J Acoust Soc Am ; 154(5): 2858-2868, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37930178

RESUMO

Ultrasonic backscatter techniques are being developed to detect changes in bone caused by osteoporosis and other diseases. Backscatter measurements performed at peripheral skeletal sites such as the heel may place the interrogated region of bone tissue in the acoustic near field of the transducer. The purpose of this study is to investigate how measurements in the near field affect backscatter parameters used for ultrasonic bone assessment. Ultrasonic measurements were performed in a water tank using a planar 2.25 MHz transducer. Signals were acquired for five transducer-specimen distances: N/4, N/2, 3 N/4, N, and 5 N/4, where N is the near-field distance, a location that represents the transition from the near field to far field. Five backscatter parameters previously identified as potentially useful for ultrasonic bone assessment purposes were measured: apparent integrated backscatter, frequency slope of apparent backscatter (FSAB), frequency intercept of apparent backscatter, normalized mean of the backscatter difference, and backscatter amplitude decay constant. All five parameters depended on transducer-specimen distance to varying degrees with FSAB exhibiting the greatest dependence on distance. These results suggest that laboratory studies of bone should evaluate the performance of backscatter parameters using transducer-specimen distances that may be encountered clinically including distances where the ultrasonically interrogated region is in the near field of the transducer.


Assuntos
Osso Esponjoso , Ultrassom , Ultrassom/métodos , Osso Esponjoso/diagnóstico por imagem , Densidade Óssea , Ultrassonografia/métodos , Espalhamento de Radiação , Transdutores
2.
Ultrasound Med Biol ; 49(12): 2489-2496, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37716831

RESUMO

OBJECTIVE: The ultrasonic properties of scalp may be relevant to a variety of applications including transcranial ultrasound. However, there is no information about the ultrasonic properties of scalp available in the literature. While ultrasonic studies of skin from other anatomic regions have been previously reported, scalp tissue is generally thicker with a higher density of hair follicles, blood vessels and sebaceous glands. Thus, it is unknown if the ultrasonic properties of scalp are similar to skin from other regions. The goal of this study was to measure the ultrasonic properties of human scalp. METHODS: Pulse-echo measurements were performed with a 7.5 MHz ultrasound transducer to determine the speed of sound (SOS), frequency slope of attenuation (FSA) and integrated backscatter coefficient (IBC) of 32 specimens of formalin-fixed human scalp from four donors. RESULTS: The means ± standard deviations for these three ultrasonic quantities measured in the frequency range 2.83-7.74 MHz over all specimens were SOS = 1525 ± 16.92 m/s, FSA = 2.59 ± 0.724 dB/cm/MHz and IBC = 0.122 ± 0.0746 cm-1 Sr-1. CONCLUSION: These values are comparable to reported values for human skin from other parts of the body, but some differences in SOS and IBC exist.


Assuntos
Couro Cabeludo , Ultrassom , Humanos , Ultrassonografia , Som , Imagens de Fantasmas
3.
Ultrasound Med Biol ; 48(6): 997-1009, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35282987

RESUMO

Ultrasonic techniques are being developed to detect changes in cancellous bone caused by osteoporosis. The goal of this study was to test the relative in vivo performance of eight backscatter parameters developed over the last several years for ultrasonic bone assessment: apparent integrated backscatter (AIB), frequency slope of apparent backscatter (FSAB), frequency intercept of apparent backscatter (FIAB), normalized mean of the backscatter difference (nMBD), normalized slope of the backscatter difference (nSBD), normalized intercept of the backscatter difference (nIBD), normalized backscatter amplitude ratio (nBAR) and backscatter amplitude decay constant (BADC). Backscatter measurements were performed on the left and right femoral necks of 80 adult volunteers (age = 25 ± 11 y) using an imaging system equipped with a convex array transducer. For comparison, additional ultrasonic measurements were performed at the left and right heel using a commercially available heel-bone ultrasonometer that measured the stiffness index. Six of the eight backscatter parameters (all but nSBD and nIBD) exhibited similar and highly significant (p < 0.000001) left-right correlations (0.51 ≤ R ≤ 0.68), indicating sensitivity to naturally occurring variations in bone tissue. Left-right correlations for the stiffness index measured at the heel (R = 0.75) were not significantly better than those produced by AIB, FSAB and FIAB. The short-term precisions of AIB, nMBD, nBAR and BADC (7.8%-11.7%) were comparable to that of the stiffness index measured with the heel-bone ultrasonometer (7.5%).


Assuntos
Colo do Fêmur , Ultrassom , Adolescente , Adulto , Densidade Óssea , Colo do Fêmur/diagnóstico por imagem , Humanos , Espalhamento de Radiação , Ultrassom/métodos , Ultrassonografia/métodos , Adulto Jovem
4.
Artigo em Inglês | MEDLINE | ID: mdl-34138705

RESUMO

Ultrasonic backscatter techniques may offer a useful approach for detecting changes in bone caused by osteoporosis. The goal of this study was to investigate how bone mineral density (BMD) and the microstructure of human cancellous bone affect three ultrasonic backscatter parameters that have been identified as potentially useful for ultrasonic bone assessment purposes: the apparent integrated backscatter (AIB), the frequency slope of apparent backscatter (FSAB), and the frequency intercept of apparent backscatter (FIAB). Ultrasonic measurements were performed with a 3.5-MHz broadband transducer on 54 specimens of human cancellous bone prepared from the proximal femur. Microstructural parameters and BMD were measured using X-ray microcomputed tomography (micro-CT). Relationships between AIB, FSAB, FIAB, and the micro-CT parameters were investigated using univariate and multivariate statistical analysis techniques. Moderate-to-strong univariate correlations were observed between the backscatter parameters and microstructure and BMD in many cases. The partial correlation analysis indicated that the backscatter parameters are dependent on microstructure independently of BMD in some cases. Multiple stepwise linear regression analysis used to generate multivariate models found that microstructure was a significant predictor of the backscatter parameters in most cases.


Assuntos
Osso Esponjoso , Ultrassom , Densidade Óssea , Osso Esponjoso/diagnóstico por imagem , Humanos , Espalhamento de Radiação , Ultrassonografia , Microtomografia por Raio-X
5.
J Acoust Soc Am ; 143(6): 3642, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29960442

RESUMO

Ultrasonic backscatter techniques are being developed to detect changes in cancellous bone caused by osteoporosis. One technique, called the backscatter difference technique, measures the power difference between two portions of a backscatter signal. The goal of the present study is to investigate how bone mineral density (BMD) and the microstructure of human cancellous bone influence four backscatter difference parameters: the normalized mean of the backscatter difference (nMBD) spectrum, the normalized slope of the backscatter difference spectrum, the normalized intercept of the backscatter difference spectrum, and the normalized backscatter amplitude ratio (nBAR). Ultrasonic measurements were performed with a 3.5 MHz broadband transducer on 54 specimens of human cancellous bone from the proximal femur. Volumetric BMD and the microstructural characteristics of the specimens were measured using x-ray micro-computed tomography. Of the four ultrasonic parameters studied, nMBD and nBAR demonstrated the strongest univariate correlations with density and microstructure. Multivariate analyses indicated that nMBD and nBAR depended on trabecular separation and possibly other microstructural characteristics of the specimens independently of BMD. These findings suggest that nMBD and nBAR may be sensitive to changes in the density and microstructure of bone caused by osteoporosis.


Assuntos
Densidade Óssea , Osso Esponjoso/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Osteoporose/diagnóstico por imagem , Ondas Ultrassônicas , Ultrassonografia/métodos , Adulto , Osso Esponjoso/patologia , Feminino , Fêmur/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Osteoporose/patologia , Valor Preditivo dos Testes , Espalhamento de Radiação , Fatores de Tempo , Microtomografia por Raio-X
6.
J Acoust Soc Am ; 143(2): 911, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29495707

RESUMO

Materials that simulate the ultrasonic properties of tissues are used widely for clinical and research purposes. However, relatively few materials are known to simulate the ultrasonic properties of cancellous bone. The goal of the present study was to investigate the suitability of using a polymer, open-cell rigid foam (OCRF) produced by Sawbones®. Measurements were performed on OCRF specimens with four different densities. Ultrasonic speed of sound and normalized broadband ultrasonic attenuation were measured with a 0.5 MHz transducer. Three backscatter parameters were measured with a 5 MHz transducer: apparent integrated backscatter, frequency slope of apparent backscatter, and normalized mean of the backscatter difference. X-ray micro-computed tomography was used to measure the microstructural characteristics of the OCRF specimens. The trabecular thickness and relative bone volume of the OCRF specimens were similar to those of human cancellous bone, but the trabecular separation was greater. In most cases, the ultrasonic properties of the OCRF specimens were similar to values reported in the literature for cancellous bone, including dependence on density. In addition, the OCRF specimens exhibited an ultrasonic anisotropy similar to that reported for cancellous bone.


Assuntos
Osso Esponjoso/diagnóstico por imagem , Imagens de Fantasmas , Polímeros/química , Ultrassom , Ultrassonografia/instrumentação , Dureza , Humanos , Movimento (Física) , Porosidade , Espalhamento de Radiação , Fatores de Tempo , Ondas Ultrassônicas , Microtomografia por Raio-X
7.
J Acoust Soc Am ; 142(2): 540, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28863582

RESUMO

A variety of ultrasonic techniques have been developed to detect changes in bone caused by osteoporosis. One approach, called the backscatter difference technique, analyzes the power difference between two different portions of a backscatter signal. Analysis gates with a certain delay τd, width τw, and separation τs are used to define portions of the backscatter signal for analysis. The goal of the present study was to investigate how different choices of τd, τw, and τs affect four backscatter difference parameters: the normalized mean of the backscatter difference (nMBD), the normalized slope of the backscatter difference (nSBD), the normalized intercept of the backscatter difference (nIBD), and the normalized backscatter amplitude ratio (nBAR). Backscatter measurements were performed on 54 cube shaped specimens of human cancellous bone. nMBD, nSBD, nIBD, and nBAR were determined for 34 different combinations of τd, τw, and τs for each specimen. nMBD and nBAR demonstrated the strongest correlations with apparent bone density (0.48 ≤ Rs ≤ 0.90). Generally, the correlations were found to improve as τw + τs was increased and as τd was decreased. Among the four backscatter difference parameters, the measured values of nMBD were least sensitive to gate choice (<16%).


Assuntos
Densidade Óssea , Osso Esponjoso/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Osteoporose/diagnóstico por imagem , Ondas Ultrassônicas , Ultrassonografia/métodos , Adulto , Anisotropia , Osso Esponjoso/fisiopatologia , Feminino , Fêmur/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Osteoporose/fisiopatologia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Espalhamento de Radiação
8.
J Acoust Soc Am ; 138(4): 2449-57, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26520327

RESUMO

Ultrasonic backscatter techniques are being developed to diagnose osteoporosis. Tissues that lie between the transducer and the ultrasonically interrogated region of bone may produce errors in backscatter measurements. The goal of this study is to investigate the effects of intervening tissues on ultrasonic backscatter measurements of bone. Measurements were performed on 24 cube shaped specimens of human cancellous bone using a 5 MHz transducer. Measurements were repeated after adding a 1 mm thick plate of cortical bone to simulate the bone cortex and a 3 cm thick phantom to simulate soft tissue at the hip. Signals were analyzed to determine three apparent backscatter parameters (apparent integrated backscatter, frequency slope of apparent backscatter, and frequency intercept of apparent backscatter) and three backscatter difference parameters [normalized mean backscatter difference (nMBD), normalized slope of the backscatter difference, and normalized intercept of the backscatter difference]. The apparent backscatter parameters were impacted significantly by the presence of intervening tissues. In contrast, the backscatter difference parameters were not affected by intervening tissues. However, only one backscatter difference parameter, nMBD, demonstrated a strong correlation with bone mineral density. Thus, among the six parameters tested, nMBD may be the best choice for in vivo backscatter measurements of bone when intervening tissues are present.


Assuntos
Fêmur/diagnóstico por imagem , Absorciometria de Fóton , Animais , Densidade Óssea , Quadril , Humanos , Técnicas In Vitro , Osteoporose/diagnóstico por imagem , Imagens de Fantasmas , Tíbia , Transdutores , Ultrassonografia
9.
J Biomed Mater Res A ; 88(2): 491-502, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18306307

RESUMO

To meet the challenge of regenerating bone lost to disease or trauma, biodegradable scaffolds are being investigated as a way to regenerate bone without the need for an auto- or allograft. Here, we have developed a novel microsphere-based chitosan/nanocrystalline calcium phosphate (CaP) composite scaffold and investigated its potential compared to plain chitosan scaffolds to be used as a bone graft substitute. Composite and chitosan scaffolds were prepared by fusing microspheres of 500-900 microm in diameter, and porosity, degradation, compressive strength, and cell growth were examined. Both scaffolds had porosities of 33-35% and pore sizes between 100 and 800 . However, composite scaffolds were much rougher and, as a result, had 20 times more surface area/unit mass than chitosan scaffolds. The compressive modulus of hydrated composite scaffolds was significantly higher than chitosan scaffolds (9.29 +/- 0.8 MPa vs. 3.26 +/- 2.5 MPa), and composite scaffolds were tougher and more flexible than what has been reported for other chitosan-CaP composites or CaP scaffolds alone. Using X-ray diffraction, scaffolds were shown to contain partially crystalline hydroxyapatite with a crystallinity of 16.7% +/- 6.8% and crystallite size of 128 +/- 55 nm. Fibronection adsorption was increased on composite scaffolds, and cell attachment was higher on composite scaffolds after 30 min, although attachment rates were similar after 1 h. Osteoblast proliferation (based on dsDNA measurements) was significantly increased after 1 week of culture. These studies have demonstrated that composite scaffolds have mechanical properties and porosity sufficient to support ingrowth of new bone tissue, and cell attachment and proliferation data indicate composite scaffolds are promising for bone regeneration.


Assuntos
Regeneração Óssea , Fosfatos de Cálcio/química , Quitosana/química , Alicerces Teciduais , Adsorção , Animais , Materiais Biocompatíveis/química , Materiais Biocompatíveis/metabolismo , Substitutos Ósseos/química , Substitutos Ósseos/metabolismo , Fosfatos de Cálcio/metabolismo , Células Cultivadas , Quitosana/metabolismo , Força Compressiva , Humanos , Teste de Materiais , Osteoblastos/citologia , Osteoblastos/fisiologia , Porosidade , Proteínas/metabolismo , Propriedades de Superfície