Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Nucl Med ; 48(3): 213-220, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36723880

RESUMO

PURPOSE: This study evaluated the performance of a drop-in gamma probe for prostate cancer (PCa) sentinel lymph node dissection (SLND) in a pelvic phantom, porcine model, and in PCa patients as part of an ongoing prospective multicenter clinical trial. METHODS: Two design variants of the drop-in gamma probe (SENSEI; Lightpoint Medical Ltd) were assessed in the pelvic phantom, and the preferred design was evaluated in a porcine model with clinically representative volumes and 99mTc activities. In the clinical trial, radical prostatectomy, SLND, and extended pelvic lymph node dissection were performed the day after 99mTc-nanocolloid injection and imaging. Sentinel lymph nodes (SLNs) were detected with the drop-in probe and a rigid laparoscopic gamma probe (RLGP). An interim analysis was performed after 10 patients were recruited. RESULTS: The narrow field of view probe design outperformed the wide field of view design in the pelvic phantom (detection rate, 100% vs 50%). In the porcine model, all activity concentrations could be successfully detected. The drop-in gamma probe successfully detected SLNs in all 10 patients (detection rate, 100%). Two of the SLNs identified by the drop-in gamma probe could not be found with the RLGP. No false-negative cases and no adverse events related to the SLND procedure or the drop-in gamma probe occurred. CONCLUSION: The drop-in gamma probe meets the usability and performance requirements for SLND in PCa and provides performance advantages over the RLGP. The final clinical study results will confirm the performance of the technique across multiple sites.


Assuntos
Neoplasias da Próstata , Linfonodo Sentinela , Masculino , Humanos , Animais , Suínos , Biópsia de Linfonodo Sentinela/métodos , Linfonodos/patologia , Estudos Prospectivos , Excisão de Linfonodo/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/cirurgia , Linfonodo Sentinela/patologia , Estadiamento de Neoplasias
2.
IEEE Trans Med Robot Bionics ; 4(2): 335-338, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-36148137

RESUMO

Surgical instrument segmentation and depth estimation are crucial steps to improve autonomy in robotic surgery. Most recent works treat these problems separately, making the deployment challenging. In this paper, we propose a unified framework for depth estimation and surgical tool segmentation in laparoscopic images. The network has an encoder-decoder architecture and comprises two branches for simultaneously performing depth estimation and segmentation. To train the network end to end, we propose a new multi-task loss function that effectively learns to estimate depth in an unsupervised manner, while requiring only semi-ground truth for surgical tool segmentation. We conducted extensive experiments on different datasets to validate these findings. The results showed that the end-to-end network successfully improved the state-of-the-art for both tasks while reducing the complexity during their deployment.

3.
IEEE Trans Radiat Plasma Med Sci ; 6(4): 446-453, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35419499

RESUMO

The challenge in delineating the boundary between cancerous and healthy tissue during cancer resection surgeries can be addressed with the use of intraoperative probes to detect cancer cells labeled with radiotracers to facilitate excision. In this study, deep learning algorithms for background gamma ray signal rejection were explored for an intraoperative probe utilizing CMOS monolithic active pixel sensors optimized toward the detection of internal conversion electrons from [Formula: see text]Tc. Two methods utilizing convolutional neural networks (CNNs) were explored for beta-gamma discrimination: 1) classification of event clusters isolated from the sensor array outputs (SAOs) from the probe and 2) semantic segmentation of event clusters within an acquisition frame of an SAO which provides spatial information on the classification. The feasibility of the methods in this study was explored with several radionuclides including 14C, 57Co, and [Formula: see text]Tc. Overall, the classification deep network is able to achieve an improved area under the curve (AUC) of the receiver operating characteristic (ROC), giving 0.93 for 14C beta and [Formula: see text]Tc gamma clusters, compared to 0.88 for a more conventional feature-based discriminator. Further optimization of the lower left region of the ROC by using a customized AUC loss function during training led to an improvement of 31% in sensitivity at low false positive rates compared to the conventional method. The segmentation deep network is able to achieve a mean dice score of 0.93. Through the direct comparison of all methods, the classification method was found to have a better performance in terms of the AUC.

4.
Nat Biomed Eng ; 6(5): 559-568, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35411113

RESUMO

In oncology, the feasibility of Cerenkov luminescence imaging (CLI) has been assessed by imaging superficial lymph nodes in a few patients undergoing diagnostic 18F-fluoro-2-deoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT). However, the weak luminescence signal requires the removal of ambient light. Here we report the development of a clinical CLI fiberscope with a lightproof enclosure, and the clinical testing of the setup using five different radiotracers. In an observational prospective trial (ClinicalTrials.gov identifier NCT03484884 ) involving 96 patients with existing or suspected tumours, scheduled for routine clinical FDG PET or 131I therapy, the level of agreement of CLI with standard-of-care imaging (PET or planar single-photon emission CT) for tumour location was 'acceptable' or higher (≥3 in the 1-5 Likert scale) for 90% of the patients. CLI correlated with the concentration of radioactive activity, and captured therapeutically relevant information from patients undergoing targeted radiotherapy or receiving the alpha emitter 223Ra, which cannot be feasibly imaged clinically. CLI could supplement radiological scans, especially when scanner capacity is limited.


Assuntos
Fluordesoxiglucose F18 , Neoplasias , Humanos , Luminescência , Medições Luminescentes/métodos , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons/métodos , Estudos Prospectivos
5.
J Nucl Med ; 63(1): 29-35, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33931467

RESUMO

Cerenkov luminescence imaging (CLI) is a novel imaging technology that might have the ability to assess surgical margins intraoperatively during prostatectomy using 68Ga-prostate-specific membrane antigen (68Ga-PSMA-11). This study evaluated the accuracy of CLI compared with histopathology and, as an exploratory objective, investigated the characteristics of the identified chemiluminescence signal. Methods: After intravenous injection of a mean 68Ga-PSMA-11 activity of 69 MBq intraoperatively, all excised specimens were imaged with CLI. Areas of increased signal were marked for histopathologic comparison and scored for the likelihood of being a positive surgical margin (PSM) using a 5-point Likert scale. In addition, the chemiluminescence signal was investigated in 3 radioactive and 3 nonradioactive specimens using CLI. Results: In 15 patients, the agreement between CLI and histopathology was 60%; this improved to 83% when including close surgical margins (≤1 mm). In 6 hot spots, CLI correctly identified PSMs on histopathology, located at the apex and mid prostate. In all 15 patients, an increased signal at the prostate base was observed, without the presence of the primary tumor in this area in 8 patients. This chemiluminescence signal was also observed in nonradioactive prostate specimens, with a half-life of 48 ± 11 min. The chemiluminescence hampered the visual interpretation of 4 PSMs at the base. Conclusion: CLI was able to correctly identify margin status, including close margins, in 83% of the cases. The presence of a diathermy-induced chemiluminescent signal hampered image interpretation, especially at the base of the prostate. In the current form, CLI is most applicable to detect PSMs and close margins in the apex and mid prostate.


Assuntos
Isótopos de Gálio , Radioisótopos de Gálio
6.
Sci Rep ; 11(1): 24002, 2021 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-34907289

RESUMO

Cerenkov luminescence imaging (CLI) is a promising approach to image-guided surgery and pathological sampling. It could offer additional advantages when combined to whole-body isotope tomographies. We aimed to obtain evidence of its applicability in lymphoma patho-diagnostics, thus we decided to investigate the radiodiagnostic potential of combined PET or SPECT/CLI in an experimental, novel spontaneous high-grade B-cell lymphoma mouse model (Bc.DLFL1). We monitored the lymphoma dissemination at early stage, and at clinically relevant stages such as advanced stage and terminal stage with in vivo 2-deoxy-2-[18F]fluoro-D-glucose (FDG) positron emission tomography (PET)/magnetic resonance imaging (MRI) and 67Ga-citrate single photon emission computed tomography (SPECT)/MRI. In vivo imaging was combined with ex vivo high resolution CLI. The use of CLI with 18F-Fluorine (F-18) and 67Ga-Gallium isotopes in the selection of infiltrated lymph nodes for tumor staging and pathology was thus tested. At advanced stage, FDG PET/MRI plus ex vivo CLI allowed accurate detection of FDG accumulation in lymphoma-infiltrated tissues. At terminal stage we detected tumorous lymph nodes with SPECT/MRI and we could report in vivo detection of the Cerenkov light emission of 67Ga. CLI with 67Ga-citrate revealed lymphoma accumulation in distant lymph node locations, unnoticeable with only MRI. Flow cytometry and immunohistochemistry confirmed these imaging results. Our study promotes the combined use of PET and CLI in preclinical studies and clinical practice. Heterogeneous FDG distribution in lymph nodes, detected at sampling surgery, has implications for tissue pathology processing and it could direct therapy. The results with 67Ga also point to the opportunities to further apply suitable SPECT radiopharmaceuticals for CLI.


Assuntos
Fluordesoxiglucose F18/farmacologia , Radioisótopos de Gálio/farmacologia , Medições Luminescentes , Linfoma/diagnóstico por imagem , Neoplasias Experimentais/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Animais , Camundongos , Camundongos Endogâmicos BALB C
7.
Int J Mol Sci ; 22(9)2021 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-33922728

RESUMO

Bc-DLFL.1 is a novel spontaneous, high-grade transplantable mouse B-cell lymphoma model for selective serosal propagation. These cells attach to the omentum and mesentery and show dissemination in mesenteric lymph nodes. We aimed to investigate its early stage spread at one day post-intraperitoneal inoculation of lymphoma cells (n = 18 mice), and its advanced stage at seven days post-inoculation with in vivo [18F]FDG-PET and [18F]PET/MRI, and ex vivo by autoradiography and Cherenkov luminescence imaging (CLI). Of the early stage group, nine animals received intraperitoneal injections, and nine received intravenous [18F]FDG injections. The advanced stage group (n = 3) received intravenous FDG injections. In the early stage, using autoradiography we observed a marked accumulation in the mesentery after intraperitoneal FDG injection. Using other imaging methods and autoradiography, following the intravenous injection of FDG no accumulations were detected. At the advanced stage, tracer accumulation was clearly detected in mesenteric lymph nodes and in the peritoneum after intravenous administration using PET. We confirmed the results with immunohistochemistry. Our results in this model highlight the importance of local FDG administration during diagnostic imaging to precisely assess early peritoneal manifestations of other malignancies (colon, stomach, ovary). These findings also support the importance of applying topical therapies, in addition to systemic treatments in peritoneal cancer spread.


Assuntos
Modelos Animais de Doenças , Glucose/metabolismo , Linfoma/patologia , Imagem Multimodal/métodos , Animais , Fluordesoxiglucose F18/metabolismo , Injeções Intraperitoneais , Metástase Linfática , Linfoma/diagnóstico por imagem , Camundongos , Camundongos Endogâmicos BALB C , Micrometástase de Neoplasia , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/metabolismo , Tomografia Computadorizada por Raios X/métodos
8.
EJNMMI Res ; 11(1): 28, 2021 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-33738563

RESUMO

INTRODUCTION: In women undergoing breast-conserving surgery (BCS), 20-25% require a re-operation as a result of incomplete tumour resection. An intra-operative technique to assess tumour margins accurately would be a major advantage. A novel method for intraoperative margin assessment was developed by applying a thin flexible scintillating film to specimens-flexible autoradiography (FAR) imaging. A single-arm, multi-centre study was conducted to evaluate the feasibility of intraoperative [18F]FDG FAR for the assessment of tumour margins in BCS. METHODS: Eighty-eight patients with invasive breast cancer undergoing BCS received ≤ 300 MBq of [18F]FDG 60-180 min pre-operatively. Following surgical excision, intraoperative FAR imaging was performed using the LightPath® Imaging System. The first 16 patients were familiarisation patients; the remaining 72 patients were entered into the main study. FAR images were analysed post-operatively by three independent readers. Areas of increased signal intensity were marked, mean normalised radiances and tumour-to-tissue background (TBR) determined, agreement between histopathological margin status and FAR assessed and radiation dose to operating theatre staff measured. Subgroup analyses were performed for various covariates, with thresholds set based on ROC curves. RESULTS: Data analysis was performed on 66 patients. Intraoperative margin assessment using FAR was completed on 385 margins with 46.2% sensitivity, 81.7% specificity, 8.1% PPV, 97.7% NPV and an overall accuracy of 80.5%, detecting both invasive carcinoma and DCIS. A subgroup analysis based on [18F]FDG activity present at time of imaging revealed an increased sensitivity (71.4%), PPV (9.3%) and NPV (98.4%) in the high-activity cohort with mean tumour radiance and TBR of 126.7 ± 45.7 photons/s/cm2/sr/MBq and 2.1 ± 0.5, respectively. Staff radiation exposure was low (38.2 ± 38.1 µSv). CONCLUSION: [18F]FDG FAR is a feasible and safe technique for intraoperative tumour margin assessment. Further improvements in diagnostic performance require optimising the method for scintillator positioning and/or the use of targeted radiopharmaceuticals. TRIAL REGISTRATION: Identifier: NCT02666079. Date of registration: 28 January 2016. URL: https://clinicaltrials.gov/ct2/show/NCT02666079 . ISRCTN registry: Reference: ISRCTN17778965. Date of registration: 11 February 2016. URL: http://www.isrctn.com/ISRCTN17778965 .

9.
Int J Comput Assist Radiol Surg ; 15(8): 1389-1397, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32556919

RESUMO

PURPOSE: In surgical oncology, complete cancer resection and lymph node identification are challenging due to the lack of reliable intraoperative visualization. Recently, endoscopic radio-guided cancer resection has been introduced where a novel tethered laparoscopic gamma detector can be used to determine the location of tracer activity, which can complement preoperative nuclear imaging data and endoscopic imaging. However, these probes do not clearly indicate where on the tissue surface the activity originates, making localization of pathological sites difficult and increasing the mental workload of the surgeons. Therefore, a robust real-time gamma probe tracking system integrated with augmented reality is proposed. METHODS: A dual-pattern marker has been attached to the gamma probe, which combines chessboard vertices and circular dots for higher detection accuracy. Both patterns are detected simultaneously based on blob detection and the pixel intensity-based vertices detector and used to estimate the pose of the probe. Temporal information is incorporated into the framework to reduce tracking failure. Furthermore, we utilized the 3D point cloud generated from structure from motion to find the intersection between the probe axis and the tissue surface. When presented as an augmented image, this can provide visual feedback to the surgeons. RESULTS: The method has been validated with ground truth probe pose data generated using the OptiTrack system. When detecting the orientation of the pose using circular dots and chessboard dots alone, the mean error obtained is [Formula: see text] and [Formula: see text], respectively. As for the translation, the mean error for each pattern is 1.78 mm and 1.81 mm. The detection limits for pitch, roll and yaw are [Formula: see text] and [Formula: see text]-[Formula: see text]-[Formula: see text] . CONCLUSION: The performance evaluation results show that this dual-pattern marker can provide high detection rates, as well as more accurate pose estimation and a larger workspace than the previously proposed hybrid markers. The augmented reality will be used to provide visual feedback to the surgeons on the location of the affected lymph nodes or tumor.


Assuntos
Laparoscopia/métodos , Neoplasias da Próstata/cirurgia , Cirurgia Assistida por Computador/métodos , Raios gama , Humanos , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/métodos
10.
Nano Lett ; 20(5): 3642-3650, 2020 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-32250635

RESUMO

Arrays of interacting 2D nanomagnets display unprecedented electromagnetic properties via collective effects, demonstrated in artificial spin ices and magnonic crystals. Progress toward 3D magnetic metamaterials is hampered by two challenges: fabricating 3D structures near intrinsic magnetic length scales (sub-100 nm) and visualizing their magnetic configurations. Here, we fabricate and measure nanoscale magnetic gyroids, periodic chiral networks comprising nanowire-like struts forming three-connected vertices. Via block copolymer templating, we produce Ni75Fe25 single-gyroid and double-gyroid (an inversion pair of single-gyroids) nanostructures with a 42 nm unit cell and 11 nm diameter struts, comparable to the exchange length in Ni-Fe. We visualize their magnetization distributions via off-axis electron holography with nanometer spatial resolution and interpret the patterns using finite-element micromagnetic simulations. Our results suggest an intricate, frustrated remanent state which is ferromagnetic but without a unique equilibrium configuration, opening new possibilities for collective phenomena in magnetism, including 3D magnonic crystals and unconventional computing.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA