Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38561572

RESUMO

BACKGROUND: Permanent pacing is often required following valve intervention (either surgical or percutaneous); however, tricuspid interventions pose specific challenges to conventional pacing. Therefore, leadless pacemaker (LP) implantation may be the preferred strategy when permanent pacing is required after tricuspid valve intervention. PURPOSE: To report periprocedural outcomes and follow-up of patients undergoing implantation of a LP system following tricuspid valve interventions. METHODS: Patients with previous tricuspid valve intervention at the time of attempted implantation of a LP (MicraTM, Medtronic, Minneapolis, MN, USA) were included. RESULTS: Between 2019 and 2022, 40 patients underwent LP implantations following tricuspid interventions in 5 large tertiary centers. The mean age was 68.9 ± 13.7 years, and 48% patients were male. The indication for pacing was as following: AVB in 27 (68%) patients, AF with slow ventricular response in 10 (25%) patients, and refractory rapid atrial fibrillation (AF) referred to AV junction ablation in 3 (7%) patients. Most of the patients received Micra VR (78%). The procedure was successful in all patients. The mean procedural time is 58 ± 32 min, and the median fluoroscopy time is 7.5 min. Electrical parameters were within normal range (threshold: 1.35 ± 1.2 V@0.24 ms, impedance: 772 ± 245 Ohm, R-wave: 6.9 ± 5.4 mV). No acute complications were observed. During a mean follow-up of 10 months, electrical parameters remained stable, and 4 deaths were occurred (not related to the procedure). CONCLUSION: A LP is a safe and efficient option following tricuspid valve interventions.

2.
J Am Heart Assoc ; 13(9): e032174, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38686874

RESUMO

BACKGROUND: A risk model has been proposed to provide a patient individualized estimation of risk for major clinical events (heart failure events, ventricular arrhythmia, all-cause mortality) in patients with transposition of the great arteries and atrial switch surgery. We aimed to externally validate the model. METHODS AND RESULTS: A retrospective, multicentric, longitudinal cohort of 417 patients with transposition of the great arteries (median age, 24 years at baseline [interquartile range, 18-30]; 63% men) independent of the model development and internal validation cohort was studied. The performance of the prediction model in predicting risk at 5 years was assessed, and additional predictors of major clinical events were evaluated separately in our cohort. Twenty-five patients (5.9%) met the major clinical events end point within 5 years. Model validation showed good discrimination between high and low 5-year risk patients (Harrell C index of 0.73 [95% CI, 0.65-0.81]) but tended to overestimate this risk (calibration slope of 0.20 [95% CI, 0.03-0.36]). In our population, the strongest independent predictors of major clinical events were a history of heart failure and at least mild impairment of the subpulmonary left ventricle function. CONCLUSIONS: We reported the first external validation of a major clinical events risk model in a large cohort of adults with transposition of the great arteries. The model allows for distinguishing patients at low risk from those at intermediate to high risk. Previous episode of heart failure and subpulmonary left ventricle dysfunction appear to be key markers in the prognosis of patients. Further optimizing risk models are needed to individualize risk predictions in patients with transposition of the great arteries.


Assuntos
Transposição das Grandes Artérias , Insuficiência Cardíaca , Transposição dos Grandes Vasos , Humanos , Masculino , Feminino , Transposição dos Grandes Vasos/cirurgia , Adulto , Medição de Risco/métodos , Estudos Retrospectivos , Adulto Jovem , Fatores de Risco , Transposição das Grandes Artérias/efeitos adversos , Adolescente , Insuficiência Cardíaca/diagnóstico , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Estudos Longitudinais , Fatores de Tempo
3.
Artigo em Inglês | MEDLINE | ID: mdl-38534004

RESUMO

INTRODUCTION: Pacemaker implantation can be challenging in patients with congenital heart disease. METHODS AND RESULTS: In a patient with Ebstein disease and symptomatic sinus node dysfunction, despite multiple attempts, the Micra® pacemaker could not be implanted in the severely dilated right ventricle. In that context, and after iodine injection to confirm the appropriate location, the Micra® pacemaker was successfully implanted in the right appendage at the first attempt. CONCLUSION: Despite the recent development of dedicated dual-chamber leadless pacemaker, to the best of our knowledge, this case is the first off-label Micra® implantation in a right appendage.

4.
J Clin Med ; 12(19)2023 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-37834826

RESUMO

Aim: International guidelines on the use of anti-thrombotic therapies in left-sided ablations other than atrial fibrillation (AF) are lacking. The data regarding antiplatelet or anticoagulation strategies after catheter ablation (CA) procedures mainly derive from AF, whereas for the other arrhythmic substrates, the anti-thrombotic approach remains unclear. This survey aims to explore the current practices regarding antithrombotic management before, during, and after left-sided endocardial ablation, not including atrial fibrillation (AF), in patients without other indications for anti-thrombotic therapy. Material and Methods: Electrophysiologists were asked to answer a questionnaire containing questions on antiplatelet (APT) and anticoagulation therapy for the following left-sided procedures: accessory pathway (AP), atrial (AT), and ventricular tachycardia (VT) with and without structural heart disease (SHD). Results: We obtained 41 answers from 41 centers in 15 countries. For AP, before ablation, only four respondents (9.7%) used antiplatelets and two (4.9%) used anticoagulants. At discharge, APT therapy was prescribed by 22 respondents (53.7%), and oral anticoagulant therapy (OAC) only by one (2.4%). In patients with atrial tachycardia (AT), before ablation, APT prophylaxis was prescribed by only four respondents (9.7%) and OAC by eleven (26.8%). At discharge, APT was recommended by 12 respondents (29.3%) and OAC by 24 (58.5%). For VT without SHD, before CA, only six respondents (14.6%) suggested APT and three (7.3%) suggested OAC prophylaxis. At discharge, APT was recommended by fifteen respondents (36.6%) and OAC by five (12.2%). Regarding VT in SHD, before the procedure, eight respondents (19.5%) prescribed APT and five (12.2%) prescribed OAC prophylaxis. At discharge, the administration of anti-thrombotic therapy depended on the LV ejection fraction for eleven respondents (26.8%), on the procedure time for ten (24.4%), and on the radiofrequency time for four (9.8%), with a cut-off value from 1 to 30 min. Conclusions: Our survey indicates that the management of anti-thrombotic therapy surrounding left-sided endocardial ablation of patients without other indications for anti-thrombotic therapy is highly variable. Further studies are necessary to evaluate the safest approach to these procedures.

5.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37695311

RESUMO

AIMS: The incidence of atrial tachyarrhythmias is high in patients with atrioventricular septal defect (AVSD). No specific data on catheter ablation have been reported so far in this population. We aimed to describe the main mechanisms of atrial tachyarrhythmias in patients with AVSD and to analyse outcomes after catheter ablation. METHODS AND RESULTS: This observational multi-centric cohort study enrolled all patients with AVSD referred for catheter ablation of an atrial tachyarrhythmia at six tertiary centres from 2004 to 2022. The mechanisms of the different tachyarrhythmias targeted were described and outcomes were analysed. Overall, 56 patients (38.1 ± 17.4 years, 55.4% females) were included. A total of 87 atrial tachyarrhythmias were targeted (mean number of 1.6 per patient). Regarding main circuits involved, a cavo-annular isthmus-dependent intra-atrial re-entrant tachycardia (IART) was observed in 41 (73.2%) patients and an IART involving the right lateral atriotomy in 10 (17.9%) patients. Other tachyarrhythmias with heterogeneous circuits were observed in 13 (23.2%) patients including 11 left-sided and 4 right-sided tachyarrhythmias. Overall, an acute success was achieved in 54 (96.4%) patients, and no complication was reported. During a mean follow-up of 2.8 ± 3.8 years, 22 (39.3%) patients had at least one recurrence. Freedom from atrial tachyarrhythmia recurrences was 77.5% at 1 year. Among 15 (26.8%) patients who underwent repeated ablation procedures, heterogeneous circuits including bi-atrial and left-sided tachyarrhythmias were more frequent. CONCLUSION: In patients with AVSD, most circuits involve the cavo-annular isthmus, but complex mechanisms are frequently encountered in patients with repeated procedures. The acute success rate is excellent, although recurrences remain common during follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Feminino , Humanos , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos de Coortes , Taquicardia/diagnóstico , Taquicardia/cirurgia , Ablação por Cateter/efeitos adversos , Recidiva
6.
J Am Coll Cardiol ; 82(11): 1108-1120, 2023 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-37673512

RESUMO

Patients with congenital heart disease associated with a higher risk for ventricular arrhythmias (VA) and sudden cardiac death (SCD) can be divided conceptually into those with discrete mechanisms for reentrant monomorphic ventricular tachycardia (VT) (Group A) and those with more diffuse substrates (Group B). Part I of this review addresses Group A lesions, which predominantly consist of tetralogy of Fallot and related variants. Well-defined anatomic isthmuses for reentrant monomorphic VT are interposed between surgical scars and the pulmonary or tricuspid annulus. The most commonly implicated critical isthmus for VT is the conal septum that divides subpulmonary from subaortic outlets. Programmed ventricular stimulation can be helpful in risk stratification. Although catheter ablation is not generally considered an alternative to the implantable cardioverter-defibrillator (ICD) for prevention of SCD, emerging data suggest that there is a subset of carefully selected patients who may not require ICDs after successful monomorphic VT ablation.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Cardiopatias Congênitas , Humanos , Adulto , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/terapia
7.
J Am Coll Cardiol ; 82(11): 1121-1130, 2023 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-37673513

RESUMO

There are marked variations in the incidence of sudden cardiac death (SCD) and in the substrates for ventricular arrhythmias (VAs) across the gamut of congenital heart defects. In this 2-part review, patients with higher-risk forms of congenital heart disease (CHD) were conceptually categorized into those with discrete anatomic isthmuses for macro-reentrant ventricular tachycardia (VT) (Group A) and those with more diffuse or less well-defined substrates (Group B) that include patchy or extensive myocardial fibrosis. The latter category encompasses CHD lesions such as Ebstein anomaly, transposition of the great arteries with a systemic right ventricle (RV), and congenital aortic stenosis. For Group B patients, polymorphic VT and ventricular fibrillation account for a higher proportion of VA. The prognostic value of programmed ventricular stimulation is less well established, and catheter ablation plays a less prominent role. As cardiomyopathies evolve over time, pathophysiological mechanisms for VA among Groups A and B become increasingly blurred.


Assuntos
Anomalia de Ebstein , Cardiopatias Congênitas , Taquicardia Ventricular , Transposição dos Grandes Vasos , Humanos , Adulto , Cardiopatias Congênitas/complicações , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/etiologia
8.
Heart Rhythm ; 20(12): 1689-1696, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37598989

RESUMO

BACKGROUND: Patients with repaired tetralogy of Fallot (TOF) are at risk for ventricular tachycardia (VT) related to well-described anatomical isthmuses. OBJECTIVE: The purpose of this study was to explore QRS morphology as an indicator of anatomical isthmus conduction. METHODS: Patients with repaired TOF and complete right bundle branch block referred for transcatheter pulmonary valve replacement (PVR) or presenting with sustained VT underwent comprehensive 3-dimensional mapping in sinus rhythm. Electrocardiographic characteristics were compared to right ventricular (RV) activation and anatomical isthmus conduction properties. RESULTS: Twenty-two patients (19 pre-pulmonary valve replacement and 3 clinical VT) underwent comprehensive 3-dimensional mapping (median 39 years; interquartile range [IQR] 27-48 years; 12 [55%] male). Septal RV activation (median 40 ms; IQR 34-46 ms) corresponded to the nadir in lead V1 and free wall activation (median 71 ms; IQR 64-81 ms) to the transition point in the upstroke of the R' wave. Patients with isthmus block between the pulmonary annulus and the ventricular septal defect patch and between the ventricular septal defect patch and the tricuspid annulus (when present), were more likely to demonstrate lower amplitude R' waves in lead V1 (5.8 mV vs 9.4 mV; P = .005), QRS fragmentation in lead V1 (15 [94%] vs 2 [13%]; P < .001), and terminal S waves in lead aVF (15 [94%] vs 6 [40%]; P < .001) than those with intact conduction. During catheter ablation, these QRS changes developed during isthmus block. CONCLUSION: For patients with repaired TOF, the status of septal isthmus conduction was evident from sinus rhythm QRS morphology. Low-amplitude, fragmented R' waves in lead V1 and terminal S waves in the inferior leads were related to septal isthmus conduction abnormalities, providing a mechanistic link between RV activation and common electrocardiographic findings.


Assuntos
Comunicação Interventricular , Taquicardia Ventricular , Tetralogia de Fallot , Humanos , Masculino , Feminino , Tetralogia de Fallot/complicações , Tetralogia de Fallot/diagnóstico , Tetralogia de Fallot/cirurgia , Ventrículos do Coração , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas , Eletrocardiografia/métodos
9.
Am J Cardiol ; 204: 14-21, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37536198

RESUMO

Patients with repaired tetralogy of Fallot are at elevated risk for ventricular arrhythmia and sudden cardiac death. Over the past decade, the pathogenesis and natural history of ventricular tachycardia has become increasingly understood, and catheter ablation has emerged as an effective treatment modality. Concurrently, there has been great progress in the development of a versatile array of transcatheter valves that can be placed in the native right ventricular outflow tract for the treatment of long-standing pulmonary regurgitation. Although such valve platforms may eliminate the need for repeat cardiac operations, they may also impede catheter access to the myocardial substrates responsible for sustained macro-reentrant ventricular tachycardia. This manuscript provides the rationale and design of a recently devised multicenter study that will examine the clinical outcomes of a uniform, preemptive strategy to eliminate ventricular tachycardia substrates before transcatheter pulmonary valve implantation in patients with tetralogy of Fallot.


Assuntos
Ablação por Cateter , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Pulmonar , Valva Pulmonar , Taquicardia Ventricular , Tetralogia de Fallot , Humanos , Tetralogia de Fallot/complicações , Tetralogia de Fallot/cirurgia , Valva Pulmonar/cirurgia , Arritmias Cardíacas , Insuficiência da Valva Pulmonar/cirurgia , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos
10.
J Am Coll Cardiol ; 82(7): 590-599, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37558371

RESUMO

BACKGROUND: Very few data have been published on the use of subcutaneous implantable cardioverter-defibrillators (S-ICDs) in patients with congenital heart disease (CHD). OBJECTIVES: The aim of this study was to analyze outcomes associated with S-ICDs in patients with CHD. METHODS: This nationwide French cohort including all patients with an S-ICD was initiated in 2020 by the French Institute of Health and Medical Research. Characteristics at implantation and outcomes were analyzed in patients with CHD. RESULTS: From October 12, 2012, to December 31, 2019, among 4,924 patients receiving an S-ICD implant in 150 centers, 101 (2.1%) had CHD. Tetralogy of Fallot, univentricular heart, and dextro-transposition of the great arteries represented almost one-half of the population. Patients with CHD were significantly younger (age 37.1 ± 15.4 years vs 50.1 ± 14.9 years; P < 0.001), more frequently female (37.6% vs 23.0%; P < 0.001), more likely to receive an S-ICD for secondary prevention (72.3% vs 35.9%; P < 0.001), and less likely to have severe systolic dysfunction of the systemic ventricle (28.1% vs 53.1%; P < 0.001). Over a mean follow-up period of 1.9 years, 16 (15.8%) patients with CHD received at least 1 appropriate shock, with all shocks successfully terminating the ventricular arrhythmia. The crude risk of appropriate S-ICD shock was twice as high in patients with CHD compared with non-CHD patients (annual incidences of 9.0% vs 4.4%; HR: 2.1; 95% CI: 1.3-3.4); however, this association was no longer significant after propensity matching (especially considering S-ICD indication, P = 0.12). The burden of all complications (HR: 1.2; 95% CI: 0.7-2.1; P = 0.4) and inappropriate shocks (HR: 0.9; 95% CI: 0.4-2.0; P = 0.9) was comparable in both groups. CONCLUSIONS: In this nationwide study, patients with CHD represented 2% of all S-ICD implantations. Our findings emphasize the effectiveness and safety of S-ICD in this particularly high-risk population. (S-ICD French Cohort Study [HONEST]; NCT05302115).


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Transposição dos Grandes Vasos , Humanos , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Estudos de Coortes , Resultado do Tratamento , Estudos Retrospectivos , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/terapia
12.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37498147

RESUMO

AIMS: Electrophysiology (EP) is a growing field in cardiology, with an increasing involvement of young people. Nevertheless, concerns about radiation exposure and its impact on reproduction and pregnancy may discourage the choice of an EP career. The study is aimed at investigating the level of awareness and main sources of concern about the effects of radiation on reproductive potential and pregnancy, exploring the safety measures adopted in different EP labs, and verifying the adherence to the current guidelines. METHODS AND RESULTS: An online survey was conducted using the European Heart Rhythm Association (EHRA) infrastructure from April to June 2022. A total of 252 EP personnel (42% women) participated, from 50 countries and different professional roles. Most participants expressed concerns regarding the effects of radiation on reproductive capacity (67.1%) and offspring diseases (68.2%). Only 37.9% of participants were aware of the EHRA 2017 consensus document about occupational radiation exposure. Most participants (80.9%) considered that occupational radiation during pregnancy is not safe. EP female staff were not allowed to work in the EP lab during pregnancy in 48.1% of cases. Zero-fluoroscopy was the preferred choice to continue working in the EP lab during pregnancy. CONCLUSION: EP staff, including both men and women, have concerns about the effects of radiation on reproductive capacity. Despite the recommendations issued by international bodies, implementation of the policies regarding pregnancy and occupational radiation exposure is heterogeneous. Zero-fluoroscopy is the preferred approach to ensure safety during pregnancy in the EP lab.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Lesões por Radiação , Masculino , Gravidez , Feminino , Humanos , Adolescente , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Inquéritos e Questionários , Reprodução , Eletrofisiologia Cardíaca , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/prevenção & controle , Doses de Radiação
13.
Circ Arrhythm Electrophysiol ; 16(6): e011745, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37170812

RESUMO

BACKGROUND: Ventricular arrhythmias and sudden death are recognized complications in tetralogy of Fallot. Electrophysiological studies (EPS) before pulmonary valve replacement (PVR), the most common reintervention in tetralogy of Fallot, could potentially inform therapy to improve arrhythmic outcomes. METHODS: A prospective multicenter study was conducted to systematically assess EPS with programmed ventricular stimulation in patients with tetralogy of Fallot referred for PVR from January 2020 to December 2021. A standardized stimulation protocol was used across all centers. RESULTS: A total of 120 patients were enrolled, mean age 39.2±14.5 years, 53.3% males. Sustained ventricular tachycardia was induced in 27 (22.5%) patients. When identifiable, the critical isthmus most commonly implicated (ie, in 90.0%) was between the ventricular septal defect patch and pulmonary annulus. Factors independently associated with inducible ventricular tachycardia were history of atrial arrhythmia (odds ratio, 8.56 [95% CI, 2.43-34.73]) and pulmonary annulus diameter >26 mm (odds ratio, 5.05 [95% CI, 1.47-21.69]). The EPS led to a substantial change in management in 23 (19.2%) cases: 18 (15.0%) had catheter ablation, 3 (2.5%) surgical cryoablation during PVR, and 9 (7.5%) defibrillator implantation. Repeat EPS 5.1 (4.8-6.2) months after PVR was negative in 8 of 9 (88.9%) patients. No patient experienced a sustained ventricular arrhythmia during 13 (6.1-20.1) months of follow-up. CONCLUSIONS: Systematically performing programmed ventricular stimulation in patients with tetralogy of Fallot referred for PVR yields a high rate of inducible ventricular tachycardia and carries the potential to alter management. It remains to be determined whether a standardized treatment approach based on the results of EPS will translate into improved outcomes. REGISTRATION: URL: https://clinicaltrials.gov/ct2/show/NCT04205461; Unique identifier: NCT04205461.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Pulmonar , Valva Pulmonar , Taquicardia Ventricular , Tetralogia de Fallot , Masculino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Feminino , Valva Pulmonar/cirurgia , Tetralogia de Fallot/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia
14.
Expert Rev Cardiovasc Ther ; 21(7): 507-517, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37246899

RESUMO

INTRODUCTION: The prevalence of congenital heart disease (CHD) is steadily increasing among adults. Atrial arrhythmias are frequent late complications and are associated with substantial morbidity. AREAS COVERED: We discuss key considerations regarding management strategies for atrial arrhythmias in common forms of CHD and offer future perspectives. EXPERT OPINION: An appreciation of the types of atrial arrhythmias encountered in patients with diverse forms of CHD, combined with the growing clinical and research experience, appears to be yielding favorable results, whereas little progress has been made on the antiarrhythmic drug front, indications for anticoagulation have considerably evolved. Advances in interventional techniques have propelled catheter ablation to the forefront to treat a variety of atrial arrhythmias in patients with complex CHD. Nevertheless, much work remains to be done to elucidate underlying pathophysiology, triggers, and critical substrates that predispose patients with specific CHD malformations to develop atrial arrhythmias. Future advances could allow for the implementation of individualized, possibly preemptive, approaches to arrhythmia management. With the prevalence of atrial fibrillation on the rise in the aging population with CHD, concerted efforts must be directed toward optimizing patient selection for catheter ablation as well as refining procedural aspects to safely and more effectively improve long-term outcomes.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Cardiopatias Congênitas , Adulto , Humanos , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Fibrilação Atrial/epidemiologia , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/terapia , Antiarrítmicos/uso terapêutico , Ablação por Cateter/métodos , Prevalência
15.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37208303

RESUMO

AIMS: The epidemiology of sudden cardiac death (SCD) after heart transplantation (HTx) remains imprecisely described. We aimed to assess the incidence and determinants of SCD in a large cohort of HTx recipients, compared with the general population. METHODS AND RESULTS: Consecutive HTx recipients (n = 1246, 2 centres) transplanted between 2004 and 2016 were included. We prospectively assessed clinical, biological, pathologic, and functional parameters. SCD was centrally adjudicated. We compared the SCD incidence beyond the first year post-transplant in this cohort with that observed in the general population of the same geographic area (registry carried out by the same group of investigators; n = 19 706 SCD). We performed a competing risk multivariate Cox model to identify variables associated with SCD. The annual incidence of SCD was 12.5 per 1,000 person-years [95% confidence interval (CI), 9.7-15.9] in the HTx recipients cohort compared with 0.54 per 1,000 person-years (95% CI, 0.53-0.55) in the general population (P < 0.001). The risk of SCD was markedly elevated among the youngest HTx recipients with standardized mortality ratios for SCD up to 837 for recipients ≤30 years. Beyond the first year, SCD was the leading cause of death. Five variables were independently associated with SCD: older donor age (P = 0.003), younger recipient age (P = 0.001) and ethnicity (P = 0.034), pre-existing donor-specific antibodies (P = 0.009), and last left ventricular ejection fraction (P = 0.048). CONCLUSION: HTx recipients, particularly the youngest, were at very high risk of SCD compared with the general population. The consideration of specific risk factors may help identify high-risk subgroups.


Assuntos
Transplante de Coração , Função Ventricular Esquerda , Humanos , Volume Sistólico , Função Ventricular Esquerda/fisiologia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Transplante de Coração/efeitos adversos , Fatores de Risco
17.
Arch Cardiovasc Dis ; 116(4): 183-191, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36858909

RESUMO

BACKGROUND: Coronavirus disease 2019 (COVID-19) is associated with an inflammatory cytokine burst and a prothrombotic coagulopathy. Platelets may contribute to microthrombosis, and constitute a therapeutic target in COVID-19 therapy. AIM: To assess if platelet activation influences mortality in COVID-19. METHODS: We explored two cohorts of patients with COVID-19. Cohort A included 208 ambulatory and hospitalized patients with varying clinical severities and non-COVID patients as controls, in whom plasma concentrations of the soluble platelet activation biomarkers CD40 ligand (sCD40L) and P-selectin (sP-sel) were quantified within the first 48hours following hospitalization. Cohort B was a multicentre cohort of 2878 patients initially admitted to a medical ward. In both cohorts, the primary outcome was in-hospital mortality. RESULTS: In cohort A, median circulating concentrations of sCD40L and sP-sel were only increased in the 89 critical patients compared with non-COVID controls: sP-sel 40,059 (interquartile range 26,876-54,678)pg/mL; sCD40L 1914 (interquartile range 1410-2367)pg/mL (P<0.001 for both). A strong association existed between sP-sel concentration and in-hospital mortality (Kaplan-Meier log-rank P=0.004). However, in a Cox model considering biomarkers of immunothrombosis, sP-sel was no longer associated with mortality, in contrast to coagulopathy evaluated with D-dimer concentration (hazard ratio 4.86, 95% confidence interval 1.64-12.50). Moreover, in cohort B, a Cox model adjusted for co-morbidities suggested that prehospitalization antiplatelet agents had no significant impact on in-hospital mortality (hazard ratio 1.05, 95% CI 0.80-1.37; P=0.73). CONCLUSIONS: Although we observed an association between excessive biomarkers of platelet activation and in-hospital mortality, our findings rather suggest that coagulopathy is more central in driving disease progression, which may explain why prehospitalization antiplatelet drugs were not a protective factor against mortality in our multicentre cohort.


Assuntos
COVID-19 , Inibidores da Agregação Plaquetária , Humanos , Inibidores da Agregação Plaquetária/efeitos adversos , Ativação Plaquetária , Inflamação/diagnóstico , Inflamação/tratamento farmacológico , Biomarcadores
19.
Europace ; 25(3): 961-968, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36735263

RESUMO

AIMS: The implantable cardioverter defibrillator (ICD) has been increasingly used in children. Both epicardial and transvenous approaches are used, with controversy regarding the best option with no specific recommendations. We aimed to compare outcomes associated with epicardial vs. transvenous ICDs in children. METHODS AND RESULTS: Data were analysed from a retrospective study including all patients <18-year-old implanted with an ICD in a tertiary centre from 2003 to 2021. Outcomes were compared between epicardial and transvenous ICDs. A total of 122 children with an ICD (mean age 11.5 ± 3.8 years, 57.4% males) were enrolled, with 84 (64.1%) epicardial ICDs and 38 (29.0%) transvenous ICDs. Early (<30 days) ICD-related complications were reported in 17 (20.2%) patients with an epicardial ICD vs. 0 (0.0%) with a transvenous ICD (P = 0.002). Over a mean follow-up of 4.8 ± 4.0 years, 25 (29.8%) patients with an epicardial ICD and 9 (23.7%) patients with a transvenous ICD experienced at least one late ICD-related complication [hazard ratio (HR) 1.8, 95% confidence interval (CI) 0.8-4.0]. Implantable cardioverter defibrillator lead dysfunction occurred in 19 (22.6%) patients with an epicardial ICD vs. 3 (7.9%) with a transvenous ICD (HR 5.7, 95% CI 1.3-24.5) and was associated with a higher incidence of ICD-related reintervention (HR 3.0, 95% CI 1.3-7.0). After considering potential confounders, especially age and weight at implantation, this association was no longer significant (P = 0.112). The freedom from ICD lead dysfunction was greater in patients with pleural coils than in those with epicardial coils (HR 0.38, 95% CI 0.15-0.96). CONCLUSION: In children, after a consideration of patient characteristics at implantation, the burden of complications and ICD lead dysfunction appears to be similar in patients with epicardial and transvenous devices. Pleural coils seem to be associated with better outcomes than epicardial coils in this population. CLINICAL TRIAL REGISTRATION: NCT05349162.


Assuntos
Desfibriladores Implantáveis , Adolescente , Criança , Feminino , Humanos , Masculino , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Morte Súbita Cardíaca/epidemiologia , Desfibriladores Implantáveis/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...