Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Injury ; 55(1): 111183, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37981519

RESUMO

BACKGROUND: Truncal and junctional hemorrhage is the leading cause of potentially preventable deaths in trauma patients. To reduce this mortality, the application of advanced bleeding control techniques, such as resuscitative endovascular balloon occlusion of the aorta (REBOA), junctional tourniquets, Foley catheters, or hemostatic agents should be optimized. This study aimed to identify trauma patients with non-compressible truncal and junctional hemorrhage (NCTJH) who might benefit from advanced bleeding control techniques during initial trauma care. We hypothesized that there is a substantial cohort of Dutch trauma patients that can possibly benefit from advanced bleeding control techniques. METHODS: Adult trauma patients with an Abbreviated Injury Scale ≥3 in the torso, neck, axilla, or groin region, who were presented between January 1st, 2014 and December 31st, 2018 to two Dutch level-1 trauma centers, were identified from the Dutch Trauma Registry. Potential indications for advanced bleeding control in patients with NCTJH were assessed by an expert panel of three trauma surgeons based on injury characteristics, vital signs, response to resuscitation, and received treatment. RESULTS: In total, 1719 patients were identified of whom 249 (14.5 %) suffered from NCTJH. In 153 patients (60.6 %), hemorrhagic shock could have been mitigated or prevented with advanced bleeding control techniques. This group was younger and more heavily injured: median age of 40 versus 48 years and median ISS 33 versus 22 as compared to the entire cohort. The mortality rate in these patients was 31.8 %. On average, each of the included level-1 trauma centers treated an NCTJH patient every 24 days in whom a form of advanced bleeding control could have been beneficial. CONCLUSIONS: More than half of included Dutch trauma patients with NCTJH may benefit from in-hospital application of advanced bleeding control techniques, such as REBOA, during initial trauma care. Widespread implementation of these techniques in the Dutch trauma system may contribute to reduction of mortality and morbidity from non-compressible truncal and junctional hemorrhage.


Assuntos
Choque Hemorrágico , Centros de Traumatologia , Adulto , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Hemorragia/prevenção & controle , Tronco , Choque Hemorrágico/prevenção & controle
2.
J Trauma Acute Care Surg ; 94(4): 599-607, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36730102

RESUMO

BACKGROUND: Prompt bleeding control in the prehospital phase is essential to improve survival from catastrophic junctional hemorrhage. This study aimed to compare the effectiveness and practicality of Foley catheter balloon tamponade (FCBT), Celox-A, and XSTAT for the treatment of catastrophic hemorrhage from penetrating groin injuries with a small skin defect in a live-tissue porcine model. In addition, this study aimed to determine whether a training program could train military personnel in application of these advanced bleeding control adjuncts. METHODS: A standardized wound was created in 18 groins from 9 anesthetized swine. Eighteen military medics participated in the training program and performed a bleeding control procedure after randomization over the swine and test products and after transection of the femoral neurovascular bundle. Primary endpoints were bleeding control, time to bleeding control, rebleeding, blood loss, medic performance, and user product rating. RESULTS: No significant differences were found in vital signs and laboratory values between the groups. In the Celox-A group, 3/6 groins achieved hemorrhage control. This was 6/6 in the XSTAT and FCBT groups. XSTAT scored best on application time, time to obtain hemorrhage control, hemorrhage control score, and practicality. No significant differences were found between groups for rebleeding, amount of blood loss, and medic performance. Military medics had a significant higher preference for XSTAT over Celox-A. This was not significant for FCBT. CONCLUSION: All tested products proved effective in obtaining hemorrhage control. XSTAT has the highest effectivity and shortest application time for the treatment of catastrophic bleeding from nonpackable, penetrating junctional groin injuries with a small skin defect, compared with Celox-A and FCBT. XSTAT scored best on practicality. This study shows that our training curriculum can be used to train military medics with limited prior experience in the use of advanced bleeding control techniques for penetrating junctional groin injuries with small skin defect.


Assuntos
Hemostáticos , Ferimentos Penetrantes , Suínos , Animais , Virilha , Modelos Animais de Doenças , Hemorragia/terapia , Catéteres
3.
Injury ; 54(1): 214-222, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35948510

RESUMO

INTRODUCTION: Prompt and effective hemorrhage control is paramount to improve survival in patients with catastrophic bleeding. In the ever-expanding field of bleeding control techniques, there is a need for a realistic training model to practice these life-saving skills. This study aimed to create a realistic perfused post-mortem human specimen (PMHS) flow model that is suitable for training various bleeding control techniques. MATERIALS AND METHODS: This laboratory study was conducted in the SkillsLab & Simulation Center of Erasmus MC, University Medical Center Rotterdam, the Netherlands. One fresh frozen and five AnubiFiX® embalmed PMHS were used for the development of the model. Subsequent improvements in the exact preparation and design of the flow model were made based on model performance and challenges that occurred during this study and are described. RESULTS: Circulating arteriovenous flow with hypertonic saline was established throughout the entire body via inflow and outflow cannulas in the carotid artery and jugular vein of embalmed PMHS. We observed full circulation and major hemorrhage could be mimicked. Effective bleeding control was achieved by placing a resuscitative endovascular balloon occlusion of the aorta (REBOA) catheter in the model. Regional perfusion significantly reduced the development of tissue edema. CONCLUSION: Our perfused PMHS model with circulating arterial and venous flow appears to be a feasible method for the training of multiple bleeding control techniques. Regional arteriovenous flow successfully reduces tissue edema and increases the durability of the model. Further research should focus on reducing edema and enhancing the durability of the model.


Assuntos
Oclusão com Balão , Procedimentos Endovasculares , Humanos , Oclusão com Balão/métodos , Cadáver , Hemorragia/terapia , Aorta , Países Baixos , Ressuscitação/métodos
4.
J Trauma Acute Care Surg ; 93(2): 256-264, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35067523

RESUMO

BACKGROUND: Hemorrhage from truncal and junctional injuries is responsible for the vast majority of potentially survivable deaths in combat casualties, causing most of its fatalities in the prehospital arena. Optimizing the deployment of the advanced bleeding control modalities required for the management of these injuries is essential to improve the survival of severely injured casualties. This study aimed to establish consensus on the optimal use and implementation of advanced bleeding control modalities in combat casualty care. METHODS: A Delphi method consisting of three rounds was used. An international expert panel of military physicians was selected by the researchers to complete the Delphi surveys. Consensus was reached if 70% or greater of respondents agreed and if 70% or greater responded. RESULTS: Thirty-two experts from 10 different nations commenced the process and reached consensus on which bleeding control modalities should be part of the standard equipment, that these modalities should be available at all levels of care, that only trained physicians should be allowed to apply invasive bleeding control modalities, but all medical and nonmedical personnel should be allowed to apply noninvasive bleeding control modalities, and on the training requirements for providers. Consensus was also reached on the necessity of international registries and guidelines, and on certain indications and contraindications for resuscitative endovascular balloon occlusion of the aorta (REBOA) in military environments. No consensus was reached on the role of a wound clamp in military settings and the indications for REBOA in patients with chest trauma, penetrating axillary injury or penetrating neck injury in combination with thoracoabdominal injuries. CONCLUSION: Consensus was reached on the contents of a standard bleeding control toolbox, where it should be available, providers and training requirements, international registries and guidelines, and potential indications for REBOA in military environments.


Assuntos
Oclusão com Balão , Procedimentos Endovasculares , Aorta , Oclusão com Balão/métodos , Técnica Delphi , Procedimentos Endovasculares/efeitos adversos , Hemorragia/etiologia , Hemorragia/prevenção & controle , Humanos , Ressuscitação/métodos
5.
Eur J Trauma Emerg Surg ; 47(1): 57-69, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32472443

RESUMO

PURPOSE: Use of Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) as adjunct for temporary hemorrhage control in patients with exsanguinating torso hemorrhage is increasing. Characteristics of aortic occlusion balloons (AOB) are diverse and evolving as efforts are made to improve the technology. It is important to select a device that fits the requirements of the medical situation to minimize the risk of failure and complications. The aim of this study is to appraise guidance in the choice of an AOB in a specific situation. METHODS: We assessed 29 AOB for differences and outline possible advantages and disadvantages of each. Bending stiffness was measured with a three-point bending device. RESULTS: Diameter of the AOB ranged from 6 (ER-REBOA™) to 10 (Coda®-46) French. However, some need large-bore access sheaths up to 22 French (Fogarty®-45 and LeMaitre®-45) or even insertion via cut-down (Equalizer™-40). Bending stiffness varied from 0.08 N/mm (± 0.008 SD; Coda®-32) to 0.72 N/mm (± 0.024 SD; Russian prototype). Rescue Balloon™ showed kinking of the shaft at low bending pressures. The only non-compliant AOB is REBOA Balloon®. ER-REBOA™, Fogarty®, LeMaitre®, REBOA Balloon®, and Rescue Balloon™ are provided with external length marks to assist blind positioning. CONCLUSION: In resource-limited settings, a guidewire- and fluoroscopy-free, rather stiff device, such as ER-REBOA™, Fogarty®, and LeMaitre®, is warranted. Of these devices, ER-REBOA™ is the only catheter compatible with seven French sheaths and specifically designed for emergency hemorrhage control. Of the over-the-wire devices, Q50® has several features that facilitate use and reduce the risk of malplacement or vessel damage.


Assuntos
Aorta/cirurgia , Oclusão com Balão/instrumentação , Procedimentos Endovasculares/instrumentação , Hemorragia/cirurgia , Ressuscitação/instrumentação , Desenho de Equipamento , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...