1.
Opt Express ; 28(24): 36696-36705, 2020 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-33379758

RESUMO

In this work we demonstrate a high sensitivity atomic gradiometer capable of operation in earth-field level environments. We apply a light-pulse sequence at four times the Larmor frequency to achieve gradiometer sensitivity <20 fT/cm/Hz at the finite field strength of 22 µT. The experimental timing sequence can be tuned to the field magnitude of interest. Our all-optical scalar gradiometer performs a differential measurement between two regions of a single vapor cell on a 4 cm baseline. Our results pave the way for extensions to operation in higher dimensions, vector sensitivity, and more advanced gradiometers.

2.
Rev Sci Instrum ; 90(8): 085003, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31472627

RESUMO

Atomic magnetometers (AMs) offer many advantages over superconducting quantum interference devices due to, among other things, having comparable sensitivity while not requiring cryogenics. One of the major limitations of AMs is the challenge of configuring them as gradiometers. We report the development of a spin-exchange relaxation free vector atomic magnetic gradiometer with a sensitivity of 3 fT cm-1 Hz-1/2 and common mode rejection ratio >150 in the band from DC to 100 Hz. We introduce a background suppression figure of merit for characterizing the performance of gradiometers. It allows for optimally setting the measurement baseline and for quickly assessing the advantage, if any, of performing a measurement in a gradiometric mode. As an application, we consider the problem of fetal magnetocardiography (fMCG) detection in the presence of a large background maternal MCG signal.


Assuntos
Feto/fisiologia , Magnetocardiografia/instrumentação , Calibragem , Desenho de Equipamento , Feminino , Humanos , Mães , Processamento de Sinais Assistido por Computador
3.
Rev Mod Phys ; 89(4)2017.
Artigo em Inglês | MEDLINE | ID: mdl-29503479

RESUMO

This article reviews the physics and technology of producing large quantities of highly spin-polarized 3He nuclei using spin-exchange (SEOP) and metastability-exchange (MEOP) optical pumping. Both technical developments and deeper understanding of the physical processes involved have led to substantial improvements in the capabilities of both methods. For SEOP, the use of spectrally narrowed lasers and K-Rb mixtures has substantially increased the achievable polarization and polarizing rate. For MEOP nearly lossless compression allows for rapid production of polarized 3He and operation in high magnetic fields has likewise significantly increased the pressure at which this method can be performed, and revealed new phenomena. Both methods have benefitted from development of storage methods that allow for spin-relaxation times of hundreds of hours, and specialized precision methods for polarimetry. SEOP and MEOP are now widely applied for spin-polarized targets, neutron spin filters, magnetic resonance imaging, and precision measurements.

4.
Phys Rev Lett ; 115(9): 093601, 2015 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-26371650

RESUMO

We demonstrate |W⟩ state encoding of multiatom ensemble qubits. Using optically trapped Rb atoms, the T_{2} coherence time is 2.6(3) ms for N[over ¯]=7.6 atoms and scales approximately inversely with the number of atoms. Strong Rydberg blockade between two ensemble qubits is demonstrated with a fidelity of 0.89(1), and with a fidelity of ∼1.0 when postselected on a control ensemble excitation. These results are a significant step towards deterministic entanglement of atomic ensembles.

5.
Phys Rev Lett ; 115(25): 253001, 2015 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-26722919

RESUMO

We demonstrate a new approach to precision NMR with hyperpolarized gases designed to mitigate NMR shifts due to the alkali spin-exchange field. The NMR bias field is implemented as a sequence of alkali (Rb) 2π pulses, allowing the Rb polarization to be optically pumped transverse to the bias field. When the Rb polarization is modulated at the noble-gas (Xe) NMR resonance, spin-exchange collisions buildup a precessing transverse Xe polarization. We study and mitigate novel NMR broadening effects due to the oscillating spin-exchange field. Spin-exchange frequency shifts are suppressed 2500×, and Rb magnetometer gain measurements project photon shot-noise limited NMR frequency uncertainties below 10 nHz/sqrt[Hz].

7.
Phys Rev Lett ; 111(4): 043002, 2013 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-23931362

RESUMO

We demonstrate that spin-exchange dephasing of Larmor precession at near-Earth-scale fields is effectively eliminated by dressing the alkali-metal atom spins in a sequence of ac-coupled 2π pulses, repeated at the Larmor precession frequency. The contribution of spin-exchange collisions to the spectroscopic linewidth is reduced by a factor of the duty cycle of the pulses. We experimentally demonstrate resonant transverse pumping in magnetic fields as high as 0.1 G, present experimental measurements of the suppressed spin-exchange relaxation, and show enhanced magnetometer response relative to a light-narrowed scalar magnetometer.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/métodos , Magnetismo , Magnetometria/métodos , Metais Alcalinos/química
8.
Opt Lett ; 38(6): 974-6, 2013 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-23503278

RESUMO

In atomic magnetometers, the vector AC-Stark shift associated with circularly polarized light generates spatially varying effective magnetic fields, which limit the magnetometer response and serve as sources of noise. We describe a scheme whereby optically pumping a small subvolume of the magnetometer cell and relying on diffusion to transport polarized atoms allows a magnetometer to be operated with minimal sensitivity to the AC-Stark field.


Assuntos
Eletricidade , Magnetometria , Difusão , Lasers
9.
Phys Rev Lett ; 111(10): 102001, 2013 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-25166656

RESUMO

Various theories beyond the standard model predict new particles with masses in the sub-eV range with very weak couplings to ordinary matter. A new P-odd and T-odd interaction between polarized and unpolarized nucleons proportional to K·r is one such possibility, where r is the distance between the nucleons and K is the spin of the polarized nucleon. Such an interaction involving a scalar coupling gs at one vertex and a pseudoscalar coupling gp at the polarized nucleon vertex can be induced by the exchange of spin-0 bosons. We used the NMR cell test station at Northrop Grumman Corporation to search for NMR frequency shifts in polarized 129Xe and 131Xe when a nonmagnetic zirconia rod is moved near the NMR cell. Long (T2∼20 s) spin-relaxation times allow precision measurements of the NMR frequency ratios, which are insensitive to magnetic field fluctuations. Combined with existing theoretical calculations of the neutron spin contribution to the nuclear angular momentum in xenon nuclei, the measurements improve the laboratory upper bound on the product gsgp(n) by 2 orders of magnitude for distances near 1 mm. The sensitivity of this technique can be increased by at least two more orders of magnitude.

10.
Phys Med Biol ; 57(9): 2619-32, 2012 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-22504066

RESUMO

We present a portable four-channel atomic magnetometer array operating in the spin-exchange relaxation-free regime. The magnetometer array has several design features intended to maximize its suitability for biomagnetic measurement, specifically foetal magnetocardiography, such as a compact modular design and fibre-coupled lasers. The modular design allows the independent positioning and orientation of each magnetometer. Using this array in a magnetically shielded room, we acquire adult magnetocadiograms. These measurements were taken with a 6-11 fT Hz(-1/2) single-channel baseline sensitivity that is consistent with the independently measured noise level of the magnetically shielded room.


Assuntos
Magnetocardiografia/métodos , Adulto , Humanos , Imagens de Fantasmas , Fótons
11.
Phys Rev Lett ; 105(3): 033001, 2010 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-20867761

RESUMO

We predict that a large class of helium-containing cold polar molecules form readily in a cryogenic buffer gas, achieving densities as high as 10(12) cm(-3). We explore the spin relaxation of these molecules in buffer-gas-loaded magnetic traps and identify a loss mechanism based on Landau-Zener transitions arising from the anisotropic hyperfine interaction. Our results show that the recently observed strong T(-6) thermal dependence of the spin-change rate of silver (Ag) trapped in dense (3)He is accounted for by the formation and spin change of Ag(3)He van der Waals molecules, thus providing indirect evidence for molecular formation in a buffer-gas trap.

12.
Phys Rev Lett ; 105(8): 083003, 2010 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-20868095

RESUMO

We present measurements, by using two complementary methods, of the breakdown of atomic angular momentum selection rules in He-broadened Rb vapor. Atomic dark states are rendered weakly absorbing due to fine-structure mixing during Rb-He collisions. The effect substantially increases the photon demand for optical pumping of dense vapors.

13.
Phys Rev Lett ; 104(1): 010503, 2010 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-20366355

RESUMO

We present the first demonstration of a CNOT gate between two individually addressed neutral atoms. Our implementation of the CNOT uses Rydberg blockade interactions between neutral atoms held in optical traps separated by >8 microm. Using two different gate protocols we measure CNOT fidelities of F=0.73 and 0.72 based on truth table probabilities. The gate was used to generate Bell states with fidelity F=0.48+/-0.06. After correcting for atom loss we obtain an a posteriori entanglement fidelity of F=0.58.

14.
Phys Rev Lett ; 101(8): 083002, 2008 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-18764610

RESUMO

We have observed depolarization effects when high intensity cold neutron beams are incident on alkali-metal spin-exchange-polarized 3He cells used as neutron spin filters. This was first observed as a reduction of the maximum attainable 3He polarization and was attributed to a decrease of alkali-metal polarization, which led us to directly measure alkali-metal polarization and spin relaxation over a range of neutron fluxes at Los Alamos Neutron Science Center and Institute Laue-Langevin. The data reveal a new alkali-metal spin-relaxation mechanism that approximately scales as sqrt[phi_{n}], where phi_{n} is the neutron capture-flux density incident on the cell. This is consistent with an effect proportional to the concentration of electron-ion pairs but is much larger than expected from earlier work.

15.
Eur Respir J ; 32(6): 1451-7, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18799503

RESUMO

The balance between inflammatory and repair processes is important in maintaining lung homeostasis in chronic obstructive pulmonary disease (COPD). The aim of the present study was to determine whether or not an integrated index of a biomarker involved in inflammation, C-reactive protein (CRP), and another involved in wound repair, fibronectin, may be a good measure to predict clinical outcomes in COPD. Circulating blood levels of CRP and fibronectin were measured in 4,787 individuals with mild-to-moderate COPD who were prospectively followed for >7 yrs after blood collection as part of the Lung Health Study. To assess the balance between repair and inflammation, a simple ratio was calculated by dividing fibronectin levels by CRP levels and a Cox proportional hazards model was used to determine the relationship between this ratio and all-cause and disease-specific causes of mortality. The relationship between the fibronectin to CRP ratio and all-cause mortality was L-shaped. There was an exponential decay in the adjusted hazard function (i.e. the risk of mortality) as the ratio decreased until a value of 148 was reached, beyond which point the hazard function did not change significantly. Similar results were observed for the risk of coronary and cardiovascular mortality. Circulating fibronectin to CRP ratio is significantly associated with all-cause mortality of COPD patients. However, in contrast to other biomarkers, the relationship appears to be L-shaped (and not linear), suggesting a threshold at approximately 150. While promising, future studies are needed to validate this simple index as a biomarker in COPD.


Assuntos
Biomarcadores/sangue , Proteína C-Reativa/biossíntese , Fibronectinas/sangue , Doença Pulmonar Obstrutiva Crônica/sangue , Doença Pulmonar Obstrutiva Crônica/mortalidade , Adulto , Feminino , Seguimentos , Humanos , Inflamação , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Reprodutibilidade dos Testes , Resultado do Tratamento
16.
Phys Rev Lett ; 100(11): 113003, 2008 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-18517782

RESUMO

We demonstrate Rabi oscillations of small numbers of 87Rb atoms between ground and Rydberg states with n< or =43. Coherent population oscillations are observed for single atoms, while the presence of two or more atoms decoheres the oscillations. We show that these observations are consistent with van der Waals interactions of Rydberg atoms.

17.
Phys Rev Lett ; 96(6): 063001, 2006 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-16605988

RESUMO

We demonstrate Rabi flopping at MHz rates between ground hyperfine states of neutral 87Rb atoms that are trapped in two micron sized optical traps. Using tightly focused laser beams we demonstrate high fidelity, site specific Rabi rotations with cross talk on neighboring sites separated by 8 microm at the level of 10(-3). Ramsey spectroscopy is used to measure a dephasing time of 870 micros, which is approximately 5000 longer than the time for a pi/2 pulse.

18.
Phys Rev Lett ; 96(8): 083003, 2006 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-16606177

RESUMO

Based on measurements of the temperature dependence of 3He relaxation in a wide range of spin-exchange optical pumping cells, we report evidence for a previously unrecognized surface relaxation process. The relaxation rate was found to be linearly proportional to the alkali-metal density with a slope that exceeds the spin-exchange rate, which limits the polarization for current applications, including neutron spin filters, polarized targets, and polarized gas magnetic resonance imaging. We find that the magnitude of this excess relaxation can vary widely between cells, and that the variation is larger for cells of higher surface to volume ratio. We have observed 3He polarization as high as 81%, but further improvements require understanding the origin of this relaxation.

19.
J Res Natl Inst Stand Technol ; 110(3): 299-304, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308140

RESUMO

Polarized (3)He spin filters are needed for a variety of experiments with slow neutrons. Their demonstrated utility for highly accurate determination of neutron polarization are critical to the next generation of betadecay correlation coefficient measurements. In addition, they are broadband devices that can polarize large area and high divergence neutron beams with little gamma-ray background, and allow for an additional spin-flip for systematic tests. These attributes are relevant to all neutron sources, but are particularly well-matched to time of flight analysis at spallation sources. There are several issues in the practical use of (3)He spin filters for slow neutron physics. Besides the essential goal of maximizing the (3)He polarization, we also seek to decrease the constraints on cell lifetimes and magnetic field homogeneity. In addition, cells with highly uniform gas thickness are required to produce the spatially uniform neutron polarization needed for beta-decay correlation coefficient experiments. We are currently employing spin-exchange (SE) and metastability-exchange (ME) optical pumping to polarize (3)He, but will focus on SE. We will discuss the recent demonstration of 75 % (3)He polarization, temperature-dependent relaxation mechanism of unknown origin, cell development, spectrally narrowed lasers, and hybrid spin-exchange optical pumping.

20.
Opt Lett ; 28(14): 1266-8, 2003 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-12885042

RESUMO

We demonstrate the production of high-density cold 87Rb samples (2 x 10(14) atoms/cm3) in a simple optical lattice formed with YAG light that is diffracted from a holographic phase plate. A loading protocol is described that results in 10,000 atoms per 10 microm x 10 microm x 100 microm unit cell of the lattice site. Rapid free evaporation leads to a temperature of 50 microK and phase space densities of 1/150 within 50 ms. The resulting small, high-density atomic clouds are very attractive for a number of experiments, including ultracold Rydberg atom physics.