Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(22)2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36433410

RESUMO

We built a high-speed TDS setup with the use of electronically controlled optical sampling (ECOPS), which can measure up to 1600 terahertz pulses per second. The movement of the sample was provided by two fast-speed motorized linear stages constituting the gantry. We developed a flat-bar-based metal marker approach for the synchronization of continuous line-by-line scans. We carefully compared the performance of the terahertz reflection time-domain spectroscopy (TDS) scanner operating in a slow point-by-point and a one-hundred-times faster line-by-line imaging scheme. We analyzed images obtained for both schemes for a uniform metallic breadboard with holes, as well as a glass composite sample with defects. Although the measurement time was reduced by 100 times in terms of the line-by-line scheme, the overall performance in both schemes was almost identical in terms of the defects' sizes, shapes and locations. The results proved that the proposed ECOPS TDS system can provide uniform and extremely fast scanning without any deterioration in image quality.

2.
Opt Express ; 29(16): 26191-26209, 2021 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-34614930

RESUMO

The linear complex refractive index of a set of borosilicate and tellurite as well as heavy metal oxide silicate, germanate and fluoride glasses has been determined using the Kramers-Kronig analysis on combined data from terahertz time domain (THz-TD) and Fourier transform infrared (FTIR) spectrometers in the ultrabroadband range of 0.15 THz to 200 THz. Debye, Lorentz and shape language modeling (SLM) approaches are applied. Far-infrared absorption power-law model parameters are determined via searching for the largest frequency range that minimizes the root mean squared error (RMSE) of a linear least squares fit for the set of glasses and other glass literature data. Relationships between the absorption parameters, glass properties and compositions are explored.

3.
Acta Pol Pharm ; 72(5): 851-66, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26665391

RESUMO

THz-TDS techniques are applied to investigate selected pharmaceutical samples. Investigations were performed on selected pharmaceutical samples with active pharmaceutical ingredients (API)--famotidine, ranitidine, fenofibrate, lovastatin, simvastatin, aspirin, ketoconazole, acyclovir (hydrated and non-hydrated), on excipients--lactose, glucose (hydrated and non-hydrated), Pluronic 127, and on mixtures of selected compounds. Pseudo-polymorphism effects are considered as well. Examples of the terahertz imaging technique are also given. APIs and excipients can be easily recognized in the terahertz band by their specific "fingerprints" as individual components and in mixtures. The hydration process as a variety of polymorphism can also be easily monitored using the THz technique. Moreover, terahertz light can be useful for the penetration of tablets, giving clear pictures of possible defects in tablet coatings.


Assuntos
Preparações Farmacêuticas/análise , Espectroscopia Terahertz/métodos , Excipientes/análise , Comprimidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...