Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bioanalysis ; 4(2): 167-75, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22250799

RESUMO

BACKGROUND: Two-step derivatization procedures were developed for the enhancement of the positive ESI in LC-MS detection of anabolic androgenic steroids, a class of prohibited substances with limited ionization efficiency in atmospheric pressure interfaces. The developed procedures are based on the esterification of hydroxyl groups of anabolic steroids with picolinic acid, followed by conversion of carbonyl groups to Schiff bases by either Girard's reagent T or 2-hydrazino pyridin. RESULTS: Ionization efficiency for the model derivatized compounds 19-norandrosterone (nandrolone main metabolite) and methasterone was higher by almost two orders of magnitude compared with the respective efficiency of the underivatized compounds. CONCLUSION: The obtained derivatives provided a significant improvement in the ESI sensitivity, compared with those of underivatized molecules in positive LC-ESI-ion trap-MS full-scan mode.


Assuntos
Anabolizantes/urina , Cromatografia Líquida/métodos , Dopagem Esportivo/prevenção & controle , Espectrometria de Massas por Ionização por Electrospray/métodos , Detecção do Abuso de Substâncias/métodos , Anabolizantes/química , Feminino , Humanos , Masculino
2.
Rapid Commun Mass Spectrom ; 24(11): 1595-609, 2010 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-20486255

RESUMO

Unification of the screening protocols for a wide range of doping agents has become an important issue for doping control laboratories. This study presents the development and validation of a generic liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) screening method of 241 small molecule analytes from various categories of prohibited substances (stimulants, narcotics, diuretics, beta(2)-agonists, beta-blockers, hormone antagonists and modulators, glucocorticosteroids and anabolic agents). It is based on a single-step liquid-liquid extraction of hydrolyzed urine and the use of a rapid-resolution liquid chromatography/high-resolution time-of-flight mass spectrometric system acquiring continuous full scan data. Electrospray ionization in the positive mode was used. Validation parameters consisted of identification capability, limit of detection, specificity, ion suppression, extraction recovery, repeatability and mass accuracy. Detection criteria were established on the basis of retention time reproducibility and mass accuracy. The suitability of the methodology for doping control was demonstrated with positive urine samples. The preventive role of the method was proved by the case where full scan acquisition with accurate mass measurement allowed the retrospective reprocessing of acquired data from past doping control samples for the detection of a designer drug, the stimulant 4-methyl-2-hexanamine, which resulted in re-reporting a number of stored samples as positives for this particular substance, when, initially, they had been reported as negatives.


Assuntos
Anabolizantes/urina , Cromatografia Líquida/métodos , Dopagem Esportivo/prevenção & controle , Espectrometria de Massas/métodos , Detecção do Abuso de Substâncias/métodos , Humanos , Limite de Detecção
3.
Anal Bioanal Chem ; 395(5): 1403-10, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19756547

RESUMO

In equine sport, salicylic acid is prohibited with a threshold level of 750 microg mL(-1) in urine; hence, doping control laboratories have to establish quantitative and qualitative methods for its determination. A simple and rapid liquid chromatographic/mass spectrometric method was developed and validated for the quantification and identification of salicylic acid. Urine samples after 900-fold dilution and addition of the internal standard (4-methylsalicylic acid) were directly injected to the liquid chromatography/quadrupole time-of-flight mass spectrometry system. Electrospray ionization in negative mode with full scan acquisition mode and product ion scan mode were chosen for the quantification and identification of salicylic acid, respectively. Run time was 2.0 min. The tested linear range was 2.5-50 microg mL(-1) (after 100-fold sample dilution). The relative standard deviations of intra- and inter-assay analysis of salicylic acid in horse urine were lower than 2.5% and 2.8%, respectively. Overall accuracy (relative percentage error) was less than 3.3%. Method was applied to two real samples found to be positive for salicylic acid, demonstrating simplicity, accuracy, and selectivity.


Assuntos
Cromatografia Líquida/métodos , Dopagem Esportivo/métodos , Cavalos/urina , Espectrometria de Massas/métodos , Ácido Salicílico/urina , Animais , Calibragem , Estrutura Molecular , Ácido Salicílico/química , Fatores de Tempo
4.
Rapid Commun Mass Spectrom ; 23(7): 1020-8, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19263423

RESUMO

In equine sport, theobromine is prohibited with a threshold level of 2 microg mL(-1) in urine, hence doping control laboratories have to establish quantitative and qualitative methods for its determination. Two simple liquid chromatography/mass spectrometry (LC/MS) methods for the identification and quantification of theobromine were developed and validated using the same sample preparation procedure but different mass spectrometric systems: ion trap mass spectrometry (ITMS) and time-of-flight mass spectrometry (TOFMS). Particle-free diluted urine samples were directly injected into the LC/MS systems, avoiding the time-consuming extraction step. 3-Propylxanthine was used as the internal standard. The tested linear range was 0.75-15 microg mL(-1). Matrix effects were evaluated analyzing calibration curves in water and different fortified horse urine samples. A great variation in the signal of theobromine and the internal standard was observed in different matrices. To overcome matrix effects, a standard additions calibration method was applied. The relative standard deviations of intra- and inter-day analysis were lower than 8.6 and 7.2%, respectively, for the LC/ITMS method and lower than 5.7 and 5.8%, respectively, for the LC/TOFMS method. The bias was less than 8.7% for both methods. The methods were applied to two case samples, demonstrating simplicity, accuracy and selectivity.


Assuntos
Dopagem Esportivo , Espectrometria de Massas por Ionização por Electrospray/métodos , Detecção do Abuso de Substâncias/métodos , Teobromina/urina , Urinálise/métodos , Vasodilatadores/urina , Animais , Cromatografia Líquida de Alta Pressão , Cavalos , Reprodutibilidade dos Testes
5.
Drug Test Anal ; 1(8): 365-71, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20355216

RESUMO

Levodopa and dopamine have been abused as performance-altering substances in horse racing. Urinary 3-methoxytyramine is used as an indicator of dopaminergic manipulation resulting from dopamine or levodopa administration and is prohibited with a urinary threshold of 4 microg mL(-1) (free and conjugated). A simple liquid chromatographic (LC)/mass spectrometric (MS) (LCMS) method was developed and validated for the quantification and identification of 3-methoxytyramine in equine urine. Sample preparation involved enzymatic hydrolysis and protein precipitation. Hydrophilic interaction liquid chromatography (HILIC) was selected as a separation technique that allows effective retention of polar substances like 3-methoxytyramine and efficient separation from matrix compounds. Electrospray ionization (ESI) in positive mode with product ion scan mode was chosen for the detection of the analytes. Quantification of 3-methoxytyramine was performed with fragmentation at low collision energy, resulting in one product ion, while a second run at high collision energy was performed for confirmation (at least three abundant ions). Studies on matrix effects showed ion suppression depending on the horse urine used. To overcome the variability of the results originating from the matrix effects, isotopic labelled internal standard was used and linear regression calibration methodology was applied for the quantitative determination of the analyte. The tested linear range was 1-20 microg mL(-1). The relative standard deviations of intra- and inter- assay analysis of 3-methoxytyramine in horse urine were lower than 4.2% and 3.2%, respectively. Overall accuracy (relative percentage error) was less than 6.2%. The method was applied to case samples, demonstrating simplicity, accuracy and selectivity.


Assuntos
Dopamina/análogos & derivados , Espectrometria de Massas por Ionização por Electrospray/métodos , Detecção do Abuso de Substâncias/métodos , Urinálise/métodos , Animais , Calibragem , Cromatografia Líquida/métodos , Dopamina/urina , Feminino , Cavalos , Interações Hidrofóbicas e Hidrofílicas , Masculino
6.
J Mass Spectrom ; 43(9): 1255-64, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18407581

RESUMO

Two simple and rapid LC/MS methods with direct injection analysis were developed and validated for the quantification and identification of hydrocortisone in equine urine using the same sample preparation but different mass spectrometric systems: ion trap mass spectrometry (IT-MS) and time-of-flight mass spectrometry (TOF-MS). The main advantage of the proposed methodology is the minimal sample preparation procedure, as particle-free diluted urine samples were directly injected into both LC/MS systems. Desonide was used as internal standard (IS). The linear range was 0.25-2.5 microg ml(-1) for both methods. Matrix effects were evaluated by preparing and analyzing calibration curves in water solutions and different horse urine samples. A great variation of the signal both for hydrocortisone and the internal standard was observed in different matrices. To overcome matrix effects, the unavailability of blank matrix and the excessive cost of the isotopically labeled internal standard, standard additions calibration method was applied. This work is an exploration of the performance of the standard additions approach in a method where neither nonisotopic internal standards nor extensive sample preparation is utilized and no blank matrix is available. The relative standard deviations of intra and interday analysis of hydrocortisone in horse urine were lower than 10.2 and 5.4%, respectively, for the LC/IT-MS method and lower than 8.4 and 4.4%, respectively, for the LC/TOF-MS method. Accuracy (bias percentage) was less than 9.7% for both methods.


Assuntos
Anti-Inflamatórios/urina , Dopagem Esportivo/métodos , Hidrocortisona/urina , Espectrometria de Massas por Ionização por Electrospray/métodos , Detecção do Abuso de Substâncias/métodos , Animais , Cromatografia Líquida de Alta Pressão , Cavalos , Reprodutibilidade dos Testes
7.
Anal Chim Acta ; 573-574: 242-9, 2006 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-17723530

RESUMO

A new liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) (n) ion trap method for the determination of corticosteroids in urine has been developed and validated. Some anabolic agents, such as epitrenbolone, trenbolone, 2-hydroxymethylformebolone, tetrahydrogestrinone, gestrinone and formoterol were included in the LC-ESI-MS method. Matrix interference, specificity, identification capability, carry over and robustness were estimated as validation parameters. Recoveries ranged from 74 to 113% at the minimum required performance limit (MRPL), which is 30 ng mL(-1) for corticosteroids and 10 ng mL(-1) for anabolic agents. Methods for the confirmation and quantification of norpseudoephedrine, ephedrine, methylephedrine, salbutamol, morphine and morphine glucuronide were also developed and validated and in order to minimize analysis time, direct urine injection was used. These methods proved to be specific, accurate and precise across a calibration range for each substance since matrix interference, specificity, carry over, within and between run precision, limit of detection, limit of quantification, intermediate precision and uncertainty were estimated.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...