Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ESC Heart Fail ; 11(1): 293-298, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37985002

RESUMO

AIMS: The relationship between accelerometry data and changes in Kansas City Cardiomyopathy Questionnaire-Physical Limitation Score (KCCQ-PLS) or 6 min walk test (6MWT) is not well understood. METHODS AND RESULTS: VITALITY-HFpEF accelerometry substudy (n = 69) data were assessed at baseline and 24 weeks. Ordinal logistic regression models were used to assess the association between accelerometry activity and deterioration, improved, or unchanged KCCQ-PLS (≥8.33 and ≤ -4.17 points) and 6MWT (≥32 vs. ≤ -32 m). KCCQ-PLS score deteriorated in 16 patients, improved in 34, and was unchanged in 19. 6MWT deteriorated in 8 patients, improved in 21, and was unchanged in 19. Mean accelerometer wear was 21.4 (±2.1) h/day. Changes in hours active from baseline to 24 weeks were not significantly different among patients who exhibited deterioration, improvement, or no change in KCCQ-PLS [odds ratio (OR) 0.91, 95% confidence interval (CI) 0.71-1.18; P = 0.48] or 6MWT (OR 1.21, 95% CI 0.91-1.60; P = 0.18). Similar lack of association was observed for other accelerometry metrics and change in KCCQ and 6MWT. These findings were unaffected when KCCQ and 6MWT were examined as continuous variables. CONCLUSIONS: Accelerometer-based activity measures did not correlate with subjective or objective standard measures of health status and functional capacity in heart failure with preserved ejection fraction. Further investigation of their relationships to clinical outcomes is required.


Assuntos
Insuficiência Cardíaca , Humanos , Acelerometria , Nível de Saúde , Qualidade de Vida , Volume Sistólico
2.
Digit Biomark ; 7(1): 74-91, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37588480

RESUMO

Background: Assessment of reliability is one of the key components of the validation process designed to demonstrate that a novel clinical measure assessed by a digital health technology tool is fit-for-purpose in clinical research, care, and decision-making. Reliability assessment contributes to characterization of the signal-to-noise ratio and measurement error and is the first indicator of potential usefulness of the proposed clinical measure. Summary: Methodologies for reliability analyses are scattered across literature on validation of PROs, wet biomarkers, etc., yet are equally useful for digital clinical measures. We review a general modeling framework and statistical metrics typically used for reliability assessments as part of the clinical validation. We also present methods for the assessment of agreement and measurement error, alongside modified approaches for categorical measures. We illustrate the discussed techniques using physical activity data from a wearable device with an accelerometer sensor collected in clinical trial participants. Key Messages: This paper provides statisticians and data scientists, involved in development and validation of novel digital clinical measures, an overview of the statistical methodologies and analytical tools for reliability assessment.

3.
ESC Heart Fail ; 9(6): 3791-3803, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35880474

RESUMO

AIMS: Treatment response to vericiguat, based on baseline N-terminal pro-brain natriuretic peptide (NT-proBNP) subgroups specified in the protocol, was evaluated in the heart failure (HF) VICTORIA trial population by post hoc analysis of combined lower three quartiles [Q1-Q3] vs. the upper quartile [Q4]. METHODS AND RESULTS: VICTORIA participants with available baseline NT-proBNP levels (n = 4805; 95.1% of total) were included. Compared with patients in Q1-Q3 (NT-proBNP: Q1, ≤1556 pg/mL; Q2, >1556-2816 pg/mL; and Q3, >2816-5314 pg/mL), patients in Q4 (NT-proBNP: >5314 pg/mL) were older (69.2 ± 12.0 vs. 66.6 ± 12.1 years), had lower mean ejection fraction (27.2 ± 8.3% vs. 29.5 ± 8.2%; P < 0.0001), and were more likely to be in New York Heart Association (NYHA) Class III (51.8 vs. 35.6%) or IV (2.4 vs. 1.0%). Compared with Q1-Q3, patients in Q4 had higher mean Meta-Analysis Global Group in Chronic Heart Failure risk score (27.3 ± 6.6 vs. 23.5 ± 6.4; P < 0.0001), had lower mean estimated glomerular filtration rate (eGFR; 51.5 ± 25.5 vs. 65.0 ± 26.8 mL/min/1.73 m2 ; P < 0.0001) and haemoglobin (12.8 ± 2.0 vs. 13.6 ± 1.9 g/dL; P < 0.0001), and more had atrial fibrillation (48.7% vs. 43.1%; P = 0.0007) and were randomized while hospitalized for HF (14.8 vs. 9.9%; P < 0.0001). Target dose was achieved in 72.3 and 63.7% of patients in Q1-Q3 and Q4, respectively (P < 0.0001). Primary outcome (composite of time to cardiovascular death or first HF hospitalization) rates were 24.5 and 31.7 per 100 patient-years for vericiguat and placebo in Q1-Q3 [hazard ratio (HR) 0.78; 95% confidence interval (CI) 0.69-0.88, P < 0.001] and 73.6 and 63.6 in Q4 (HR 1.15; 95% CI 0.99-1.34, P = 0.070). Serious adverse events were more frequent in NT-proBNP Q4 (total population) compared with Q1-Q3 (38.3 vs. 32.3%; P = 0.0001), driven mainly by the placebo group. Adverse events leading to death were more frequent in Q4 than Q1-Q3 (5.8 vs. 2.4%; P < 0.0001). CONCLUSIONS: Plasma NT-proBNP may help identify patients with worsening HF with reduced ejection fraction, in whom the beneficial effects of vericiguat may be highest. Patients with highest NT-proBNP values are probably too far advanced, suffering more co-morbidities, or still clinically unstable after decompensation to derive benefit from vericiguat.


Assuntos
Insuficiência Cardíaca , Humanos , Volume Sistólico/fisiologia , Insuficiência Cardíaca/tratamento farmacológico , Peptídeo Natriurético Encefálico
4.
Eur J Heart Fail ; 24(5): 843-850, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35274420

RESUMO

AIMS: Clinically important thresholds in patient-reported outcomes measures like the Kansas City Cardiomyopathy Questionnaire (KCCQ) have not been defined for patients with heart failure and preserved ejection fraction (HFpEF). The aim of this study was to estimate meaningful thresholds for improvement or worsening in the KCCQ physical limitation score (PLS) in patients with HFpEF. METHODS AND RESULTS: In this pre-specified analysis from VITALITY-HFpEF, anchor- and distribution-based approaches were used to estimate thresholds for improvement or worsening in the KCCQ-PLS using Patient Global Impression of Change (PGIC) as an anchor. The KCCQ-PLS contains six elements, with each increment in response resulting in a change of 4.17 points when converted to a 0-100 scale. The mean change in KCCQ-PLS from baseline to week 12 was calculated for each PGIC group to estimate a meaningful within-patient change. Of 789 patients enrolled, 698 had complete KCCQ-PLS and PGIC data at week 12. The mean (± standard deviation) changes in KCCQ-PLS corresponding to PGIC changes of 'a little better', 'better', and 'much better' were 5.7 ± 18.6, 11.6 ± 19.3, and 18.4 ± 25.3 points, respectively. The scores of patients who responded 'a little better' (n = 177) overlapped substantially with those who reported 'no change' (n = 193; mean change 2.8 ± 18.9). The mean change in KCCQ-PLS for patients responding 'a little worse' (n = 32) was -2.6 ± 18.0 points. The threshold for meaningful within-patient change in KCCQ-PLS based on distribution-based analyses was 12.3 points. Using area under the curve (AUC) analyses of KCCQ-PLS, the sensitivity and specificity of a 4.17-point change were 0.61 and 0.57, for an 8.33-point change they were 0.49 and 0.64, and for a 12.5-point change they were 0.44 and 0.72 for being at least a little better on the PGIC (AUC = 0.54). CONCLUSION: In the VITALITY-HFpEF trial, a change in KCCQ-PLS of ≥8.33 points (corresponding to an improvement in ≥2 response categories of KCCQ-PLS) may represent the minimal clinically important difference for improvement and a change of ≤ -4.17 points (corresponding to a worsening in ≥1 response category of KCCQ-PLS) may suggest deterioration in patients with HFpEF.


Assuntos
Insuficiência Cardíaca , Humanos , Diferença Mínima Clinicamente Importante , Medidas de Resultados Relatados pelo Paciente , Qualidade de Vida , Volume Sistólico/fisiologia
5.
JAMA ; 324(15): 1512-1521, 2020 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-33079152

RESUMO

Importance: Patients with heart failure and preserved ejection fraction (HFpEF) are at high risk of mortality, hospitalizations, and reduced functional capacity and quality of life. Objective: To assess the efficacy of the oral soluble guanylate cyclase stimulator vericiguat on the physical limitation score (PLS) of the Kansas City Cardiomyopathy Questionnaire (KCCQ). Design, Setting, and Participants: Phase 2b randomized, double-blind, placebo-controlled, multicenter trial of 789 patients with chronic HFpEF and left ventricular ejection fraction 45% or higher with New York Heart Association class II-III symptoms, within 6 months of a recent decompensation (HF hospitalization or intravenous diuretics for HF without hospitalization), and with elevated natriuretic peptides, enrolled at 167 sites in 21 countries from June 15, 2018, through March 27, 2019; follow-up was completed on November 4, 2019. Interventions: Patients were randomized to receive vericiguat, up-titrated to 15-mg (n = 264) or 10-mg (n = 263) daily oral dosages, compared with placebo (n = 262) and randomized 1:1:1. Main Outcomes and Measures: The primary outcome was change in the KCCQ PLS (range, 0-100; higher values indicate better functioning) after 24 weeks of treatment. The secondary outcome was 6-minute walking distance from baseline to 24 weeks. Results: Among 789 randomized patients, the mean age was 72.7 (SD, 9.4) years; 385 (49%) were female; mean EF was 56%; and median N-terminal pro-brain natriuretic peptide level was 1403 pg/mL; 761 (96.5%) completed the trial. The baseline and 24-week KCCQ PLS means for the 15-mg/d vericiguat, 10-mg/d vericiguat, and placebo groups were 60.0 and 68.3, 57.3 and 69.0, and 59.0 and 67.1, respectively, and the least-squares mean changes were 5.5, 6.4, and 6.9, respectively. The least-squares mean difference in scores between the 15-mg/d vericiguat and placebo groups was -1.5 (95% CI, -5.5 to 2.5; P = .47) and between the 10-mg/d vericiguat and placebo groups was -0.5 (95% CI, -4.6 to 3.5; P = .80). The baseline and 24-week 6-minute walking distance mean scores in the 15-mg/d vericiguat, 10-mg/d vericiguat, and placebo groups were 295.0 m and 311.8m , 292.1 m and 318.3 m, and 295.8 m and 311.4 m, and the least-squares mean changes were 5.0 m, 8.7 m, and 10.5 m, respectively. The least-squares mean difference between the 15-mg/d vericiguat and placebo groups was -5.5 m (95% CI, -19.7 m to 8.8 m; P = .45) and between the 10-mg/d vericiguat and placebo groups was -1.8 m (95% CI, -16.2 m to 12.6 m; P = .81), respectively. The proportions of patients who experienced symptomatic hypotension were 6.4% in the 15-mg/d vericiguat group, 4.2% in the 10-mg/d vericiguat group, and 3.4% in the placebo group; those with syncope were 1.5%, 0.8%, and 0.4%, respectively. Conclusions and Relevance: Among patients with HFpEF and recent decompensation, 24-week treatment with vericiguat at either 15-mg/d or 10-mg/d dosages compared with placebo did not improve the physical limitation score of the KCCQ. Trial Registration: ClinicalTrials.gov Identifier: NCT03547583.


Assuntos
Tolerância ao Exercício/efeitos dos fármacos , Insuficiência Cardíaca/tratamento farmacológico , Compostos Heterocíclicos com 2 Anéis/uso terapêutico , Pirimidinas/uso terapêutico , Qualidade de Vida , Administração Oral , Idoso , Método Duplo-Cego , Feminino , Guanilato Ciclase/metabolismo , Insuficiência Cardíaca/fisiopatologia , Compostos Heterocíclicos com 2 Anéis/administração & dosagem , Compostos Heterocíclicos com 2 Anéis/efeitos adversos , Hospitalização , Humanos , Análise dos Mínimos Quadrados , Masculino , Pessoa de Meia-Idade , Pirimidinas/administração & dosagem , Pirimidinas/efeitos adversos , Volume Sistólico , Falha de Tratamento , Teste de Caminhada
6.
Iperception ; 7(1): 2041669516631698, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27482372

RESUMO

The present experiment was designed to examine the roles of painted linear perspective cues, and the convexity bias that are known to influence human observers' perception of three-dimensional (3D) objects and scenes. Reverse-perspective stimuli were used to elicit a depth-inversion illusion, in which far points on the stimulus appear to be closer than near points and vice versa, with a 2 (Type of stimulus) × 2 (Fixation mark position) design. To study perspective, two types of stimuli were used: a version with painted linear perspective cues and a version with blank (unpainted) surfaces. To examine the role of convexity, two locations were used for the fixation mark: either in a locally convex or a locally concave part of each stimulus (painted and unpainted versions). Results indicated that the reverse-perspective illusion was stronger when the stimulus contained strong perspective cues and when observers fixated a locally concave region within the scene.

7.
Perception ; 43(5): 381-94, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25109006

RESUMO

Upright hollow human faces produce among the strongest depth-inversion illusions (DIIs), but why? We considered the role of depth undulations by comparing four types of hollow objects: an ellipsoid, a human mask, and two symmetric 'Martian'masks, which wavered in depth like the human mask but which lacked face-like features. Illusion strength was quantified either as the critical viewing distance at which the 3-D percept switched between convex and concave (experiment 1) or as the proportion of time ('predominance') that observers experienced DII from a fixed intermediate viewing distance (experiment 2). Critical distances were smallest--and hence the illusion was strongest--for the upright human mask; the remaining objects produced undifferentiated critical distance values. The predominance results were more fine-grained: illusions were experienced most often for the upright human mask, least often for the hollow ellipsoid, and to an intermediate extent for the Martian and upside-down human masks. These results suggest: (1) an upside-down human mask and a surface with nonface features undulating in depth are equivalent for the purposes of generating DIIs; (2) depth undulations contribute to DII; and (3) such undulations are most effective when structured into an upright human face.


Assuntos
Percepção de Profundidade , Face , Ilusões Ópticas , Orientação , Reconhecimento Visual de Modelos , Adolescente , Discriminação Psicológica , Percepção de Distância , Feminino , Humanos , Masculino , Psicofísica , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...