1.
J Clin Monit Comput ; 30(6): 985-994, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26563187

RESUMO

Increased extravascular lung water (EVLW) may contribute to respiratory failure in neonates. Accurate measurement of EVLW in these patients is limited due to the lack of bedside methods. The aim of this pilot study was to investigate the reliability of the transpulmonary ultrasound dilution (TPUD) technique as a possible method for estimating EVLW in a neonatal animal model. Pulmonary edema was induced in 11 lambs by repeated surfactant lavages. In between the lavages, EVLW indexed by bodyweight was estimated by TPUD (EVLWItpud) and transpulmonary dye dilution (EVLWItpdd) (n = 22). Final EVLWItpud measurements were also compared with EVLWI estimations by gold standard post mortem gravimetry (EVLWIgrav) (n = 6). EVLWI was also measured in two additional lambs without pulmonary edema. Bland-Altman plots showed a mean bias between EVLWItpud and EVLWItpdd of -3.4 mL/kg (LOA ± 25.8 mL/kg) and between EVLWItpud and EVLWIgrav of 1.7 mL/kg (LOA ± 8.3 mL/kg). The percentage errors were 109 and 43 % respectively. The correlation between changes in EVLW measured by TPUD and TPDD was r2 = 0.22. Agreement between EVLWI measurements by TPUD and TPDD was low. Trending ability to detect changes between these two methods in EVLWI was questionable. The accuracy of EVLWItpud was good compared to the gold standard gravimetric method but the TPUD lacked precision in its current prototype. Based on these limited data, we believe that TPUD has potential for future use to estimate EVLW after adaptation of the algorithm. Larger studies are needed to support our findings.


Assuntos
Água Extravascular Pulmonar , Termodiluição/métodos , Algoritmos , Animais , Débito Cardíaco , Cateterismo , Artéria Femoral/patologia , Hemodinâmica , Lesão Pulmonar/patologia , Edema Pulmonar/terapia , Reprodutibilidade dos Testes , Ovinos , Termogravimetria , Ultrassonografia
3.
Br J Anaesth ; 109(6): 870-8, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22907338

RESUMO

BACKGROUND: Transpulmonary ultrasound dilution (TPUD) is a promising method for cardiac output (CO) measurement in severely ill neonates. The incidence of lung injury in this population is high, which might influence CO measurement using TPUD because of altered lung perfusion. We evaluated the influence of lung injury on the accuracy and precision of CO measurement using TPUD in an animal model. METHODS: In nine neonatal lambs, central venous and arterial catheters were inserted and connected to the TPUD monitor. Repeated lavages with warmed isotonic saline were performed to gradually induce lung injury. CO measurements with TPUD (COtpud) were compared with those obtained by an ultrasonic transit-time flow probe around the main pulmonary artery (COufp). An increase in oxygenation index was used as an indicator of induced lung injury during the experiment. Post-mortem lung injury was confirmed by histopathological examination. RESULTS: Fifty-five sessions of three paired CO measurements were analysed. The mean COufp was 1.53 litre min(-1) (range 0.66-2.35 litre min(-1)), and the mean COtpud was 1.65 litre min(-1) (range 0.78-2.91 litre min(-1)). The mean bias (standard deviation) between the two methods was 0.13 (0.15) litre min(-1) with limits of agreement of ±0.29 litre min(-1). The overall percentage error was 19.1%. The accuracy and precision did not change significantly during progressive lung injury. Histopathological severity scores were consistent with heterogeneous lung injury. The capability to track changes in CO using TPUD was moderate to good. CONCLUSIONS: The accuracy and precision of CO measurement using TPUD is not influenced in the presence of heterogeneous lung injury in an animal model.


Assuntos
Débito Cardíaco , Lesão Pulmonar/veterinária , Monitorização Fisiológica/métodos , Monitorização Fisiológica/veterinária , Ultrassonografia/veterinária , Animais , Animais Recém-Nascidos , Cateterismo Venoso Central/instrumentação , Cateterismo Venoso Central/veterinária , Cateterismo Periférico/instrumentação , Cateterismo Periférico/veterinária , Modelos Animais de Doenças , Técnicas de Diluição do Indicador/instrumentação , Técnicas de Diluição do Indicador/veterinária , Lesão Pulmonar/fisiopatologia , Artéria Pulmonar/fisiopatologia , Reprodutibilidade dos Testes , Carneiro Doméstico , Ultrassonografia/instrumentação
4.
Br J Anaesth ; 108(3): 409-16, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22171359

RESUMO

BACKGROUND: Cardiac output (CO) monitoring remains complex in newborns as most of the current technologies fail to accurately measure systemic blood flow in the presence of shunts. We validated CO measurements using transpulmonary ultrasound dilution (TPUD) in a neonatal lamb model with a left-to-right shunt. METHODS: Regular arterial and central venous catheters were inserted into seven lambs (3.5-8.3 kg). A surgically constructed left-to-right aorto-pulmonary Gore-Tex(®) shunt was intermittently opened and closed, while CO was manipulated by creating haemorrhagic hypotension. CO measurements with TPUD (COtpud) were compared with those obtained by an ultrasonic transit-time flow probe positioned around the main pulmonary artery (COufp). RESULTS: We performed 72 sessions of three paired CO measurements. The mean COufp was 1.00 litre min(-1) (range 0.47-1.75 litre min(-1)) and mean COtpud 1.05 litre min(-1) (range 0.54-1.87 litre min(-1)). With an open shunt, the mean Qp/Qs ratio was 1.8 (range 1.3-2.6). A comparison between COufp and COtpud showed a mean bias (sd) of 0.03 (0.09) and 0.07 (0.10) litre min(-1), respectively, for measurements with a closed and an open shunt. The percentage error was 18% and 20% for measurements with a closed and an open shunt. Polar plot analysis showed good trending ability for both closed and open shunt groups. CONCLUSIONS: TPUD is a reliable technology to measure CO in the presence of a left-to-right shunt.


Assuntos
Débito Cardíaco/fisiologia , Permeabilidade do Canal Arterial/diagnóstico por imagem , Técnicas de Diluição do Indicador , Animais , Animais Recém-Nascidos , Cateterismo Cardíaco/métodos , Modelos Animais de Doenças , Permeabilidade do Canal Arterial/fisiopatologia , Estudos de Viabilidade , Modelos Animais , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Fluxo Sanguíneo Regional/fisiologia , Carneiro Doméstico , Ultrassonografia