Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bone Joint Res ; 6(1): 22-30, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28077394

RESUMO

OBJECTIVES: Up to 40% of unicompartmental knee arthroplasty (UKA) revisions are performed for unexplained pain which may be caused by elevated proximal tibial bone strain. This study investigates the effect of tibial component metal backing and polyethylene thickness on bone strain in a cemented fixed-bearing medial UKA using a finite element model (FEM) validated experimentally by digital image correlation (DIC) and acoustic emission (AE). MATERIALS AND METHODS: A total of ten composite tibias implanted with all-polyethylene (AP) and metal-backed (MB) tibial components were loaded to 2500 N. Cortical strain was measured using DIC and cancellous microdamage using AE. FEMs were created and validated and polyethylene thickness varied from 6 mm to 10 mm. The volume of cancellous bone exposed to < -3000 µÎµ (pathological loading) and < -7000 µÎµ (yield point) minimum principal (compressive) microstrain and > 3000 µÎµ and > 7000 µÎµ maximum principal (tensile) microstrain was computed. RESULTS: Experimental AE data and the FEM volume of cancellous bone with compressive strain < -3000 µÎµ correlated strongly: R = 0.947, R2 = 0.847, percentage error 12.5% (p < 0.001). DIC and FEM data correlated: R = 0.838, R2 = 0.702, percentage error 4.5% (p < 0.001). FEM strain patterns included MB lateral edge concentrations; AP concentrations at keel, peg and at the region of load application. Cancellous strains were higher in AP implants at all loads: 2.2- (10 mm) to 3.2-times (6 mm) the volume of cancellous bone compressively strained < -7000 µÎµ. CONCLUSION: AP tibial components display greater volumes of pathologically overstrained cancellous bone than MB implants of the same geometry. Increasing AP thickness does not overcome these pathological forces and comes at the cost of greater bone resection.Cite this article: C. E. H. Scott, M. J. Eaton, R. W. Nutton, F. A. Wade, S. L. Evans, P. Pankaj. Metal-backed versus all-polyethylene unicompartmental knee arthroplasty: Proximal tibial strain in an experimentally validated finite element model. Bone Joint Res 2017;6:22-30. DOI:10.1302/2046-3758.61.BJR-2016-0142.R1.

2.
Bone Joint J ; 98-B(12): 1625-1634, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27909124

RESUMO

AIMS: Risk of revision following total knee arthroplasty (TKA) is higher in patients under 55 years, but little data are reported regarding non-revision outcomes. This study aims to identify predictors of dissatisfaction in these patients. PATIENTS AND METHODS: We prospectively assessed 177 TKAs (157 consecutive patients, 99 women, mean age 50 years; 17 to 54) from 2008 to 2013. Age, gender, implant, indication, body mass index (BMI), social deprivation, range of movement, Kellgren-Lawrence (KL) grade of osteoarthritis (OA) and prior knee surgery were recorded. Pre- and post-operative Oxford Knee Score (OKS) as well as Short Form-12 physical (PCS) and mental component scores were obtained. Post-operative range of movement, complications and satisfaction were measured at one year. RESULTS: Overall, 44 patients with 44 TKAs (24.9%) under 55 years of age were unsure or dissatisfied with their knee. Significant predictors of dissatisfaction on univariate analysis included: KL grade 1/2 OA (59% dissatisfied), poor pre-operative OKS, complications, poor improvements in PCS and OKS and indication (primary OA 19% dissatisfied, previous meniscectomy 41%, multiply operated 42%, other surgery 29%, BMI > 40 kg/m2 31%, post-traumatic OA 45%, and inflammatory arthropathy 5%). Poor pre-operative OKS, poor improvement in OKS and post-operative stiffness independently predicted dissatisfaction on multivariate analysis. CONCLUSION: Patients receiving TKA younger than 55 years old should be informed about the increased risks of dissatisfaction. Offering TKA in KL 1/2 is questionable, with a dissatisfaction rate of 59%. Cite this article: Bone Joint J 2016;98-B:1625-34.


Assuntos
Artroplastia do Joelho/reabilitação , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Satisfação do Paciente/estatística & dados numéricos , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Índice de Massa Corporal , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Pobreza/estatística & dados numéricos , Prognóstico , Estudos Prospectivos , Desenho de Prótese , Radiografia , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento , Adulto Jovem
3.
Bone Joint J ; 95-B(10): 1339-47, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24078529

RESUMO

As many as 25% to 40% of unicompartmental knee replacement (UKR) revisions are performed for pain, a possible cause of which is proximal tibial strain. The aim of this study was to examine the effect of UKR implant design and material on cortical and cancellous proximal tibial strain in a synthetic bone model. Composite Sawbone tibiae were implanted with cemented UKR components of different designs, either all-polyethylene or metal-backed. The tibiae were subsequently loaded in 500 N increments to 2500 N, unloading between increments. Cortical surface strain was measured using a digital image correlation technique. Cancellous damage was measured using acoustic emission, an engineering technique that detects sonic waves ('hits') produced when damage occurs in material. Anteromedial cortical surface strain showed significant differences between implants at 1500 N and 2500 N in the proximal 10 mm only (p < 0.001), with relative strain shielding in metal-backed implants. Acoustic emission showed significant differences in cancellous bone damage between implants at all loads (p = 0.001). All-polyethylene implants displayed 16.6 times the total number of cumulative acoustic emission hits as controls. All-polyethylene implants also displayed more hits than controls at all loads (p < 0.001), more than metal-backed implants at loads ≥ 1500 N (p < 0.001), and greater acoustic emission activity on unloading than controls (p = 0.01), reflecting a lack of implant stiffness. All-polyethylene implants were associated with a significant increase in damage at the microscopic level compared with metal-backed implants, even at low loads. All-polyethylene implants should be used with caution in patients who are likely to impose large loads across their knee joint.


Assuntos
Artroplastia do Joelho/instrumentação , Hemiartroplastia/instrumentação , Prótese do Joelho , Tíbia/fisiopatologia , Acústica , Artroplastia do Joelho/métodos , Cimentos Ósseos , Hemiartroplastia/métodos , Humanos , Teste de Materiais/métodos , Metais , Polietileno , Desenho de Prótese , Processamento de Sinais Assistido por Computador , Estresse Mecânico , Tíbia/cirurgia , Suporte de Carga
4.
J Bone Joint Surg Br ; 94(8): 1051-7, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22844045

RESUMO

This prospective randomised controlled double-blind trial compared two types of PFC Sigma total knee replacement (TKR), differing in three design features aimed at improving flexion. The outcome of a standard fixed-bearing posterior cruciate ligament-preserving design (FB-S) was compared with that of a high-flexion rotating-platform posterior-stabilised design (RP-F) at one year after TKR. The study group of 77 patients with osteoarthritis of the knee comprised 37 men and 40 women, with a mean age of 69 years (44.9 to 84.9). The patients were randomly allocated either to the FB-S or the RP-F group and assessed pre-operatively and at one year post-operatively. The mean post-operative non-weight-bearing flexion was 107° (95% confidence interval (CI) 104° to 110°)) for the FB-S group and 113° (95% CI 109° to 117°) for the RP-F group, and this difference was statistically significant (p = 0.032). However, weight-bearing range of movement during both level walking and ascending a slope as measured during flexible electrogoniometry was a mean of 4° lower in the RP-F group than in the FB-S group, with 58° (95% CI 56° to 60°) versus 54° (95% CI 51° to 57°) for level walking (p = 0.019) and 56° (95% CI 54° to 58°) versus 52° (95% CI 48° to 56°) for ascending a slope (p = 0.044). Further, the mean post-operative pain score of the Western Ontario and McMaster Universities Osteoarthritis Index was significantly higher in the RP-F group (2.5 (95% CI 1.5 to 3.5) versus 4.2 (95% CI 2.9 to 5.5), p = 0.043). Although the RP-F group achieved higher non-weight-bearing knee flexion, patients in this group did not use this during activities of daily living and reported more pain one year after surgery.


Assuntos
Artroplastia do Joelho/instrumentação , Articulação do Joelho/fisiopatologia , Prótese do Joelho , Amplitude de Movimento Articular , Atividades Cotidianas , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/métodos , Artroplastia do Joelho/reabilitação , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/reabilitação , Osteoartrite do Joelho/cirurgia , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento , Caminhada/fisiologia
5.
J Bone Joint Surg Br ; 90(1): 37-42, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18160497

RESUMO

Modifications in the design of knee replacements have been proposed in order to maximise flexion. We performed a prospective double-blind randomised controlled trial to compare the functional outcome, including maximum knee flexion, in patients receiving either a standard or a high flexion version of the NexGen legacy posterior stabilised total knee replacement. A total of 56 patients, half of whom received each design, were assessed pre-operatively and at one year after operation using knee scores and analysis of range of movement using electrogoniometry. For both implant designs there was a significant improvement in the function component of the knee scores (p < 0.001) and the maximum range of flexion when walking on the level, ascending and descending a slope or stairs (all p < 0.001), squatting (p = 0.020) and stepping into a bath (p = 0.024). There was no significant difference in outcome, including the maximum knee flexion, between patients receiving the standard and high flexion designs of this implant.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Método Duplo-Cego , Feminino , Humanos , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Resultado do Tratamento
7.
Science ; 162(3851): 352, 1968 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-17836656

RESUMO

Ice towers, probably formed by recent fumarolic activity, have been found around the summit calderas of two volcanoes in Marie Byrd Land. These active (?) volcanoes lie within a broad belt of Mesozoic intrusion and late Cenozoic extrusion that appears to be part of the circum-Pacific orogenic province.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...