/diclofenac sodium (50 mg) fixed-dose combination formulations under fed conditions to attend the Brazilian regulatory requirements for generic product registration. An open-label, randomized, single-dose, 2-period, 2-way crossover trial was conducted, including healthy subjects of both sexes. Subjects received a single dose of either the test or reference formulation of tramadol/diclofenac fixed-dose combination tablets with a 7-day washout period. Blood samples were collected up to 36 hours after dosing for tramadol and 12 hours for diclofenac and quantified using a validated liquid chromatography-tandem mass spectrometry method. Of 56 subjects enrolled, 53 completed the study. The 90% confidence intervals for maximum plasma concentration and area under the concentration-time curve from time 0 to the last quantifiable concentration were within acceptable bioequivalence limits of 80%-125%. Considering the results presented in this study, the test formulation is bioequivalent to the reference formulation and could be interchangeable in medical practice.

2.
Pharmaceutics ; 15(11)2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-38004548

RESUMO

Etoricoxib is a non-steroidal anti-inflammatory drug with high selectivity for cyclooxygenase 2 (COX-2), exerting a pronounced anti-inflammatory effect with fewer adverse events when compared to COX-1 inhibitors. The present study aimed to evaluate the bioequivalence between two etoricoxib-coated tablet formulations to meet regulatory requirements for a branded generic product registration in Brazil. A crossover study with an open-label, randomized design and a single-dose regimen with two treatments and two periods was conducted on healthy Brazilians of both genders. Subjects randomly received a single dose of a 90 mg etoricoxib coated tablet of test product Xumer® 90 mg (Adium S.A.) and the reference product Arcoxia® 90 mg (Merck Sharp & Dohme Farmacêutica Ltda.) under fasting conditions separated by a 14-day period. Blood samples were collected sequentially for up to 96 h following drug administration, and the concentrations of etoricoxib in plasma were determined using a validated UPLC-MS/MS method. Pharmacokinetic parameters were computed utilizing non-compartmental analysis methods. A total of 32 healthy subjects were enrolled, and 25 subjects completed the study. Geometric mean ratios (90% confidence intervals) for Cmax, AUC0-t, and AUC0-inf were 103.98% (95.63-113.06), 96.82% (91.82-102.09), and 95.79% (90.70-101.16), respectively. In accordance with regulatory standards, the test formulation (Xumer® 90 mg) has been deemed bioequivalent to the reference product (Arcoxia® 90 mg). As a result, these formulations can be considered interchangeable in clinical practice, with both proving to be safe and well-tolerated. The need for in vivo testing for the Xumer® 60 mg strength was waived due to the proportional similarity of the formulations and the similar in vitro dissolution profiles observed across the various strengths.

3.
Pharmaceutics ; 15(6)2023 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-37376185

RESUMO

Methylphenidate hydrochloride is used to treat children, adolescents, and adults with attention deficit/hyperactivity disorder (ADHD). Multiphasic release formulation has been used to control drug levels, mainly during children's school period. This study aimed to evaluate the bioequivalence between two methylphenidate hydrochloride extended-release tablets to meet regulatory requirements for registration in Brazil. Two independent studies (under fasting and fed conditions) designed as open-label, randomized, single-dose, two-period, two-way crossover trials were conducted in healthy subjects of both genders. Subjects were enrolled and randomly received a single dose of the test formulation methylphenidate hydrochloride 54 mg extended-release tablet (Consiv®, Adium S.A., São Paulo, Brazil) or the reference formulation (Concerta®, Janssen-Cilag Farmacêutica Ltd., São Paulo, Brazil), in each period, with a 7-day washout interval. Serial blood samples were collected up to 24 h post dose and methylphenidate plasma concentrations were obtained using a validated LC-MS/MS method. A total of 96 healthy subjects were enrolled in the fasting study, of which 80 completed the study. For the fed study, 52 healthy subjects were enrolled, and 46 subjects completed it. In both studies, 90% confidence intervals for Cmax, AUC0-t, AUC0-inf, and partial AUCs were within the acceptable limits of 80.00 to 125.00%. Thus, according to regulatory requirements, the test formulation (Consiv®) was considered to be bioequivalent to the reference formulation (Concerta®) in both conditions (fasting and fed) and, therefore, it can be considered interchangeable in clinical practice. Both formulations were safe and well tolerated in single-dose administration.

4.
Biomed Chromatogr ; 31(5)2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27809345

RESUMO

Systemic arterial hypertension is a major risk factor for cerebrovascular disease. Therefore, adequate control of blood pressure is of enormous importance. One of the many fixed-dose single-pill antihypertensive formulations available on the market is the combination of nebivolol and hydrochlorothiazide. The objective of this study was to develop two distinct high-performance liquid chromatography coupled to tandem mass spectrometry methods to simultaneously quantify nebivolol and hydrochlorothiazide in human plasma. The methods were employed in a bioequivalence study, the first assay involving a nebivolol fixed-dose single-pill formulation based on healthy Brazilian volunteers. Nebilet HCT™ (nebivolol 5 mg + hydrochlorothiazide 12.5 mg tablet, manufactured by Menarini) was the test formulation. The reference formulations were Nebilet™ (nebivolol 5 mg tablet, manufactured by Menarini) and Clorana™ (hydrochlorothiazide 25 mg tablet, manufactured by Sanofi). For both analytes, liquid-liquid extraction was employed for sample preparation and the chromatographic run time was 3.5 min. The limits of quantification validated were 0.02 ng/mL for nebivolol and 1 ng/mL for hydrochlorothiazide. Since the 90% CI for Cmax , AUC(0-last) and AUC(0-inf) individual test/reference ratios were within the 80-125% interval indicative of bioequivalence, it was concluded that Nebilet HCT™ is bioequivalent to Nebilet™ and Clorana™.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Hidroclorotiazida/farmacocinética , Nebivolol/farmacocinética , Espectrometria de Massas em Tandem/métodos , Adulto , Área Sob a Curva , Calibragem , Cromatografia Líquida de Alta Pressão/normas , Estudos Cross-Over , Combinação de Medicamentos , Feminino , Voluntários Saudáveis , Humanos , Hidroclorotiazida/sangue , Masculino , Pessoa de Meia-Idade , Nebivolol/sangue , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/normas , Equivalência Terapêutica , Tramadol/sangue
5.
Artigo em Inglês | MEDLINE | ID: mdl-25146447

RESUMO

UNLABELLED: A rapid, sensitive and specific method for quantifying propylthiouracil in human plasma using methylthiouracil as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using an organic solvent (ethyl acetate). The extracts were analyzed by high performance liquid chromatography coupled with electrospray tandem mass spectrometry (HPLC-MS/MS) in negative mode (ES-). Chromatography was performed using a Phenomenex Gemini C18 5µm analytical column (4.6mm×150mm i.d.) and a mobile phase consisting of methanol/water/acetonitrile (40/40/20, v/v/v)+0.1% of formic acid. For propylthiouracil and I.S., the optimized parameters of the declustering potential, collision energy and collision exit potential were -60 (V), -26 (eV) and -5 (V), respectively. The method had a chromatographic run time of 2.5min and a linear calibration curve over the range 20-5000ng/mL. The limit of quantification was 20ng/mL. The stability tests indicated no significant degradation. This HPLC-MS/MS procedure was used to assess the bioequivalence of two propylthiouracil 100mg tablet formulations in healthy volunteers of both sexes in fasted and fed state. The geometric mean and 90% confidence interval CI of Test/Reference percent ratios were, without and with food, respectively: 109.28% (103.63-115.25%) and 115.60% (109.03-122.58%) for Cmax, 103.31% (100.74-105.96%) and 103.40% (101.03-105.84) for AUClast. CONCLUSION: This method offers advantages over those previously reported, in terms of both a simple liquid-liquid extraction without clean-up procedures, as well as a faster run time (2.5min). The LOQ of 20ng/mL is well suited for pharmacokinetic studies. The assay performance results indicate that the method is precise and accurate enough for the routine determination of the propylthiouracil in human plasma. The test formulation with and without food was bioequivalent to reference formulation. Food administration increased the Tmax and decreased the bioavailability (Cmax and AUC).


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Propiltiouracila/sangue , Espectrometria de Massas em Tandem/métodos , Adolescente , Adulto , Estudos Cross-Over , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Propiltiouracila/química , Propiltiouracila/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray/métodos , Equivalência Terapêutica , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...