RESUMO
OBJECTIVE: To determine if temperature regulation is improved during neonatal transport using a servo-regulated cooling device when compared with standard practice. STUDY DESIGN: We performed a multicenter, randomized, nonmasked clinical trial in newborns with neonatal encephalopathy cooled during transport to 9 neonatal intensive care units in California. Newborns who met institutional criteria for therapeutic hypothermia were randomly assigned to receive cooling according to usual center practices vs device servo-regulated cooling. The primary outcome was the percentage of temperatures in target range (33°-34°C) during transport. Secondary outcomes included percentage of newborns reaching target temperature any time during transport, time to target temperature, and percentage of newborns in target range 1 hour after cooling initiation. RESULTS: One hundred newborns were enrolled: 49 to control arm and 51 to device arm. Baseline demographics did not differ with the exception of cord pH. For each subject, the percentage of temperatures in the target range was calculated. Infants cooled using the device had a higher percentage of temperatures in target range compared with control infants (median 73% [IQR 17-88] vs 0% [IQR 0-52], P < .001). More subjects reached target temperature during transport using the servo-regulated device (80% vs 49%, P <.001), and in a shorter time period (44 ± 31 minutes vs 63 ± 37 minutes, P = .04). Device-cooled infants reached target temperature by 1 hour with greater frequency than control infants (71% vs 20%, P < .001). CONCLUSIONS: Cooling using a servo-regulated device provides more predictable temperature management during neonatal transport than does usual care for outborn newborns with neonatal encephalopathy.
Assuntos
Asfixia Neonatal/complicações , Temperatura Corporal/fisiologia , Encefalopatias/terapia , Hipotermia Induzida/métodos , Doenças do Recém-Nascido/terapia , Unidades de Terapia Intensiva Neonatal , Transporte de Pacientes/métodos , Asfixia Neonatal/terapia , Encefalopatias/etiologia , Feminino , Seguimentos , Humanos , Recém-Nascido , Masculino , PrognósticoRESUMO
OBJECTIVE: To explore the association between red blood cell transfusion and necrotizing enterocolitis (NEC) in a neonatal intensive care unit with liberal transfusion practices. STUDY DESIGN: A retrospective cohort study was conducted for all infants weighing <1500 g who received at least 1 packed red blood cell transfusion between January 2008 and June 2013 in a tertiary neonatal intensive care unit. The primary outcome was NEC, defined as Bell stage II or greater. The temporal association of NEC and transfusion was assessed using multivariate Poisson regression. RESULTS: The study sample included 414 very low birth weight infants who received 2889 consecutive red blood cell transfusions. Twenty-four infants (5.8%) developed NEC. Four cases of NEC occurred within 48 hours of a previous transfusion event. Using multivariate Poisson regression, we did not find evidence of a temporal association between NEC and transfusion (P = .32). CONCLUSION: There was no association between NEC and red blood cell transfusion. Our results differ from previous studies and suggest that the association between NEC and transfusion may be contextual.