Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 93(17): 6604-6612, 2021 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-33819029

RESUMO

The global prevalence of antibiotic-resistant bacteria has increased the risk of dangerous infections, requiring rapid diagnosis and treatment. The standard method for diagnosis of bacterial infections remains dependent on slow culture-based methods, carried out in central laboratories, not easily extensible to rapid identification of organisms, and thus not optimal for timely treatments at the point-of-care (POC). Here, we demonstrate rapid detection of bacteria by combining electrochemical immunoassays (EC-IA) for pathogen identification with confirmatory quantitative mass spectral immunoassays (MS-IA) based on signal ion emission reactive release amplification (SIERRA) nanoparticles with unique mass labels. This diagnostic method uses compatible reagents for all involved assays and standard fluidics for automatic sample preparation at POC. EC-IA, based on alkaline phosphatase-conjugated pathogen-specific antibodies, quantified down to 104 bacteria per sample when testing Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa lysates. EC-IA quantitation was also obtained for wound samples. The MS-IA using nanoparticles against S. aureus, E. coli, Klebsiella pneumoniae, and P. aeruginosa allowed selective quantitation of ∼105 bacteria per sample. This method preserves bacterial cells allowing extraction and amplification of 16S ribosomal RNA genes and antibiotic resistance genes, as was demonstrated through identification and quantitation of two strains of E. coli, resistant and nonresistant due to ß-lactamase cefotaximase genes. Finally, the combined immunoassays were compared against culture using remnant deidentified patient urine samples. The sensitivities for these immunoassays were 83, 95, and 92% for the prediction of S. aureus, P. aeruginosa, and E. coli or K. pneumoniae positive culture, respectively, while specificities were 85, 92, and 97%. The diagnostic platform presented here with fluidics and combined immunoassays allows for pathogen isolation within 5 min and identification in as little as 15 min to 1 h, to help guide the decision for additional testing, optimally only on positive samples, such as multiplexed or resistance gene assays (6 h).


Assuntos
Antibacterianos , Anti-Infecciosos , Antibacterianos/farmacologia , Farmacorresistência Bacteriana , Escherichia coli/genética , Bactérias Gram-Negativas , Bactérias Gram-Positivas , Humanos , Testes de Sensibilidade Microbiana , Staphylococcus aureus/genética
2.
Arch Autoimmune Dis ; 1(1): 17-27, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33511378

RESUMO

BACKGROUND: Diabetes is a complex, multi-symptomatic disease whose complications drives increases in healthcare costs as the diabetes prevalence grows rapidly world-wide. Real-world electronic health records (EHRs) coupled with patient biospecimens, biological understanding, and technologies can characterize emerging diagnostic autoimmune markers resulting from proteomic discoveries. METHODS: Circulating autoantibodies for C-terminal fragments of adiponectin receptor 1 (IgG-CTF) were measured by immunoassay to establish the reference range using midpoint samples from 1862 participants in a 20-year observational study of type 2 diabetes and cardiovascular arterial disease (CVAD) conducted by the Fairbanks Institute. The White Blood Cell elastase activity in these patients was assessed using immunoassays for Bikunin and Uristatin. Participants were assigned to four cohorts (healthy, T2D, CV, CV+T2D) based on analysis of their EHRs and the diagnostic biomarkers values and patient status were assessed ten-years post-sample. RESULTS: The IgG-CTF reference range was determined to be 75-821 ng/mL and IgG-CTF out-of-range values did not predict cohort or comorbidity as determined from the EHRs at 10 years after sample collection nor did IgG-CTF demonstrate a significant risk for comorbidity or death. Many patients at sample collection time had other conditions (hypertension, hyperlipidemia, or other risk factors) of which only hypertension, Uristatin and Bikunin values correlated with increased risk of developing additional comorbidities (odds ratio 2.58-13.11, P<0.05). CONCLUSIONS: This study confirms that retrospective analysis of biorepositories coupled with EHRs can establish reference ranges for novel autoimmune diagnostic markers and provide insights into prediction of specific health outcomes and correlations to other markers.

3.
Anal Chem ; 91(17): 11349-11354, 2019 09 03.
Artigo em Inglês | MEDLINE | ID: mdl-31398004

RESUMO

The worldwide increase in antimicrobial resistance is due to antibiotic overuse in agriculture and overprescription in medicine. For appropriate and timely patient support, faster diagnosis of antimicrobial resistance is required. Current methods for bacterial identification rely on genomics and proteomics and use comparisons with databases of known strains, but the diagnostic value of metabolites and lipids has not been explored significantly. Standard mass spectrometry/chromatography methods involve multiple dilutions during sample preparation and separation. To increase the amount of chemical information acquired and the speed of analysis of lipids, multiple reaction monitoring profiling (MRM-Profiling) has been applied. The MRM-Profiling workflow includes a discovery stage and a screening stage. The discovery stage employs precursor (PREC) ion and neutral loss (NL) scans to screen representative pooled samples for functional groups associated with particular lipid classes. The information from the first stage is organized in precursor/product ion pairs, or MRMs, and the screening stage rapidly interrogates individual samples for these MRMs. In this study, we performed MRM-Profiling of lipid extracts from four different strains of Escherichia coli cultured with amoxicillin or amoxicillin/clavulanate, a ß-lactam and ß-lactamase inhibitor, respectively. t tests, analysis of variance and receiver operating characteristic (ROC) curves were used to determine the significance of each MRM. Principal component analysis was applied to distinguish different strains cultured under conditions that allowed or disallowed development of bacterial resistance. The results demonstrate that MRM-Profiling distinguishes the lipid profiles of resistant and nonresistant E. coli strains.


Assuntos
Amoxicilina/farmacologia , Ácido Clavulânico/farmacologia , Resistência Microbiana a Medicamentos , Escherichia coli/química , Lipídeos/análise , Antibacterianos/farmacologia , Cromatografia Líquida de Alta Pressão , Escherichia coli/fisiologia , Espectrometria de Massas , Análise de Componente Principal , Curva ROC , beta-Lactamases/efeitos dos fármacos
4.
Anal Chem ; 91(3): 2028-2034, 2019 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-30609367

RESUMO

Herein is presented a platform capable of detecting less than 30 cells from a whole blood sample by size-exclusion filtration, microfluidic sample handling, and mass spectrometric detection through signal ion emission reactive release amplification (SIERRA). This represents an approximate 10-fold improvement in detection limits from previous work. Detection by SIERRA is accomplished through the use of novel nanoparticle reagents coupled with custom fluidic fixtures for precise sample transfer. Sample processing is performed in standardized 96-well microtiter plates with commonly available laboratory instrumentation to facilitate assay automation. The detection system is easily amenable to multiplex detection, and compatibility with PCR-based gene assays is demonstrated.


Assuntos
Técnicas Imunológicas , Técnicas Analíticas Microfluídicas , Nanotecnologia , Imagem Óptica , RNA Mensageiro/análise , Contagem de Células , Linhagem Celular Tumoral , Cromatografia em Gel , Humanos , Íons/química , Leucócitos/química , Espectrometria de Massas , Nanopartículas/química , RNA Mensageiro/genética , Reação em Cadeia da Polimerase em Tempo Real
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...