Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Jpn J Radiol ; 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38504000

RESUMO

PURPOSE: This study aimed to determine the organ-specific accuracy of [18F]FDG-PET/CT in identifying immune-related adverse events (irAEs) in patients with high-risk (stage III/IV) surgically resected melanoma treated with an adjuvant immune checkpoint inhibitor (ICI) and determine the incidence of irAEs within the first year after starting treatment. MATERIALS AND METHODS: This registry-based study included individuals who had undergone surgical removal of melanoma and were undergoing adjuvant ICI treatment (either nivolumab or pembrolizumab). The study specifically enrolled patients who had undergone both a baseline and at least one subsequent follow-up [18F]FDG-PET/CT scan. Follow-up scans were performed every third month in the first year after surgery to screen for disease recurrence. We retrospectively compared the follow-up scans with baseline scans to identify irAEs. Clinical information on irAEs was obtained from medical records and served as a reference standard for determining the accuracy of [18F]FDG-PET/CT. RESULTS: A total of 123 patients with 363 [18F]FDG-PET/CT scans were included, and 65 patients (52.8%) developed irAEs. In decreasing order, the organ-specific incidences of irAEs were: skin 26/65 (40%), muscle and joints 21/65 (32.3%), intestines 13/65 (20%), thyroid gland 12/65 (18.5%), lungs 4/65 (6.2%), and heart 2/65 (3.1%). The sensitivities and specificities of [18F]FDG-PET/CT for diagnosing irAEs were: skin 19% (95% CI: 7-39%) and 95% (88-98%), muscles and joints 71% (48-89%) and 83% (75-90%), intestines 100% (75-100%) and 85% (77-91%); thyroid gland 92% (62-99%) and 95% (89-98%), lungs 75% (19-99%) and 90% (83-95%), and heart 50% (13-99%) and 97% (92-99%), respectively. CONCLUSION: [18F]FDG-PET/CT generally had moderate to high sensitivities (except for skin and heart) and specificities in diagnosing irAEs in patients receiving adjuvant ICI; this could be suggested to be systematically assessed and reported in scan reports.

2.
BJUI Compass ; 4(5): 513-522, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37636207

RESUMO

Background: Prostate-specific membrane antigen (PSMA)-positron emission tomography/contrast-enhanced computed tomography (PET/CT) is a sensitive imaging modality for prostate cancer (PCa). Due to lack of knowledge of the patient benefit, PSMA-PET/CT is not yet recommended in the European guidelines for staging and treatment planning of patients with newly diagnosed PCa. We will investigate the potential difference in progression-free survival (PFS) and quality of life (QoL) of using PSMA-PET/CT versus sodium fluoride (NaF)-PET/CT for staging and treatment planning in patients with newly diagnosed PCa. Study Design: This is a prospective randomised controlled multicentre trial carried out at three centres in the Region of Southern Denmark. Endpoints: The primary endpoint is PFS. Secondary endpoints are residual disease, stage migration, impact on treatment strategies, stage distribution, QoL and diagnostic accuracy measures. Patients and Methods: Patients eligible for the study have newly diagnosed unfavourable intermediate- or high-risk PCa. A total of 448 patients will be randomised 1:1 into two groups: (A) a control group staged with Na[18F]F-PET/CT and (B) an intervention group staged with [18F]PSMA-1007-PET/CT. A subgroup in the intervention group will have a supplementary blinded Na[18F]F-PET/CT performed for the purpose of performing accuracy analyses. QoL will be assessed at baseline and with regular intervals (3-12 months) during the study period. Treatment decisions are achieved at multidisciplinary team conferences based on the results of the respective scans and according to current Danish guidelines. Trial Registration: The Regional Committees on Health Research Ethics for Southern Denmark (S-20190161) and the Danish Medicines Agency (EudraCT Number 2021-000123-12) approved the study, and it has been registered on clinicaltrials.gov (Record 2020110469).

3.
J Imaging ; 9(3)2023 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-36976116

RESUMO

We compared the image quality and quantification parameters through bayesian penalized likelihood reconstruction algorithm (Q.Clear) and ordered subset expectation maximization (OSEM) algorithm for 2-[18F]FDG-PET/CT scans performed for response monitoring in patients with metastatic breast cancer in prospective setting. We included 37 metastatic breast cancer patients diagnosed and monitored with 2-[18F]FDG-PET/CT at Odense University Hospital (Denmark). A total of 100 scans were analyzed blinded toward Q.Clear and OSEM reconstruction algorithms regarding image quality parameters (noise, sharpness, contrast, diagnostic confidence, artefacts, and blotchy appearance) using a five-point scale. The hottest lesion was selected in scans with measurable disease, considering the same volume of interest in both reconstruction methods. SULpeak (g/mL) and SUVmax (g/mL) were compared for the same hottest lesion. There was no significant difference regarding noise, diagnostic confidence, and artefacts within reconstruction methods; Q.Clear had significantly better sharpness (p < 0.001) and contrast (p = 0.001) than the OSEM reconstruction, while the OSEM reconstruction had significantly less blotchy appearance compared with Q.Clear reconstruction (p < 0.001). Quantitative analysis on 75/100 scans indicated that Q.Clear reconstruction had significantly higher SULpeak (5.33 ± 2.8 vs. 4.85 ± 2.5, p < 0.001) and SUVmax (8.27 ± 4.8 vs. 6.90 ± 3.8, p < 0.001) compared with OSEM reconstruction. In conclusion, Q.Clear reconstruction revealed better sharpness, better contrast, higher SUVmax, and higher SULpeak, while OSEM reconstruction had less blotchy appearance.

4.
J Clin Imaging Sci ; 13: 37, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38205274

RESUMO

Objectives: The objective of this study was to investigate renal function after robot-assisted partial nephrectomy (RAPN) and percutaneous cryoablation (PCA) in clinical stage T1 (cT1) renal cell carcinoma (RCC) and evaluate the relationship between baseline renal function and renal functional outcome. Material and Methods: Patients with cT1 RCC treated with RAPN or PCA were prospectively enrolled between June 2019 and January 2021. Renal function was evaluated using estimated glomerular filtration rate, Tc-99m diethylenetriamine-pentaacetate plasma clearance, Tc-99m mercaptoacetyltriglycine renography, and renal volume at baseline and 6 months after treatment. Results: Fifty-six patients were included (18 RAPN, 38 PCA). PCA patients had a significantly higher age (68.5 years; P = 0.019) and Charlson comorbidity index (3.0; P = 0.007). Tumor characteristics did not differ significantly between RAPN and PCA. Total renal volume decreased significantly after PCA (-18.2 cm3; P = 0.001). Baseline chronic disease stage IIIb-IV leads to a greater reduction in renal volume (-31.8 cm3; P = 0.003) but not other renal function measures. Renal function declined significantly after either treatment without significant differences between RAPN and PCA. Conclusion: This study found a small, similar decrease in renal function 6 months after RAPN or PCA, despite significant differences in baseline patient characteristics. Reduced renal function at baseline did not lead to a worse renal functional outcome.

5.
Gynecol Oncol ; 167(2): 152-158, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36182533

RESUMO

OBJECTIVE: Staging carcinoma of the uterine cervix (CCU) by FIGO-2018 suggests stage migration of FIGO-2009 stage I-III patients with lymph node metastasis into FIGO-2018 stage IIIC. We aimed to investigate the prognostic value of lymph node metastases identified by imaging. METHODS: We enrolled all patients with biopsy-verified CCU from 2007 to 2016 at Odense University Hospital, Denmark. FDG-PET/CT and MRI were performed before clinical examination in general anesthesia. Disease-specific mortality was compared between women with lymph node-positive and lymph node-negative imaging. RESULTS: In total, 488 patients underwent clinical staging according to FIGO-2009. Lymph node-positive imaging was identified in 146 (30%) patients: 0/36 (0%) in stage IA, 22/195 (11%) in IBI, 14/30 (47%) in IB2, 70/164 (43%) in II and 40/63 (63%) in III. The 5-year cumulative incidence of death due to CCU lymph node-negative vs. lymph node-positive patients was 0.8% vs. 7.1% (p = 0.034) in stage IBI, 0% vs. 34.5% (p = 0.003) in stage IB2, 15.1% vs. 41.4% (p < 0.0001) in stage II, and 33.3% vs. 46.6% (p = 0.28) in stage III by FIGO-2009. CONCLUSIONS: One of three women with FIGO-2009 stage I-III CCU had suspected lymph node metastasis on imaging and is upstaged to stage IIIC according to FIGO-2018. The cancer-specific mortality by CCU was significantly lower in the lymph node-negative women stages IBI-II, thus supporting stage migration due to suspected lymph node metastasis. However, the exact prognostic value within stage IIIC is challenged, and future revision of FIGO stages may include new sub-stages.


Assuntos
Neoplasias do Colo do Útero , Neoplasias Uterinas , Humanos , Feminino , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Metástase Linfática/patologia , Estadiamento de Neoplasias , Estudos Retrospectivos , Neoplasias Uterinas/patologia , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Imageamento por Ressonância Magnética
6.
Gynecol Oncol ; 162(3): 546-554, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34226018

RESUMO

OBJECTIVES: Sentinel lymph node (SLN) mapping may replace staging radical pelvic lymphadenectomy in women with early-stage cervical cancer. In a national multicenter setting, we evaluated SLN mapping in women with early-stage cervical cancer and investigated the accuracy of SLN mapping and FDG-PET/CT in tumors >20 mm. METHODS: We prospectively included women with early-stage cervical cancer from March 2017-January 2021 to undergo SLN mapping. Women with tumors >20 mm underwent completion pelvic lymphadenectomy and removal of FDG-PET/CT positive nodes. We determined SLN detection rates, incidence of nodal disease, sensitivity and negative predictive value (NPV) of SLN mapping, and the sensitivity, specificity, NPV, and positive predictive value (PPV) of FDG-PET/CT. RESULTS: We included 245 women, and 38 (15.5%) had nodal metastasis. The SLN detection rate was 96.3% (236/245), with 82.0% (201/245) bilateral detection. In a stratified analysis of 103 women with tumors >20 mm, 27 (26.2%) had nodal metastases. The sensitivity of SLN mapping adhering to the algorithm was 96.3% (95% CI 81.0-99.9%) and the NPV 98.7% (95% CI 93.0-100%). For FDG-PET/CT imaging the sensitivity was 14.8% (95% CI 4.2-33.7%), the specificity 85.5% (95% CI 75.6-92.5%), the NPV 73.9% (95% CI 63.4-82.7%), and the PPV 26.7% (95% CI 7.8-55.1%). CONCLUSIONS: SLN mapping seems to be an adequate staging procedure in early-stage cervical cancer tumors ≤20 mm. In tumors >20 mm, SLN mapping is highly sensitive but demands full adherence to the SLN algorithm. We recommend completion pelvic lymphadenectomy in tumors >20 mm until the oncological safety is established. FDG-PET/CT for nodal staging of women with early-stage cervical cancer seems limited.


Assuntos
Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/patologia , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluordesoxiglucose F18 , Humanos , Verde de Indocianina , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Prospectivos , Compostos Radiofarmacêuticos
7.
Eur J Nucl Med Mol Imaging ; 48(2): 584-591, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32719914

RESUMO

BACKGROUND: The use of hybrid PET/MRI for clinical staging is growing in several cancer forms and, consequently, PET/MRI has also gained interest in the assessment of non-small cell lung cancer (NSCLC) and lung lesions. However, lung evaluation with PET/MRI is associated with challenges related to technical issues and diagnostic image quality. We, therefore, investigated the published literature on PET/MRI for clinical staging in NSCLC or lung nodule detection specifically addressing diagnostic accuracy and technical issues. METHODS: The data originates from a systematic search performed in PubMed/MEDLINE, Embase, and Cochrane Library on hybrid PET/MRI in patients with cancer for a scoping review published earlier ( https://doi.org/10.1007/s00259-019-04402-8 ). Studies in English and German evaluating the diagnostic performance of hybrid PET/MRI for NSCLC or lung nodule detection in cancer patients were selected. Data reported in peer-reviewed journals without restrictions to year of publication were included. RESULTS: A total of 3138 publications were identified from which 116 published 2012-2018 were included. Of these, nine studies addressed PET/MRI in NSCLC (4) or lung nodule detection (5). Overall, PET/MRI did not provide advantages in preoperative T- and N-staging in NSCLC compared to PET/CT. The data on M-staging were too few for conclusions to be drawn. The lung nodule detection rate of PET/MRI was comparable to that of PET/CT for FDG-avid nodules larger than 10 mm, but the sensitivity of PET/MRI for detection of non-FDG-avid nodules smaller than 5 mm was low. CONCLUSION: PET/MRI did not provide advantages in T- and N-staging of NSCLC compared to PET/CT. PET/MRI had a comparable sensitivity for detection of FDG-avid lung nodules and nodules over 10 mm, but PET/CT yielded a higher detection rate in non FDG-avid lung nodules under 5 mm. With PET/MRI, the overall detection rate for lung nodules in various cancer types remains inferior to that of PET/CT due to the lower diagnostic performance of MRI than CT in the lungs.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/patologia , Fluordesoxiglucose F18 , Humanos , Pulmão/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Imageamento por Ressonância Magnética , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
8.
Cancers (Basel) ; 11(8)2019 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-31443324

RESUMO

While current international guidelines include imaging of the target lesion for response monitoring in metastatic breast cancer, they do not provide specific recommendations for choice of imaging modality or response criteria. This is important as clinical decisions may vary depending on which imaging modality is used for monitoring metastatic breast cancer. FDG-PET/CT has shown high accuracy in diagnosing metastatic breast cancer, and the Positron Emission Tomography Response Criteria in Solid Tumors (PERCIST) have shown higher predictive values than the CT-based Response Evaluation Criteria in Solid Tumors (RECIST) for prediction of progression-free survival. No studies have yet addressed the clinical impact of using different imaging modalities or response evaluation criteria for longitudinal response monitoring in metastatic breast cancer. We present a case study of a patient with metastatic breast cancer who was monitored first with conventional CT and then with FDG-PET/CT. We retrospectively applied PERCIST to evaluate the longitudinal response to treatment. We used the one-lesion PERCIST model measuring SULpeak in the hottest metastatic lesion on consecutive scans. This model provides a continuous variable that allows graphical illustration of disease fluctuation along with response categories. The one-lesion PERCIST approach seems able to reflect molecular changes and has the potential to support clinical decision-making. Prospective clinical studies addressing the clinical impact of PERCIST in metastatic breast cancer are needed to establish evidence-based recommendations for response monitoring in this disease.

9.
Eur J Nucl Med Mol Imaging ; 46(10): 2138-2151, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31267161

RESUMO

PURPOSE: PET/MRI was introduced for clinical use in 2011 and is now an established modality for the imaging of brain and certain pelvic cancers, whereas clinical use for the imaging of other forms of cancer is not yet widespread. We therefore systematically investigated what has been published on the use of PET/MRI compared to PET/CT in the imaging of cancers outside the brain, focusing on clinical areas of application related to diagnosis, staging and restaging. METHODS: A systematic search of PubMed/MEDLINE, Embase and the Cochrane Library was performed. Studies evaluating the diagnostic performance of simultaneous PET/MRI in cancer patients were chosen. RESULTS: A total of 3,138 publications were identified and 116 published during the period 2012-2018 were included and were grouped according to the major cancer forms: 13 head and neck (HNC), 9 breast (BC), 21 prostate (PC), 14 gynaecological, 13 gastrointestinal (GIC), and 46 various cancers. Data from studies comparing PET/MRI and PET/CT for staging/restaging suggested the superiority of 18F-FDG PET/MRI for the detection of tumour extension and retropharyngeal lymph node metastases in nasopharyngeal cancer, and for the detection of liver metastases and possibly bone marrow metastases in high-risk BC. FDG PET/MRI tended to be inferior for the detection of lung metastases in HNC and BC. 68Ga-PSMA-11 PET/MRI was superior to PET/CT for the detection of local PC recurrence. FDG PET/MRI was superior to FDG PET/CT for the detection of local tumour invasion in cervical cancer and had higher accuracy for the detection of liver metastases in colorectal cancer. CONCLUSION: The scoping review methodology resulted in the identification of a huge number of records, of which less than 5% were suitable for inclusion and only a limited number allowed conclusions on the advantages/disadvantages of PET/MRI compared to PET/CT in the oncological setting. There was evidence to support the use of FDG PET/MRI in staging of nasopharyngeal cancer and high-risk BC. Preliminary data indicate the superiority of PET/MRI for the detection of local recurrence in PC, local tumour invasion in cervical cancer, and liver metastases in colorectal cancer. These conclusions are based on small datasets and need to be further explored.


Assuntos
Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Ácido Edético/análogos & derivados , Fluordesoxiglucose F18 , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Imageamento por Ressonância Magnética/normas , Imagem Multimodal/normas , Metástase Neoplásica , Neoplasias/patologia , Oligopeptídeos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Valor Preditivo dos Testes , Compostos Radiofarmacêuticos
10.
Mol Imaging Biol ; 21(2): 375-381, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-29987620

RESUMO

PURPOSE: Malignant cells exhibit increased rates of aerobic glycolysis. Here, we tested whether the accumulation of fluoro-deoxyglucose-6-phosphate (FDG6P) in ovarian cancers of differential malignancy reflects inversely correlated elevations of hexokinase (HK) and glucose-6-phosphatase (G6Pase) activities. PROCEDURES: Twenty-nine women with suspected ovarian cancer had positron emission tomography (PET) prior to surgery. From fresh-frozen tissue, we determined the activities of HK and G6Pase, and from the PET images, we determined the tumor maximum standardized uptake value (SUVmax) of 2-deoxy-2-[18F]fluoro-D-glucose. RESULTS: The SUVmax of malignant lesions significantly exceeded the SUVmax of benign (p < 0.005) and borderline lesions (p < 0.0005) that did not differ significantly. We found no significant correlation between measured HK or G6Pase activities and histological tumor type or SUVmax except that G6Pase activities were higher in malignant than borderline lesions (p < 0.05). Measured HK and G6Pase activities correlated inversely (p < 0.05). The slopes from the regression lines of the three correlations yielded positively correlated abscissa and ordinate intercepts, designated HKmax and G6Pasemax, respectively (r = 0.67, p < 0.0001). The positive correlations between the abscissa and ordinate intercepts with SUVmax had regression coefficients of r = 0.44, p < 0.05; and r = 0.39, p < 0.05, respectively. CONCLUSIONS: The results distinguished two ovarian cancer phenotypes, one with elevated HK activity and low G6Pase activity, and another with the opposite characteristics.


Assuntos
Glucose-6-Fosfatase/metabolismo , Hexoquinase/metabolismo , Neoplasias Ovarianas/enzimologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluordesoxiglucose F18/farmacocinética , Humanos , Pessoa de Meia-Idade
11.
BMC Res Notes ; 11(1): 871, 2018 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-30526642

RESUMO

OBJECTIVE: This proof of concept study investigated whether dual time point FDG-PET/CT with image acquisition after 1 and 3 h could be useful in preoperative staging of patients undergoing robot-assisted radical prostatectomy and extended pelvic lymph node dissection for high-risk prostate cancer. RESULTS: Twenty patients with high-risk prostate cancer underwent dual time point FDG-PET/CT before undergoing surgery. Histologically confirmed lymph node metastases were found in 9/20 (45%). A median of 19 (range 10-41; n = 434) lymph nodes were removed per patient. Pelvic lymph nodes with detectable FDG uptake were seen in two patients only, but the FDG-avid lesion on PET did not correspond with pathological findings in either patient. We found a significant increase in maximal standardized uptake value of the prostate of around 30% between early and late imaging. We found no correlation between clinical findings after radical prostatectomy and PET measurements.


Assuntos
Fluordesoxiglucose F18/química , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios , Estudos Prospectivos , Neoplasias da Próstata/cirurgia , Fatores de Risco , Fatores de Tempo
12.
Int J Gynecol Cancer ; 27(8): 1675-1684, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28832352

RESUMO

OBJECTIVE: This study aims to ascertain if semiquantitative measurements derived from F-fluorodeoxyglucose positron emission tomography/computed tomography can be used as prognostic markers in patients with newly diagnosed endometrial cancer. MATERIALS AND METHODS: Patients with endometrial cancer and a preoperative F-fluorodeoxyglucose positron emission tomography/computed tomography before curatively intended treatment were included. The scans were evaluated using standard uptake values [maximum standard uptake value (SUVmax) and partial volume corrected (c) mean standardized uptake value (SUVmean)] and whole-body total lesion glycolysis (cTLG). All measurements were analyzed as prognostic factors in relation to overall survival (OS). Receiver operating characteristic curves were performed on all 3 positron emission tomography measurements to find the optimal cut-off for predicting OS. Multivariate Cox proportional regression models were used for prognostic evaluation. RESULTS: Eighty-three patients (median age, 69.9 y; range, 26.8-91.1) with primarily high-risk endometrial cancer or suspected high The International Federation of Gynecology and Obstetrics stage were included. Mean follow-up time was 3.48 years (range, 0.31-6.87), and 24 patients died during follow-up. In multivariate analyses with adjustment for other known prognostic factors, a SUVmax of greater than or equal to 14.3 g/mL and cSUVmean of greater than or equal to 12.7 g/mL of the primary tumor yielded a hazard ratio for OS of 3.18 (1.19-8.49) and 1.93 (0.80-4.68), respectively. Whole-body cTLG of greater than or equal to 176.1 g yielded a hazard ratio of 5.70 (1.94-16.78) for OS in a multivariate analysis. CONCLUSIONS: Preoperative SUVmax and cTLG showed potential as independent prognostic markers of OS in patients with primarily high-risk endometrial cancer. Thus, SUVmax and cTLG might help identify patients who could benefit from a more aggressive treatment strategy or closer surveillance.


Assuntos
Neoplasias do Endométrio/diagnóstico por imagem , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias do Endométrio/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Prognóstico , Modelos de Riscos Proporcionais , Estudos Retrospectivos
13.
BMC Med Imaging ; 16(1): 54, 2016 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-27655353

RESUMO

BACKGROUND: Quantitative measurement procedures need to be accurate and precise to justify their clinical use. Precision reflects deviation of groups of measurement from another, often expressed as proportions of agreement, standard errors of measurement, coefficients of variation, or the Bland-Altman plot. We suggest variance component analysis (VCA) to estimate the influence of errors due to single elements of a PET scan (scanner, time point, observer, etc.) to express the composite uncertainty of repeated measurements and obtain relevant repeatability coefficients (RCs) which have a unique relation to Bland-Altman plots. Here, we present this approach for assessment of intra- and inter-observer variation with PET/CT exemplified with data from two clinical studies. METHODS: In study 1, 30 patients were scanned pre-operatively for the assessment of ovarian cancer, and their scans were assessed twice by the same observer to study intra-observer agreement. In study 2, 14 patients with glioma were scanned up to five times. Resulting 49 scans were assessed by three observers to examine inter-observer agreement. Outcome variables were SUVmax in study 1 and cerebral total hemispheric glycolysis (THG) in study 2. RESULTS: In study 1, we found a RC of 2.46 equalling half the width of the Bland-Altman limits of agreement. In study 2, the RC for identical conditions (same scanner, patient, time point, and observer) was 2392; allowing for different scanners increased the RC to 2543. Inter-observer differences were negligible compared to differences owing to other factors; between observer 1 and 2: -10 (95 % CI: -352 to 332) and between observer 1 vs 3: 28 (95 % CI: -313 to 370). CONCLUSIONS: VCA is an appealing approach for weighing different sources of variation against each other, summarised as RCs. The involved linear mixed effects models require carefully considered sample sizes to account for the challenge of sufficiently accurately estimating variance components.

14.
PET Clin ; 9(4): 391-420, v, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26050944
15.
Eur Radiol ; 21(6): 1277-85, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21274717

RESUMO

OBJECTIVES: We report the 3-year clinical experience of a large new Danish PET/CT centre without capacity limitations in relation to national and European developments. METHODS: The use of PET/CT in cancer was registered from early 2006 to early 2009 to judge the impact on patient management and to compare it with national and European trends. RESULTS: 6056 PET/CT examinations were performed in 4327 patients. Activity increased by 86 examinations per month compared with the same month the year before. Referrals came primarily from oncology (23.0%), haematology (21.6%), surgery (12.6%), internal medicine (12.7%) and gynaecology (5.5%). Referral indications were diagnosis (31.3%), staging (22.3%), recurrence detection (21.2%), response evaluation (17.0%) and other (8.2%). Response from nearly 60% of users showed that PET/CT caused a change in diagnosis and/or staging and/or treatment plan in 36.0% of cases. During the study period, there was a steep increase in the national use of FDG and in the European use of PET/CT. CONCLUSIONS: We recorded a constantly increasing use of PET/CT that caused a change in diagnosis and/or staging and/or treatment plan in 36.0% of cases. In line with national and European trends this may suggest a shift in favour of functional rather than anatomical imaging.


Assuntos
Acessibilidade aos Serviços de Saúde/estatística & dados numéricos , Neoplasias/diagnóstico , Neoplasias/epidemiologia , Tomografia por Emissão de Pósitrons/estatística & dados numéricos , Técnica de Subtração/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Revisão da Utilização de Recursos de Saúde , Dinamarca/epidemiologia , Europa (Continente) , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...