1.
Ann Pharm Fr ; 77(5): 418-425, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31296331

RESUMO

Cyclobenzaprine hydrochloride, a skeletal muscle relaxant has been determined using an ecofriendly micellar HPLC method in its pure form and tablets. The chromatographic determination was performed using C8 monolithic column (100mm×4.6mm i.d., 5µm particle size) and micellar eluent which was composed of sodium dodecyl sulfate (0.15M), n-propanol (15%), 0.02M orthophosphoric acid (pH 4.5) and 0.3% triethylamine using UV detection of effluent was set at 225nm. The calibration plot showed good linearity over concentration range from 2-40µg/mL. The assay results were statistically validated for linearity, accuracy, precision and specificity according to ICH guidelines. Additionally, regarding USP guidelines, the uniformity of tablets content and in-vitro dissolution test of the tablets was tested using the proposed method. Simple and rapid applicability of the developed method allowed determination of the drug in its pure and tablet dosage forms. Moreover, the major advantage of micellar HPLC technique is to determine the drug in biological fluids without prior extraction steps. Depending on this, the estimation of cyclobenzaprine in spiked human urine was so simple without traditional tedious procedures. The proposed method offers the advantages of sensitivity and simplicity in addition to short analysis time which didn't exceed 6 minutes.


Assuntos
Amitriptilina/análogos & derivados , Química Verde/métodos , Relaxantes Musculares Centrais/análise , Amitriptilina/análise , Amitriptilina/urina , Cromatografia Líquida de Alta Pressão , Suco Gástrico/química , Guias como Assunto , Humanos , Limite de Detecção , Micelas , Relaxantes Musculares Centrais/urina , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Solubilidade , Espectrofotometria Ultravioleta , Comprimidos/análise
2.
Ann Pharm Fr ; 77(1): 28-37, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30172351

RESUMO

Alfuzosin and tamsulosin are recently co-administrated with vardenafil to treat symptoms of benign prostatic hyperplasia and erectile dysfunction. A highly sensitive and simple liquid chromatographic method was developed and validated for the simultaneous determination of the three drugs using moxifloxacin as an internal standard. Isocratic separation was achieved within 7.0 min using phenyl-hexyl column (250 × 4.6 mm i.d.) and a mobile phase composed of acetonitrile/0.25% phosphoric acid (30:70, v/v) at pH 3.0. The analysis was performed at a flow rate of 1.2 mL/min with fluorescence detection at 246/450 nm for Alfuzosin and vardenafil, and 226/322nm for tamsulosin using time programming technique. The proposed method was linear over the concentration ranges of 5.0-50.0ng/mL, 10.0-200.0ng/mL and 20.0-400.0ng/mL for alfuzosin, vardenafil and tamsulosin, with limits of detection of 0.56ng/mL, 0.98ng/mL and 2.81 ng/mL in a respective order. The developed method was successfully applied to determine the studied drugs in dosage forms and human plasma samples and the results were satisfactory as revealed by statistical analysis of the data.


Assuntos
Antagonistas Adrenérgicos alfa/sangue , Anti-Hipertensivos/sangue , Quinazolinas/sangue , Tansulosina/sangue , Dicloridrato de Vardenafila/sangue , Vasodilatadores/sangue , Cromatografia Líquida de Alta Pressão , Composição de Medicamentos , Humanos , Masculino , Hiperplasia Prostática/tratamento farmacológico , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Fluorescência
3.
Luminescence ; 30(6): 823-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25611457

RESUMO

A highly sensitive, simple and rapid spectrofluorimetric method was developed for the determination of Amlexanox (AMX) in its bioadhesive buccal tablets. The proposed method is based on measuring the native fluorescence of the methanolic solution of AMX at 400 nm after excitation at 242 nm in 0.2 M borate buffer (pH 10) and 0.5% w/v sodium dodecyl sulfate (SDS) solution. The interaction of AMX with SDS was studied, and the enhanced fluorescence intensity was exploited to develop an assay method for the determination of AMX. The relative fluorescence intensity-concentration plot was rectilinear over the range 5.0-80.0 ng/mL, with a lower detection limit of 0.57 ng/mL and a lower quantification limit of 1.74 ng/mL. The proposed method was successfully applied to the analysis of AMX in its commercial tablets. Moreover, content uniformity testing was conducted by applying official USP guidelines. Statistical evaluation and comparison of the data obtained using the proposed and comparison methods revealed good accuracy and precision for the proposed method.


Assuntos
Aminopiridinas/análise , Espectrometria de Fluorescência/métodos , Comprimidos/análise , Administração Bucal , Concentração de Íons de Hidrogênio , Limite de Detecção , Micelas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dodecilsulfato de Sódio/química , Solventes , Comprimidos/química , Temperatura
4.
Luminescence ; 29(8): 1202-5, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24723476

RESUMO

A highly sensitive, simple and rapid spectrofluorimetric method was developed for the determination of amisulpride (AMS) and bumidazone (BUM) in tablet form. The proposed method is based on measuring the native fluorescence of the studied drugs in methanol at 360 and 344 nm after excitation at 276 and 232 nm for AMS and BUM, respectively. The fluorescence-concentration plots were rectilinear over the ranges of 5.0-60.0 ng/mL for AMS and 0.5-5.0 µg/mL for BUM. The lower detection limits were 0.70 ng/mL and 0.06 µg/mL, and the lower quantification limits were 2.0 ng/mL and 0.18 µg/mL for AMS and BUM, respectively. The method was successfully applied for the analysis of AMS and BUM in commercial tablets. Statistical evaluation and comparison of the data obtained using the proposed and comparison methods revealed good accuracy and precision for the proposed method.


Assuntos
Nitrocompostos/análise , Espectrometria de Fluorescência/métodos , Sulpirida/análogos & derivados , Amissulprida , Calibragem , Concentração de Íons de Hidrogênio , Limite de Detecção , Metanol/química , Reprodutibilidade dos Testes , Solventes/química , Sulpirida/análise , Comprimidos/análise
5.
J Fluoresc ; 24(2): 363-76, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24091803

RESUMO

A highly sensitive, simple and rapid stability-indicating spectrofluorimetric method was developed for the determination of metolazone (MET) and xipamide (XPM) in their tablets. The proposed method is based on the measurement of the native fluorescence of MET in methanol at 437 nm after excitation at 238 nm and XPM in alkaline methanolic solution at 400 nm after excitation at 255 nm. The fluorescence-concentration plots were rectilinear over the range of 2.0- 20.0 ng/mL for MET and 0.2- 2.0 µg/mL for XPM, with lower detection limits (LOD) of 0.35 ng/mL and 0.02 µg/mL and a lower quantification limit (LOQ) of 1.05 ng/mL and 0.07 µg/mL for MET and XPM, respectively. The method was successfully applied to the analysis of MET and XPM in their commercial tablets and the results were in good agreement with those obtained using the official and comparison methods, respectively. Furthermore, content uniformity testing of the studied pharmaceutical tablets was also conducted. The application of the proposed method was extended to stability studies of MET and XPM after exposure to different forced degradation conditions, such as acidic, alkaline, oxidative and photolytic degradation conditions, according to ICH Guidelines. Moreover, the method was utilized to investigate the kinetics of the alkaline, acidic and photolytic degradation of MET. The apparent first-order rate constants and half-life times were calculated. Proposals for the degradation pathways for both MET and XPM were postulated.


Assuntos
Metolazona/análise , Espectrometria de Fluorescência/métodos , Comprimidos/química , Xipamida/análise , Estabilidade de Medicamentos , Cinética , Limite de Detecção , Padrões de Referência
6.
Luminescence ; 27(6): 511-8, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22362604

RESUMO

A simple and sensitive spectrofluorimetric method has been developed and validated for the determination of oseltamivir phosphate (OST) in pharmaceutical preparations. The method is based on the reaction between oseltamivir phosphate and o-phthalaldehyde in presence of 2-mercapto-ethanol in borate buffer, pH 10.8, to give a highly fluorescent product measured at 450 nm after excitation at 336 nm. The different experimental parameters affecting the development and stability of the reaction product were studied and optimized. The fluorescence intensity-concentration plot is rectilinear over the range 0.05-1.0 µg/mL, with a lower detection limit of 5 ng/mL and limit of quantitation of 16 ng/mL. The developed method was successfully applied to the analysis of the drug in its commercial capsules and suspension, mean recoveries of OST were 99.97 ± 1.67% and 100.17 ± 1.18%, respectively (n = 3). Statistical comparison of the results obtained by the proposed and comparison method revealed no significant difference in the performance of the two methods regarding accuracy and precision. The proposed method was further extended to in vitro determination of the studied drug in spiked human plasma as a preliminary investigation; the mean recovery (n = 3) was 98.68 ± 5.8%. A reaction pathway was postulated.


Assuntos
Oseltamivir/análise , Espectrometria de Fluorescência/métodos , o-Ftalaldeído/química , Cápsulas/análise , Cápsulas/química , Fluorescência , Humanos , Concentração de Íons de Hidrogênio , Limite de Detecção , Mercaptoetanol/química , Oseltamivir/sangue , Oseltamivir/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Solventes , Temperatura
7.
J Chromatogr Sci ; 49(7): 495-501, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21801479

RESUMO

A simple, sensitive, stability-indicating HPLC method was developed and validated for the quantitative determination of the vasoprotective drug, naftazone in presence of its degradation products. The analysis was carried out on a Nucleosil 100-5 phenyl column (250 mm × 4.6 mm, 5 µm) using a mobile phase consisting of methanol-0.02 M sodium dihydrogen phosphate mixture (60:40, v/v) of pH 6.0. The analyses were performed at ambient temperature with a flow rate of 1.0 mL/min and UV detection at 270 nm. The method showed good linearity over the concentration range of 0.1-10.0 µg/mL with a lower detection limit of 0.032 and quantification limit of 0.096 µg/mL. The suggested method was successfully applied for the analysis of naftazone in its commercial tablets. Moreover, it was utilized to investigate the kinetics of alkaline, acidic and oxidative degradation of the drug. The apparent first-order rate constants, half-life times, and activation energies of the degradation process were calculated. The pH-rate profile curve was derived. Furthermore, the proposed method was successfully applied to the content uniformity testing of naftazone tablets.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Naftoquinonas/química , Estabilidade de Medicamentos , Cinética , Naftoquinonas/normas , Controle de Qualidade , Comprimidos/química , Comprimidos/normas
8.
Luminescence ; 26(6): 670-9, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21491578

RESUMO

A highly sensitive and simple spectrofluorimetric method was developed for the determination of loratadine (LRT) and desloratadine (DSL) in their pharmaceutical formulations. The proposed method is based on investigation of the fluorescence spectral behaviour of LRT and DSL in a sodium dodecyl sulphate (SDS) micellar system. In aqueous solution of acetate buffer of pH 4.5, the fluorescence intensities of both LRT and DSL were greatly enhanced (240%) in the presence of SDS. The fluorescence intensity was measured at 438 nm after excitation at 290 nm for both drugs. The fluorescence-concentration plots were rectilinear over the range 0.05-2.0 µg/mL for both LRT and DSL, with lower detection limits of 5.13 × 10(-3) and 6.35 × 10(-3) µg/mL for LRT and DSL, respectively. The method was successfully applied to the analysis of the two drugs in their commercial tablets, capsules and syrups, and the results were in good agreement with those obtained with the official or comparison methods. The proposed method is specific for the determination of LRT in the presence of other co-formulated drugs, such as pseudoephedrine. The application of the proposed method was extended to stability studies of LRT and DSL after exposure to different forced degradation conditions, such as acidic, alkaline and oxidative conditions, according to ICH guidelines.


Assuntos
Formas de Dosagem , Antagonistas não Sedativos dos Receptores H1 da Histamina/análise , Loratadina/análise , Micelas , Espectrometria de Fluorescência/métodos , Limite de Detecção , Reprodutibilidade dos Testes
9.
Luminescence ; 26(5): 342-8, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-20737649

RESUMO

A new, simple and sensitive spectrofluorimetric method has been developed for the determination of pregabalin (PG) in capsules. The method is based on the reaction between pregabalin and fluorescamine in borate buffer solution of pH 10 to give a highly fluorescent derivative that is measured at 487 nm after excitation at 390 nm. The different experimental parameters affecting the development and stability of the reaction product were carefully studied and optimized. The fluorescence intensity concentration plot was rectilinear over the range of 0.01-0.3 µg mL⁻¹ with a lower detection limit of 0.0017 µg mL⁻¹ and limit of quantitation of 0.005 µg mL⁻¹. The developed method was successfully applied to the analysis of the drug in its commercial capsules. The mean percentage recovery of PG in its capsule was 99.93±1.24 (n = 3). Statistical comparison of the results with those of the comparison method revealed good agreement and proved that there was no significant difference in the accuracy and precision of the two methods. A proposed reaction pathway was postulated.


Assuntos
Analgésicos/análise , Fluorescamina/química , Espectrometria de Fluorescência/métodos , Ácido gama-Aminobutírico/análogos & derivados , Cápsulas/análise , Pregabalina , Sensibilidade e Especificidade , Ácido gama-Aminobutírico/análise
10.
J Fluoresc ; 21(2): 715-22, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21046437

RESUMO

Sensitive and simple spectrophotometric (Method I) and spectrofluorimetric (Method II) methods were developed and validated for the determination of oxybutynin HCl (OXB) in its dosage forms. The method was based on the reaction of OXB with malonic acid anhydride in acetic acid anhydride to form a highly yellow colored product that was measured at 375 nm spectrophotometrically. The same reaction product exihibits strong fluorescence that was measured at 440 nm after excitation at 390 nm. The factors affecting formation and stability of the reaction product were carefully studied and optimized, and the reaction mechanism was postulated. The absorbance-concentration plot is rectilinear over the range 4-40 µg/mL with LOD of 1.12 µg/mL and LOQ of 3.39 µg/mL. The fluorescence-concentration plot is rectilinear over the range 0.5-6 µg/mL with LOD of 0.11 µg/mL and LOQ of 0.33 µg/mL. The method was applied to the analysis of commercial tablets Detronin® and Uripan®. Statistical comparison of the results with those of the reference method revealed good agreement and proved that there were no significant difference in the accuracy and precision between the two methods respectively. The study was extended to content uniformity testing.


Assuntos
Anidridos/química , Ácidos Mandélicos/análise , Ácidos Mandélicos/química , Preparações Farmacêuticas/química , Espectrofotometria/métodos , Temperatura Alta , Modelos Lineares , Malonatos/química , Reprodutibilidade dos Testes , Solventes/química , Espectrofotometria/economia , Fatores de Tempo
11.
Int J Biomed Sci ; 6(2): 141-9, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23675188

RESUMO

A simple and sensitive spectrophotometric method was developed for the determination of acetazolamide (ACM) in pure form and pharmaceutical preparations. The proposed method is based on the complex formation of acetazolamide with Palladium (II) chloride in acetate buffer pH5.4 and measuring the absorbance at 308 nm. The absorbance- concentration plot was rectilinear over the concentration range of 5-70 µg/ml with a minimum detection limit (LOD) of 0.98 µg/ml, limit of quantification (LOQ) of 2.96 µg/ml, and a molar absorptivity ζ=2.7 × 10(3) L/mol.cm. The factors affecting the absorbance of the formed complex were carefully studied and optimized. The composition of the complex as well as its stability constant was also investigated. The proposed method was applied for the determination of acetazolamide in its tablets and the results obtained were favorably compared with those obtained using the official method. A proposal of the reaction pathway was postulated.

12.
Int J Biomed Sci ; 6(2): 150-7, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23675189

RESUMO

A selective and simple spectrophotometric method has been developed for the determination of phenylpropanolamine HCl (PPA) in its dosage forms. The method was based on the formation of a colored N-vinyl chlorobenzoquinone derivative of PPA through its reaction with 2,3,5,6-tetrachloro-1,4-benzoquinone in presence of acetaldehyde. The colored product exhibits maximum absorbance at 650 nm. Different experimental parameters affecting formation and stability of the product were carefully studied and optimized. The stoichiometry of the reaction was determined, and the reaction pathway was postulated. The absorbance concentration plot was rectilinear over the range of 5-100 µg/mL with Limit of Detection (LOD) and Limit of Quantitation (LOQ) of 0.244 µg/mL and 0.74 µg/mL respectively. The analytical performance of the method was fully validated, and the results were satisfactory. The proposed method was successfully applied to the determination of PPA in its commercial dosage forms including tablets, capsules and syrups with good recoveries. Statistical comparison of the results with those of the comparison method showed good agreement and proved that there was no significant difference in the accuracy and precision between the reference and the proposed methods. The mechanism of the reaction pathway was postulated.

13.
Int J Biomed Sci ; 6(3): 252-9, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23675200

RESUMO

A simple and sensitive spectrophotometric method was developed for the determination of each of sertraline (SER) and paroxetine HCl (PXT) in dosage forms. The method is based upon reaction of PXT and SER with 2,4-dinitrofluorobenzene (DNFB) to form colored products. The absorbance of the products were measured at 375and 390 nm for SER and PXT respectively. The absorbance concentration plots were rectilinear over the concentration rang of 1-10 and 2-20 µg/mL with lower detection limits (LOD) of 0.11 and 0.28 µg/mL and quantification limits (LOQ) of 0.32 and 0.85 µg/mL for SER and PXT, respectively. The developed method was successfully applied for the determination of SER and PXT in dosage forms. The common excipients and additives did not interfere in their determinations. There was no significant difference between the results obtained by the proposed and the reference methods regarding Student t-test and the variance ratio F-test respectively. A proposal of the reaction pathway was postulated.

14.
Int J Biomed Sci ; 6(3): 268-75, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23675202

RESUMO

A simple and sensitive spectrofluorimetric method was developed for the determination of biotin in pure form and in pharmaceutical preparations. The proposed method is based on the oxidation of the drug with cerium (IV) ammonium sulfate in acidic medium. The fluorescence of the produced Cerium (III) was measured at 365 nm after excitation at 255 nm. The different experimental parameters affecting the development and stability of the reaction were carefully studied and optimized. The method is applicable over the concentration range of 30-120 ng/mL with correlation coefficient of 0.9998. The detection limit (LOD) of biotin was 2.41 ng/mL while quantitation limit (LOQ) was 7.29 ng/mL. The proposed procedure was successfully applied for the determination of biotin in pharmaceutical preparations with mean recoveries of 99.55 ± 0.83 and 101.67 ± 1.53 for biotin ampoules and capsules, respectively. The results obtained were in good agreement with those obtained using the official method.

15.
Int J Biomed Sci ; 6(4): 327-34, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23675210

RESUMO

Spectrophotometric and spectrofluorimetric methods were developed for the determination of dothiepin hydrochloride (DOP) in different dosage forms. The spectrophotometric method (Method I) is based on formation of a binary complex with eosin at 540 nm in acetate buffer of pH3.7. The absorbance-concentration plot is rectilinear over the range 1-10 µg/mL with LOD of 0.18 µg/mL and LOQ of 0.54 µg/mL. The spectroflurimetric method (Method II) is based on the quantitative quenching effect of Dothiepin on the native fluorescence of eosin at the same pH. The quenching of the fluorescence of eosin was measured at 543 nm after excitation at 304 nm. The fluorescence-concentration plot is rectilinear over the range 0.3-8 µg/ mL with LOD of 0.11 µg/mL and LOQ of 0.34 µg/mL. The proposed methods were successfully applied to the analysis of commercial tablets and capsules containing the drug. Statistical comparison of the results with those of the reference method revealed good agreement and proved that there were no significant differences in the accuracy and precision between the two methods respectively.

16.
J Fluoresc ; 19(5): 891-904, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19418209

RESUMO

A rapid, simple, and highly sensitive second-derivative synchronous fluorimetric (SDSF) method has been developed for the simultaneous analysis of binary mixtures of fluphenazine hydrochloride (FLZ) and nortriptyline hydrochloride (NTP) in their co-formulated tablets. The method is based upon measurement of the native fluorescence of these drugs at constant wavelength difference (Deltalambda) = 120 nm in acetic acid. The different experimental parameters affecting the fluorescence intensity of the studied drugs were carefully studied and optimized. The fluorescence-concentration plots were rectilinear over the range of 0.25-3.0 and 1-10 microg/ml for FLZ and NTP respectively, with lower detection limits (LOD) of 0.05 and 0.18 microg/ml and quantitation limits of 0.15 and 0.53 microg/ml for FLZ and NTP respectively. The proposed method was successfully applied for the determination of the studied compounds in their synthetic mixtures and in commercial co-formulated tablets. The results obtained were in good agreement with those obtained by the reference methods.


Assuntos
Flufenazina/análise , Nortriptilina/análise , Preparações Farmacêuticas/análise , Espectrometria de Fluorescência/métodos , Acetatos/química , Solventes/química , Espectrometria de Fluorescência/instrumentação , Fatores de Tempo
17.
J Fluoresc ; 19(2): 333-44, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18956234

RESUMO

A simple, economic, selective, and stability indicating spectrofluorimetric method was developed for the determination of famotidine (FMT); is based on its reaction with 9, 10-phenanthraquinone in alkaline medium to give a highly fluorescent derivative measured at 560 nm after excitation at 283 nm. The fluorescence intensity-concentration plot was rectilinear over the concentration range of 50-600 ng/ml with minimum quantification limit (LOQ) of 13.0 ng/ml and minimum detection limit (LOD) of 4.3 ng/ml. The factors affecting the development of the fluorescence intensity of the reaction product were carefully studied and optimized. The method was applied for the determination of FMT in its dosage forms. The stability of the compound was studied, and the proposed method was found to be stability indicating one. The results obtained were in good agreement with those obtained by the official method. Furthermore, the method was applied for the determination of FMT in spiked and real human plasma. The mean % recovery (n = 4) was found to be 99.94 +/- 0.24, and 105.13 +/- 0.64 for spiked and real human plasma, respectively. The composition of the reaction product as well as its stability constant was also investigated. Moreover, the method was utilized to investigate the kinetics of both alkaline and oxidative induced degradation of the drug. The apparent first order rate constant and half life time of the degradation product was calculated. A proposal of the reaction pathway was postulated.


Assuntos
Famotidina/análise , Fluorometria/métodos , Preparações Farmacêuticas/análise , Estabilidade de Medicamentos , Famotidina/sangue , Antagonistas dos Receptores H2 da Histamina , Humanos , Cinética
18.
Int J Biomed Sci ; 5(2): 146-57, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23675129

RESUMO

A simple and sensitive kinetic spectrofluorometric method was developed for the determination of some calcium channel blockers namely, verapamil hydrochloride, diltiazem hydrochloride, nicardipine hydrochloride and flunarizine. The method is based upon oxidation of the studied drugs with cerium (IV) ammonium sulphate in acidic medium. The fluorescence of the produced Ce (III) was measured at 365 nm after excitation at 255 nm. The different experimental parameters affecting the development and stability of the reaction product were carefully studied and optimized. The fluorescence-concentration plots were rectilinear for all the studied compounds over the concentration range of 0.01 to 0.12 µg mL(-1). The limits of detections for the studied compounds ranged from 2.93 × 10(-3) to 0.012 µg mL(-1) and limits of quantification from 9.76 × 10(-3) to 0.04 µg mL(-1) were obtained. The method was successfully applied to the analysis of commercial tablets. The results obtained were in good agreement with those obtained with reference methods.

19.
Int J Biomed Sci ; 5(2): 158-68, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23675130

RESUMO

A simple, sensitive and specific method was developed for the determination of famotidine (FMT) in pharmaceutical preparations and biological fluids. The proposed method is based on ternary complex formation of famotidine (FMT) with EDTA and terbium chloride TbCl3 in acetate buffer of pH 4. Alternatively, the complex is formed via the reaction with hexamine and either lanthanum chloride LaCl3, or cerous chloride CeCl3 in borate buffer of pH6.2 and 7.2 respectively. In all cases, the relative fluorescence intensity of the formed complexes was measured at 580 nm after excitation at 290 nm. The fluorescence intensity - concentration plots were rectilinear over the concentration range of 10-100, 5-70, and 5-60 ng/ml, with minimum quantification limits (LOQ) of 2.4, 2.2, and 5.2 ng/ml, and minimum limits of detection (LOD) of 0.79, 0.74, and 1.7 ng/ml upon using TbCl3, LaCl3, and CeCl3 respectively. The proposed method was applied successfully for the analysis of famotidine in dosage forms and in human plasma. The kinetics of both alkaline and oxidative induced degradation of the drug was studied using the proposed method. The apparent first order rate constant and half life time were calculated. A proposal of the reaction pathways is presented.

20.
J Pharm Biomed Anal ; 46(3): 491-7, 2008 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-18164891

RESUMO

Rapid and simple capillary electrophoresis (CE) methods were developed for the simultaneous determinations of cinnarizine and domperidone (CN/DOM) and cinnarizine and nicergoline (CN/NIC) in their co-formulated tablets. The optimized CE conditions were as follows: running buffer, methanol-acetate buffer (pH 3.0, 10 mM) (80:20 and 85:15 (v/v) for CN/DOM and CN/NIC, respectively); applied voltage, 20 kV; UV detection wavelengths, 215 and 227 nm for CN/DOM and CN/NIC, respectively; hydrodynamic injection was performed at a height of 25 mm for 30 s. Quinine hydrochloride and nicardipine hydrochloride were used as internal standards for the determination of CN/DOM and CN/NIC, respectively. Calibration curves were linear over the ranges 0.25-20/0.375-15 microg/ml (CN/DOM) and 0.25-25/0.4-10 microg/ml (CN/NIC) in each optimized condition. Detection limits were 0.074/0.119 microg/ml and 0.072/0.116 microg/ml for CN/DOM and CN/NIC, respectively. The proposed methods were successfully applied for the simultaneous determination of both CN/DOM and CN/NIC in their co-formulated tablets without interfering peaks due to the excipients present in the pharmaceutical tablets. The estimated amounts of CN/DOM and CN/NIC were almost identical with the certified values, and their percentage relative standard deviation values (%R.S.D.) were found to be < or =2.34% (n=3).


Assuntos
Cinarizina/análise , Eletroforese Capilar/métodos , Soluções Tampão , Química Farmacêutica , Cinarizina/química , Estabilidade de Medicamentos , Concentração de Íons de Hidrogênio , Comprimidos