Int J Comput Assist Radiol Surg ; 19(7): 1399-1407, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38780830

RESUMO

PURPOSE: Intraoperative cone-beam CT imaging enables 3D validation of implant positioning and fracture reduction for orthopedic and trauma surgeries. However, the emergence of metal artifacts, especially in the vicinity of metallic objects, severely degrades the clinical value of the imaging modality. In previous works, metal artifact avoidance (MAA) methods have been shown to reduce metal artifacts by adapting the scanning trajectory. Yet, these methods fail to translate to clinical practice due to remaining methodological constraints and missing workflow integration. METHODS: In this work, we propose a method to compute the spatial distribution and calibrated strengths of expected artifacts for a given tilted circular trajectory. By visualizing this as an overlay changing with the C-Arm's tilt, we enable the clinician to interactively choose an optimal trajectory while factoring in the procedural context and clinical task. We then evaluate this method in a realistic human cadaver study and compare the achieved image quality to acquisitions optimized using global metrics. RESULTS: We assess the effectiveness of the compared methods by evaluation of image quality gradings of depicted pedicle screws. We find that both global metrics as well as the proposed visualization of artifact distribution enable a drastic improvement compared to standard non-tilted scans. Furthermore, the novel interactive visualization yields a significant improvement in subjective image quality compared to the state-of-the-art global metrics. Additionally we show that by formulating an imaging task, the proposed method allows to selectively optimize image quality and avoid artifacts in the region of interest. CONCLUSION: We propose a method to spatially resolve predicted artifacts and provide a calibrated measure for artifact strength grading. This interactive MAA method proved practical and effective in reducing metal artifacts in the conducted cadaver study. We believe this study serves as a crucial step toward clinical application of an MAA system to improve image quality and enhance the clinical validation of implant placement.


Assuntos
Artefatos , Cadáver , Tomografia Computadorizada de Feixe Cônico , Metais , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Imageamento Tridimensional/métodos , Parafusos Pediculares
2.
Eur Spine J ; 33(6): 2304-2313, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38635086

RESUMO

BACKGROUND CONTEXT: Studies have shown biomechanical superiority of cervical pedicle screw placement over other techniques. However, accurate placement is challenging due to the inherent risk of neurovascular complications. Navigation technology based on intraoperative 3D imaging allows highly accurate screw placement, yet studies specifically investigating screw placement in patients with traumatic atlantoaxial injuries are scarce. The aim of this study was to compare atlantoaxial screw placement as treatment of traumatic instabilities using iCT-based navigation or fluoroscopic-guidance with intraoperative 3D control scans. METHODS: This was a retrospective review of patients with traumatic atlantoaxial injuries treated operatively with dorsal stabilization of C1 and C2. Patients were either assigned to the intraoperative navigation or fluoroscopic-guidance group. Screw accuracy, procedure time, and revisions were compared. RESULTS: Seventy-eight patients were included in this study with 51 patients in the navigation group and 27 patients in the fluoroscopic-guidance group. In total, 312 screws were placed in C1 and C2. Screw accuracy was high in both groups; however, pedicle perforations > 1 mm occurred significantly more often in the fluoroscopic-guidance group (P = 0.02). Procedure time was on average 23 min shorter in the navigation group (P = 0.02). CONCLUSIONS: This study contributes to the available data showing that navigated atlantoaxial screw placement proves to be feasible as well as highly accurate compared to the fluoroscopic-guidance technique without prolonging the time needed for surgery. When comparing these data with other studies, the application of different classification systems for assessment of screw accuracy should be considered.


Assuntos
Articulação Atlantoaxial , Vértebras Cervicais , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Estudos Retrospectivos , Fluoroscopia/métodos , Vértebras Cervicais/cirurgia , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/lesões , Articulação Atlantoaxial/cirurgia , Articulação Atlantoaxial/diagnóstico por imagem , Articulação Atlantoaxial/lesões , Cirurgia Assistida por Computador/métodos , Parafusos Ósseos , Parafusos Pediculares , Idoso , Traumatismos da Coluna Vertebral/cirurgia , Traumatismos da Coluna Vertebral/diagnóstico por imagem , Adulto Jovem , Resultado do Tratamento , Instabilidade Articular/cirurgia , Instabilidade Articular/diagnóstico por imagem
3.
J Clin Med ; 13(5)2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38592668

RESUMO

(1) Background: In elderly patients with type II odontoid fractures, accompanying severe atlantoaxial instability (AAI) is discussed as a marker possibly warranting more aggressive surgical therapy. This study aimed to characterize adverse events as well as the radiological and functional outcomes of surgical vs. conservative therapy in patients with odontoid fracture and AAI. (2) Methods: Patients aged 65 years and older with type II odontoid fracture and AAI treated were included. AAI was assumed if the mean subluxation across both atlantoaxial facet joints in the sagittal plane was greater than 50%. Data on demographics, comorbidities, treatment, adverse events, radiological, and functional outcomes were analyzed. (3) Results: Thirty-nine patients were included. Hospitalization time was significantly shorter in conservatively treated patients compared to patients with ventral or dorsal surgery. Adverse events occurred in 11 patients (28.2%), affecting 10 surgically treated patients (35.7%), and 1 conservatively treated patient (9.1%). Moreover, 25 patients were followed-up (64.1%). One secondary dislocation occurred in the conservative group (11.1%) and three in the surgical group (18.8%). (4) Conclusions: Despite the potential for instability in this injury, conservative treatment does not seem to lead to unfavorable short-term results, less adverse events, and a shorter hospital stay and should thus be considered and discussed with patients as a treatment option, even in the presence of severe AAI.

4.
Int J Emerg Med ; 17(1): 34, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38438968

RESUMO

BACKGROUND: Type C pelvic fractures (AO/OTA) are severe injuries that frequently lead to bleeding and hemodynamic instability. Pelvic binders play a crucial role in their initial management. Placement at the correct level in the prehospital setting is challenging. The aim of this study was to compare two pelvic binders regarding their effectiveness in reducing intrapelvic volume and increasing intrapelvic pressure in patients with type C pelvic fractures (AO/OTA) when applied at three different levels. METHODS: Rotationally and vertically unstable pelvic injuries (AO/OTA classification 61-C1.1) were produced in five fresh-frozen human cadaveric specimens. Intrapelvic volume, vesical pressure and compression pressure within the pubic symphysis and the sacroiliac joint were measured when applying a SAM Pelvic Sling II and a T-POD at the level of the greater trochanter as well as levels higher and lower than recommended. RESULTS: Comparison of the two pelvic binders positioned at the recommended level (greater trochanter) showed no significant difference in volume reduction (13.85 ± 31.37 cm3, p = 0.442), however, increase in vesical pressure was significantly higher when using the T-POD (5.80 ± 3.27 cmH2O, p = 0.017). When positioned at the level of the iliac crest, vesical pressure increase and intrapelvic volume reduction were significantly greater with the T-POD (14.00 ± 8.57 cmH2O, p = 0.022 and 10.45 ± 5.45 cm3, p = 0.031 respectively). Application of the SAM Pelvic Sling II below the greater trochanter led to a significantly greater decrease in volume (-32.26 ± 7.52 cm3, p = 0.003) than the T-POD. Comparison of the recommended attachment level with incorrect positioning led to no significant differences for the T-POD, while the SAM Pelvic Sling II achieved a significantly lower volume reduction when placed at the iliac crest (40.15 ± 14.57 cm3, p = 0.012) and a significantly lower increase in vesical pressure when applied below the greater trochanter (3.40 ± 1.52 cmH2O, p = 0.007). CONCLUSION: Direct comparison of the two pelvic binders showed that the T-POD achieved significantly greater results when applied at the recommended level and was less susceptible to incorrect positioning. These outcomes support the preferred use of the T-POD for prehospital emergency pelvic stabilisation.

5.
Brain Spine ; 4: 102769, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38510605

RESUMO

Introduction: Fractures of the thoracolumbar junction are the most common vertebral fractures and can require surgical treatment. Several studies have shown that the accuracy of pedicle screw placement can be improved by the use of 3D-navigation. Still only few studies have focused on the use of navigation in traumatic spine injuries. Research question: The aim of this study was to compare the screw placement accuracy and radiation exposure for 3D-navigated and fluoroscopy-guided percutaneous pedicle screw placement in traumatic fractures of the thoracolumbar junction. Materials and methods: In this single-center study 25 patients undergoing 3D-navigated percutaneous pedicle screw placement for traumatic fractures of the thoracolumbar junction (T12-L2) were compared to a control group of 25 patients using fluoroscopy. Screw accuracy was determined in postoperative CT-scans using the Gertzbein-Robbins classification system. Additionally, duration of surgery, dose area product, fluoroscopy time and intraoperative complications were compared between the groups. Results: The accuracy of 3D-navigated percutaneous pedicle screw placement was 92.66 % while an accuracy of 88.08 % was achieved using standard fluoroscopy (p = 0.19). The fluoroscopy time was significantly less in the navigation group compared to the control group (p = 0.0002). There were no significant differences in radiation exposure, duration of surgery or intraoperative complications between the groups. Discussion and conclusion: The results suggest that 3D-navigation facilitates higher accuracy in percutaneous pedicle screw placement of traumatic fractures of the thoracolumbar junction, although limitations should be considered. In this study 3D-navigation did not increase fluoroscopy time, while radiation exposure and surgery time were comparable.

6.
Foot Ankle Int ; 45(5): 446-455, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38501715

RESUMO

BACKGROUND: For the temporary treatment of ankle fracture dislocations (AFDs), previous studies indicate higher rates of secondary loss of reduction (LOR) with splint immobilization, prompting consideration for expanding indications for external fixation (ExFix). However, these studies did not investigate the influence of fracture morphology to further improve patient selection. The aim of this study was to investigate the influence of Lauge-Hansen injury type on the LOR rate in bimalleolar or trimalleolar AFDs for temporary cast vs ExFix immobilization. METHODS: In this retrospective cohort study, patients with isolated AFD cases treated at our institution from 2011 to 2020 were reviewed. Inclusion criteria required radiographs depicting initial dislocation and appropriate reduction after Cast or ExFix immobilization. Exclusion criteria encompassed concomitant injuries, open fractures, conservative management as well as surgery performed within 48 hours or at a different facility. Patients were grouped by temporary treatment (Cast or ExFix). The primary endpoint was LOR prior to definitive surgery across various Lauge-Hansen types. RESULTS: The LOR rate was significantly higher in the cast group (40/152, 26.3%) compared to the ExFix group (5/191, 2.6%; P < .0001). In the cast group, LOR was associated with an increase in time to definitive surgery by a mean of 3 days (P < .002). During cast treatment, LOR was significantly more likely for pronation abduction (P = .001) and supination external rotation injuries (P < .0001), whereas no significant differences were observed for pronation external rotation (P = .006), supination adduction (P > .99), and fractures not classifiable (P > .99). CONCLUSION: In cases of AFDs resulting from supination external rotation or pronation abduction trauma according to the Lauge-Hansen classification, especially in the setting of an additional posterior malleolar fracture, primary application of external fixation should be considered to reduce the risk for secondary loss of reduction. LEVEL OF EVIDENCE: Level III, retrospective cohort study.


Assuntos
Fraturas do Tornozelo , Moldes Cirúrgicos , Fratura-Luxação , Humanos , Fraturas do Tornozelo/cirurgia , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Fratura-Luxação/cirurgia , Fixação de Fratura/métodos , Idoso , Estudos de Coortes
7.
Int J Med Robot ; 20(1): e2607, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38536717

RESUMO

BACKGROUND: The aim of the study was to validate a software-based planning method for the Schoettle Point and to evaluate precision and time efficiency of its live overlay on the intraoperative X-ray. METHODS: A software-based method was compared with surgeons' manual planning in an inter- and intrarater study. Subsequently, K-wire placement was performed with and without an overlay of the planning. The time used and the precision achieved were statistically compared. RESULTS: The average deviation between the surgeons (1.68 mm; 2.26 mm) was greater than the discrepancy between the surgeons and the software-based planning (1.30 mm; 1.38 mm). In the intrarater comparison, software-based planning provided consistent results. Live overlay showed a significantly lower positioning error (0.9 ± 0.5 mm) compared with that without overlay (3.0 ± 1.4 mm, p = 0.000; 3.1 ± 1.4 mm, p = 0.001). Live overlay did not achieve a significant time gain (p = 0.393; p = 0.678). CONCLUSION: The software-based planning and live overlay of the Schoettle Point improves surgical precision without negatively affecting time efficiency.


Assuntos
Instabilidade Articular , Luxação Patelar , Procedimentos de Cirurgia Plástica , Humanos , Luxação Patelar/diagnóstico por imagem , Luxação Patelar/cirurgia , Articulação do Joelho/cirurgia , Ligamentos Articulares , Radiografia , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia
8.
Eur J Trauma Emerg Surg ; 50(3): 1153-1164, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38363327

RESUMO

PURPOSE: To determine the incidence of severe surgical adverse events (sSAE) after surgery of patients with subaxial cervical spine injury (sCS-Fx) and to identify patient, treatment, and injury-related risk factors. METHODS: Retrospective analysis of clinical and radiological data of sCS-Fx patients treated surgically between 2010 and 2020 at a single national trauma center. Baseline characteristics of demographic data, preexisting conditions, treatment, and injury morphology were extracted. Incidences of sSAEs within 60 days after surgery were analyzed. Univariate analysis and binary logistic regression for the occurrence of one or more sSAEs were performed to identify risk factors. P-values < .05 were considered statistically significant. RESULTS: Two hundred and ninety-two patients were included. At least one sSAE occurred in 49 patients (16.8%). Most frequent were sSAEs of the surgical site (wound healing disorder, infection, etc.) affecting 29 patients (9.9%). Independent potential risk factors in logistic regression were higher age (OR 1.02 [1.003-1.04], p = .022), the presence of one or more modifiers in the AO Spine Subaxial Injury Classification (OR 2.02 [1.03-3.96], p = .041), and potentially unstable or unstable facet injury (OR 2.49 [1.24-4.99], p = .010). Other suspected risk factors were not statistically significant, among these Injury Severity Score, the need for surgery for concomitant injuries, the primary injury type according to AO Spine, and preexisting medical conditions. CONCLUSION: sSAE rates after treatment of sCS-Fx are high. The identified risk factors are not perioperatively modifiable, but their knowledge should guide intra and postoperative care and surgical technique.


Assuntos
Vértebras Cervicais , Complicações Pós-Operatórias , Traumatismos da Coluna Vertebral , Humanos , Masculino , Feminino , Fatores de Risco , Estudos Retrospectivos , Vértebras Cervicais/lesões , Vértebras Cervicais/cirurgia , Pessoa de Meia-Idade , Incidência , Adulto , Complicações Pós-Operatórias/epidemiologia , Traumatismos da Coluna Vertebral/cirurgia , Traumatismos da Coluna Vertebral/epidemiologia , Idoso
9.
J Clin Med ; 13(3)2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38337392

RESUMO

INTRODUCTION: This study analyzed the incidence of secondary dislocations (sDLs) after surgical stabilization of AO Spine type B and C injuries of the subaxial cervical spine (sCS). MATERIALS AND METHODS: Patients treated for injuries of the sCS from 2010 to 2020 were retrospectively analyzed for the incidence of sDL within 60 days after first surgery. A univariate analysis of variables potentially influencing the risk of sDL was performed. Patients with solitary anterior stabilization underwent subgroup analysis. The treatment of sDLs was described. RESULTS: A total of 275 patients were included. sDLs occurred in 4.0% of patients (n = 11) in the total sample, most frequently after solitary anterior stabilization with 8.0% (n = 10, p = 0.010). Only one sDL occurred after combined stabilization and no sDLs after posterior stabilization. In the total sample and the anterior subgroup, variables significantly associated with sDL were older age (p = 0.001) and concomitant unstable facet joint injury (p = 0.020). No neurological deterioration occurred due to sDL and most patients were treated with added posterior stabilization. sDL is frequent after solitary anterior stabilization and rare after posterior or combined stabilization. DISCUSSION: Patients of higher age and with unstable facet joint injuries should be followed up diligently to detect sDLs in time. Neurological deterioration does not regularly occur due to sDL, and most patients can be treated with added posterior stabilization.

10.
JMIR Form Res ; 8: e47572, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38271087

RESUMO

BACKGROUND: Medical photography plays a pivotal role in modern health care, serving multiple purposes ranging from patient care to medical documentation and education. Specifically, it aids in wound management, surgical planning, and medical training. While digital cameras have traditionally been used, smartphones equipped with specialized apps present an intriguing alternative. Smartphones offer several advantages, including increased usability and efficiency and the capability to uphold medicolegal standards more effectively and consistently. OBJECTIVE: This study aims to assess whether implementing a specialized smartphone app could lead to more frequent and efficient use of medical photography. METHODS: We carried out this study as a comprehensive single-center panel investigation at a level 1 trauma center, encompassing various settings including the emergency department, operating theaters, and surgical wards, over a 6-month period from June to November 2020. Using weekly questionnaires, health care providers were asked about their experiences and preferences with using both digital cameras and smartphones equipped with a specialized medical photography app. Parameters such as the frequency of use, time taken for image upload, and general usability were assessed. RESULTS: A total of 65 questionnaires were assessed for digital camera use and 68 for smartphone use. Usage increased significantly by 5.4 (SD 1.9) times per week (95% CI 1.7-9.2; P=.005) when the smartphone was used. The time it took to upload pictures to the clinical picture and archiving system was significantly shorter for the app (mean 1.8, SD 1.2 min) than for the camera (mean 14.9, SD 24.0 h; P<.001). Smartphone usage also outperformed the digital camera in terms of technical failure (4.4% vs 9.7%; P=.04) and for the technical process of archiving (P<.001) pictures to the picture archiving and communication system (PACS) and display images (P<.001) from it. No difference was found in regard to the photographer's intent (P=.31) or reasoning (P=.94) behind the pictures. Additionally, the study highlighted that potential concerns regarding data security and patient confidentiality were also better addressed through the smartphone app, given its encryption capabilities and password protection. CONCLUSIONS: Specialized smartphone apps provide a secure, rapid, and user-friendly platform for medical photography, showing significant advantages over traditional digital cameras. This study supports the notion that these apps not only have the potential to improve patient care, particularly in the realm of wound management, but also offer substantial medicolegal and economic benefits. Future research should focus on additional aspects such as patient comfort and preference, image resolution, and the quality of photographs, as well as seek to corroborate these findings through a larger sample size.

11.
J Orthop Surg Res ; 18(1): 924, 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38044441

RESUMO

BACKGROUND: Intraoperative 3D imaging using cone-beam CT (CBCT) provides improved assessment of implant position and reduction in spine surgery, is used for navigated surgical techniques, and therefore leads to improved quality of care. However, in some cases the image quality is not sufficient to correctly assess pedicle screw position and reduction, especially due to metal artifacts. The aim of this study was to investigate whether changing the acquisition trajectory of the CBCT in relation to the pedicle screw position during dorsal instrumentation of the spine can reduce metal artifacts and consequently improve image quality as well as clinical assessability on the artificial bone model. METHODS: An artificial bone model was instrumented with pedicle screws in the thoracic and lumbar spine region (Th10 to L5). Then, the acquisition trajectory of the CBCT (Cios Spin, Siemens, Germany) to the pedicle screws was systematically changed in 5° steps in angulation (- 30° to + 30°) and swivel (- 30° to + 30°). Subsequently, radiological evaluation was performed by three blinded, qualified raters on image quality using 9 questions (including anatomical structures, implant position, appearance of artifacts) with a score (1-5 points). For statistical evaluation, the image quality of the different acquisition trajectories was compared to the standard acquisition trajectory and checked for significant differences. RESULTS: The angulated acquisition trajectory increased the score for subjective image quality (p < 0.001) as well as the clinical assessability of pedicle screw position (p < 0.001) highly significant with particularly strong effects on subjective image quality in the vertebral pedicle region (d = 1.06). Swivel of the acquisition trajectory significantly improved all queried domains of subjective image quality (p < 0.001) as well as clinical assessability of pedicle screw position (p < 0.001). The data show that maximizing the angulation or swivel angle toward 30° provides the best tested subjective image quality. Angulation and swivel of the acquisition trajectory result in a clinically relevant improvement in image quality in intraoperative 3D imaging (CBCT) during dorsal instrumentation of the spine.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Tomografia Computadorizada de Feixe Cônico Espiral , Cirurgia Assistida por Computador , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Tomografia Computadorizada de Feixe Cônico , Imageamento Tridimensional/métodos , Cirurgia Assistida por Computador/métodos
12.
Brain Spine ; 3: 101780, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38020982

RESUMO

Introduction: There is ample evidence that higher accuracy can be achieved in thoracolumbar pedicle screw placement by using spinal navigation. Still, to date, the evidence regarding the influence of the use of navigation on the screw diameter to pedicle width ratio remains limited. Research question: The aim of this study was to investigate the implications of navigation in thoracolumbar pedicle screw placement not only on screw accuracy, but on the screw diameter to pedicle width ratio as well. Material and methods: In this single-center single-surgeon study, 45 Patients undergoing navigated thoracolumbar pedicle screw placement were prospectively included. The results were compared with a matched comparison group of patients in which screw placement was performed under fluoroscopic guidance. The screw accuracy and the screw diameter to pedicle width ratio of every screw were compared between the groups. Results: Screw accuracy was significantly higher in the navigation group compared to the fluoroscopic guidance group, alongside with a significant increase of the screw diameter to pedicle width ratio by approximately 10%. In addition, both the intraoperative radiation dose and the operating time tended to be lower in the study group. Conclusion: This study was able to show that navigated thoracolumbar pedicle screw placement not only increases the accuracy of screw placement but also facilitates the selection of the adequate screw sizes, which according to the literature has positive effects on fixation strength. Meanwhile, the use of navigation did not negatively affect the time needed for surgery or the patient's intraoperative exposure to radiation.

13.
BMC Musculoskelet Disord ; 24(1): 752, 2023 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-37742007

RESUMO

BACKGROUND: Studies have shown that pedicle screw placement using navigation can potentially reduce radiation exposure of surgical personnel compared to conventional methods. Spinal navigation is based on an interaction of a navigation software and 3D imaging. The 3D image data can be acquired using different imaging modalities such as iCT and CBCT. These imaging modalities vary regarding acquisition technique and field of view. The current literature varies greatly in study design, in form of dose registration, as well as navigation systems and imaging modalities analyzed. Therefore, the aim of this study was a standardized comparison of three navigation and imaging system combinations in an experimental setting in an artificial spine model. METHODS: In this experimental study dorsal instrumentation of the thoracolumbar spine was performed using three imaging/navigation system combinations. The system combinations applied were the iCT/Curve, cCBCT/Pulse and oCBCT/StealthStation. Referencing scans were obtained with each imaging modality and served as basis for the respective navigation system. In each group 10 artificial spine models received bilateral dorsal instrumentation from T11-S1. 2 referencing and control scans were acquired with the CBCTs, since their field of view could only depict up to five vertebrae in one scan. The field of view of the iCT enabled the depiction of T11-S1 in one scan. After instrumentation the region of interest was scanned again for evaluation of the screw position, therefore only one referencing and one control scan were obtained. Two dose meters were installed in a spine bed ventral of L1 and S1. The dose measurements in each location and in total were analyzed for each system combination. Time demand regarding screw placement was also assessed for all system combinations. RESULTS: The mean radiation dose in the iCT group measured 1,6 ± 1,1 mGy. In the cCBCT group the mean was 3,6 ± 0,3 mGy and in the oCBCT group 10,3 ± 5,7 mGy were measured. The analysis of variance (ANOVA) showed a significant (p < 0.0001) difference between the three groups. The multiple comparisions by the Kruskall-Wallis test showed no significant difference for the comparison of iCT and cCBCT (p1 = 0,13). Significant differences were found for the direct comparison of iCT and oCBCT (p2 < 0,0001), as well as cCBCT and oCBCT (p3 = 0,02). Statistical analysis showed that significantly (iCT vs. oCBCT p = 0,0434; cCBCT vs. oCBCT p = 0,0083) less time was needed for oCBCT based navigated pedicle screw placement compared to the other system combinations (iCT vs. cCBCT p = 0,871). CONCLUSION: Under standardized conditions oCBCT navigation demanded twice as much radiation as the cCBCT for the same number of scans, while the radiation exposure measured for the iCT and cCBCT for one scan was comparable. Yet, time effort was significantly less for oCBCT based navigation. However, for transferability into clinical practice additional studies should follow evaluating parameters regarding feasibility and clinical outcome under standardized conditions.


Assuntos
Parafusos Pediculares , Exposição à Radiação , Humanos , Diagnóstico por Imagem , Exposição à Radiação/prevenção & controle , Análise de Variância , Frequência Cardíaca
14.
Clin Biomech (Bristol, Avon) ; 108: 106054, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37541033

RESUMO

BACKGROUND: In ankle fractures with syndesmotic injury, the anatomic reduction of the ankle mortise is crucial for preventing osteoarthritis. Yet, no studies have analysed the effect of surgical reduction after unstable ankle fractures on patients' active functional outcome. METHODS: The Intraoperative 3D imaging data of patients surgically treated between 2012 and 2019 for ankle fracture with concomitant syndesmotic injury were reviewed. 58 patients were allocated to two groups depending on whether the criteria for radiologically optimal reduction were met (39 patients) or not (19 patients). Criteria for optimal reduction were composed of objectively measured and subjectively rated data. After undertaking the Olerud/Molander ankle score, a gait analysis and several active function tests using 3D motion capture were performed in order to evaluate kinetic and kinematic differences between both groups. FINDINGS: Patients showed deficits of range of motion and balance parameters on the injured ankle, however, there were no significant differences between both groups. INTERPRETATION: Although, the data did not show that radiological reduction criteria have a statistically significant effect on active functional outcome after a mean follow up time of 5.7 years, tendencies for a better outcome of patients that met the criteria could be seen. It also must be taken into consideration that results are limited by case number and allocation ratio, which made a sub-analysis of the separate reduction criteria unfeasible.


Assuntos
Fraturas do Tornozelo , Traumatismos do Tornozelo , Humanos , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/cirurgia , Tornozelo , Fenômenos Biomecânicos , Fixação Interna de Fraturas/métodos , Resultado do Tratamento , Traumatismos do Tornozelo/diagnóstico por imagem , Estudos Retrospectivos
15.
J Med Imaging (Bellingham) ; 10(3): 034503, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37216154

RESUMO

Purpose: Mobile C-arm systems represent the standard imaging devices within the field of spine surgery. In addition to 2D imaging, they allow for 3D scans while preserving unrestricted patient access. For viewing, the acquired volumes are adjusted such that their anatomical standard planes align with the axes of the viewing modality. This difficult and time-consuming step is currently performed manually by the leading surgeon. This process is automatized within this work to improve the usability of C-arm systems. Thereby, the spinal region consisting of multiple vertebrae and the standard planes of all vertebrae being of interest to the surgeon need to be taken into account. Approach: An object detection algorithm based on the you only look once version 3 architecture, adapted to 3D inputs, is compared with a segmentation-based approach employing a 3D U-Net. Both algorithms are trained on a dataset of 440 and tested on 218 spinal volumes. Results: Although the detection-based algorithm is slightly inferior concerning the detection (91% versus 97% accuracy), localization (1.26 mm versus 0.74 mm error) and alignment accuracy (5.00 deg versus 4.73 deg error), it outperforms the segmentation-based one in terms of speed (5 s versus 38 s). Conclusions: Both algorithms show similar good results. However, the speed gain of the detection-based algorithm, resulting in a run time of 5 s, makes it more suitable for usage in an intra-operative scenario.

16.
J Clin Med ; 12(3)2023 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-36769397

RESUMO

Studies have reported a high percentage of ankle fracture dislocations with secondary loss of reduction during primary treatment with a splint or cast. This study aimed to assess the rate of secondary loss of reduction in unimalleolar ankle fracture dislocations treated primarily with a cast or external fixator, identify the potential influence of fracture morphology, and investigate the potential implications. Unimalleolar ankle fracture dislocations with and without posterior malleolar fracture between 2011 and 2020 were included. Patients were categorized into two groups, depending on the method of temporary treatment. Fracture morphology, time to definitive surgery, and soft-tissue complications were compared. Of 102 patients, loss of reduction tended to occur more often in the cast group (17.3%) than in the external fixator group (6.0%). The presence of a posterior malleolar fracture did not have a significant influence on loss of reduction in cast immobilization; however, the fragment proved to be significantly bigger in cases with loss of reduction. No statistically significant differences in soft tissue complications or time to definitive surgery were found. Surgeons should consider the application of interval external fixation in the primary treatment of unimalleolar ankle fracture dislocations with additional posterior malleolar fractures.

17.
Chirurgie (Heidelb) ; 94(4): 292-298, 2023 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-36600030

RESUMO

Computer-assisted procedures are becoming increasingly more relevant in orthopedics and trauma surgery. The data situation on these systems has improved in recent years but still has a low level of evidence. In particular, data on short-term or medium-term results on the use of these procedures are currently available. These could show that improved precision and reproducibility of the surgical procedures can be achieved by the use of computer-assisted procedures. Nevertheless, there is still no recommendation in the current guidelines for routine use.


Assuntos
Procedimentos Ortopédicos , Robótica , Cirurgia Assistida por Computador , Robótica/métodos , Cirurgia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Computadores
18.
Sci Rep ; 13(1): 661, 2023 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-36635339

RESUMO

Soft-tissue conditioning due to posttraumatic oedema after complicated joint fractures is a central therapeutic aspect both pre- and postoperatively. On average, 6-10 days pass until the patient is suitable for surgery. This study compares the decongestant effect of vascular impulse technology (VIT) with that of conventional elevation. In this monocentric RCT, 68 patients with joint fractures of the upper (n = 36) and lower (n = 32) extremity were included and randomized after consent in a 1:1 ratio. Variables were evaluated for all fractures together and additionally subdivided into upper or lower extremity for better clinical comparability. Primary endpoint was the time in days from hospital admission to operability. Secondary endpoints were total length of stay, oedema reduction, pain intensity, complications, and revisions. The time from admission until operability was reduced by 1.4 (95% CI - 0.4; 3.1) days in the mITT analysis (p = 0.120) and was statistically significant with 1.7 (95% CI 0.1; 3.3) days in the as-treated sensitivity analysis (pAT = 0.038). Significantly less pain and a faster oedema reduction were found in the intervention group. Due to rare occurrences, nothing can be concluded regarding complications and revisions. Administration of VIT therapy did not lead to a significant reduction in time until operability in the whole population but was superior to elevation for soft-tissue conditioning and pain reduction. However, there was a significant reduction by 2.5 days (95% CI 0.7; 4.3) in the subgroup of lower extremity fractures. VIT therapy therefore seems to be a helpful tool in the treatment of posttraumatic oedema after complex joint fractures of the lower and upper extremity, especially in tibial head and lower leg fractures.


Assuntos
Fraturas Ósseas , Humanos , Edema/etiologia , Fraturas Ósseas/complicações , Fraturas Ósseas/cirurgia , Articulações , Extremidade Inferior , Fatores de Tempo , Resultado do Tratamento
19.
Knee Surg Sports Traumatol Arthrosc ; 31(7): 2870-2876, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36454291

RESUMO

PURPOSE: Patellar maltracking caused by a rupture of the medial patellofemoral ligament (MPFL) can be improved by MPFL reconstruction (MPFL-R) with a tendon graft. Nonresorbable suture tape (FiberTape®, FT) is possibly becoming an option to tendon grafts for MPFL-R. Patella-side fixation of FT can be performed with suture anchors or via soft-tissue fixation. The aim of this study was to investigate patellar tracking considering soft-tissue-based and anchor-based patella-side fixation techniques. METHODS: In eight fresh-frozen human knee joint specimens (m/f 4/4; age 75 ± 10 years), the MPFL was identified, and a rupture was placed near the femoral insertion site. In the study group (SG; 4 knees), soft-tissue fixation of the FT was performed at the medial patellar retinaculum; in the control group (CG; 4 knees), FT was fixed at the patella via suture anchors. For native MPFL (nMPFL), ruptured ("injured") MPFL (iMPFL) and reconstructed MPFL (FT-MPFL-SG, respectively, FT-MPFL-CG) cone beam CT scans were performed in 15°, 30°, and 45° of knee joint flexion. Patellar tracking was assessed using the radiological parameters patellar tilt (PT), congruence angle (CA) and posterior patellar edge-trochlear groove ratio (PTR). RESULTS: All recorded radiological parameters increased, respectively, decreased in the CG and SG from the nMPFL to the iMPFL state. After MPFL-R, all parameters normalized when compared to the intact state (nMPFL), regardless of patella-side fixation technique. All investigated parameters of patellotrochlear alignment were positively, respectively, negatively significantly (p < 0.05) correlated throughout all evaluated conditions (nMPFL, iMPFL, FT-MPFL-SG, FT-MPFL-CG). CONCLUSION: MPFL-R with a nonresorbable suture tape can normalize patellar maltracking in fresh-frozen human knee joint specimens in earlier degrees of knee joint flexion independent of patella-side fixation technique. The investigated parameters of patellotrochlear alignment correlate with each other.


Assuntos
Luxação Patelar , Articulação Patelofemoral , Humanos , Idoso , Idoso de 80 Anos ou mais , Patela/cirurgia , Articulação Patelofemoral/cirurgia , Cadáver , Articulação do Joelho/cirurgia , Ligamentos Articulares/cirurgia , Suturas , Luxação Patelar/cirurgia
20.
Eur J Trauma Emerg Surg ; 49(1): 373-381, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36048181

RESUMO

PURPOSE: Intraoperative 3D imaging has become a valued tool in assessing the quality of reduction and implant placement in orthopedic trauma surgery. In our institution, 3D imaging is used routinely since 2001. To evaluate the intraoperative findings and consequences of this technique, intraoperative revision rates in cases with 3D imaging were analyzed. METHODS: All operative procedures carried out with intraoperative 3D imaging between August 2001 and December 2016 were included. The scans were assessed intraoperatively and documented thereafter. In case of malreduction or misplaced implants, an immediate revision was performed. The number of scans per case as well as the findings and consequences drawn regarding the anatomical region were analyzed. RESULTS: 4721 cases with 7201 3D scans were included in this study. The most common anatomical regions were the ankle (22.3%), the calcaneus (14.8%) and the tibial head (9.5%). In 19.1% of all cases, an intraoperative revision was performed. The highest revision rates were found with 36.0% in calcaneal fractures, 24.8% in fractures of the tibial plateau, 22.3% in injuries of the ankle. In 52.0% of revisions, the reduction was improved regarding intra-articular steps or joint congruency. In 30.5% an implant was corrected. CONCLUSION: Intraoperative revision due to results of 3D imaging was performed in almost one-fifth of cases. This illustrates the improved possibilities to detect malreduction and implant misplacements intraoperatively and thus the abilities to improve surgical outcome. LEVEL OF EVIDENCE: III.


Assuntos
Fraturas Ósseas , Imageamento Tridimensional , Humanos , Imageamento Tridimensional/métodos , Fixação Interna de Fraturas/métodos , Estudos Retrospectivos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Reoperação