Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
1.
Clin Chem ; 70(4): 669-679, 2024 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-38385453

RESUMO

BACKGROUND: The harmonization status of most tumor markers (TMs) is unknown. We report a feasibility study performed to determine whether external quality assessment (EQA) programs can be used to obtain insights into the current harmonization status of the tumor markers α-fetoprotein (AFP), prostate specific antigen (PSA), carcinoembryonic antigen (CEA), cancer antigen (CA)125, CA15-3 and CA19-9. METHODS: EQA sample results provided by 6 EQA providers (INSTAND [Germany], Korean Association of External Quality Assessment Service [KEQAS, South Korea], National Center for Clinical Laboratories [NCCL, China], United Kingdom National External Quality Assessment Service [UK NEQAS, United Kingdom], Stichting Kwaliteitsbewaking Medische Laboratoriumdiagnostiek [SKML, the Netherlands], and the Royal College of Pathologists of Australasia Quality Assurance Programs [RCPAQAP, Australia]) between 2020 and 2021 were used. The consensus means, calculated from the measurement procedures present in all EQA programs (Abbott Alinity, Beckman Coulter DxI, Roche Cobas, and Siemens Atellica), was used as reference values. Per measurement procedure, the relative difference between consensus mean for each EQA sample and the mean of all patient-pool-based EQA samples were calculated and compared to minimum, desirable, and optimal allowable bias criteria based on biological variation. RESULTS: Between 19040 (CA15-3) and 25398 (PSA) individual results and 56 (PSA) to 76 (AFP) unique EQA samples were included in the final analysis. The mean differences with the consensus mean of patient-pool-based EQA samples for all measurement procedures were within the optimum bias criterion for AFP, the desirable bias for PSA, and the minimum bias criterion for CEA. However, CEA results <8 µg/L exceeded the minimum bias criterion. For CA125, CA15-3, and CA19-9, the harmonization status was outside the minimum bias criterion, with systematic differences identified. CONCLUSIONS: This study provides relevant information about the current harmonization status of 6 tumor markers. A pilot harmonization investigation for CEA, CA125, CA15-3, and CA19-9 would be desirable.


Assuntos
Biomarcadores Tumorais , Antígeno Carcinoembrionário , Masculino , Humanos , alfa-Fetoproteínas/análise , Antígeno Prostático Específico , Antígeno CA-19-9 , Estudos de Viabilidade , Mucina-1 , Antígeno Ca-125
2.
Clin Chem Lab Med ; 62(5): 824-829, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38295422

RESUMO

Thyroid-stimulating hormone (TSH) is an important clinical marker in the diagnosis and management of thyroid disease. TSH measurements are reported in milli-International Units per Litre (mIU/L), traceable to a World Health Organisation (WHO) reference material. There is a wide variety of commercial immunoassays for TSH measurements available, which have historically been poorly harmonised due to a lack of commutability of the WHO reference materials with patient samples. This led to the recent development of a serum-based reference panel for TSH, traceable to the WHO reference material, available via the International Federation for Clinical Chemistry and Laboratory Medicine (IFCC), aimed at harmonisation of TSH immunoassays. This report describes recent developments in the TSH reference system, including establishment of the 4th WHO International Standard for TSH, and aims to clarify the relationship between the available reference materials and their intended uses. This 4th WHO IS is widely available and defines the unit of TSH activity, therefore its continued existence is of paramount importance, however it continues to show a lack of commutability with patient in many TSH immunoassays. This makes the C-STFT TSH panel, albeit available in restricted numbers, a critical resource to ensure better TSH assay harmonisation.


Assuntos
Doenças da Glândula Tireoide , Tireotropina , Humanos , Padrões de Referência , Química Clínica , Imunoensaio , Valores de Referência
3.
J Mass Spectrom Adv Clin Lab ; 29: 9-15, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37449264

RESUMO

Background: Free thyroxine (FT4) measurement is one of the most requested tests in patient care for diagnosing and treating thyroid-related illnesses. Equilibrium dialysis (ED) is considered the "gold standard" for FT4 measurement; however, several factors have a profound effect on the reliability of FT4 assays and require special consideration. Methods: In the current study, we focused on evaluating critical factors that could contribute to reporting errors, such as adsorption of thyroxine (T4) to labware surfaces, stability of serum samples, stock solutions, and calibrator storage conditions, as well as the solvents used to prepare T4 solutions. Results: The adsorption of T4 in ethanolic solutions and dialysates to labware surfaces can be reduced with the careful selection of pipette tips, test tubes, and 96-well plates. Adding pH modifiers to neat T4 solutions can improve its stability. FT4 in serum samples remains stable after exposure to four freeze-thaw cycles, 5 °C for 18-20 h, or -70 °C for a minimum of three years. Conclusion: The presented study has demonstrated that the loss of analyte due to pre-analytical and analytical factors during operation of the FT4 reference measurement procedure (RMP) can be minimized by careful selection of all labware for sample preparation. It was found that the accuracy and imprecision of FT4 assays can be influenced by different types of dialysis devices, but acceptable alternatives to ED membranes were identified. This study demonstrates approaches to establish a FT4 method that is independent from specific suppliers and addresses critical pre-analytical and analytical factors important for FT4 measurements.

4.
Clin Chem Lab Med ; 61(10): 1719-1729, 2023 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-37071928

RESUMO

OBJECTIVES: The clinical use of soluble transferrin receptor (sTfR) as an iron status indicator is hindered by a lack of assay standardization and common reference ranges and decision thresholds. In 2009, the WHO and National Institute for Biological Standards and Controls (NIBSC) released a sTfR reference material (RM), 07/202, for assay standardization; however, a comprehensive, formal commutability study was not conducted. METHODS: This study evaluated the commutability of WHO 07/202 sTfR RM and human serum pools and the impacts of their use as common calibrators. Commutability was assessed for six different measurement procedures (MPs). Serum pools were prepared according to updated CLSI C37-A procedures (C37) or non-C37 procedures. The study design and analyses were based on Parts 2 and 3 of the 2018 IFCC Commutability in Metrological Traceability Working Group's Recommendations for Commutability Assessment. WHO 07/202 and serum pools were used for instrument/assay and mathematical recalibration, respectively, to determine if their use decreases inter-assay measurement variability for clinical samples. RESULTS: The WHO 07/202 RM dilutions were commutable for all 6 MPs assessed and, when used for instrument calibration, decreased inter-assay variability from 208 to 55.7 %. Non-C37 and C37 serum pools were commutable for all 6 MPs assessed and decreased inter-assay variability from 208 to 13.8 % and 4.6 %, respectively, when used for mathematical recalibration. CONCLUSIONS: All materials evaluated, when used as common calibrators, substantially decreased inter-assay sTfR measurement variability. MP calibration to non-C37 and C37 serum pools may reduce the sTfR IMPBR to a greater extent than WHO 07/202 RM.


Assuntos
Receptores da Transferrina , Soro , Humanos , Padrões de Referência , Calibragem , Organização Mundial da Saúde
5.
Clin Chem Lab Med ; 61(9): 1605-1611, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-36994743

RESUMO

OBJECTIVES: Free thyroxine (FT4) in serum is routinely measured in clinical practice to diagnose and monitor thyroid disease. Due to its concentration in picomolar range and the delicate equilibrium of free and protein-bound T4, accurate measurement is challenging. As a consequence, large inter-method differences in FT4 results exists. Optimal method design and standardization of the FT4 measurement is therefore necessary. The IFCC Working Group for Standardization of Thyroid Function Tests proposed a reference system with a conventional reference measurement procedure (cRMP) for FT4 in serum. In this study, we describe our FT4 candidate cRMP and its validation in clinical samples. METHODS: This candidate cRMP is based on equilibrium dialysis (ED) combined with determination of T4 with an isotope-dilution liquid chromatography tandem mass-spectrometry (ID-LC-MS/MS) procedure and was developed according to the endorsed conventions. Its accuracy, reliability, and comparability was investigated using human sera. RESULTS: It was shown that the candidate cRMP adhered to the conventions and its accuracy, precision, and robustness were adequate in serum of healthy volunteers. CONCLUSIONS: Our candidate cRMP measures FT4 accurately and performs well in serum matrix.


Assuntos
Espectrometria de Massas em Tandem , Tiroxina , Humanos , Cromatografia Líquida/métodos , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos , Diálise Renal , Isótopos , Padrões de Referência
6.
Clin Biochem ; 116: 42-51, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36940844

RESUMO

BACKGROUND: Accurate and reliable measurement of human serum free thyroxine (FT4) is critical for the diagnosis and treatment of thyroid diseases. However, concerns have been raised regarding the performance of FT4 measurements in patient care. Centers for Disease Control and Prevention Clinical Standardization Programs (CDC-CSP) address these concerns by creating a FT4 standardization program to standardize FT4 measurements. The study aims to develop a highly accurate and precise candidate Reference Measurement Procedure (cRMP), as one key component of CDC-CSP, for standardization of FT4 measurements. METHODS: Serum FT4 was separated from protein-bound thyroxine with equilibrium dialysis (ED) following the recommended conditions in the Clinical and Laboratory Standards Institute C45-A guideline and the published RMP [20,21,23]. FT4 in dialysate was directly quantified with liquid chromatography-tandem mass spectrometry (LC-MS/MS) without derivatization. Gravimetric measurements of specimens and calibrator solutions, calibrator bracketing, isotope dilution, enhanced chromatographic resolution, and T4 specific mass transitions were used to ensure the accuracy, precision, and specificity of the cRMP. RESULTS: The described cRMP agreed well with the established RMP and two other cRMPs in an interlaboratory comparison study. The mean biases of each method to the overall laboratory mean were within ±2.5%. The intra-day, inter-day, and total imprecision for the cRMP were within 4.4%. The limit of detection was 0.90 pmol/L, which was sufficiently sensitive to determine FT4 for patients with hypothyroidism. The structural analogs of T4 and endogenous components in dialysate did not interfere with the measurements. CONCLUSION: Our ED-LC-MS/MS cRMP provides high accuracy, precision, specificity, and sensitivity for FT4 measurement. The cRMP can serve as a higher-order standard for establishing measurement traceability and provide an accuracy base for the standardization of FT4 assays.


Assuntos
Espectrometria de Massas em Tandem , Tiroxina , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Diálise Renal , Soluções para Diálise , Padrões de Referência
7.
Clin Chem ; 69(3): 251-261, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36644914

RESUMO

BACKGROUND: Medical results generated by European CE Marking for In Vitro Diagnostic or in-house tests should be traceable to higher order reference measurement systems (RMS), such as International Federation of Clinical Chemistry and Laboratory Medicine (IFCC)-endorsed reference measurement procedures (RMPs) and reference materials. Currently, serum apolipoprotein (a) [apo(a)] is recognized as a novel risk factor for cardiovascular risk assessment and patient management. The former RMS for serum apo(a) is no longer available; consequently, an International System of Units (SI)-traceable, ideally multiplexed, and sustainable RMS for apo(a) is needed. METHODS: A mass spectrometry (MS)-based candidate RMP (cRMP) for apo(a) was developed using quantitative bottom-up proteomics targeting 3 proteotypic peptides. The method was provisionally validated according to ISO 15193 using a single human serum based calibrator traceable to the former WHO-IFCC RMS. RESULTS: The quantitation of serum apo(a) was by design independent of its size polymorphism, was linear from 3.8 to 456 nmol/L, and had a lower limit of quantitation for apo(a) of 3.8 nmol/L using peptide LFLEPTQADIALLK. Interpeptide agreement showed Pearson Rs of 0.987 and 0.984 for peptides GISSTVTGR and TPENYPNAGLTR, and method comparison indicated good correspondence (slopes 0.977, 1.033, and 1.085 for LFLEPTQADIALLK, GISSTVTGR, and TPENYPNAGLTR). Average within-laboratory imprecision of the cRMP was 8.9%, 11.9%, and 12.8% for the 3 peptides. CONCLUSIONS: A robust, antibody-independent, MS-based cRMP was developed as higher order RMP and an essential part of the apo(a) traceability chain and future RMS. The cRMP fulfils predefined analytical performance specifications, making it a promising RMP candidate in an SI-traceable MS-based RMS for apo(a).


Assuntos
Peptídeos , Soro , Humanos , Apoproteína(a) , Espectrometria de Massas , Padrões de Referência , Calibragem
8.
Clin Chem ; 69(3): 262-272, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36644921

RESUMO

BACKGROUND: Elevated concentrations of lipoprotein(a) [Lp(a)] are directly related to an increased risk of cardiovascular diseases, making it a relevant biomarker for clinical risk assessment. However, the lack of global standardization of current Lp(a) measurement procedures (MPs) leads to inconsistent patient care. The International Federation for Clinical Chemistry and Laboratory Medicine working group on quantitating apolipoproteins by mass spectrometry (MS) aims to develop a next-generation SI (International system of units)-traceable reference measurement system consisting of a MS-based, peptide-calibrated reference measurement procedure (RMP) and secondary serum-based reference materials (RMs) certified for their apolipoprotein(a) [apo(a)] content. To reach measurement standardization through this new measurement system, 2 essential requirements need to be fulfilled: a sufficient correlation among the MPs and appropriate commutability of future serum-based RMs. METHODS: The correlation among the candidate RMP (cRMP) and immunoassay-based MPs was assessed by measuring a panel of 39 clinical samples (CS). In addition, the commutability of 14 different candidate RMs was investigated. RESULTS: Results of the immunoassay-based MPs and the cRMPs demonstrated good linear correlations for the CS but some significant sample-specific differences were also observed. The results of the commutability study show that RMs based on unspiked human serum pools can be commutable with CS, whereas human pools spiked with recombinant apo(a) show different behavior compared to CS. CONCLUSIONS: The results of this study show that unspiked human serum pools are the preferred candidate secondary RMs in the future SI-traceable Lp(a) Reference Measurement System.


Assuntos
Química Clínica , Lipoproteína(a) , Humanos , Imunoensaio , Espectrometria de Massas , Padrões de Referência
10.
JAMA Pediatr ; 176(7): 699-714, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35467725

RESUMO

Importance: Appropriately established pediatric reference intervals are critical to the clinical decision-making process and should reflect the physiologic changes that occur during healthy child development. Reference intervals used in pediatric care today remain highly inconsistent across a broad range of common clinical biomarkers. Observations: This narrative review assesses biomarker-specific pediatric reference intervals and their clinical utility with respect to the underlying biological changes occurring during development. Pediatric reference intervals from PubMed-indexed articles published from January 2015 to April 2021, commercial laboratory websites, study cohorts, and pediatric reference interval books were all examined. Although large numbers of pediatric reference intervals are published for some biomarkers, very few are used by clinical and commercial laboratories. The patterns, extent, and timing of biomarker changes are highly variable, particularly during developmental stages with rapid physiologic changes. However, many pediatric reference intervals do not capture these changes and thus do not accurately reflect the underlying biochemistry of development, resulting in significant inconsistencies between reference intervals. Conclusions and Relevance: There is a need to correctly describe the biochemistry of child development as well as to identify strategies to develop accurate and consistent pediatric reference intervals for improved pediatric care.


Assuntos
Família , Biomarcadores , Criança , Tomada de Decisão Clínica , Humanos , Valores de Referência
11.
J Am Soc Nephrol ; 33(8): 1448-1458, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35396262

RESUMO

Full-length parathyroid hormone (PTH 1-84) is crucial for the regulation of calcium and phosphate homeostasis and bone remodeling. PTH 1-84 is metabolized into various PTH fragments, which are measured with varying levels of efficiency by PTH immunoassays. These PTH fragments, which increase in serum as CKD progresses, could potentially modulate the effects of PTH 1-84 and contribute to CKD-associated bone disorders. To obtain a true biologic representation of total PTH bioactivity, it is necessary to measure not only PTH 1-84 but also PTH fragments that are present in circulation. Traditional second-generation PTH immunoassays collectively measure PTH 1-84, PTH fragments, and post-translationally modified PTH 1-84, making it difficult to accurately predict the character of underlying renal osteodystrophy. This review highlights current advances in methods available for PTH measurement and the clinical relevance of PTH fragments in CKD. We emphasize the usefulness of mass spectrometry as a potential reference method for PTH measurement.


Assuntos
Distúrbio Mineral e Ósseo na Doença Renal Crônica , Insuficiência Renal Crônica , Osso e Ossos , Humanos , Espectrometria de Massas , Hormônio Paratireóideo , Fragmentos de Peptídeos
12.
J Clin Lipidol ; 15(5): 629-648, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34802986

RESUMO

Lipoprotein measurements are pivotal in the management of patients at risk for atherosclerotic coronary heart disease (CHD) with myocardial infarction and coronary death as the main outcomes, and for atherosclerotic cardiovascular disease (ASCVD), which includes CHD and stroke. Recent developments and changes in guidelines affect optimization of using lipid measures as cardiovascular biomarkers. This scientific statement reviews the pre-analytical, analytical, post-analytical, and clinical aspects of lipoprotein measurements. Highlights include the following: i) It is acceptable to screen with nonfasting lipids. ii) non-high-density lipoprotein HDL-cholesterol (non-HDL-C) is measured reliably in either the fasting or the nonfasting state and can effectively guide ASCVD prevention. iii) low density lipoprotein cholesterol (LDL-C) can be estimated from total cholesterol, high density lipoprotein cholesterol (HDL-C), and triglyceride (TG) measurements. For patients with LDL-C>100 mg/dL and TG ≤150 mg/dL it is reasonable to use the Friedewald formula. However, for those with TG 150-400 mg/dL the Friedewald formula for LDL-C estimation is less accurate. The Martin/Hopkins method is recommended for LDL-C estimation throughout the range of LDL-C levels and up to TG levels of 399 mg/dL. For TG levels ≥400 mg/dL LDL-C estimating equations are currently not recommended and newer methods are being evaluated. iv) When LDL-C or TG screening results are abnormal the clinician should consider obtaining fasting lipids. v) Advanced lipoprotein tests using apolipoprotein B (apoB), LDL Particle Number (LDL-P) or remnant cholesterol may help to guide therapeutic decisions in select patients, but data are limited for patients already on lipid lowering therapy with low LDL-C levels. Better harmonization of advanced lipid measurement methods is needed. Lipid measurements are recommended 4-12 weeks after a change in lipid treatment. Lipid laboratory reports should denote desirable values and specifically identify extremely elevated LDL-C levels (≥190 mg/dL at any age or ≥160 mg/dL in children) as severe hypercholesterolemia. Potentially actionable abnormal lipid test results, including fasting triglycerides (TG) ≥500 mg/dL, should be reported as hypertriglyceridemia. Appropriate use and reporting of lipid tests should improve their utility in the management of persons at high risk for ASCVD events.


Assuntos
HDL-Colesterol/sangue , LDL-Colesterol/sangue , Doença da Artéria Coronariana/diagnóstico , Transtornos do Metabolismo dos Lipídeos , Sociedades Médicas/organização & administração , Biomarcadores/sangue , Doença da Artéria Coronariana/prevenção & controle , Feminino , Fatores de Risco de Doenças Cardíacas , Humanos , Hipercolesterolemia/diagnóstico , Masculino , Guias de Prática Clínica como Assunto
13.
Clin Chem ; 67(12): 1590-1605, 2021 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-34633037

RESUMO

BACKGROUND: The JCTLM created a Task Force on Reference Measurement System Implementation (TF-RMSI) to provide guidance on metrological traceability implementation for the in vitro diagnostics (IVD) community. CONTENT: TF-RMSI investigated the reference measurement systems (RMS) for 13 common measurands by applying the following procedural steps: (a) extracting data from the JCTLM database of available certified reference materials (CRMs) and reference measurement procedures (RMPs); (b) describing the RMS to which each recruited CRM or RMP belongs; (c) identifying the intended use of the CRMs, and, if used as a common calibrator for IVD measuring systems and/or trueness assessment of field methods was included, checking the CRM's certificate for information about commutability with clinical samples; and (d) checking if the CRM or RMP measurement uncertainty (MU) has the potential to be small enough to avoid significantly affecting the analytical performance specifications (APS) for MU of clinical sample results when the MU from the IVD calibrator and from the end-user measuring system were combined. SUMMARY: We produced a synopsis of JCTLM-listed higher-order CRMs and RMPs for the selected measurands, including their main characteristics for implementing traceability and fulfilling (or not) the APS for suitable MU. Results showed that traceability to higher-order references can be established by IVD manufacturers within the defined APS for most of the 13 selected measurands. However, some measurands do not yet have suitable CRMs for use as common calibrators. For these measurands, splitting clinical samples with a laboratory performing the RMP may provide a practical alternative for establishing a calibration hierarchy.


Assuntos
Laboratórios , Calibragem , Bases de Dados Factuais , Humanos , Padrões de Referência , Incerteza
14.
Curr Dev Nutr ; 5(5): nzab063, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34027294

RESUMO

BACKGROUND: Intake of trans fatty acids (TFAs) increases LDL cholesterol, decreases HDL cholesterol, and increases the risk of heart disease morbidity and mortality. Many food products potentially contain industrially produced or ruminant TFAs. However, little is known about the dietary sources of plasma TFA concentrations. OBJECTIVE: The objective of this study was to examine associations between foods consumed and plasma TFA concentrations using 24-h dietary recall data and plasma TFA measures among adults aged ≥20 y who participated in the NHANES 2009-2010 in the United States. METHODS: Over 4400 food products in the dietary interview data were categorized into 32 food and beverage groups/subgroups. Four major plasma TFAs (palmitelaidic acid, elaidic acid, vaccenic acid, linolelaidic acid) and the sum of the 4 TFAs (sumTFAs) were analyzed using GC-MS. Multivariable linear regression analyses were conducted to identify associations of plasma TFAs with all 32 food and beverage groups/subgroups, controlling for the potential confounding effects of 11 demographic, socioeconomic, behavioral, lifestyle, and health-related variables. RESULTS: Consumption of the following food groups/subgroups was significantly associated with elevated plasma TFA concentrations: cream substitutes (P < 0.001 for palmitelaidic acid, elaidic acid, vaccenic acid, and sumTFAs); cakes, cookies, pastries, and pies (P < 0.001 for elaidic acid, vaccenic acid, and sumTFAs; P < 0.05 for linolelaidic acid); milk and milk desserts (P < 0.01 for palmitelaidic acid and vaccenic acid; P < 0.05 for linolelaidic acid and sumTFAs); beef/veal, lamb/goat, and venison/deer (P < 0.01 for vaccenic acid; P < 0.05 for sumTFAs); and butters (P < 0.001 for palmitelaidic acid and vaccenic acid; P < 0.05 for sumTFAs). CONCLUSIONS: The findings suggest that the above 5 food groups/subgroups could be the main dietary sources of plasma TFAs among adults in the United States in 2009-2010.

15.
J Clin Endocrinol Metab ; 106(9): 2635-2645, 2021 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-34013335

RESUMO

CONTEXT: Soy formula feeding is common in infancy and is a source of high exposure to phytoestrogens, documented to influence vaginal cytology in female infants. Its influence on minipuberty in males has not been established. OBJECTIVE: To assess the association between infant feeding practice and longitudinally measured reproductive hormones and hormone-responsive tissues in infant boys. METHODS: The Infant Feeding and Early Development study was a prospective cohort of maternal-infant dyads requiring exclusive soy formula, cow milk formula, or breast milk feeding during study follow-up. In the 147 infant boy participants, serum testosterone, luteinizing hormone, stretched penile length, anogenital distance, and testis volume were longitudinally assessed from birth to 28 weeks. We examined feeding-group differences in age trajectories for these outcomes using mixed-effects regression splines. RESULTS: Median serum testosterone was at pubertal levels at 2 weeks (176 ng/dL [quartiles: 124, 232]) and remained in this range until 12 weeks in all feeding groups. We did not observe differences in trajectories of hormone concentrations or anatomical measures between boys fed soy formula (n = 55) and boys fed cow milk formula (n = 54). Compared with breastfed boys (n = 38), soy formula-fed boys had a more rapid increase in penile length (P = .004) and slower initial lengthening of anogenital distance (P = .03), but no differences in hormone trajectories. CONCLUSION: Reproductive hormone concentrations and anatomical responses followed similar trajectories in soy and cow milk formula-fed infant boys. Our findings suggest that these measures of early male reproductive development do not respond to phytoestrogen exposure during infancy.


Assuntos
Genitália Masculina/anatomia & histologia , Glycine max , Fórmulas Infantis , Fitoestrógenos/farmacologia , Testosterona/sangue , Adulto , Aleitamento Materno , Feminino , Humanos , Lactente , Hormônio Luteinizante/sangue , Masculino , Pênis/anatomia & histologia , Pênis/crescimento & desenvolvimento , Estudos Prospectivos , Testículo/anatomia & histologia
16.
Environ Health ; 20(1): 35, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33794901

RESUMO

BACKGROUND: Up to now, 3 epidemiological studies have shown clear inverse associations between prenatal acrylamide exposure and birth size. In addition to studying the association between acrylamide and birth size, we investigated the interaction between acrylamide and polymorphisms in acrylamide-metabolising genes, with the aim of probing the causality of the inverse relationship between acrylamide and fetal growth. METHODS: We investigated the association between prenatal acrylamide exposure (acrylamide and glycidamide hemoglobin adduct levels (AA-Hb and GA-Hb) in cord blood) and birth weight, length and head circumference in 443 newborns of the ENVIRONAGE (ENVIRonmental influence ON AGEing in early life) birth cohort. In addition, we studied interaction with single nucleotide polymorphisms (SNPs) in CYP2E1, EPHX1 and GSTP1, using multiple linear regression analysis. RESULTS: Among all neonates, the body weight, length and head circumference of neonates in the highest quartile was - 101 g (95% CI: - 208, 7; p for trend = 0.12), - 0.13 cm (95% CI: - 0.62, 0.36; p for trend = 0.69) and - 0.41 cm (- 0.80, - 0.01; p for trend = 0.06) lower, respectively, compared to neonates in the lowest quartile of AA-Hb in cord blood, For GA-Hb, the corresponding effect estimates were - 222 g (95% CI: - 337, - 108; p for trend = 0.001), - 0.85 (95% CI: - 1.38, - 0.33; p for trend = 0.02) and - 0.55 (95% CI: - 0.98, - 0.11; p for trend = 0.01), respectively. The associations for GA-Hb were similar or stronger in newborns of non-smoking mothers. There was no statistically significant interaction between acrylamide exposure and the studied genetic variations but there was a trend of stronger inverse associations with birth weight and head circumference among newborns with homozygous wildtypes alleles for the CYP2E1 SNPS and with variant alleles for a GSTP1 SNP (rs1138272). CONCLUSIONS: Prenatal dietary acrylamide exposure, specifically in the form of its metabolite glycidamide, was inversely associated with birth weight, length and head circumference. The interaction pattern with SNPs in CYP2E1, although not statistically significant, is an indication for the causality of this association. Other studies are needed to corroborate this finding.


Assuntos
Acrilamida/sangue , Peso ao Nascer , Citocromo P-450 CYP2E1/genética , Epóxido Hidrolases/genética , Sangue Fetal/metabolismo , Glutationa S-Transferase pi/genética , Exposição Materna , Troca Materno-Fetal , Acrilamida/metabolismo , Adulto , Compostos de Epóxi/metabolismo , Feminino , Hemoglobinas/metabolismo , Humanos , Recém-Nascido , Masculino , Polimorfismo de Nucleotídeo Único , Gravidez
17.
Clin Chem ; 67(6): 843-853, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33693557

RESUMO

BACKGROUND: The precise concentrations of full-length parathyroid hormone (PTH1-84) and the identity and concentrations of PTH fragments in patients with various stages of chronic renal failure are unknown. METHODS: We developed a liquid chromatography-high resolution mass spectrometry (LC-HRMS) method to characterize and quantify PTH1-84 and PTH fragments in serum of 221 patients with progressive renal dysfunction. Following capture by matrix-bound amino-terminal or carboxyl-terminal region-specific antibodies and elution from matrix, PTH1-84 and PTH fragments were identified and quantitated using LC-HRMS. PTH was simultaneously measured using an intact PTH (iPTH) immunoassay. RESULTS: Full-length PTH1-84 and 8 PTH fragments (PTH28-84, 34-77, 34-84, 37-77, 37-84, 38-77, 38-84, and 45-84) were unequivocally identified and were shown to increase significantly when an eGFR declined to ≤17-23 mL/min/1.73m2. Serum concentrations of PTH1-84 were similar when measured by LC-HRMS following capture by amino-terminal or carboxyl-terminal immunocapture methods. In patients with an eGFR of <30 mL/min/1.73 m2, serum PTH concentrations measured using LC-HRMS were significantly lower than PTH measured using an iPTH immunoassay. PTH7-84 and oxidized forms of PTH1-84 were below the limit of detection (30 and 50 pg/mL, respectively). CONCLUSIONS: LC-HRMS identifies circulating PTH1-84, carboxyl-terminal PTH fragments, and mid-region PTH fragments, in patients with progressive renal failure. Serum PTH1-84 and its fragments markedly rise when an eGFR decreases to ≤17-23 mL/min/1.73 m2. PTH concentrations measured using LC-HRMS tend to be lower than those measured using an iPTH immunoassay, particularly in severe chronic renal failure. Our data do not support the existence of circulating PTH7-84 and oxidized PTH1-84.


Assuntos
Falência Renal Crônica , Hormônio Paratireóideo , Cromatografia Líquida , Receptores ErbB/química , Receptores ErbB/metabolismo , Humanos , Espectrometria de Massas , Fragmentos de Peptídeos/química , Fragmentos de Peptídeos/metabolismo
18.
J Clin Endocrinol Metab ; 106(6): 1668-1683, 2021 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-33630047

RESUMO

CONTEXT: Epidemiologic studies have demonstrated that overweight/obese girls (OW/OB) undergo thelarche and menarche earlier than normal weight girls (NW). There have been no longitudinal studies to specifically investigate how body weight/fat affects both clinical and biochemical pubertal markers in girls. OBJECTIVE: To investigate the effect of total body fat on reproductive hormones and on the maturation of estrogen-sensitive tissues during puberty in girls. METHODS: Ninety girls (36 OW/OB, 54 NW), aged 8.2 to 14.7 years, completed 2.8 ±â€…1.7 study visits over 4 years. Visits included dual-energy x-ray absorptiometry to calculate total body fat (TBF), Tanner staging, breast ultrasound for morphological staging (BMORPH; A-E), pelvic ultrasound, hormone tests, and assessment of menarchal status. The effect of TBF on pubertal markers was determined using a mixed, multistate, or Cox proportional hazards model, controlling for baseline BMORPH. RESULTS: NW were older than OW/OB (11.3 vs 10.2 years, P < .01) at baseline and had more advanced BMORPH (P < .01). Luteinizing hormone, estradiol, and ovarian and uterine volumes increased with time with no effect of TBF. There was a time × TBF interaction for follicle-stimulating hormone, inhibin B, estrone, total and free testosterone, and androstenedione: Levels were initially similar, but after 1 year, levels increased in girls with higher TBF, plateaued in girls with midrange TBF, and decreased in girls with lower TBF. Girls with higher TBF progressed through BMORPH stage D more slowly but achieved menarche earlier than girls with lower TBF. CONCLUSION: In late puberty, girls with higher TBF demonstrate differences in standard hormonal and clinical markers of puberty. Investigation of the underlying causes and clinical consequences of these differences in girls with higher TBF deserves further study.


Assuntos
Tecido Adiposo/fisiologia , Composição Corporal/fisiologia , Puberdade/fisiologia , Absorciometria de Fóton , Adolescente , Desenvolvimento do Adolescente/fisiologia , Criança , Feminino , Humanos , Estudos Longitudinais , Menarca/fisiologia , Obesidade/metabolismo , Obesidade/fisiopatologia , Sobrepeso/metabolismo , Sobrepeso/fisiopatologia , Estados Unidos/epidemiologia
19.
Nutrients ; 13(2)2021 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-33525653

RESUMO

Currently the 25-hydroxy vitamin D (25(OH)D) concentration is thought to be the best estimate of the vitamin D status of an individual. Unfortunately, its measurement remains complex, despite recent technological advances. We evaluated the biological variation (BV) of 25(OH)D in order to set analytical performance specifications (APS) for measurement uncertainty (MU). Six European laboratories recruited 91 healthy participants. The 25(OH)D concentrations in K3-EDTA plasma were examined weekly for up to 10 weeks in duplicate on a Lumipulse G1200 (Fujirebio, Tokyo, Japan). The linear regression of the mean 25(OH)D concentrations at each blood collection showed that participants were not in a steady state. The dissection of the 10-sample collection into two subsets, namely collections 1-5 and 6-10, did not allow for correction of the lack of homogeneity: estimates of the within-subject BV ranged from 5.8% to 7.1% and the between-subject BV ranged from 25.0% to 39.2%. Methods that would differentiate a difference induced by 25(OH)D supplementation at p < 0.05 should have MU < 13.6%, while at p < 0.01, the MU should be <9.6%. The development of APS using BV assumes a steady state of patients. The findings in this study suggest that patients are not in steady state. Therefore, APS that are based on MU appear to be more appropriate.


Assuntos
Vitamina D/análogos & derivados , Coleta de Amostras Sanguíneas , Humanos , Modelos Lineares , Modelos Teóricos , Incerteza , Vitamina D/análise , Vitamina D/sangue
20.
Lipids ; 56(1): 3-16, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32519378

RESUMO

Lipidomics is a rapidly growing field, fueled by developments in analytical instrumentation and bioinformatics. To date, most researchers and industries have employed their own lipidomics workflows without a consensus on best practices. Without a community-wide consensus on best practices for the prevention of lipid degradation and transformations through sample collection and analysis, it is difficult to assess the quality of lipidomics data and hence trust results. Clinical studies often rely on samples being stored for weeks or months until they are analyzed, but inappropriate sampling techniques, storage temperatures, and analytical protocols can result in the degradation of complex lipids and the generation of oxidized or hydrolyzed metabolite artifacts. While best practices for lipid stability are sample dependent, it is generally recommended that strategies during sample preparation capable of quenching enzymatic activity and preventing oxidation should be considered. In addition, after sample preparation, lipid extracts should be stored in organic solvents with antioxidants at -20 °C or lower in an airtight container without exposure to light or oxygen. This will reduce or eliminate sublimation, and chemically and physically induced molecular transformations such as oxidation, enzymatic transformation, and photon/heat-induced degradation. This review explores the available literature on lipid stability, with a particular focus on human health and/or clinical lipidomic applications. Specifically, this includes a description of known mechanisms of lipid degradation, strategies, and considerations for lipid storage, as well as current efforts for standardization and quality insurance of protocols.


Assuntos
Lipidômica/normas , Lipídeos/normas , Animais , Humanos , Metabolismo dos Lipídeos , Lipídeos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...