Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diabetes Obes Metab ; 25(11): 3212-3222, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37551542

RESUMO

AIMS: To reassess the 6-month efficacy and to assess the 12-month sustained efficacy of the MiniMed™ 780G advanced hybrid closed-loop automated insulin delivery (AID) system compared to multiple daily injections plus intermittently scanned glucose monitoring (MDI+isCGM) in people with type 1 diabetes not meeting glucose targets. METHODS: The ADAPT study was a prospective, multicentre, open-label, randomized control trial in people with type 1 diabetes, with a glycated haemoglobin (HbA1c) concentration of at least 8.0% (64 mmol/mol), on MDI+isCGM therapy. After a 6-month study phase, participants randomized at baseline to MDI+isCGM switched to AID (SWITCH) while the others continued AID therapy (SUSTAIN) for an additional 6 months. The primary endpoint of this continuation phase was the within-group change in mean HbA1c between 6 and 12 months, with superiority in the SWITCH group and noninferiority in the SUSTAIN group (ClinicalTrials.gov: NCT04235504). RESULTS: A total of 39 SWITCH and 36 SUSTAIN participants entered the continuation phase. In the SWITCH group, HbA1c was significantly decreased by -1.4% (95% confidence interval [CI] -1.7% to -1.1%; P < 0.001) from a mean ± SD of 8.9% ± 0.8% (73.9 ± 8.6 mmol/mol) at 6 months to 7.5% ± 0.6% (58.5 ± 6.9 mmol/mol) at 12 months. Mean HbA1c increased by 0.1% (95% CI -0.05% to +0.25%), from 7.3% ± 0.6% (56.5 ± 6.7 mmol/mol) to 7.4% ± 0.8% (57.7 ± 9.1 mmol/mol) in the SUSTAIN group, meeting noninferiority criteria. Three severe hypoglycaemia events occurred in two SWITCH participants during the continuation phase. CONCLUSION: ADAPT study phase glycaemic improvements were reproduced and sustained in the continuation phase, supporting the early adoption of AID therapy in people with type 1 diabetes not meeting glucose targets on MDI therapy.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Adulto , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Hemoglobinas Glicadas , Estudos Prospectivos , Automonitorização da Glicemia , Reprodutibilidade dos Testes , Glicemia , Sistemas de Infusão de Insulina
2.
J Diabetes Sci Technol ; : 19322968231161320, 2023 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-36949671

RESUMO

BACKGROUND: This analysis reports the findings from a predefined exploratory cohort (cohort B) from the ADAPT (ADvanced Hybrid Closed Loop Study in Adult Population with Type 1 Diabetes) study. Adults with type 1 diabetes (T1D) with suboptimal glucose control were randomly allocated to an advanced hybrid closed-loop (AHCL) system or multiple daily injections of insulin (MDI) plus real-time continuous glucose monitoring (RT-CGM). METHODS: In this prospective, multicenter, exploratory, open-label, randomized controlled trial, 13 participants using MDI + RT-CGM and with HbA1c ≥8.0% were randomized to switch to AHCL (n = 8) or continue with MDI + RT-CGM (n = 5) for six months. Prespecified endpoints included the between-group difference in mean change from baseline in HbA1c, CGM-derived measures of glycemic control, and safety. RESULTS: The mean HbA1c level decreased by 1.70 percentage points in the AHCL group versus a 0.60 percentage point decrease in the MDI + RT-CGM group, with a model-based treatment effect of -1.08 percentage points (95% confidence interval [CI] = -2.17 to 0.00 percentage points; P = .0508) in favor of AHCL. The percentage of time spent with sensor glucose levels between 70 and 180 mg/dL in the study phase was 73.6% in the AHCL group and 46.4% in the MDI + RT-CGM group; model-based between-group difference of 28.8 percentage points (95% CI = 12.3 to 45.3 percentage points; P = .0035). No diabetic ketoacidosis or severe hypoglycemia occurred in either group. CONCLUSIONS: In people with T1D with HbA1c ≥8.0%, the use of AHCL resulted in improved glycemic control relative to MDI + RT-CGM. The scale of improvement suggests that AHCL should be considered as an option for people not achieving good glycemic control on MDI + RT-CGM.

3.
Lancet Diabetes Endocrinol ; 10(10): 720-731, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36058207

RESUMO

BACKGROUND: Adults with type 1 diabetes who are treated with multiple daily injections of insulin plus intermittently scanned continuous glucose monitoring (isCGM) can have suboptimal glucose control. We aimed to assess the efficacy of an advanced hybrid closed loop (AHCL) system compared with such therapy in this population. METHODS: The Advanced Hybrid Closed Loop Study in Adult Population with Type 1 Diabetes (ADAPT) trial is a prospective, multicentre, open-label, randomised controlled trial that involved 14 centres in three European countries (France, Germany, and the UK). We enrolled patients who were at least 18 years of age, had a type 1 diabetes duration of at least 2 years, HbA1c of at least 8% (64 mmol/mol), and were using multiple daily injections of insulin plus isCGM (cohort A) or real time continuous glucose monitoring (cohort B) for at least 3 months. Here, only results for cohort A are reported. Participants were randomly allocated 1:1 to AHCL therapy or continuation of multiple daily injections of insulin plus continuous glucose monitoring for 6 months with an investigator-blinded block randomisation procedure. Participants and treating clinicians could not be masked to the arm assignment. The primary endpoint was the between-group difference in mean HbA1c change from baseline to 6 months in the intention-to-treat population using AHCL therapy and those using multiple daily injections of insulin plus isCGM. The primary endpoint was analysed using a repeated measures random-effects model with the study arm and period as factors. Safety endpoints included the number of device deficiencies, severe hypoglycaemic events, diabetic ketoacidosis, and serious adverse events. This study is registered with ClinicalTrials.gov, NCT04235504. FINDINGS: Between July 13, 2020, and March 12, 2021, 105 people were screened and 82 randomly assigned to treatment (41 in each arm). At 6 months, mean HbA1c had decreased by 1·54% (SD 0·73), from 9·00% to 7·32% in the AHCL group and 0·20% (0·80) in the multiple daily injections of insulin plus isCGM from 9·07% to 8·91% (model-based difference -1·42%, 95% CI -1·74 to -1·10; p<0·0001). No diabetic ketoacidosis, severe hypoglycaemia, or serious adverse events related to study devices occurred in either group; two severe hypoglycaemic events occurred in the run-in phase. 15 device-related non-serious adverse events occurred in the AHCL group, compared with three in the multiple daily injections of insulin plus isCGM group. Two serious adverse events occurred (one in each group), these were breast cancer (in one patient in the AHCL group) and intravitreous haemorrhage (in one patient in the multiple daily injections of insulin plus isCGM group). INTERPRETATION: In people with type 1 diabetes using multiple daily injections of insulin plus isCGM and with HbA1c of at least 8%, the use of AHCL confers benefits in terms of glycaemic control beyond those that can be achieved with multiple daily injections of insulin plus isCGM. These data support wider access to AHCL in people with type 1 diabetes not at target glucose levels. FUNDING: Medtronic International Trading Sàrl.


Assuntos
Diabetes Mellitus Tipo 1 , Cetoacidose Diabética , Adulto , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/induzido quimicamente , Diabetes Mellitus Tipo 1/tratamento farmacológico , Cetoacidose Diabética/induzido quimicamente , Hemoglobinas Glicadas , Humanos , Hipoglicemiantes , Insulina/uso terapêutico , Estudos Prospectivos , Resultado do Tratamento
4.
BMJ Open ; 12(2): e050635, 2022 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-35110310

RESUMO

INTRODUCTION: For many people with type 1 diabetes who struggle to achieve glycaemic control with multiple daily injections of insulin (MDI) plus self-monitoring of blood glucose, MDI plus intermittently scanned continuous glucose monitoring (IS-CGM) or real-time continuous glucose monitoring (RT-CGM), or insulin administration using insulin pump therapy represent optimised care in many regions. Through technological advances an advanced hybrid closed loop (AHCL) system has been developed; studies of incremental effects relative to MDI plus IS-CGM are lacking. METHODS AND ANALYSIS: The Advanced Hybrid Closed Loop study in Adult Population with Type 1 Diabetes (ADAPT) study is a multinational, prospective, open-label, confirmatory and exploratory randomised controlled trial to examine outcomes with the MiniMed 670G version 4.0 AHCL system (with an equivalent algorithm and commercialised as the MiniMed 780G system, referred to as AHCL) relative to MDI plus IS-CGM in adults with baseline HbA1c≥8.0%. An exploratory cohort will compare AHCL with MDI plus RT-CGM. The study will be conducted in approximately 124 adults on MDI plus either IS-CGM or RT-CGM for at least 3 months prior to screening. The primary endpoint will be the difference in mean HbA1c change from baseline to 6 months between the AHCL and the MDI plus IS-CGM arms. Secondary endpoints will include proportion of time spent in hypoglycaemic, euglycaemic and hyperglycaemic ranges. ETHICS AND DISSEMINATION: The ADAPT study will be conducted in accordance with the requirements of the Declaration of Helsinki and local laws and regulations, and has been approved by ethics committees. The trial will provide valuable information on the incremental benefits that may be provided by AHCL for patients failing to achieve glycaemic targets on MDI plus IS-CGM or RT-CGM and form a basis for health economic evaluations to support market access. TRIAL REGISTRATION NUMBER: NCT04235504; Pre-results.


Assuntos
Diabetes Mellitus Tipo 1 , Adulto , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto
5.
Diabetes Technol Ther ; 20(11): 758-766, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30325656

RESUMO

BACKGROUND: Sensor-integrated pump systems with low-glucose suspend (also known as threshold suspend) functions have markedly transformed the management of type 1 diabetes, but most studies to date have excluded patients at high risk of hypoglycemia. The SMILE study is investigating the efficacy of the MiniMed™ 640G insulin pump with the SmartGuard™ predictive low-glucose management (PLGM) feature in the prevention of hypoglycemia in adults with type 1 diabetes, who are at high risk of hypoglycemia. METHODS: SMILE is a prospective, randomized, open-label, controlled trial being undertaken in four European countries and Canada. Following a 2-week run-in phase, eligible participants will be randomized to use either the MiniMed 640G system with continuous glucose monitoring (CGM) and the SmartGuard PLGM feature on continuously for 24 weeks (treatment arm), or the MiniMed 640G without CGM and with blinded continuous glucose measurements between weeks 10-12, 16-18, and 22-24 (control arm). The primary endpoint is the mean number of hypoglycemic events, defined as sensor glucose ≤55 mg/dL (≤3.0 mmol/L) for >20 consecutive minutes. Secondary endpoints include various glycemic indices in the hypoglycemic and hyperglycemic ranges, as well as glycated hemoglobin. Data on patient-reported outcomes such as hypoglycemia awareness and treatment satisfaction will also be collected. CONCLUSIONS: It is anticipated that the SMILE study will provide important insights into the effectiveness of SmartGuard technology in adult patients with type 1 diabetes.


Assuntos
Automonitorização da Glicemia/métodos , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/prevenção & controle , Sistemas de Infusão de Insulina , Adulto , Glicemia/análise , Diabetes Mellitus Tipo 1/complicações , Feminino , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/etiologia , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Masculino , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Projetos de Pesquisa , Resultado do Tratamento
6.
Diabetes Technol Ther ; 18(5): 288-91, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26907513

RESUMO

BACKGROUND: The MiniMed 640G sensor-augmented insulin pump system (Medtronic, Inc., Northridge, CA) can automatically suspend insulin delivery in advance of predicted hypoglycemia and restart it upon recovery. The aims of this analysis were to determine the rate at which predicted hypoglycemia was avoided with this strategy, as well as to assess user acceptance of the system and its insulin management features. SUBJECTS AND METHODS: Forty subjects with type 1 diabetes used the system for 4 weeks. We retrospectively evaluated performance of the system, using downloaded pump and sensor data, and evaluated user acceptance via questionnaires. RESULTS: There were 2,322 suspend before low events (2.1 per subject-day). The mean (± SD) duration of pump suspension events was 56.4 ± 9.6 min, and the mean subsequent sensor glucose (SG) nadir was 71.8 ± 5.2 mg/dL. SG values following 1,930 (83.1%) of the predictive suspensions did not reach the preset low limit. Nadir SG values of ≤50 and ≤60 mg/dL were seen in 207 (8.9%) and 356 (15.3%) of the predictive suspensions, respectively. Blood glucose (BG) and SG values before and during the study were comparable (P > 0.05). The mean absolute relative difference between paired SG and BG values was 10.9 ± 13.8%. Subjects felt confident using the system, agreed that it helped protect them from hypoglycemia, and wished to continue using it. CONCLUSIONS: Automatic insulin pump suspension as implemented in the MiniMed 640G system can help patients avoid hypoglycemia, without significantly increasing hyperglycemia.


Assuntos
Hipoglicemia/prevenção & controle , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Adulto , Glicemia/análise , Criança , Humanos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...