Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Plants (Basel) ; 12(1)2022 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-36616223

RESUMO

Flax is grown worldwide for seed and fiber production. Linseed varieties differ in their oil composition and are used in pharmaceutical, food, feed, and industrial production. The field of application primarily depends on the content of linolenic (LIN) and linoleic (LIO) fatty acids. Inactivating mutations in the FAD3A and FAD3B genes lead to a decrease in the LIN content and an increase in the LIO content. For the identification of the three most common low-LIN mutations in flax varieties (G-to-A in exon 1 of FAD3A substituting tryptophan with a stop codon, C-to-T in exon 5 of FAD3A leading to arginine to a stop codon substitution, and C-to-T in exon 2 of FAD3B resulting in histidine to tyrosine substitution), three approaches were proposed: (1) targeted deep sequencing, (2) high resolution melting (HRM) analysis, (3) cleaved amplified polymorphic sequences (CAPS) markers. They were tested on more than a thousand flax samples of various types and showed promising results. The proposed approaches can be used in marker-assisted selection to choose parent pairs for crosses, separate heterogeneous varieties into biotypes, and select genotypes with desired homozygous alleles of the FAD3A and FAD3B genes at the early stages of breeding for the effective development of varieties with a particular LIN and LIO content, as well as in basic studies of the molecular mechanisms of fatty acid synthesis in flax seeds to select genotypes adequate to the tasks.

2.
BMC Plant Biol ; 20(Suppl 1): 301, 2020 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-33050879

RESUMO

BACKGROUND: Flax (Linum usitatissimum L.) is grown for fiber and seed in many countries. Flax cultivars differ in the oil composition and, depending on the ratio of fatty acids, are used in pharmaceutical, food, or paint industries. It is known that genes of SAD (stearoyl-ACP desaturase) and FAD (fatty acid desaturase) families play a key role in the synthesis of fatty acids, and some alleles of these genes are associated with a certain composition of flax oil. However, data on genetic polymorphism of these genes are still insufficient. RESULTS: On the basis of the collection of the Institute for Flax (Torzhok, Russia), we formed a representative set of 84 cultivars and lines reflecting the diversity of fatty acid composition of flax oil. An approach for the determination of full-length sequences of SAD1, SAD2, FAD2A, FAD2B, FAD3A, and FAD3B genes using the Illumina platform was developed and deep sequencing of the 6 genes in 84 flax samples was performed on MiSeq. The obtained high coverage (about 400x on average) enabled accurate assessment of polymorphisms in SAD1, SAD2, FAD2A, FAD2B, FAD3A, and FAD3B genes and evaluation of cultivar/line heterogeneity. The highest level of genetic diversity was observed for FAD3A and FAD3B genes - 91 and 62 polymorphisms respectively. Correlation analysis revealed associations between particular variants in SAD and FAD genes and predominantly those fatty acids whose conversion they catalyze: SAD - stearic and oleic acids, FAD2 - oleic and linoleic acids, FAD3 - linoleic and linolenic acids. All except one low-linolenic flax cultivars/lines contained both the substitution of tryptophan to stop codon in the FAD3A gene and histidine to tyrosine substitution in the FAD3B gene, while samples with only one of these polymorphisms had medium content of linolenic acid and cultivars/lines without them were high-linolenic. CONCLUSIONS: Genetic polymorphism of SAD and FAD genes was evaluated in the collection of flax cultivars and lines with diverse oil composition, and associations between particular polymorphisms and the ratio of fatty acids were revealed. The achieved results are the basis for the development of marker-assisted selection and DNA-based certification of flax cultivars.


Assuntos
Ácidos Graxos Dessaturases/genética , Ácidos Graxos/metabolismo , Linho/genética , Variação Genética , Oxigenases de Função Mista/genética , Substituição de Aminoácidos , DNA de Plantas , Linho/enzimologia , Linho/metabolismo , Genes de Plantas , Heterogeneidade Genética , Oxigenases de Função Mista/metabolismo , Análise de Sequência de DNA , Ácido alfa-Linolênico/metabolismo
3.
Eur J Mass Spectrom (Chichester) ; 24(5): 363-374, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29665728

RESUMO

Yields of liquid products (bio-oil and residual organics in aqueous solution) of hydrothermal liquefaction (at 300℃ and 60 min) of own cultivated Arthrospira platensis using different solvents have been determined. Nonpolar hexane, moderately polar dichloromethane, and relatively more polar acetonitrile have been used. High-resolution mass spectrometry based on linear quadrupole ion trap and Fourier transform mass spectrometer (LTQ FT) has been used for liquid sample characterization. Concentration of bio-oil in a unit of solvent volume after solvent extraction took the following arrangement: acetonitrile > dichloromethane > hexane. Concentration of residual organics in a unit of aqueous solution after solvent extraction took the following arrangement: hexane >dichloromethane > acetonitrile. Yield of total organics was arranged as follows: hexane > dichloromethane > acetonitrile. Content of carbon in bio-oil was increased and the content of oxygen was decreased with the increasing of solvent polarity. From mass spectrometric analysis it was established that in the positive electrospray ionization (ESI) mode the compounds containing two nitrogen atoms dominate and the considerable portion of the compounds containing single nitrogen atom are also presented for both bio-oil and residual organics samples. In the negative ESI mode the compounds containing four oxygen atoms dominated except bio-oil obtained using hexane where the compounds containing two oxygen atoms dominated. Bio-oil fraction had highly saturated compounds with low double bond equivalent values while the compounds of the residual organics fraction had large double bond equivalent values.

4.
Mass Spectrom Rev ; 35(2): 219-58, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-24515872

RESUMO

Fourier transform ion cyclotron resonance (FT ICR) mass spectrometer offers highest resolving power and mass accuracy among all types of mass spectrometers. Its unique analytical characteristics made FT ICR important tool for proteomics, metabolomics, petroleomics, and investigation of complex mixtures. Signal acquisition in FT ICR MS takes long time (up to minutes). During this time ion-ion interaction considerably affects ion motion and result in decreasing of the resolving power. Understanding of those effects required complicated theory and supercomputer simulations but culminated in the invention of the ion trap with dynamic harmonization which demonstrated the highest resolving power ever achieved. In this review we summarize latest achievements in theory and simulation of FT ICR mass spectrometers.

5.
J Am Soc Mass Spectrom ; 25(5): 790-9, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24604470

RESUMO

Resolving power of about 12,000 000 at m/z 675 has been achieved on low field homogeneity 4.7 T magnet using a dynamically harmonized Fourier transform ion cyclotron resonance (FT ICR) cell. Mass spectra of the fine structure of the isotopic distribution of a peptide were obtained and strong discrimination of small intensity peaks was observed in case of resonance excitation of the ions of the whole isotopic cluster to the same cyclotron radius. The absence of some peaks from the mass spectra of the fine structure was explained basing on results of computer simulations showing strong ion cloud interactions, which cause the coalescence of peaks with m/z close to that of the highest magnitude peak. The way to prevent peak discrimination is to excite ion clouds of different m/z to different cyclotron radii, which was demonstrated and investigated both experimentally and by computer simulations.


Assuntos
Modelos Moleculares , Oligopeptídeos/química , Angiotensina I/química , Ciclotrons/instrumentação , Técnicas Eletroquímicas/instrumentação , Análise de Fourier , Simulação de Dinâmica Molecular , Fragmentos de Peptídeos/química , Conformação Proteica , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Substância P/química
6.
J Am Soc Mass Spectrom ; 23(12): 2198-207, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22993044

RESUMO

The recently introduced ion trap for FT-ICR mass spectrometers with dynamic harmonization showed the highest resolving power ever achieved both for ions with moderate masses 500-1000 Da (peptides) as well as ions with very high masses of up to 200 kDa (proteins). Such results were obtained for superconducting magnets of very high homogeneity of the magnetic field. For magnets with lower homogeneity, the time of transient duration would be smaller. In superconducting magnets used in FT-ICR mass spectrometry the inhomogeneity of the magnetic field in its axial direction prevails over the inhomogeneity in other directions and should be considered as the main factor influencing the synchronic motion of the ion cloud. The inhomogeneity leads to a dependence of the cyclotron frequency from the amplitude of axial oscillation in the potential well of the ion trap. As a consequence, ions in an ion cloud become dephased, which leads to signal attenuation and decrease in the resolving power. Ion cyclotron frequency is also affected by the radial component of the electric field. Hence, by appropriately adjusting the electric field one can compensate the inhomogeneity of the magnetic field and align the cyclotron frequency in the whole range of amplitudes of z-oscillations. A method of magnetic field inhomogeneity compensation in a dynamically harmonized FT-ICR cell is presented, based on adding of extra electrodes into the cell shaped in such a way that the averaged electric field created by these electrodes produces a counter force to the forces caused by the inhomogeneous magnetic field.


Assuntos
Campos Eletromagnéticos , Espectrometria de Massas/instrumentação , Espectrometria de Massas/métodos , Modelos Teóricos , Simulação por Computador , Análise de Fourier , Imãs , Peso Molecular , Peptídeos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...