Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Arthritis Res Ther ; 25(1): 44, 2023 03 20.
Artigo em Inglês | MEDLINE | ID: mdl-36941690

RESUMO

BACKGROUND: The role of the lung for the initiation and progression of rheumatoid arthritis (RA) is still unclear. Up to 10% of RA patients develop interstitial lung disease which remains a clinical challenge. Understanding early disease mechanisms is of great importance. The objective of this study was to determine whether there is an association between peripheral neutrophil phenotypes and presence of pulmonary abnormalities (PA) on chest high-resolution computed tomography (HRCT) in untreated early RA (ueRA). METHODS: Clinical data and blood were collected, and HRCT performed at diagnosis on 30 consecutive anti-citrullinated protein antibody (ACPA) and/or rheumatoid factor (RF) positive ueRA patients. HRCTs were evaluated for the presence of RA-associated parenchymal, airway and/or pleural abnormalities. Expression of phenotype markers on neutrophils were determined by flow cytometry. Levels of calprotectin, ACPA and RF were measured using immunoassays. RESULTS: The frequency of having any PA was 60%. Airway abnormalities were present in 50%, parenchymal nodules in 43% and interstitial lung abnormalities (ILA) in 10%. Unsupervised multivariate data analysis showed clustering of any PA with neutrophil activation, parameters of inflammation and RF titres. In univariate analysis, the patients with PA displayed significantly increased CD11b and decreased CD62L expression on neutrophils (1.2-fold, p = 0.014; 0.8-fold, p = 0.012) indicating activation and significantly increased RF IgM titre and CRP (5.7-fold, p = 0.0025; 2.3-fold, p = 0.0035) as compared to no PA. Titres of RF, but not ACPA, correlated with expression of the neutrophil activation marker CD11b. A stratified analysis demonstrated that airway involvement was the PA subtype with the strongest association with neutrophil activation. CONCLUSION: We report a strong association between radiographic airway findings and activation of circulating neutrophils in early RA supporting a role of innate immunity and the lung at disease onset. Our results also indicate different contributions of RF and ACPA in the RA pathogenesis.


Assuntos
Artrite Reumatoide , Doenças Pulmonares Intersticiais , Humanos , Ativação de Neutrófilo , Fator Reumatoide , Pulmão/patologia , Doenças Pulmonares Intersticiais/etiologia , Doenças Pulmonares Intersticiais/complicações , Autoanticorpos
2.
J Appl Clin Med Phys ; 24(3): e13871, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36583696

RESUMO

AIMS: The aims of the present study were to, for both a full-dose protocol and an ultra-low dose (ULD) protocol, compare the image quality of chest CT examinations reconstructed using TrueFidelity (Standard kernel) with corresponding examinations reconstructed using ASIR-V (Lung kernel) and to evaluate if post-processing using an edge-enhancement filter affects the noise level, spatial resolution and subjective image quality of clinical images reconstructed using TrueFidelity. METHODS: A total of 25 patients were examined with both a full-dose protocol and an ULD protocol using a GE Revolution APEX CT system (GE Healthcare, Milwaukee, USA). Three different reconstructions were included in the study: ASIR-V 40%, DLIR-H, and DLIR-H with additional post-processing using an edge-enhancement filter (DLIR-H + E2). Five observers assessed image quality in two separate visual grading characteristics (VGC) studies. The results from the studies were statistically analyzed using VGC Analyzer. Quantitative evaluations were based on determination of two-dimensional power spectrum (PS), contrast-to-noise ratio (CNR), and spatial resolution in the reconstructed patient images. RESULTS: For both protocols, examinations reconstructed using TrueFidelity were statistically rated equal to or significantly higher than examinations reconstructed using ASIR-V 40%, but the ULD protocol benefitted more from TrueFidelity. In general, no differences in observer ratings were found between DLIR-H and DLIR-H + E2. For the three investigated image reconstruction methods, ASIR-V 40% showed highest noise and spatial resolution and DLIR-H the lowest, while the CNR was highest in DLIR-H and lowest in ASIR-V 40%. CONCLUSION: The use of TrueFidelity for image reconstruction resulted in higher ratings on subjective image quality than ASIR-V 40%. The benefit of using TrueFidelity was larger for the ULD protocol than for the full-dose protocol. Post-processing of the TrueFidelity images using an edge-enhancement filter resulted in higher image noise and spatial resolution but did not affect the subjective image quality.


Assuntos
Aprendizado Profundo , Humanos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos
3.
Radiat Prot Dosimetry ; 195(3-4): 443-453, 2021 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-33948650

RESUMO

PURPOSE: To evaluate two chest tomosynthesis (CTS) scoring systems for cystic fibrosis (CF), one system developed by Vult von Steyern et al. (VvS) and one system based on the Brody scoring system for high-resolution computed tomography (HRCT) (modified Brody (mB)). Brody scoring of HRCT was used as reference. METHODS: In conjunction with routine control HRCT at clinical follow-up, 10 consecutive adult CF patients underwent CTS for research purposes. Four radiologists scored the CTS examinations using the mB and VvS scoring systems. All scores were compared to the Brody HRCT scores. The agreement between the evaluated CTS scoring systems and the reference HRCT scoring system was determined using Spearman's rank correlation coefficient and the intraclass correlation coefficient (ICC). MAJOR FINDINGS: Spearman's rank correlation coefficient showed strong correlations between HRCT score and both the mB and the VvS CTS total scores (median rs = 0.81 and 0.85, respectively). The ICC showed strong correlation between the CTS scoring systems and the reference: 0.88 for mB and 0.85 for VvS scoring. The median time for scoring was 20 and 10 minutes for the mB and VvS scoring systems, respectively. CONCLUSIONS: Both evaluated CTS scoring systems correlate well with the reference standard Brody HRCT scoring. The VvS CTS scoring system has a shorter reading time, suggesting its advantage in clinical practice.


Assuntos
Fibrose Cística , Adulto , Fibrose Cística/diagnóstico por imagem , Humanos , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X
4.
Acta Radiol ; 62(3): 348-359, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32438877

RESUMO

BACKGROUND: Digital tomosynthesis (DTS) might be a low-dose/low-cost alternative to computed tomography (CT). PURPOSE: To investigate DTS relative to CT for surveillance of incidental, solid pulmonary nodules. MATERIAL AND METHODS: Recruited from a population study, 106 participants with indeterminate solid pulmonary nodules on CT underwent surveillance with concurrently performed CT and DTS. Nodule size on DTS was assessed by manual diameter measurements and semi-automatic nodule segmentations were independently performed on CT. Measurement agreement was analyzed according to Bland-Altman with 95% limits of agreement (LoA). Detection of nodule volume change > 25% by DTS in comparison to CT was evaluated with receiver operating characteristics (ROC). RESULTS: A total of 81 nodules (76%) were assessed as measurable on DTS by two independent observers. Inter- and intra-observer LoA regarding change in average diameter were ± 2 mm. Calculation of relative volume change on DTS resulted in wide inter- and intra-observer LoA in the order of ± 100% and ± 50%. Comparing relative volume change between DTS and CT resulted in LoA of -58% to 67%. The area under the ROC curve regarding the ability of DTS to detect volumetric changes > 25% on CT was 0.58 (95% confidence interval [CI] = 0.40-0.76) and 0.50 (95% CI = 0.35-0.66) for the two observers. CONCLUSION: The results of the present study show that measurement variability limits the agreement between DTS and CT regarding nodule size change for small solid nodules.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Nódulo Pulmonar Solitário/diagnóstico por imagem , Estudos de Coortes , Feminino , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Projetos Piloto , Sensibilidade e Especificidade , Nódulo Pulmonar Solitário/patologia , Suécia , Tomografia Computadorizada por Raios X
5.
Clin Physiol Funct Imaging ; 41(2): 181-191, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33284499

RESUMO

Chronic airflow limitation (CAL) can be defined as fixed ratio of forced expiratory volume in 1 s (FEV1 )/forced vital capacity (FVC) < 0.70 after bronchodilation. It is unclear which is the most optimal ratio in relation to respiratory morbidity. The aim was to investigate to what extent different ratios of FEV1 /FVC were associated with any respiratory symptom. In a cross-sectional general population study, 15,128 adults (50-64 years of age), 7,120 never-smokers and 8,008 ever-smokers completed a respiratory questionnaire and performed FEV1 and FVC after bronchodilation. We calculated different ratios of FEV1 /FVC from 0.40 to 1.0 using 0.70 as reference category. We analysed odds ratios (OR) between different ratios and any respiratory symptom using adjusted multivariable logistic regression. Among all subjects, regardless of smoking habits, the lowest odds for any respiratory symptom was at FEV1 /FVC = 0.82, OR 0.48 (95% CI 0.41-0.56). Among never-smokers, the lowest odds for any respiratory symptom was at FEV1 /FVC = 0.81, OR 0.53 (95% CI 0.41-0.70). Among ever-smokers, the odds for any respiratory symptom was lowest at FEV1 /FVC = 0.81, OR 0.43 (95% CI 0.16-1.19), although the rate of inclining in odds was small in the upper part, that is FEV1 /FVC = 0.85 showed similar odds, OR 0.45 (95% CI 0.38-0.55). We concluded that the odds for any respiratory symptoms continuously decreased with higher FEV1 /FVC ratios and reached a minimum around 0.80-0.85, with similar results among never-smokers. These results indicate that the optimal threshold associated with respiratory symptoms may be higher than 0.70 and this should be further investigated in prospective longitudinal studies.


Assuntos
Estudos Transversais , Adulto , Criança , Volume Expiratório Forçado , Humanos , Estudos Prospectivos , Suécia/epidemiologia , Capacidade Vital
6.
Acad Radiol ; 28(10): e289-e296, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-32709583

RESUMO

RATIONALE AND OBJECTIVES: To evaluate the effect of reduction in effective dose on the reproduction of anatomical structures in chest tomosynthesis (CTS). MATERIALS AND METHODS: Twenty-four CTS examinations acquired at exposure settings resulting in an effective dose of 0.12 mSv for an average sized patient were included in the study. The examinations underwent simulated dose reduction to dose levels corresponding to 32%, 50%, and 70% of the original dose using a previously described and validated method. The image quality was evaluated by five thoracic radiologists who rated the fulfillment of specified image quality criteria in a visual grading study. The ratings for each image quality criterion in the dose-reduced images were compared to the corresponding ratings for the full-dose examinations using visual grading characteristics (VGC) analysis. The area under the resulting VGC curve (AUCVGC) provides a measure of the difference between the ratings, where an AUCVGC of 0.5 indicates no difference. RESULTS: The dose reductions resulted in inferior reproduction of structures compared to the original dose level (AUCVGC <0.5). Structures in the central region of the lung obtained the lowest AUCVGC for each dose level whereas the reproduction of structures in the parenchyma was least affected by the dose reduction. CONCLUSION: Although previous studies have shown that dose reduction in CTS is possible without affecting the performance of certain clinical tasks, the reproduction of normal anatomical structures is significantly degraded even at small reductions. It is therefore important to consider the clinical purpose of the CTS examinations before deciding on a permanent dose reduction.


Assuntos
Radiografia Torácica , Humanos , Doses de Radiação , Proteção Radiológica , Radiografia Torácica/normas
7.
J Digit Imaging ; 33(5): 1185-1193, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32779016

RESUMO

Emphysema is visible on computed tomography (CT) as low-density lesions representing the destruction of the pulmonary alveoli. To train a machine learning model on the emphysema extent in CT images, labeled image data is needed. The provision of these labels requires trained readers, who are a limited resource. The purpose of the study was to test the reading time, inter-observer reliability and validity of the multi-reader-multi-split method for acquiring CT image labels from radiologists. The approximately 500 slices of each stack of lung CT images were split into 1-cm chunks, with 17 thin axial slices per chunk. The chunks were randomly distributed to 26 readers, radiologists and radiology residents. Each chunk was given a quick score concerning emphysema type and severity in the left and right lung separately. A cohort of 102 subjects, with varying degrees of visible emphysema in the lung CT images, was selected from the SCAPIS pilot, performed in 2012 in Gothenburg, Sweden. In total, the readers created 9050 labels for 2881 chunks. Image labels were compared with regional annotations already provided at the SCAPIS pilot inclusion. The median reading time per chunk was 15 s. The inter-observer Krippendorff's alpha was 0.40 and 0.53 for emphysema type and score, respectively, and higher in the apical part than in the basal part of the lungs. The multi-split emphysema scores were generally consistent with regional annotations. In conclusion, the multi-reader-multi-split method provided reasonably valid image labels, with an estimation of the inter-observer reliability.


Assuntos
Enfisema Pulmonar , Feminino , Humanos , Pulmão , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Enfisema Pulmonar/diagnóstico por imagem , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
8.
BMJ Open Respir Res ; 7(1)2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32759170

RESUMO

BACKGROUND: The diagnosis of chronic obstructive pulmonary disease is based on the presence of persistent respiratory symptoms and chronic airflow limitation (CAL). CAL is based on the ratio of forced expiratory volume in 1 s to forced vital capacity (FEV1:FVC) after bronchodilation, and FEV1:FVC less than the fifth percentile is often used as a cut-off for CAL. The aim was to investigate if increasing percentiles of FEV1:FVC were associated with any respiratory symptom (cough with phlegm, dyspnoea or wheezing) in a general population sample of never-smokers and ever-smokers. METHODS: In a cross-sectional study comprising 15 128 adults (50-64 years), 7120 never-smokers and 8008 ever-smokers completed a respiratory questionnaire and performed FEV1 and FVC after bronchodilation. We calculated their z-scores for FEV1:FVC and defined the fifth percentile using the Global Lung Function Initiative (GLI) reference value, GLI5 and increasing percentiles up to GLI25. We analysed the associations between different strata of percentiles and prevalence of any respiratory symptom using multivariable logistic regression for estimation of OR. RESULTS: Among all subjects, regardless of smoking habits, the odds of any respiratory symptom were elevated up to the GLI15-20 strata. Among never-smokers, the odds of any respiratory symptom were elevated at GLI<5 (OR 3.57, 95% CI 2.43 to 5.23) and at GLI5-10 (OR 2.57, 95% CI 1.69 to 3.91), but not at higher percentiles. Among ever-smokers, the odds of any respiratory symptom were elevated from GLI<5 (OR 4.64, 95% CI 3.79 to 5.68) up to GLI≥25 (OR 1.33, 95% CI 1.00 to 1.75). CONCLUSIONS: The association between percentages of FEV1:FVC and respiratory symptoms differed depending on smoking history. Our results support a higher percentile cut-off for FEV1:FVC for never-smokers and, in particular, for ever-smokers.


Assuntos
Pulmão/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Fumantes , Fumar/fisiopatologia , Estudos Transversais , Feminino , Volume Expiratório Forçado , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Prevalência , Espirometria , Inquéritos e Questionários , Suécia/epidemiologia , Capacidade Vital
9.
Eur Respir J ; 56(2)2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32341107

RESUMO

The Global Lung Function Initiative (GLI) has recently published international reference values for diffusing capacity of the lung for carbon monoxide (D LCO). Lower limit of normal (LLN), i.e. the 5th percentile, usually defines impaired D LCO We examined if the GLI LLN for D LCO differs from the LLN in a Swedish population of healthy, never-smoking individuals and how any such differences affect identification of subjects with respiratory burden.Spirometry, D LCO, chest high-resolution computed tomography (HRCT) and questionnaires were obtained from the first 15 040 participants, aged 50-64 years, of the Swedish CArdioPulmonary bioImage Study (SCAPIS). Both GLI reference values and the lambda-mu-sigma (LMS) method were used to define the LLN in asymptomatic never-smokers without respiratory disease (n=4903, of which 2329 were women).Both the median and LLN for D LCO from SCAPIS were above the median and LLN from the GLI (p<0.05). The prevalence of D LCO GLI LLN but GLI LLN but GLI LLN and >SCAPIS LLN). No differences were found with regard to physician-diagnosed asthma.The GLI LLN for D LCO is lower than the estimated LLN in healthy, never-smoking, middle-aged Swedish adults. Individuals with D LCO above the GLI LLN but below the SCAPIS LLN had, to a larger extent, an increased respiratory burden. This suggests clinical implications for choosing an adequate LLN for studied populations.


Assuntos
Pulmão , Adulto , Feminino , Volume Expiratório Forçado , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Valores de Referência , Espirometria , Suécia/epidemiologia , Capacidade Vital
10.
Acad Radiol ; 27(5): 636-643, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31326310

RESUMO

RATIONALE AND OBJECTIVES: Emphysema is a hallmark of chronic obstructive pulmonary disease. The primary aim of this study was to investigate inter- and intraobserver agreement of visual assessment of mild emphysema in low-dose multidetector computed tomography of subjects in the pilot SCAPIS in order to certify consistent detection of mild emphysema. The secondary aim was to investigate the performance of quantitative densitometric measurements in the cohort. MATERIALS AND METHODS: Participants with emphysema (n = 100, 56 males and 44 females) reported in the electronic case report form of pilot SCAPIS and 100 matched controls (gender, age, height, and weight) without emphysema were included. To assess interobserver variability the randomized examinations were evaluated by two thoracic radiologists. For intraobserver variability three radiologists re-evaluated randomized examinations which they originally evaluated. The results were evaluated statistically by Krippendorff's α. The dataset was also assessed quantitively for % lung attenuation value -950 HU (LAV950), mean lung density and total lung volume by commercially available software. RESULTS: Emphysema was visually scored as mild and Krippendorff's α was ≥0.8 for both the inter- and intraobserver agreement regarding presence of emphysema and approaching 0.8 regarding presence and extent of emphysema by location in the upper lobes. Mean LAV950 was not different between the emphysematous and the nonemphysematous participants; 8.3% and 8.4%, respectively. CONCLUSION: The inter- and intraobserver agreement for visual detection of mild emphysema in low-dose multidetector computed tomography was good. Surprisingly, quantitative analysis could not reliably identify participants with mild emphysema, which hampers the use of automatic evaluation.


Assuntos
Pulmão/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Enfisema Pulmonar/diagnóstico por imagem , Estudos de Casos e Controles , Enfisema , Feminino , Humanos , Masculino , Projetos Piloto , Doença Pulmonar Obstrutiva Crônica , Suécia
12.
Acad Radiol ; 26(4): 508-518, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-29903641

RESUMO

RATIONALE AND OBJECTIVES: Chest tomosynthesis has been suggested as a suitable alternative to CT for follow-up of pulmonary nodules. The aim of the present study was to investigate the possibility of detecting pulmonary nodule growth using chest tomosynthesis. MATERIALS AND METHODS: Simulated nodules with volumes of approximately 100 mm3 and 300 mm3 as well as additional versions with increasing volumes were created. The nodules were inserted into images from pairs of chest tomosynthesis examinations, simulating cases where the nodule had either remained stable in size or increased in size between the two imaging occasions. Nodule volume growths ranging from 11% to 252% were included. A simulated dose reduction was applied to a subset of the cases. Cases differing in terms of nodule size, dose level, and nodule position relative to the plane of image reconstruction were included. Observers rated their confidence that the nodules were stable in size or not. The rating data for the nodules that were stable in size was compared to the rating data for the nodules simulated to have increased in size using ROC analysis. RESULTS: Area under the curve values ranging from 0.65 to 1 were found. The lowest area under the curve values were found when there was a mismatch in nodule position relative to the reconstructed image plane between the two examinations. Nodule size and dose level affected the results. CONCLUSION: The study indicates that chest tomosynthesis can be used to detect pulmonary nodule growth. Nodule size, dose level, and mismatch in position relative to the image reconstruction plane in the baseline and follow-up examination may affect the precision.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Torácica/métodos , Reprodutibilidade dos Testes , Carga Tumoral
13.
Radiology ; 287(3): 1018-1027, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29613826

RESUMO

Purpose To investigate the performance of digital tomosynthesis (DTS) for detection and characterization of incidental solid lung nodules. Materials and Methods This prospective study was based on a population study with 1111 randomly selected participants (age range, 50-64 years) who underwent a medical evaluation that included chest computed tomography (CT). Among these, 125 participants with incidental nodules 5 mm or larger were included in this study, which added DTS in conjunction with the follow-up CT and was performed between March 2012 and October 2014. DTS images were assessed by four thoracic radiologists blinded to the true number of nodules in two separate sessions according to the 5-mm (125 participants) and 6-mm (55 participants) cut-off for follow-up of incidental nodules. Pulmonary nodules were directly marked on the images by the readers and graded regarding confidence of presence and recommendation for follow-up. Statistical analyses included jackknife free-response receiver operating characteristic, receiver operating characteristic, and Cohen κ coefficient. Results Overall detection rate ranges of CT-proven nodules 5 mm or larger and 6 mm or larger were, respectively, 49%-58% and 48%-62%. Jackknife free-response receiver operating characteristics figure of merit for detection of CT-proven nodules 5 mm or larger and 6 mm or larger was 0.47 and 0.51, respectively, and area under the receiver operating characteristic curve regarding recommendation for follow-up was 0.62 and 0.65, respectively. Conclusion Routine use of DTS would result in lower detection rates and reduced number of small nodules recommended for follow-up. © RSNA, 2018.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suécia
14.
Int J Chron Obstruct Pulmon Dis ; 12: 3407-3413, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29238185

RESUMO

BACKGROUND: The aim of this study was to estimate the occupational burden of airflow limitation, chronic airflow limitation, COPD, and emphysema. MATERIALS AND METHODS: Subjects aged 50-64 years (n=1,050) were investigated with forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC). Airflow limitation was defined as FEV1/FVC <0.7 before bronchodilation. Chronic airflow limitation was defined after bronchodilation either according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) as FEV1/FVC <0.7 or according to the lower limit of normal (LLN) approach as FEV1/FVC < LLN. COPD was defined as chronic airflow limitation (GOLD) in combination with dyspnea, wheezing, or chronic bronchitis. Emphysema was classified according to findings from computed tomography of the lungs. Occupational exposure was defined as self-reported occupational exposure to vapor, gas, dust, or fumes (VGDF). Odds ratios (OR) were calculated in models adjusted for age, gender, and smoking; population-attributable fractions and 95% CI were also calculated. RESULTS: There were significant associations between occupational exposure to VGDF and COPD (OR 2.7, 95% CI 1.4-51), airflow limitation (OR 1.8, 95% CI 1.3-2.5), and emphysema (OR 1.8, 95% CI 1.1-3.1). The associations between occupational exposure to VGDF and chronic airflow limitation were weaker, and for the OR, the CIs included unity. The population-attributable fraction for occupational exposure to VGDF was 0.37 (95% CI 0.23-0.47) for COPD and 0.23 (95% CI 0.05-0.35) for emphysema. CONCLUSION: The occupational burden of COPD and computed tomography-verified emphysema is substantial.


Assuntos
Poluentes Ocupacionais do Ar/efeitos adversos , Poeira , Gases/efeitos adversos , Pulmão/efeitos dos fármacos , Doenças Profissionais/induzido quimicamente , Exposição Ocupacional/efeitos adversos , Saúde Ocupacional , Doença Pulmonar Obstrutiva Crônica/induzido quimicamente , Enfisema Pulmonar/induzido quimicamente , Distribuição de Qui-Quadrado , Estudos Transversais , Monitoramento Ambiental , Feminino , Volume Expiratório Forçado , Humanos , Modelos Logísticos , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Doenças Profissionais/diagnóstico , Doenças Profissionais/epidemiologia , Doenças Profissionais/fisiopatologia , Razão de Chances , Projetos Piloto , Prevalência , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Enfisema Pulmonar/diagnóstico , Enfisema Pulmonar/epidemiologia , Enfisema Pulmonar/fisiopatologia , Medição de Risco , Fatores de Risco , Espirometria , Inquéritos e Questionários , Suécia/epidemiologia , Tomografia Computadorizada por Raios X , Capacidade Vital , Volatilização
15.
Acta Radiol ; 58(4): 408-413, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27382042

RESUMO

Background A method of simulating pulmonary nodules in tomosynthesis images has previously been developed and evaluated. An unknown feature of a rounding function included in the computer code was later found to introduce an artifact, affecting simulated nodules in low-signal regions of the images. The computer code has now been corrected. Purpose To perform a thorough evaluation of the corrected nodule-simulation method, comparing the detection rate and visual appearance of artificial nodules with those of real nodules in an observer performance experiment. Material and Methods A cohort of 64 patients with a total of 129 pulmonary nodules was used in the study. Artificial nodules, each matching a corresponding real nodule by size, attenuation, and anatomical location, were generated and simulated into the tomosynthesis images of the different patients. The detection rate and visual appearance of artificial nodules generated using both the corrected and uncorrected computer code were compared to those of real nodules. The results were evaluated using modified receiver operating characteristic (ROC) analyses. Results The difference in detection rate between artificial and real nodules slightly increased using the corrected computer code (uncorrected code: area under the curve [AUC], 0.47; 95% CI, 0.43-0.51; corrected code: AUC, 0.42; 95% CI, 0.38-0.46). The visual appearance was however substantially improved using the corrected computer code (uncorrected code: AUC, 0.70; 95% CI, 0.63-0.76; corrected code: AUC, 0.49; 95% CI, 0.29-0.65). Conclusion The computer code including a correct rounding function generates simulated nodules that are more visually realistic than simulated nodules generated using the uncorrected computer code, but have a slightly different detection rate compared to real nodules.


Assuntos
Simulação por Computador , Neoplasias Pulmonares/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Área Sob a Curva , Artefatos , Humanos , Curva ROC , Reprodutibilidade dos Testes
16.
Radiology ; 282(1): 236-250, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27439324

RESUMO

Purpose To conduct a multi-institutional, multireader study to compare the performance of digital tomosynthesis, dual-energy (DE) imaging, and conventional chest radiography for pulmonary nodule detection and management. Materials and Methods In this binational, institutional review board-approved, HIPAA-compliant prospective study, 158 subjects (43 subjects with normal findings) were enrolled at four institutions. Informed consent was obtained prior to enrollment. Subjects underwent chest computed tomography (CT) and imaging with conventional chest radiography (posteroanterior and lateral), DE imaging, and tomosynthesis with a flat-panel imaging device. Three experienced thoracic radiologists identified true locations of nodules (n = 516, 3-20-mm diameters) with CT and recommended case management by using Fleischner Society guidelines. Five other radiologists marked nodules and indicated case management by using images from conventional chest radiography, conventional chest radiography plus DE imaging, tomosynthesis, and tomosynthesis plus DE imaging. Sensitivity, specificity, and overall accuracy were measured by using the free-response receiver operating characteristic method and the receiver operating characteristic method for nodule detection and case management, respectively. Results were further analyzed according to nodule diameter categories (3-4 mm, >4 mm to 6 mm, >6 mm to 8 mm, and >8 mm to 20 mm). Results Maximum lesion localization fraction was higher for tomosynthesis than for conventional chest radiography in all nodule size categories (3.55-fold for all nodules, P < .001; 95% confidence interval [CI]: 2.96, 4.15). Case-level sensitivity was higher with tomosynthesis than with conventional chest radiography for all nodules (1.49-fold, P < .001; 95% CI: 1.25, 1.73). Case management decisions showed better overall accuracy with tomosynthesis than with conventional chest radiography, as given by the area under the receiver operating characteristic curve (1.23-fold, P < .001; 95% CI: 1.15, 1.32). There were no differences in any specificity measures. DE imaging did not significantly affect nodule detection when paired with either conventional chest radiography or tomosynthesis. Conclusion Tomosynthesis outperformed conventional chest radiography for lung nodule detection and determination of case management; DE imaging did not show significant differences over conventional chest radiography or tomosynthesis alone. These findings indicate performance likely achievable with a range of reader expertise. © RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/terapia , Intensificação de Imagem Radiográfica/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Radiografia Torácica , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Suécia , Tomografia Computadorizada por Raios X , Estados Unidos , Ecrans Intensificadores para Raios X
17.
Artigo em Inglês | MEDLINE | ID: mdl-27194908

RESUMO

BACKGROUND: Spirometric diagnosis of chronic obstructive pulmonary disease (COPD) is based on the ratio of forced expiratory volume in 1 second (FEV1)/vital capacity (VC), either as a fixed value <0.7 or below the lower limit of normal (LLN). Forced vital capacity (FVC) is a proxy for VC. The first aim was to compare the use of FVC and VC, assessed as the highest value of FVC or slow vital capacity (SVC), when assessing the FEV1/VC ratio in a general population setting. The second aim was to evaluate the characteristics of subjects with COPD who obtained a higher SVC than FVC. METHODS: Subjects (n=1,050) aged 50-64 years were investigated with FEV1, FVC, and SVC after bronchodilation. Global Initiative for Chronic Obstructive Lung Disease (GOLD) COPDFVC was defined as FEV1/FVC <0.7, GOLDCOPDVC as FEV1/VC <0.7 using the maximum value of FVC or SVC, LLNCOPDFVC as FEV1/FVC below the LLN, and LLNCOPDVC as FEV1/VC below the LLN using the maximum value of FVC or SVC. RESULTS: Prevalence of GOLDCOPDFVC was 10.0% (95% confidence interval [CI] 8.2-12.0) and the prevalence of LLNCOPDFVC was 9.5% (95% CI 7.8-11.4). When estimates were based on VC, the prevalence became higher; 16.4% (95% CI 14.3-18.9) and 15.6% (95% CI 13.5-17.9) for GOLDCOPDVC and LLNCOPDVC, respectively. The group of additional subjects classified as having COPD based on VC, had lower FEV1, more wheeze and higher residual volume compared to subjects without any COPD. CONCLUSION: The prevalence of COPD was significantly higher when the ratio FEV1/VC was calculated using the highest value of SVC or FVC compared with using FVC only. Subjects classified as having COPD when using the VC concept were more obstructive and with indications of air trapping. Hence, the use of only FVC when assessing airflow limitation may result in a considerable under diagnosis of subjects with mild COPD.


Assuntos
Volume Expiratório Forçado , Pulmão/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Espirometria , Capacidade Vital , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevalência , Doença Pulmonar Obstrutiva Crônica/classificação , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Suécia/epidemiologia , Fatores de Tempo
18.
Radiat Prot Dosimetry ; 169(1-4): 188-98, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26994093

RESUMO

The aim of the present study was to investigate the dependency of the accuracy and precision of nodule diameter measurements on the radiation dose level in chest tomosynthesis. Artificial ellipsoid-shaped nodules with known dimensions were inserted in clinical chest tomosynthesis images. Noise was added to the images in order to simulate radiation dose levels corresponding to effective doses for a standard-sized patient of 0.06 and 0.04 mSv. These levels were compared with the original dose level, corresponding to an effective dose of 0.12 mSv for a standard-sized patient. Four thoracic radiologists measured the longest diameter of the nodules. The study was restricted to nodules located in high-dose areas of the tomosynthesis projection radiographs. A significant decrease of the measurement accuracy and intraobserver variability was seen for the lowest dose level for a subset of the observers. No significant effect of dose level on the interobserver variability was found. The number of non-measurable small nodules (≤5 mm) was higher for the two lowest dose levels compared with the original dose level. In conclusion, for pulmonary nodules at positions in the lung corresponding to locations in high-dose areas of the projection radiographs, using a radiation dose level resulting in an effective dose of 0.06 mSv to a standard-sized patient may be possible in chest tomosynthesis without affecting the accuracy and precision of nodule diameter measurements to any large extent. However, an increasing number of non-measurable small nodules (≤5 mm) with decreasing radiation dose may raise some concerns regarding an applied general dose reduction for chest tomosynthesis examinations in the clinical praxis.


Assuntos
Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Simulação por Computador , Humanos , Pulmão/diagnóstico por imagem , Variações Dependentes do Observador , Radiologia/métodos , Reprodutibilidade dos Testes , Tórax/diagnóstico por imagem
19.
Radiat Prot Dosimetry ; 169(1-4): 165-70, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26979807

RESUMO

The aim of the study was to investigate the potential role of chest tomosynthesis (CTS) at a tertiary referral centre by exploring to what extent CTS could substitute chest radiography (CXR) and computed tomography (CT). The study comprised 1433 CXR, 523 CT and 216 CTS examinations performed 5 years after the introduction of CTS. For each examination, it was decided if CTS would have been appropriate instead of CXR (CXR cases), if CTS could have replaced the performed CT (CT cases) or if CT would have been performed had CTS not been available (CTS cases). It was judged that (a) CTS had been appropriate in 15 % of the CXR examinations, (b) CTS could have replaced additionally 7 % of the CT examinations and (c) CT would have been carried out in 63 % of the performed CTS examinations, had CTS not been available. In conclusion, the potential role for CTS to substitute other modalities during office hours at a tertiary referral centre may be in the order of 20 and 25 % of performed CXR and chest CT, respectively.


Assuntos
Radiografia Torácica/métodos , Tórax/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Encaminhamento e Consulta , Reprodutibilidade dos Testes , Centros de Atenção Terciária , Adulto Jovem
20.
Radiat Prot Dosimetry ; 169(1-4): 204-10, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26868012

RESUMO

The aim of the present study was to evaluate digital tomosynthesis (DTS) in thoracic spine imaging, comparing the reproduction of anatomical structures with that achieved using digital radiography (DR). In a prospective visual grading study, 23 patients referred in 2014 for elective radiographic examination of the thoracic spine were examined using lateral DR and DTS. The DR image and the DTS section images were read in random order by four radiologists, evaluating the ability of the modalities to present a clear reproduction of nine specific relevant structures of the thoracic vertebrae 3, 6 and 9 (T3, T6 and T9). The data were analysed using visual grading characteristics (VGC) analysis. The VGC analysis revealed a statistically significant difference in favour of DTS for all evaluated structures, except for the anterior vertebral edges and lower end plate surfaces of T6 and T9 and the cancellous bone of T9. The difference was most striking in T3 and for posterior structures. For no structure in any vertebra was the reproduction rated significantly better for DR. In conclusion, DTS of the thoracic spine appears to be a promising alternative to DR, especially in areas where the problem of overlaying anatomy is accentuated, such as posterior and upper thoracic structures.


Assuntos
Intensificação de Imagem Radiográfica/métodos , Radiografia/métodos , Vértebras Torácicas/diagnóstico por imagem , Parede Torácica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Software , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...