Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Kardiologiia ; 64(4): 22-30, 2024 Apr 30.
Artigo em Russo, Inglês | MEDLINE | ID: mdl-38742512

RESUMO

AIM: To assess the role of clinical indicators and parameters of stress echocardiography performed according to an extended protocol as predictors for the occurrence of a composite cardiovascular endpoint (CCVEP) in IHD. MATERIAL AND METHODS: The study included 186 patients (60.2% men, mean age 60.6±9.9 years) with an established (n=73; 39.2%) and suspected (60.8%) diagnosis of IHD. Stress EchoCG with adenosine triphosphate (38.2%), transesophageal pacing (15.1%), dobutamine (2.6%), and bicycle ergometry on a recumbent ergometer (44.1%) was performed. The stress EchoCG protocol included assessment of regional wall motion abnormalities (WMA), B-lines, LV contractile reserve (CTR), coronary reserve (CR), and heart rate reserve. The median follow-up period was 13 [9; 20] months. The composite CCVEP included death from cardiovascular diseases and their complications, acute coronary syndrome, and revascularization and was defined at the first of these events. Statistical analysis was performed with the Statistica 16.0 and SPSS Statistics 23.0 software packages. Differences were considered statistically significant at p<0.05. RESULTS: Invasive or noninvasive coronary angiography was performed in 90.3% of patients; obstructive coronary disease (stenosis ≥50%) was detected in 67.9% of cases. During the follow-up period, 58 (31.2%) patients had cardiovascular complications. The risk of developing CCVEP was associated with the pretest probability (PTP) of ischemic heart disease (odds ratio, OR, 1.05; 95% confidence interval, CI, 1.02-1.08), dyslipidemia (DLP) (OR 0.40; 95% CI 0.20-0.82), carotid atherosclerosis (OR 0.39; 95% CI 0.18-0.86), LV ejection fraction (OR 0.96; 95% CI 0.93-0.99), appearance at peak stress of new significant (2 LV segments or more) regional WMAs (OR 0.32; 95% CI 0.18-6.55), decreased LV CTR (OR 0.46; 95% CI 0.27-0.79) and CR (OR 0.33; 95% CI 0.18-0.61); p<0.05 for all. In a multivariate analysis with Cox regression, the model with clinical indicators included PTP of IHD (OR 1.04; 95% CI 1.01-1.07; p=0.01) and DLP (OR 0.14; 95% CI 0.02-1.01; p=0.05) as predictors. The model with stress EchoCG parameters included the appearance of new significant WMAs (OR 0.33, 95% CI 0.16-0.65; p=0.001) and reduced <2.0 CR (OR 0.44; 95% CI 0.24-0.82; p=0.01). A comparative analysis of Kaplan-Meier curves confirmed statistically significant differences in the dynamics of the CCVEP occurrence depending on the absence or presence of hemodynamically significant WMAs and/or reduced CR during stress EchoCG (p<0.01). CONCLUSION: Reduced LV CR and WMA during stress EchoCG in patients with suspected or confirmed IHD are significant independent predictors for the CCVEP occurrence. Among clinical indicators, PTP of IHD and DLP are of the greatest importance for prognosis.


Assuntos
Ecocardiografia sob Estresse , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Ecocardiografia sob Estresse/métodos , Prognóstico , Doença das Coronárias/fisiopatologia , Idoso , Teste de Esforço/métodos , Angiografia Coronária/métodos
2.
Kardiologiia ; 64(3): 40-45, 2024 Mar 31.
Artigo em Russo, Inglês | MEDLINE | ID: mdl-38597761

RESUMO

AIM: Comparative analysis of the height of atherosclerotic plaques (AP) in the descending thoracic aorta (TA) according to two-dimensional (2D) and three-dimensional (3D) transesophageal echocardiography (TEE), and contrast-enhanced multislice computed tomography (MSCT). MATERIAL AND METHODS: The TA was examined using 2D, 3D TEE and contrast-enhanced MSCT in 34 patients (20 men and 14 women aged 68 [62; 71] years). AP heights were compared using the Bland-Altman method and the Spearman correlation analysis. This was a blinded comparative study which assessed the AP morphometry using each of the radiation modalities without knowing the results of the method being compared. RESULTS: 100 APs were examined in the descending TA. The mean height of all analyzed APs in the descending TA was 2.2 mm [2; 2.7] for 2D TEE, 3.1 mm [2.7; 3.55] for 3D TEE, and 3.05 mm [2.55; 3.55] for MSCT. The AP heights measured with 2D TEE was statistically significantly smaller than the heights of similar APs measured either with 3D TEE or MSCT. The mean difference (bias) was 0.88±0.34 mm between 2D and 3D TEE, and 0.83±0.41 mm between 2D TEE and MSCT. The correlation coefficients for the AP heights were r=0.87 (p<0.001) between 2D and 3D TEE and r=0.86 (p<0.001) between 2D TEE and MSCT. There were no differences in the height of similar APs between 3D TEE and MSCT. CONCLUSION: The three-dimensional reconstruction of AP in the TA by TEE is more accurate for quantitative assessment of AP than a two-dimensional study.


Assuntos
Ecocardiografia Tridimensional , Placa Aterosclerótica , Masculino , Humanos , Feminino , Aorta Torácica/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Ecocardiografia , Ecocardiografia Transesofagiana
3.
Kardiologiia ; 63(11): 64-72, 2023 Dec 05.
Artigo em Russo, Inglês | MEDLINE | ID: mdl-38088114

RESUMO

Aim      To study global aortic circumferential strain in normal conditions and in atherosclerosis of various grades and to determine its role in prediction of structural and functional disorders of the thoracic aorta (TA) and coronary atherosclerosis using 2D speckle-tracking transesophageal echocardiography.Material and methods  182 patients with typical or probable angina were examined. The control group consisted of 11 healthy volunteers. TA was visualized along its entire length. The height of each atheroma was measured, and the total number of plaques in the TA was determined. Five stages of TA atherosclerosis were identified. In the descending TA, the global peak systolic circumferential strain (GCS, %) and the global peak systolic circumferential strain normalized to pulse arterial pressure (PAP) (GCS / PAP∙100) were calculated. All patients underwent coronary angiography. The number of coronary arteries (CAs) with >50 % stenosis was determined, and the SYNTAX Score was calculated.Results TA atherosclerosis was not detected in the control group. Among 182 patients, stage 1-5 TA atherosclerosis was found in 23 (12.6 %), 103 (56.6 %), 43 (23.6 %), 7 (3.8 %), and 6 (3.4 %) cases respectively. GCS and GCS / PAD decreased as the ultrasound stage of TA atherosclerosis increased as compared with the control group: 9.2 % and 15.3 for the control group; stage 1, 5.6 % and 8.9 (p<0.001); stage 2, 4.1 % and 5.9 (p<0.001); stage 3, 4 % and 5.8 (p<0.001); stage 4, 3.7 % and 4.9 (p<0.01); and stage 5, 2.6 % and 3.3 (p<0.01), respectively. ROC analysis showed that GCS ≥5.9 % (area under the curve, AUC, 0.94±0.03; p<0.001) and GCS / PAD ≥11.4 (AUC, 0.97±0.02; p <0.001) were predictors of intact TA. Also, GCS ≤4.85 % (AUC, 0.82±0.04; p<0.001) and GCS / PAD ≤8.06 (AUC, 0.87±0.03; p<0.001) were predictors of hemodynamically significant TA atherosclerosis (stages 3-5). GCS ≤4.05 % (AUC, 0.62±0.04; p=0.007) and GCS / PAD ≤5.95 (AUC, 0.61±0.04; p=0.018) were predictors of hemodynamically significant (>50 %) stenosing atherosclerosis of at least one CA. Furthermore, GCS ≤3.75 % (AUC, 0.67±0.07; p=0.039) and GCS / PAD ≤5.15 (AUC, 0.64±0.07; p=0.045) were predictors of severe and advanced coronary atherosclerosis (SYNTAX Score ≥22).Conclusion      GCS and GCS / PAD are new diagnostic markers of structural and functional disorders of TA in atherosclerosis of various grades. GCS and GCS / PAD are independent predictors of high-grade TA atherosclerosis (stages 3-5) with GCS / PAD demonstrating the highest level of significance. GCS and GCS / PAD are non-invasive predictors of severe and advanced CA atherosclerosis.


Assuntos
Doenças da Aorta , Aterosclerose , Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , Doença da Artéria Coronariana/diagnóstico , Aorta Torácica/diagnóstico por imagem , Aterosclerose/diagnóstico , Ecocardiografia Transesofagiana , Angiografia Coronária , Placa Aterosclerótica/diagnóstico , Doenças da Aorta/diagnóstico , Doenças da Aorta/etiologia
4.
Khirurgiia (Mosk) ; (2): 67-74, 2022.
Artigo em Russo | MEDLINE | ID: mdl-35147003

RESUMO

The authors report a 76-year-old female with mega-aorta syndrome that was asymptomatic for a long time. The first symptoms appeared after ascending aorta enlargement up to 81 mm and compression of superior vena cava. The patient underwent frozen elephant trunk procedure. The authors demonstrate the possibilities of assessing the aortic strain by ECG-synchronized CT angiography and 2D transesophageal ultrasound with speckle tracking. Potential role of these methods in determining the type of aortic reconstruction is discussed.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Idoso , Dissecção Aórtica/cirurgia , Aorta/diagnóstico por imagem , Aorta/cirurgia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Feminino , Humanos , Stents , Resultado do Tratamento , Veia Cava Superior
5.
Kardiologiia ; 59(10S): 22-30, 2019 Sep 11.
Artigo em Russo | MEDLINE | ID: mdl-31876459

RESUMO

OBJECTIVES: To compare the possibilities and limitations of the two-dimensional (2D) and three-dimensional (3D) multiplane transesophageal echocardiography (TEE) for the diagnosis of the thoracic aorta (TA) atherosclerosis stage, qualitative and quantitative assessment of aortic atheromas and coronary atherosclerosis prediction. Materials and methods. 2D and 3D multiplane TEE of the TA was performed in 180 consecutive CAD patients (104 men, 76 women, mean age 62,4±7,5 years) using Philips IE33 xMatrix system and a X7-2t multiplane probe. Ascending aorta, accessible parts of the arch and descending TA were visualized in 2D mode with standard protocol using Live xPlane mode. 3D study of TA was performed using Live 3D and Full Volume modes. 2D and 3D studies were recorded as video clips series on a system hard drive with subsequent off line processing on a QLab 10.8 (Philips) workstation. Qualitative and quantitative assessment of every atheroma was performed using 2D and 3D modes. The degree of severity and distribution of the TA atheromatosis was evaluated according to the classification of ASE and EACVI (2015): grade 0 - intimal-medial thickness ≤1 mm, 1 - intimal thickness ≤2 mm, 2 - focal or diffuse intimal thickening of 2-3 mm (small atheromas), 3 - atheromas >3-5 mm (no mobile/ulcerated components), 4 - atheromas > 5 mm (no mobile/ulcerated components), 5 - grade 2, 3, or 4 atheromas plus mobile or ulcerated components. After TEE all patients underwent digital coronary angiography. SYNTAX Score was calculated in 122 (67,7%) patients with no coronary stents and bypass grafts. Results. 620 atheromas were analysed: 109 (17,6%) in the ascending part, 8 (1,3%) in the arch and 503 (81,1%) in the descending part. On average 3,4±2,1 atheromas per patient were revealed. Atheromas height in 3D was significantly higher (p<0,001), than in 2D, being 0,38±0,09 cm and 0,26±0,07 cm, respectively.  Averaged atheromas height increase in 3D was 0,12±0,06 cm. In 3D 87,7% of atheromas have shown irregular contours while in 2D only 35,4% of atheromas had rough countors. The mobile component in 6 (66,6%) out of 9 atheromas was revealed only in 3D. In 2D 1-5 stages of TA atheromatosis were revealed in 22 (12,2%), 103 (57,2%), 43 (23,9%), 7 (3,9%) and 4 (2,2%) cases, respectively. In 3D 1-5 stages of TA atheromatosis were revealed in 16 (8,9%), 25 (13,9%), 90 (50%), 38 (21,1%) and 10 (5,5%) cases, respectively. With 3D TEE 130 (72,2%) patients were found to have higher gradation of TA atheromatosis stage. TA atheromatosis was not detected in 1 (0,6%) patient. The direct Spearman's correlation between a stage of TA atheromatosis and SYNTAX Score which has been established for 2D rs =0,32 p<0,001 and 3D rs =0,30, p<0,01, respectively. Conclusion. A comparison between 2D and 3D TEE has shown, that 3D is more precise method of qualitative and quantitative assessment of aortic atheromas and diagnosis of TA atheromatosis stage which allows, ultimately, to change the stage of TA atheromatosis towards a higher gradation. 3D ultrasound stage of TA atheromatosis is a surrogate marker of the severity and prevalence of coronary atherosclerosis.


Assuntos
Doenças da Aorta , Aterosclerose , Ecocardiografia Tridimensional , Idoso , Aorta Torácica , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
6.
Kardiologiia ; 56(6): 18-25, 2016 06.
Artigo em Russo | MEDLINE | ID: mdl-28290842

RESUMO

Transthoracic echocardiography (TTE) has been described as an accurate technique for noninvasive evaluation of coronary flow reserve (CFR) of the left anterior descending artery (LAD) and posterior descending artery (PDA). Aim of this study was to find out whether serial measurement of CFR in LAD and PDA using TTE allows detection of stenosis elimination after intracoronary intervention and is a marker of successful procedure. METHODS: The study group comprised 14 patients with single-vessel coronary disease (stenosis 82+/-14%) of the LAD (9 patients) or right coronary artery (RCA, 5 patients) scheduled for stent implantation. All patients underwent dipyridamole stress echo with CFR evaluation of either distal LAD or PDA 1 day before and 6-9 days after successful stent implantation. CFR was calculated as the ratio of hyperemic to basal peak diastolic velocity. A CFR value of <2.0 was considered abnormal. RESULTS: Adequate Doppler signals to measure CFR were obtained in 13 patients (93%). Abnormal pre-procedure CFR value was revealed in 12 assessed patients (92%). Significant increase of CFR due to a decrease of coronary flow velocity at rest and its more pronounced hyperemic rise was found in all patients after stent implantation (CFR: 1.28+/-0.52 before and 2.53+/-0.37 after stenting; p<0.001). Using a cut-off value of CFR more or equal 2.0 to identify absence of significant coronary artery disease, TTE detected successful stent implantation with a sensitivity of 91.7% and specificity of 100% for both LAD and RCA. CFR was still abnormal in only 1 patient with pre-procedure>90% LAD stenosis. CONCLUSION: TTE is a feasible technique for serial CFR evaluation in LAD and PDA. Cut-off CFR value more or equal 2.0 is a sensitive and specific criterion of successful stent implantation in LAD and RCA.


Assuntos
Circulação Coronária , Ecocardiografia , Velocidade do Fluxo Sanguíneo , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
7.
Kardiologiia ; 56(4): 54-63, 2016 Apr.
Artigo em Russo | MEDLINE | ID: mdl-28294860

RESUMO

AIM: to assess additive diagnostic value of simultaneous evaluation of coronary flow reserve (CFR) in the left anterior descending (LAD) artery and posterior descending artery (PDA) during dipyridamole stress echocardiography (stress-Echo) for detection of LAD and PDA stenoses >50%. METHODS: 108 in-patients (mean age 50+/-11 years) with cardiac chest pain underwent dipyridamole stress-Echo with ECG-analysis, wall motion analysis by 2-dimentional imaging (2D) and coronary flow reserve (CFR) evaluation in both LAD and PDA by pulse-wave Doppler. The 2D test was considered positive when more or equal 2 segments demonstrated wall motion abnormalities. CFR was calculated as ratio of hyperemic to basal peak diastolic blood flow velocity. CFR <2.0 was considered reduced. Coronary angiography was performed within one week after stress-Echo. RESULTS: 34 of 97 patients with CFR in the LAD and wall motion in the LAD territory had LAD stenosis >50%, and 22 of 90 patients with evaluated CFR in the PDA and wall motion in the RCA territory had RCA stenosis >50%. Thus stenosis >50% was detected in 56 of 187 evaluated LAD and RCA. The 2D test and ECG results were positive for 35 arterial territories, reduced CFR - for 48 arteries. With combined evaluation of ECG, 2D test and CFR, accuracy was not significantly higher (80% for ECG+2D test, 82% for CFR and 80% for combined test) but sensitivity and negative predictive value increased (sensitivity: 63% for ECG+2D test, 86% for CFR and 91% for combined test; negative predictive value: 85% for ECG+2D test, 93% for CFR and 95% for combined test). CONCLUSION: Assessment of CFR in both LAD and PDA is feasible for majority of patients and can increase sensitivity and negative predictive value of dipyridamole stress-Echo for the detection.


Assuntos
Constrição Patológica/diagnóstico , Dipiridamol , Ecocardiografia sob Estresse , Adulto , Aorta , Velocidade do Fluxo Sanguíneo , Angiografia Coronária , Ecocardiografia Doppler , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
8.
Eur J Echocardiogr ; 5(1): 25-33, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15113009

RESUMO

AIM AND METHODS: The role of simultaneous transesophageal Doppler assessment of coronary flow reserve (CFR) in the left anterior descending artery (LAD) and coronary sinus (CS) in the diagnostics of hemodynamically significant LAD stenoses of various localization was studied in 16 CAD patients with angiographically proven >50% stenotic atherosclerosis of the LAD (nine--in the proximal third, seven--in the mid and/or distal third) and 23 healthy volunteers (all men). Dipyridamole was used as a stress agent. The diastolic phase of coronary flow in the LAD and the antegrade phase of coronary flow in the CS were analyzed. CFR in the LAD and CS was calculated in two ways: one--as ratio of peak hyperemic flow velocity to the peak baseline blood flow velocity (CFR by Vp); two--as ratio of volume hyperemic blood flow velocity to the volume baseline blood flow velocity (CFR by VBF). The level of the CFR <2 in both ways of calculation was diagnosed as reduced. RESULTS: It was found that in CAD patients with LAD proximal stenosis the values of CFR in the LAD were significantly lower than those in healthy individuals by both Vp (1.87 +/- 0.43 and 3.54 +/- 0.82; P<0.001) and VBF (1.79 +/- 0.77 and 3.85 +/- 1.25; P<0.01). In proximal stenosis CFR in the LAD by Vp was significantly lower than that in non-proximal stenosis (1.87 +/- 0.43 and 3.31 +/- 1.44; P<0.05). Sensitivity and specificity of CFR <2 in the LAD by Vp in the diagnostics of LAD proximal stenosis were 56% and 97%, respectively; and CFR <2 in the LAD by VBF--89% and 93%, respectively. In CAD patients with both proximal and non-proximal LAD stenoses CFR in the CS by Vp was significantly lower than that in healthy volunteers and was 1.74 +/- 0.53, 1.63 +/- 0.30 and 2.56 +/- 0.87; P<0.05, respectively. Sensitivity and specificity of CFR <2 in the CS by Vp in the diagnostics of hemodynamically significant LAD stenoses were 75% and 70%, respectively. The values of CFR in the CS by VBF in CAD patients and healthy volunteers did not differ significantly. CONCLUSIONS: Thus, simultaneous evaluation of CFR in the LAD and CS makes it possible to diagnose hemodynamically significant LAD stenoses and to differentiate between proximal and non-proximal impairments.


Assuntos
Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Ecocardiografia Transesofagiana/métodos , Volume Sistólico/fisiologia , Adulto , Análise de Variância , Velocidade do Fluxo Sanguíneo , Estudos de Casos e Controles , Angiografia Coronária , Circulação Coronária/fisiologia , Vasos Coronários/patologia , Dipiridamol , Ecocardiografia Doppler/métodos , Testes de Função Cardíaca , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Probabilidade , Valores de Referência , Estudos de Amostragem , Sensibilidade e Especificidade
9.
Eur J Echocardiogr ; 2(3): 170-7, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11882450

RESUMO

AIM AND METHODS: The possibility of using multiplane transoesophageal echocardiography (TEE) and quantitative coronary angiography (QCA) in the diagnostics of stenotic atherosclerosis of the main coronary arteries in a comparative aspect were studied in 94 patients with coronary artery disease (men, mean age 52 +/- 7 years). Coronary arteries stenoses were calculated with Doppler echocardiography using a modified continuity equation: stenosis (%)=100 x(1-prestenotic VTI(d)/stenotic VTI(d)) where prestenotic VTI(d), (cm)=diastolic velocity integral in the prestenotic zone, and stenotic VTI(d), (cm)=in the trans-stenotic zone. RESULTS: High sensitivity and specificity of TEE in the diagnostics of stenotic and occlusive atherosclerosis of coronary arteries were revealed. They measured 88% and 98% for the left main coronary artery (LMCA), 97% and 67% for the left descending artery (LDA), 95% and 92% for the circumflex artery (CX), 83% and 97% for the right coronary artery (RCA), respectively. A high correlation was found between the results of TEE and QCA in the diagnostics of coronary stenoses which were made for the LMCA (r=0.82P <0.001), LDA (r=0.84, P<0.001), CX (r=0.85,P <0.001), and RCA (r=0.84, P<0.001). We developed Doppler echocardiography criteria for haemodynamically significant stenoses of coronary arteries (>50%) according to a peak diastolic velocity of the coronary blood flow, calculated as 1.4m.s(-1)for the LMCA, 0.9m.s(-1)for the LDA, and 1.1m.s(-1)for the CX. We determined Doppler echocardiography criteria of coronary arteries occlusions such as a 'break' of colour mapping, absence of Doppler spectrum and retrograde blood flow during late diastole. CONCLUSION: Transoesophageal Doppler evaluation of coronary blood flow with application of a modified continuity equation is an accurate, non-invasive method of coronary arteries stenoses diagnostics.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Velocidade do Fluxo Sanguíneo , Circulação Coronária , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...