Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cancer Growth Metastasis ; 8(Suppl 1): 63-80, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26396545

RESUMO

Optical coherence tomography (OCT) is a high-resolution, nondestructive imaging modality that enables time-serial assessment of adenoma development in the mouse model of colorectal cancer. In this study, OCT was utilized to evaluate the effectiveness of interventions with the experimental antitumor agent α-difluoromethylornithine (DFMO) and a nonsteroidal anti-inflammatory drug sulindac during early [chemoprevention (CP)] and late stages [chemotherapy (CT)] of colon tumorigenesis. Biological endpoints for drug interventions included OCT-generated tumor number and tumor burden. Immunochistochemistry was used to evaluate biochemical endpoints [Ki-67, cleaved caspase-3, cyclooxygenase (COX)-2, ß-catenin]. K-Ras codon 12 mutations were studied with polymerase chain reaction-based technique. We demonstrated that OCT imaging significantly correlated with histological analysis of both tumor number and tumor burden for all experimental groups (P < 0.0001), but allows more accurate and full characterization of tumor number and burden growth rate because of its time-serial, nondestructive nature. DFMO alone or in combination with sulindac suppressed both the tumor number and tumor burden growth rate in the CP setting because of DFMO-mediated decrease in cell proliferation (Ki-67, P < 0.001) and K-RAS mutations frequency (P = 0.04). In the CT setting, sulindac alone and DFMO/sulindac combination were effective in reducing tumor number, but not tumor burden growth rate. A decrease in COX-2 staining in DFMO/sulindac CT groups (COX-2, P < 0.01) confirmed the treatment effect. Use of nondestructive OCT enabled repeated, quantitative evaluation of tumor number and burden, allowing changes in these parameters to be measured during CP and as a result of CT. In conclusion, OCT is a robust minimally invasive method for monitoring colorectal cancer disease and effectiveness of therapies in mouse models.

2.
Lasers Surg Med ; 47(1): 30-9, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25449147

RESUMO

BACKGROUND AND OBJECTIVE: We utilize a miniature, dual-modality endoscope that combines fluorescence-based surface magnifying chromoendoscopy (SMC) and optical coherence tomography (OCT) to follow the anatomical changes that occur during adenoma development in the mouse colon. MATERIALS AND METHODS: Twenty-five mice were treated with the carcinogen azoxymethane (AOM) to induce tumor development in the distal colon, or were treated with saline as control, and were imaged over six months. OCT detects adenoma number with high sensitivity and specificity and can measure lesion size. In methylene blue-lavaged colons, SMC detects changes in the colonic crypts. SMC images of control mouse colons exhibit reticulated patterns of crypts of equal size, forming either a dot or honeycomb pattern. RESULTS: Images of AOM-treated colons show mild crypt irregularities even in grossly normal tissue. Images of small to medium adenoma exhibit larger crypts, more intense signal, and irregular spacing whereas those of large adenoma have heterogeneous, intense signal and loss of crypt structure. CONCLUSIONS: The combination of OCT and SMC permits the detection of neoplastic events from the earliest stages of crypt irregularities before gross tissue changes are noted, through to measuring the growth of protruding adenoma.


Assuntos
Adenoma/diagnóstico , Neoplasias do Colo/diagnóstico , Colonoscopia/métodos , Tomografia de Coerência Óptica/métodos , Adenoma/induzido quimicamente , Animais , Azoximetano , Carcinógenos , Neoplasias do Colo/induzido quimicamente , Corantes , Feminino , Azul de Metileno , Camundongos , Variações Dependentes do Observador , Sensibilidade e Especificidade
3.
J Biomed Opt ; 19(6): 067002, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24892970

RESUMO

A side-viewing, 2.3-mm diameter oblique incidence reflectometry endoscope has been designed to obtain optical property measurements of turbid samples. Light from a single-mode fiber is relayed obliquely onto the tissue with a gradient index lens-based distal optics assembly and the resulting diffuse reflectance profile is imaged and collected with a 30,000 element, 0.72 mm clear aperture fiber bundle. Sampling the diffuse reflectance in two-dimensions allows for fitting of the reflected intensity profile to a well-known theoretical model, permitting the extraction of both absorption and reduced scattering coefficients of the tissue sample. Models and measurements of the endoscopic imaging system are presented in tissue phantoms and in vivo mouse colon, verifying the endoscope's capabilities to accurately measure effective attenuation coefficient and differentiate diseased from normal colon.


Assuntos
Endoscopia/instrumentação , Endoscopia/métodos , Dispositivos Ópticos , Óptica e Fotônica , Adenoma/diagnóstico , Adenoma/patologia , Animais , Colo/patologia , Neoplasias do Colo/diagnóstico , Neoplasias do Colo/patologia , Humanos , Incidência , Camundongos , Imagens de Fantasmas , Espalhamento de Radiação , Tomografia de Coerência Óptica/métodos
4.
J Biomed Opt ; 17(8): 086003, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23224190

RESUMO

A side-viewing, 2.3-mm diameter, surface magnifying chromoendoscopy-optical coherence tomography (SMC-OCT) endoscope has been designed for simultaneous, nondestructive surface fluorescence visualization and cross-sectional imaging. We apply this endoscope to in vivo examination of the mouse colon. A 30,000 element fiber bundle is combined with single mode fibers, for SMC and OCT imaging, respectively. The distal optics consist of a gradient-index lens and spacer to provide a 1× magnification at a working distance of 1.58 mm in air, necessary to image the sample through a 0.23-mm thick outer glass envelope, and an aluminized right-angle prism fixed to the distal end of the gradient-index lens assembly. The resulting 1∶1 imaging system is capable of 3.9-µm lateral and 2.3-µm axial resolution in the OCT channel, and 125-lp/mm resolution across a 0.70-mm field of view in the SMC channel. The endoscope can perform high contrast crypt visualization, molecular imaging, and cross-sectional imaging of colon microstructure.


Assuntos
Colo/anatomia & histologia , Colonoscópios , Aumento da Imagem/instrumentação , Microscopia de Fluorescência/instrumentação , Técnica de Subtração/instrumentação , Tomografia de Coerência Óptica/instrumentação , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Camundongos , Camundongos Endogâmicos C57BL , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Biomed Opt Express ; 2(3): 421-30, 2011 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-21412448

RESUMO

Combined optical coherence tomography (OCT) and laser-induced fluorescence (LIF) endoscopy has shown higher sensitivity and specificity for distinguishing normal tissue from adenoma when compared to either modality alone. Endoscope optical design is complicated by the large wavelength difference between the two systems. A new high-resolution endoscope 2 mm in diameter is presented that can create focused beams from the ultraviolet to near-infrared. A reflective design ball lens operates achromatically over a large wavelength range, and employs TIR at two faces and reflection at a third internal mirrored face. The 1:1 imaging system obtains theoretically diffraction-limited spots for both the OCT (1300 nm) and LIF (325 nm) channels.

6.
Phys Biol ; 4(1): 10-5, 2007 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-17406081

RESUMO

Gliding assays of motor proteins such as kinesin, dynein and myosin are commonly carried out with fluorescently labeled microtubules or filamentous actin. In this paper, we show that speckled microtubules (MTs), prepared by copolymerizing 98% unlabeled tubulin with 2% rhodamine-labeled tubulin, can be localized to +/-7.4 nm (24 measurements) in images acquired every 125 ms. If the speckled MTs move at about 800 nm s(-1), ten images are sufficient to determine their velocity to a precision of +/-6.8 nm s(-1) (6 microtubules, 24 measurements). This velocity precision is four-fold better than manual methods for measuring the gliding velocity of uniformly labeled MTs by end-point localization. The improved velocity precision will permit the determination of velocity-force curves when one, two and three kinesin motors pull a single load in vitro.


Assuntos
Proteínas Associadas aos Microtúbulos , Microtúbulos , Modelos Biológicos , Proteínas Motores Moleculares , Animais , Bioensaio , Transporte Biológico , Dineínas/química , Dineínas/metabolismo , Humanos , Cinesinas/química , Cinesinas/metabolismo , Miosinas/química , Miosinas/metabolismo , Conformação Proteica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...