Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 26(18): A737-A749, 2018 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-30184833

RESUMO

Periodic texturing is one of the main techniques for light-trapping in thin-film solar cells. Periodicity allows for the excitation of guided modes in the structure and, thus, largely enhances absorption. Understanding how much a guided resonance can increase the absorption is therefore of great importance. There is a common method to understand if an absorption peak is due to the excitation of a guided mode, using dispersion diagrams. In such graphs, a resonance is identified as the intersection of a guided-mode-line of a uniform waveguide (with the same optical thickness as the grating structure) with the center of a Brillouin zone of the grating. This method is unfortunately not reliable when the grating height is comparable with the thickness of the wave-guide, or when the thickness of the wave-guide is much larger than the wavelength. In this work, we provide a novel approach to calculate the contribution of a guided resonance to the total absorption in a periodic waveguide, without using the dispersion diagram. In this method, the total electric field in the periodic structure is described by its spatial frequencies, using a Fourier expansion. Fourier coefficients of the electric field were used to calculate the absorption of each diffraction order of the grating. Rigorous numerical calculations are provided to support our theoretical approach. This work paves the way for a deeper understanding of light behavior inside a periodic structure and, consequently, for developing more efficient light-trapping techniques for solar cells applications.

2.
Med Eng Phys ; 37(4): 361-6, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25666402

RESUMO

Integration of biological samples into in vitro mock loops is fundamental to simulate real device's operating conditions. We developed an in vitro platform capable of simulating the pumping function of the heart through the external pressurization of the ventricle. The system consists of a fluid-filled chamber, in which the ventricles are housed and sealed to exclude the atria from external loads. The chamber is connected to a pump that drives the motion of the ventricular walls. The aorta is connected to a systemic impedance simulator, and the left atrium to an adjustable preload. The platform reproduced physiologic hemodynamics, i.e. aortic pressures of 120/80 mmHg with 5 L/min of cardiac output, and allowed for intracardiac endoscopy. A pilot study with a left ventricular assist device (LVAD) was also performed. The LVAD was connected to the heart to investigate aortic valve functioning at different levels of support. Results were consistent with the literature, and high speed video recordings of the aortic valve allowed for the visualization of the transition between a fully opening valve and a permanently closed configuration. In conclusion, the system showed to be an effective tool for the hemodynamic assessment of devices, the simulation of surgical or transcatheter procedures and for visualization studies.


Assuntos
Equipamentos e Provisões , Ventrículos do Coração , Modelos Cardiovasculares , Animais , Valva Aórtica/fisiologia , Desenho de Equipamento , Coração Auxiliar , Hemodinâmica , Valva Mitral/fisiologia , Movimento (Física) , Projetos Piloto , Pressão , Suínos , Função Ventricular , Gravação em Vídeo
3.
J Biomech ; 47(2): 329-33, 2014 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-24360769

RESUMO

Aortic interleaflet triangle reshaping (AITR) is a surgical approach to aortic valve incontinence that involves placing three stitches at half of the interleaflet triangles height. In this work, the relationship between the actual stitch height and valve functioning, and the safety margin that the surgeon can rely on in applying the stitches were systematically investigated in vitro. AITR surgery was applied to six swine aortic roots placing the stitches empirically at 50%, 60% and 75% of the triangle heights. Then the actual stitch heights were measured and the hydrodynamic performances were evaluated with a pulsatile hydrodynamic mock loop. Actual stitch heights were 45±2%, 61±4% and 79±6%. As compared to untreated conditions, the 50% configuration induced a significant variation in the effective orifice area. With stitches placed at 60%, the mean systolic pressure drop increased significantly with respect to the untreated case, but no significant changes were recorded with respect to the 50% configuration. At 75%, all the hydrodynamic parameters of systolic valve functioning worsened significantly. Summarizing, the AITR technique, when performed in a conservative manner did not induce significant alterations in the hydrodynamics of the aortic root in vitro, while more aggressive configurations did. The absence of a statistically significant difference between the 50% and 60% configurations suggests that there is a reasonably limited risk of inducing valve stenosis in the post-op scenario due to stitch misplacement.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Animais , Valva Aórtica/fisiologia , Pressão Sanguínea , Humanos , Hidrodinâmica , Técnicas In Vitro , Técnicas de Sutura , Suínos
4.
J Biomech ; 45(7): 1133-9, 2012 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-22387122

RESUMO

Due to their high complexity, surgical approaches to valve repair may benefit from the use of in vitro simulators both for training and for the investigation of those measures which can lead to better clinical results. In vitro tests are intrinsically more effective when all the anatomical substructures of the valvular complexes are preserved. In this work, a mock apparatus able to house an entire explanted porcine heart and subject it to pulsatile fluid-dynamic conditions was developed, in order to enable the hemodynamic analysis of simulated surgical procedures and the imaging of the valvular structures. The mock loop's hydrodynamic design was based on an ad-hoc defined lumped-parameter model. The left ventricle of an entire swine heart was dynamically pressurized by an external computer-controlled pulse duplicator. The ascending aorta was connected to a hydraulic circuit which simulated the input impedance of the systemic circulation; a reservoir passively filled the left atrium. Accesses for endoscopic imaging were located in the apex of the left ventricle and in the aortic root. The experimental pressure and flow tracings were comparable with the typical in vivo curves; a mean flow of 3.5±0.1l pm and a mean arterial pressure of 101±2 mmHg was obtained. High-quality echographic and endoscopic video recordings demonstrated the system's excellent potential in the observation of the cardiac structures dynamics. The proposed mock loop represents a suitable in vitro system for the testing of minimally-invasive cardiovascular devices and surgical procedures for heart valve repair.


Assuntos
Valvas Cardíacas/fisiologia , Valvas Cardíacas/cirurgia , Animais , Fenômenos Biomecânicos , Simulação por Computador , Hemodinâmica , Hidrodinâmica , Técnicas In Vitro , Modelos Animais , Modelos Cardiovasculares , Sus scrofa , Gravação em Vídeo
5.
Ann Biomed Eng ; 39(3): 1024-31, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21203847

RESUMO

Reparative surgery of the aortic root functional unit (ARFU) allows for a better preservation of the functionality of the native structure compared to prosthesis implantation. Post-operative results are satisfactory, whereas mid- and long-term results are challenging, for example in terms of cusps prolapse recurrence. At the Cardiothoracic Surgery Unit of the Sacco Hospital, a new surgical technique aimed at the stabilization in time of the results of standard ARFU repair operations has been applied. This technique, inspired by the mitral neo-chordae (NC) implantation, consists of implanting an e-PTFE suture thread between the prolapsed cusp and the sinotubular junction. Aim of this study was to assess the influence of NC implantation on the ARFU functioning by evaluating with an owned pulsatile in vitro apparatus the force magnitude acting on the NC and the dynamic behavior of porcine ARFUs treated according to the operating-room procedures. The maximum recorded values of the mean and peak diastolic forces were 0.064 and 0.186 N, respectively, and were linearly dependent upon the mean diastolic pressure across the valve. In addition, the measurements of the opening-closing times and valve leakage volumes, performed at pre- and post-surgeries, yielded that the valve functionality was not significantly influenced by NC implantation.


Assuntos
Valva Aórtica/fisiologia , Valva Aórtica/cirurgia , Procedimentos de Cirurgia Plástica/instrumentação , Técnicas de Sutura/instrumentação , Suturas , Animais , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Análise de Falha de Equipamento , Humanos , Desenho de Prótese , Suínos , Resistência à Tração
6.
Sci Total Environ ; 371(1-3): 214-22, 2006 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-16677687

RESUMO

Diffuse pollution is generally indirectly estimated by area and specific emission factors as function of land use. However in many cases these estimates were proven to be remarkably inaccurate. Aim of this study was to combine a water quality simulation model, (USEPA-QUAL2E) and Factor Analysis to increase the understanding of the water pollutants source apportionment. The study concerned two different watersheds, an upland area characterised by a very scarce agricultural use, and another area covering both the upland and the lowland physiographic regions. Particularly the lowland region is included in one of the most productive agricultural areas in Italy. By comparing instream measurements with QUAL2E simulations during dry and wet weather conditions, a good fit (errors +/-20%) was found for the dry weather scenario, whereas very poor was the model performance on the wet weather scenario. This was in the same way expected since the rainfall-driven pollutants scenario deviates significantly from QUAL2E general assumptions of constant emissions in steady state streamflow conditions. However the poor fit was also due to the scarcer reliability of the adopted non point emission estimates. Despite of approximations the model wet weather simulations enabled to estimate the non point contribution to the instream load at the rainfall event scale resolution. Such diffuse sources contribution was found around 80% in the area of extensive agricultural land use, and around 40% in the upland region. Factor Analysis applied to the instream measurements data shed light on the exchange from the groundwater to the surface water system that occurred in the upland region. The hypothesis of a groundwater contribution to the instream total load of nitrates was also supported by QUAL2E simulations that, when considering only the point loads, systematically underestimate the dry weather nitrate concentrations. The same pattern was not observed for the lowland region.


Assuntos
Monitoramento Ambiental/métodos , Modelos Teóricos , Rios/química , Poluentes Químicos da Água/análise , Itália , Controle de Qualidade
7.
Int J Artif Organs ; 28(12): 1232-41, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16404700

RESUMO

A new model lung (ML), designed to reproduce the tracheal pressure vs. fluid flow relationship in animals undergoing total liquid ventilation (TLV) trials, was developed to be used as a mock bench test for neonatal TLV circuits. The ML is based on a linear inertance-resistance-compliance (LRC) lumped-parameter model of the respiratory system with different resistance values for inspiration (R insp ) or expiration (R exp ). The resistant element was set up using polypropylene hollow fibres packed inside a tube. A passive one-way valve was used to control the resistance cross-section area provided for the liquid to generate different values for R insp or R exp , each adjustable by regulating the active length of the respective fibre pack. The compliant element consists of a cylindrical column reservoir, in which bars of different diameter were inserted to adjust compliance (C). The inertial phenomena occurring in the central airways during TLV were reproduced by specifically dimensioned conduits into which the endotracheal tube connecting the TLV circuit to the ML was inserted. A number of elements with different inertances (L) were used to simulate different sized airways. A linear pressure drop-to-flow rate relationship was obtained for flow rates up to 5 l/min. The measured C (0.8 to 1.3 mL cmH2O (-1) kg(-1)), R insp (90 to 850 cmH2O s l(-1)), and R exp (50 to 400 cmH2O s l(-1)) were in agreement with the literature concerning animals weighing from 1 to 12 kg. Moreover, features observed in data acquired during in vivo TLV sessions, such as pressure oscillations due to fluid inertia in the upper airways, were similarly obtained in vitro thanks to the inertial element in the ML.


Assuntos
Ventilação Líquida/instrumentação , Modelos Estruturais , Animais , Desenho de Equipamento , Técnicas In Vitro , Complacência Pulmonar , Coelhos
8.
J Comp Physiol A ; 187(1): 79-81, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11318381

RESUMO

The cnidarian Hydra does not possess identified photoreceptive structures or specialized cells for light detection; nevertheless, it shows a marked photosensitivity. So far no evidence has been previously reported about the localization of the proteins involved in the photoresponse. We used polyclonal antibodies and immunofluorescence microscopy on whole-mount Hydra to identify a putative rhodopsin-like protein. Our results show an immunoreactivity in the ectodermal layer of Hydra, which corresponds in position to the nervous epidermal sensory cells. These data provide the first identification of a rhodopsin-like protein in a phylogenetically old invertebrate and give a new insight into the Hydra photoreceptive response.


Assuntos
Hydra/química , Células Fotorreceptoras de Invertebrados/fisiologia , Pigmentos da Retina/análise , Animais , Comportamento Animal/fisiologia , Imunofluorescência , Imuno-Histoquímica , Rodopsina/química , Opsinas de Bastonetes/imunologia
9.
Tissue Cell ; 32(6): 451-6, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11197227

RESUMO

Deep-etching technique was used to investigate the organization of the pellicle complex of Euglena gracilis. The interpretation of the images was further supported by SEM and TEM investigations. Our results mainly validate data obtained by previous freeze-fracture studies on the E and P faces of the outer cortical membrane. At the level of the ridges, the outer E fracture face is highly organized in a regular striated pattern, whereas the P inner face shows a particulate structure. However, our images reveal that this particulate organization of the P face is not limited to the ridges, but it is displayed also by the grooves. Moreover, this face shows two distinct layers, a particulate layer facing the cytoplasm and a striated layer facing the E face; these layers represent different true fracture levels of the same P face.


Assuntos
Euglena gracilis/ultraestrutura , Animais , Citoplasma/ultraestrutura , Retículo Endoplasmático/ultraestrutura , Técnica de Congelamento e Réplica , Microscopia Eletrônica , Microscopia Eletrônica de Varredura , Microtúbulos/ultraestrutura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...