Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med. oral patol. oral cir. bucal (Internet) ; 25(2): e224-e232, mar. 2020. ilus, tab
Artigo em Inglês | IBECS | ID: ibc-196252

RESUMO

BACKGROUND: The aim of this in vitro study was to evaluate the effect of diode lasers at different wavelengths and power settings in handmade incisions in periodontal pockets and in oral mucosa of porcine tissue considering thermal damage, necrosis and the affected area of the soft tissue. MATERIAL AND METHODS: Combining the following laser wavelengths, 445 nm, 532 nm (KTP), 810 nm, 980 nm, 1064 nm and 1470 nm, and a power range from 0.5W to 2.0W in a continuous wave mode (CW), we made handmade incisions in porcine periodontal pockets and oral mucosa. After histological processing, we measured the area of lost tissue, the area of thermal damage and the area of necrosis. Then, we performed ANOVA to evaluate the difference between groups and two-way ANOVA to identify the influence of the laser-type variables and the power on the results. RESULTS: We applied an ANOVA test to evaluate the results, where statistical analysis showed clear differences between the 1470nm and 810nm laser groups that refer to thermal damage and necrosis in the periodontal pocket surface. Regarding the oral mucosa surface, the 1064 nm laser showed differences in the analysis of lost tissue. According to the applied power, all the variables we studied (lost tissue area, area of thermal damage and necrosis) showed higher values when using a power of 2.0W instead of 0.5W. CONCLUSIONS: According to our results, the 810nm diode laser for oral soft-tissue biopsy using power ranges between 0.5W and 2W would be the best choice to avoid thermal damage in peri-incisional margins


No disponible


Assuntos
Animais , Lasers Semicondutores , Bolsa Periodontal/patologia , Mucosa Bucal/efeitos da radiação , Suínos , Doses de Radiação , Necrose , Lesões por Radiação/patologia , Mucosa Bucal/patologia , Biópsia , Valores de Referência , Reprodutibilidade dos Testes
2.
Med. oral patol. oral cir. bucal (Internet) ; 23(1): e78-e85, ene. 2018. ilus, tab
Artigo em Inglês | IBECS | ID: ibc-170308

RESUMO

Background: The aim of this study is to evaluate the resection of hyperplastic lesions on the buccal mucosa comparing the 532nm laser (KTP), versus diode 980nm laser, considering pain, scarring, inflammation and drug consumption that occurred postoperatively with each lasers. Material and Methods: A prospective study of consecutive series of 20 patients in two groups that presents hyperplastic lesions on the buccal mucosa. The choice of the KTP laser or diode 980nm laser for the surgery was made randomly. The power used was 1.5W in both groups in a continuous wave mode with a 320 μm optical fiber. Parameters of pain, scarring, inflammation and consumption of drugs were recorded by a Numerical Rating Scale and evaluated postoperatively. These recordings were made the day of the surgery, 24 hours after, 14 and 28 days after. Results: Pain and inflammation was light - moderate. The consumption of paracetamol was somewhat higher in the diode 980nm laser versus the KTP laser after 24 hours, although data was not statistically significant; significant differences were found after 28 days in regards to pain (p = 0.023) and inflammation (p = 0.023), but always in the absence parameter so we find no pain in both lasers. Scarring in the two types of laser showed no differences along the visits, with not detected scar retractable. Conclusions: Although there is a slight histological difference regarding the KTP laser in the oral soft tissues for clinical use, both wavelengths are very suitable for excision of oral fibroma (AU)


No disponible


Assuntos
Humanos , Hiperplasia/diagnóstico , Hiperplasia/terapia , Neoplasias Bucais/terapia , Mucosa Bucal/patologia , Mucosa Bucal/efeitos da radiação , Terapia a Laser/métodos , Estudos Prospectivos , Acetaminofen/uso terapêutico , Manejo da Dor
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA